Absorption of water and lubricating oils into porous nylon

Oil and water absorption from air into sintered porous nylon can be described by infiltration into the pores of the material. This process can be modeled by a diffusion-like mechanism. For water absorption, we find a formal diffusion coefficient of 1.5 x 10(exp -4)sq cm/min when the nylon is initially dry. The diffusion coefficient is 4 x 10(exp -6)sq cm/min when the nylon is oil-impregnated prior to air exposure. In a 52% RH atmosphere, dry nylon absorbs 3% w/w water, and oil-impregnated nylon absorbs 0.6% w/w water. For oil absorption there are three steps: (1) surface absorption and infiltration into (2) larger and (3) smaller pores. Surface absorption is too fast to be measured in these experiments. The diffusion coefficient for the second step is 6 x 10(exp -4)sq cm/min for SRG-60 oil into dry nylon and 4 x 10(exp -4)sq cm/min for air-equilibrated nylon. The diffusion coefficient for the third step is about 1 x 10(exp -6)sq cm/min for both cases. The total amount of oil absorbed is 31% w/w. The interaction between water and nylon is not as strong as that between water and cotton-phenolic: oil can replace water, and only a small amount of water can enter previously oil-impregnated nylon.

Bertrand, P. A.

Nylon separators

A nylon separator was placed in a flooded condition in K0H solution and heated at various high temperatures ranging from 60 C to 110 C. The weight decrease was measured and the molecular weight and decomposition product were analyzed to determine: (1) the effect of K0H concentration on the hydrolysis rate; (2) the effect of K0H concentration on nylon degradation; (3) the activation energy at different K0H concentrations; and (4) the effect of oxygen on nylon degradation. The nylon hydrolysis rate is shown to increase as K0H concentration is decreased 34%, giving a maximum rate at about 16%. Separator hydrolysis is confirmed by molecular weight decrease in age of the batteries, and the reaction of nylon with molecular oxygen is probably negligible, compared to hydrolysis. The extrapolated rate value from the high temperature experiment correlates well with experimental values at 35 degrees.

Lim, H. S.

Nylon and teflon scribe effect on NBR to Chemlok 233 and NBR to NBR bond interfaces

A study was requested by Manufacturing Engineering to determine what effects marking with nylon (6/6) and Teflon scribes may have on subsequent bonding. Witness panel bond specimens were fabricated by the development lab to test both acrylonitrile butadiene rubber (NBR) to Chemlok and NBR to NBR after controlled exposure. The nylon rod used as a scribe tool demonstrates virtually no bond deterioration when used to scribe lines on either the Chemlok to NBR surfaces or the NBR to NBR interface. Lab test results indicate that the nylon rod-exposed samples produce tensile and peel values very similar to the control samples and the Teflon exposed samples produce tensile and peel values much lower than the control samples. Visual observation of the failure surfaces of the tested samples shows that Teflon scribing produces an obvious contamination to the surface and the nylon produces no effect. Photographs of test samples are provided. It is concluded that Teflon stock used as a scribe tool on a Chemlok 233 to NBR surface or an NBR to NBR surface has a detrimental effect on the bond integrity on either of these bond interfaces. Therefore, it is recommended that the nylon rod continue to be used where a scribe line is required in the redesigned solid rocket motor segment insulation layup operations. The use of Teflon scribes should not be considered.

Jensen, S. K.

Moisture dependence of positron annihilation spectra in nylon-6

Positron annihilation time spectra have been measured in nylon-6 samples as a function of their moisture content. The measured average long life component lifetime values are: 1722 + or - 47 ps (dry), 1676 + or - 40 ps (14.6 percent saturation value), 1719 + or - 26 ps (29.3 percent saturation value), 1720 + or - 35 ps (50 percent of saturation value), 1857 + or - 35 ps (78.1 percent saturation value), and 1936 + or - 57 ps (saturated). It appears that nylon-6 has a special affinity for water at low concentration levels where H2O molecules enter between the (C = O - H-N) chemical bonds between nylon molecular chains. As the water concentration increases beyond a critical level, nylon-6 specimens start trapping H2O molecules in other bond sites or potential wells. The trapped water increases the free volume in the test specimens and reduces Ps atom formation as well as its subsequent decay rate.

Singh, J. J.

Novel use of positively charged nylon transfer membranes for trapping indoleacetic acid or other small anions during efflux from plant tissues

Positively charged nylon blotting membranes were used as an anion binding medium to trap [14C]indoleactic acid (IAA) as it exited cells at the basal ends of Coleus blumei L. stem and Zea mays L. coleoptile segments. Autoradiography was used to visualize where the [14C] that moved out of the cut ends was localized on the nylon membrane. Diffusion of [14C]IAA from the initial point of contact with the nylon membrane was minimal. Comparison of the autoradiograms with anatomical tissue prints of the cut ends of the segments was used to determine what tissues participate in IAA movement. The results of these initial studies were consistent with other reports suggesting that [14C]IAA movement was primarily associated with vascular tissues in both C. blumei stems and corn coleoptiles, but the resolution was not sufficient to identify which vascular tissues were involved in IAA transport. With further refinements, this technique could also be used for studying the movement of other small charged molecules through plant tissues.

NASA Discipline Plant Biology

Measuring tropospheric HNO3 - Problems and prospects for Nylon filter and mist chamber techniques

A series of laboratory and field measurements was performed to evaluate the mist chamber technique for determining tropospheric HNO3 concentrations. Both the mist chamber and standard Nylon filter techniques exhibit high collection efficiency and excellent agreement measuring HNO3 vapors from a permeation source. When simultaneously sampling ambient air in eastern Virginia, the Nylon filter measured an average of 70 percent higher HNO3 concentration than the mist chamber technique. The results indicate that O3 causes a low-level positive artifact interference in HNO3 measurements performed with the filter technique. This O3-induced error is small, however, compared to the large difference between atmospheric HNO3 concentrations determined with the two techniques. It is hypothesized that unidentified (organic?) nitrogen species in the atmosphere react for form NO3(-) on the filter and this phenomenon may interfere with Nylon filter measurements of HNO3 vapor. These potential interferences did not appear to affect measurements of HNO3 with the mist chamber method.

Talbot, R. W.

Nylon Sleeve for Cavity Amplifier Holds Tuning Despite Heat

The problem: Detuning of cavity amplifiers with change in temperature. This results in deterioration of the performance of the amplifier at its design frequency. In cavity amplifiers and filters it is desirable that constant performance be maintained regardless of thermal changes. These changes often cause an "off resonance shift" in a cavity filter and a deterioration of performance in a cavity amplifier. The solution: Mount the tuning probe in a nylon sleeve. Thermal expansion and contraction of the nylon nullifies unwanted capacitive and inductive changes in the resonant elements.

Derr, Lloyd

Nylon shock absorber prevents injury to parachute jumpers

Nylon shock absorbers reduce the canopy-opening shock of a parachute to a level that protects the wearer from injury. A shock absorber is mounted on each of the four risers between the shroud lines and the harness. Because of their size and location, they pose no problem in repacking the chute and harness after a jump.

Mandel, J. A.