Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nonparametric testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nonparametric test of consistency between cosmological models and multiband CMB measurements

We present a novel approach to test the consistency of the cosmological models with multiband CMB data using a nonparametric approach. In our analysis we calibrate the REACT (Risk Estimation and Adaptation after Coordinate Transformation) confidence levels associated with distances in function space (confidence distances) based on the Monte Carlo simulations in order to test the consistency of an assumed cosmological model with observation. To show the applicability of our algorithm, we confront Planck 2013 temperature data with concordance model of cosmology considering two different Planck spectra combination. In order to have an accurate quantitative statistical measure to compare between the data and the theoretical expectations, we calibrate REACT confidence distances and perform a bias control using many realizations of the data. Our results in this work using Planck 2013 temperature data put the best fit ΛCDM model at 95% (∼ 2σ) confidence distance from the center of the nonparametric confidence set while repeating the analysis excluding the Planck 217 × 217 GHz spectrum data, the best fit ΛCDM model shifts to 70% (∼ 1σ) confidence distance. The most prominent features in the data deviating from the best fit ΛCDM model seems to be at low multipoles 18 < ℓ < 26 at greater than 2σ, ℓ ∼ 750 at ∼1 to 2σ and ℓ ∼ 1800 at greater than 2σ level. Excluding the 217×217 GHz spectrum the feature at ℓ ∼ 1800 becomes substantially less significance at ∼1 to 2σ confidence level. Results of our analysis based on the new approach we propose in this work are in agreement with other analysis done using alternative methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Asymptotic Efficiency of New Distribution-Free Tests of Symmetry for Generalized Skew Alternatives

The Bahadur efficiency of new nonparametric tests of symmetry recently proposed by Nikitin and Ahsanullah is calculated. In contrast to this result, where only location alternatives were discussed, in the present paper generalized skew alternatives are of interest. It is shown that the new tests are highly efficient for a large class of skew alternatives. The problem of most favorable alternatives is also studied.

97 MATHEMATICS AND COMPUTING↗

Percent-Level Test of Isotropic Expansion Using Type Ia Supernovae

We propose and implement a novel, robust, and nonparametric test of statistical isotropy of the expansion of the Universe and apply it to around 1000 type Ia supernovae from the Pantheon sample. We calculate the angular clustering of supernova magnitude residuals and compare it to the noise expected under the isotropic assumption. We also test for systematic effects and demonstrate that their effects are negligible or are already accounted for in our procedure. Here, we express our constraints as an upper limit on the rms spatial variation in the Hubble parameter at late times. For the sky smoothed with a Gaussian with FWHM = 60°, less than 1% rms spatial variation in the Hubble parameter is allowed at 99.7% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

Dietary B group vitamin intake and the bladder cancer risk: a pooled analysis of prospective cohort studies

Abstract Purpose Diet may play an essential role in the aetiology of bladder cancer (BC). The B group complex vitamins involve diverse biological functions that could be influential in cancer prevention. The aim of the present study was to investigate the association between various components of the B group vitamin complex and BC risk. Methods Dietary data were pooled from four cohort studies. Food item intake was converted to daily intakes of B group vitamins and pooled multivariate hazard ratios (HRs), with corresponding 95% confidence intervals (CIs), were obtained using Cox-regression models. Dose–response relationships were examined using a nonparametric test for trend. Results In total, 2915 BC cases and 530,012 non-cases were included in the analyses. The present study showed an increased BC risk for moderate intake of vitamin B1 (HR B1 : 1.13, 95% CI: 1.00–1.20). In men, moderate intake of the vitamins B1, B2, energy-related vitamins and high intake of vitamin B1 were associated with an increased BC risk (HR (95% CI): 1.13 (1.02–1.26), 1.14 (1.02–1.26), 1.13 (1.02–1.26; 1.13 (1.02–1.26), respectively). In women, high intake of all vitamins and vitamin combinations, except for the entire complex, showed an inverse association (HR (95% CI): 0.80 (0.67–0.97), 0.83 (0.70–1.00); 0.77 (0.63–0.93), 0.73 (0.61–0.88), 0.82 (0.68–0.99), 0.79 (0.66–0.95), 0.80 (0.66–0.96), 0.74 (0.62–0.89), 0.76 (0.63–0.92), respectively). Dose–response analyses showed an increased BC risk for higher intake of vitamin B1 and B12. Conclusion Our findings highlight the importance of future research on the food sources of B group vitamins in the context of the overall and sex-stratified diet.

60 APPLIED LIFE SCIENCES↗

SPECT Analysis of Cardiac Perfusion Changes After Whole-Breast/Chest Wall Radiation Therapy With or Without Active Breathing Coordinator: Results of a Randomized Phase 3 Trial

Purpose: Cardiac muscle perfusion, as determined by single-photon emission computed tomography (SPECT), decreases after breast and/or chest wall (BCW) irradiation. The active breathing coordinator (ABC) enables radiation delivery when the BCW is farther from the heart, thereby decreasing cardiac exposure. We hypothesized that ABC would prevent radiation-induced cardiac toxicity and conducted a randomized controlled trial evaluating myocardial perfusion changes after radiation for left-sided breast cancer with or without ABC. Methods and Materials: Stages I to III left breast cancer patients requiring adjuvant radiation therapy (XRT) were randomized to ABC or No-ABC. Myocardial perfusion was evaluated by SPECT scans (before and 6 months after BCW radiation) using 2 methods: (1) fully automated quantitative polar mapping; and (2) semiquantitative visual assessment. The left ventricle was divided into 20 segments for the polar map and 17 segments for the visual method. Segments were grouped by anatomical rings (apical, mid, basal) or by coronary artery distribution. For the visual method, 2 nuclear medicine physicians, blinded to treatment groups, scored each segment's perfusion. Scores were analyzed with nonparametric tests and linear regression. Results: Between 2006 and 2010, 57 patients were enrolled and 43 were available for analysis. The cohorts were well matched. The apical and left anterior descending coronary artery segments had significant decreases in perfusion on SPECT scans in both ABC and No-ABC cohorts. In unadjusted and adjusted analyses, controlling for pretreatment perfusion score, age, and chemotherapy, ABC was not significantly associated with prevention of perfusion deficits. Conclusions: In this randomized controlled trial, ABC does not appear to prevent radiation-induced cardiac perfusion deficits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MicroRNA-Related DNA Repair/Cell-Cycle Genes Independently Associated With Relapse After Radiation Therapy for Early Breast Cancer

Purpose: Local recurrence and distant failure after adjuvant radiation therapy for breast cancer remain significant clinical problems, incompletely predicted by conventional clinicopathologic markers. We had previously identified microRNA-139-5p and microRNA-1274a as key regulators of breast cancer radiation response in vitro. The purpose of this study was to investigate standard clinicopathologic markers of local recurrence in a contemporary series and to establish whether putative target genes of microRNAs involved in DNA repair and cell cycle control could better predict radiation therapy response in vivo. Methods and Materials: With institutional ethics board approval, local recurrence was measured in a contemporary, prospectively collected series of 458 patients treated with radiation therapy after breast-conserving surgery. Additionally, independent publicly available mRNA/microRNA microarray expression datasets totaling >1000 early-stage breast cancer patients, treated with adjuvant radiation therapy, with >10 years of follow-up, were analyzed. The expression of putative microRNA target biomarkers—TOP2A, POLQ, RAD54L, SKP2, PLK2, and RAG1—were correlated with standard clinicopathologic variables using 2-sided nonparametric tests, and to local/distant relapse and survival using Kaplan-Meier and Cox regression analysis. Results: We found a low rate of isolated local recurrence (1.95%) in our modern series, and that few clinicopathologic variables (such as lymphovascular invasion) were significantly predictive. In multiple independent datasets (n>1000), however, high expression of RAD54L, TOP2A, POLQ, and SKP2 significantly correlated with local recurrence, survival, or both in univariate and multivariate analyses (P<.001). Low RAG1 expression significantly correlated with local recurrence (multivariate, P=.008). Additionally, RAD54L, SKP2, and PLK2 may be predictive, being prognostic in radiation therapy–treated patients but not in untreated matched control individuals (n=107; P<.05). Conclusions: Biomarkers of DNA repair and cell cycle control can identify patients at high risk of treatment failure in those receiving radiation therapy for early breast cancer in independent cohorts. These should be further investigated prospectively, especially TOP2A and SKP2, for which targeted therapies are available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark Credentialing Results for NRG-BR001: The First National Cancer Institute-Sponsored Trial of Stereotactic Body Radiation Therapy for Multiple Metastases

Purpose: The NRG-BR001 trial is the first National Cancer Institute–sponsored trial to treat multiple (range 2-4) extracranial metastases with stereotactic body radiation therapy. Benchmark credentialing is required to ensure adherence to this complex protocol, in particular, for metastases in close proximity. The present report summarizes the dosimetric results and approval rates. Methods and Materials: The benchmark used anonymized data from a patient with bilateral adrenal metastases, separated by <5 cm of normal tissue. Because the planning target volume (PTV) overlaps with organs at risk (OARs), institutions must use the planning priority guidelines to balance PTV coverage (45 Gy in 3 fractions) against OAR sparing. Submitted plans were processed by the Imaging and Radiation Oncology Core and assessed by the protocol co-chairs by comparing the doses to targets, OARs, and conformity metrics using nonparametric tests. Results: Of 63 benchmarks submitted through October 2015, 94% were approved, with 51% approved at the first attempt. Most used volumetric arc therapy (VMAT) (78%), a single plan for both PTVs (90%), and prioritized the PTV over the stomach (75%). The median dose to 95% of the volume was 44.8 ± 1.0 Gy and 44.9 ± 1.0 Gy for the right and left PTV, respectively. The median dose to 0.03 cm{sup 3} was 14.2 ± 2.2 Gy to the spinal cord and 46.5 ± 3.1 Gy to the stomach. Plans that spared the stomach significantly reduced the dose to the left PTV and stomach. Conformity metrics were significantly better for single plans that simultaneously treated both PTVs with VMAT, intensity modulated radiation therapy, or 3-dimensional conformal radiation therapy compared with separate plans. No significant differences existed in the dose at 2 cm from the PTVs. Conclusions: Although most plans used VMAT, the range of conformity and dose falloff was large. The decision to prioritize either OARs or PTV coverage varied considerably, suggesting that the toxicity outcomes in the trial could be affected. Several benchmarks met the dose-volume histogram metrics but produced unacceptable plans owing to low conformity. Dissemination of a frequently-asked-questions document improved the approval rate at the first attempt. Benchmark credentialing was found to be a valuable tool for educating institutions about the protocol requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the {gamma} function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. Disagreement in the lung region was also found when the {Gamma} analysis was performed. The effect on TCP is less important than for NTCP because of the slope of the curve at the level of the dose of interest. The effect of dose calculation inaccuracy is patient-dependent and strongly related to beam geometry and to the localization of the tumor. When multiple intensity-modulated beams are used, the effect of the presence of the heterogeneity on dose distribution may not always be easily predictable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hydroacoustic Assessment of Behavioral Responses by Fish Passing Near an Operating Tidal Turbine in the East River, New York

An important environmental issue facing the marine and hydrokinetic energy industry is whether fish that encounter underwater energy devices are likely to be struck and injured by moving components, primarily rotating turbine blades. The automated analysis of nearly 3 weeks of multibeam hydroacoustics data identified about 35,000 tracks of fish passing a tidal turbine in the East River, New York. These tracks included both individual fish and schools during periods with the turbine absent, the turbine present and operating, and the turbine present but not operating. The density of fish in the sampled area when the turbine was absent was roughly twice the density observed when the turbine was in place, particularly when the turbine was operating. This suggests that some avoidance occurred before fish were close enough to the turbine to be observed by the hydroacoustics system. Various measures of swimming behavior (direction, velocity, and linearity) were calculated for each track and evaluated for indication of behavioral responses to turbine presence and operation. Fish tracks were grouped based on tidal cycle, current velocity, and swimming direction and were evaluated with respect to turbine presence and operation and with respect to distance from the turbine. Nonparametric tests (Kolmogorov–Smirnov test) and multivariate analysis (canonical discriminant analysis) found significant differences among groups with respect to turbine presence and operation, suggesting that some fish responded to the turbine by adjusting swimming behavior, such as making small adjustments to swimming direction and velocity as they passed near the turbine. We found no evidence that fish were being struck by rotating blades, but there did appear to be large-scale avoidance initiated out of the range of the hydroacoustics detection system. Furthermore, more study is needed to determine whether such avoidance behavior has significant ramifications for normal fish movement patterns, bioenergetics, seasonal migrations, and predator exposure.

13 HYDRO ENERGY↗

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy

Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-based approach to investigate equipment-induced error in pressure-waveform derived hemodynamic measurements

Advanced hemodynamic monitoring systems have provided less invasive methods for estimating pressure-derived measurements such as pressure-derived cardiac output (CO) measurements. These devices apply algorithms to arterial pressure waveforms recorded via pressure recording components that transmit the pressure signal to a pressure monitor. While standards have been developed for pressure monitoring equipment, it is unclear how the equipment-induced error can affect secondary measurements from pressure waveforms. We propose an approach for modelling different components of a pressure monitoring system and use this model-based approach to investigate the effect of different pressure recording configurations on pressure-derived hemodynamic measurements. The proposed model-based approach is a three-step process. (1) Modelling the response of pressure recording components using bench tests; (2) verifying the identified models through nonparametric equivalence tests; and (3) assessing the effects of pressure recording components on pressure-derived measurements. To delineate the application of this approach, we performed a series of model-based analyses to quantify the combined effect of a wide range of tubing configurations with various damping ratios and natural frequencies and monitors with different bandwidths on pressure waveforms and CO measurements by six pulse contour algorithms. Model-based results show the error in pressure-derived CO measurements because of tubing configurations with different natural frequencies and damping ratios. Tubing configurations with low natural frequencies (<23 Hz) altered characteristics of pressure waveforms in a way that affected the CO measurement, some by as much as 20%. Our method can serve as a tool to quantify the performance of pressure recording systems with different dynamic properties. In conclusion, this approach can be applied to investigate the effects of physiologic signal recording configurations on various pressure-derived hemodynamic measurements.

42 ENGINEERING↗

Anomalies in the topology of the temperature fluctuations in the cosmic microwave background: An analysis of the NPIPE and FFP10 data releases

We present a topological analysis of the temperature fluctuation maps from the Planck 2020 Data Release 4 NPIPE dataset and the Planck 2018 Data Release 3 FFP10 dataset. We performed a multiscale analysis in terms of the homology characteristics of the maps, invoking relative homology to account for the analysis in the presence of masks. We performed our analysis for a range of smoothing scales spanning sub- and super-horizon scales corresponding to a full width at half maximum (FWHM) of 5',10',20',40',80',160',320', and 640', and employed simulations based on the standard model for comparison, which assumes the initial fluctuation field to be an isotropic and homogeneous Gaussian random field. Examining the behavior of topological components, represented by the 0D homology group, we find the observations to be approximately 2σ or less deviant from the simulations for all resolutions and scales for the NPIPE dataset. For the FFP10 dataset, we detect a 2.96σ deviation between the observations and simulations at N = 128, FWHM = 80'. For the topological loops, represented by the first homology group, the simulations and observations are consistent within 2σ for most resolutions and scales for both the datasets. However, for the NPIPE dataset, we observe a high deviation between the observation and simulations in the number of loops at FWHM = 320', but at a low dimensionless threshold ν = –2.5. Under a Gaussian assumption, this would amount to a deviation of ~4σ. However, the distribution in this bin is manifestly non-Gaussian and does not obey Poisson statistics either. In the absence of a true theoretical understanding, we simply note that the significance is higher than what may be resolved by 600 simulations, yielding an empirical p-value of at most 0.0016. Specifically in this case, our tests indicate that the numbers arise from a statistically stable regime, despite being based on small numbers. For the FFP10 dataset, the differences are not as strong as for the NPIPE dataset, indicating a 2.77σ deviation at this resolution and threshold. The Euler characteristic, which is the alternating sum of the ranks of relative homology groups, reflects the deviations in the components and loops. To assess the significance of combined levels for a given scale, we employed the empirical and theoretical versions of the χ 2 test as well as the nonparametric Tukey depth test. Although all statistics exhibit a stable distribution, we favor the empirical version of the χ 2 test in the final interpretation, as it indicates the most conservative differences. For the NPIPE dataset, we find that the components and loops differ at more than 95%, but agree within the 99% confidence level with respect to the base model at N = 32, FWHM = 320'. The Euler characteristic at this resolution displays a per mil deviation. In contrast, the FFP10 dataset shows that the observations are consistent with the base model within the 95% confidence level, at this and smaller scales. This is consistent with the observations of the Planck analysis pipeline via Minkowski functionals. For the largest smoothing scale, N = 16, FWHM = 640', both datasets exhibit an anomalous behavior of the loops, where FFP10 data exhibit a deviation that is larger by an order of magnitude than that of the NPIPE dataset. In contrast, the values for the topological components and the Euler characteristic agree between observations and model to within a confidence level of 99%. However, for the largest scales, the statistics are based on low numbers and may have to be regarded with caution. Even though both datasets exhibit mild to significant discrepancies, they also exhibit contrasting behaviors at various instances. Therefore, we do not find it feasible to convincingly accept or reject the null hypothesis. Disregarding the large-scale anomalies that persist at similar scales in WMAP and Planck, observations of the cosmic microwave background are largely consistent with the standard cosmological model within 2σ.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing parity violation with the four-point correlation function of BOSS galaxies

Parity-violating physics in the early universe can leave detectable traces in late-time observables. While vector- and tensor-type parity violation can be observed in the B -modes of the cosmic microwave background, scalar-type signatures are visible only in the four-point correlation function (4PCF) and beyond. This work presents a blind test for parity violation in the 4PCF of the baryon oscillation spectroscopic survey (BOSS) CMASS sample, considering galaxy separations in the range [20; 160]h -1 Mpc The parity-odd 4PCF contains no contributions from standard Λ CDM physics and can be efficiently measured using recently developed estimators. Data are analyzed using both a nonparametric rank test (comparing the BOSS 4PCFs to those of realistic simulations) and a compressed χ 2 analysis, with the former avoiding the assumption of a Gaussian likelihood. These find similar results, with the rank test giving a detection probability of 99.6% (2.9 σ). This provides significant evidence for parity violation, from either cosmological sources or systematics. We perform a number of systematic tests: although these do not reveal any observational artifacts, we cannot exclude the possibility that our detection is caused by the simulations not faithfully representing the statistical properties of the BOSS data. Our measurements can be used to constrain physical models of parity violation. As an example, we consider a coupling between the inflaton and a U (1) gauge field and place bounds on the latter’s energy density, which are several orders of magnitude stronger than those previously reported. Upcoming probes such as DESI and Euclid will reveal whether our detection of parity violation is due to new physics, and strengthen the bounds on a variety of models.

79 ASTRONOMY AND ASTROPHYSICS↗

A Nonparametric Method for the Inference of Halo Occupation Distributions

The galaxy–halo connection traces processes by which galaxies form and evolve. The halo occupation distribution (HOD) describes the relationship between galaxies and their host dark matter haloes. Measurements of the galaxy two-point correlation function (2PCF) allow us to extract information about the HODs of observed galaxy samples. Several parametric HOD models have been proposed in the literature, but the choice of parameterization restricts the space of possible HODs. To resolve this issue, we introduce a nonparametric HOD fitting method in which we train an emulator to learn the mappings among the galaxy 2PCF, physical properties used to select galaxy samples, and the HOD, all obtained from simulated past light cones constructed with the Santa Cruz semianalytic model. Implementing this emulator within a likelihood analysis framework, we derive constraints on the HOD of a galaxy sample when provided with a measurement of its 2PCF. Using the emulator to accelerate likelihood evaluations, we test the nonparametric HOD approach on a set of 2PCFs for mock galaxy samples drawn from the TNG100-1 simulation and selected above threshold values of stellar mass and star formation rate. Our framework is able to recover TNG100-1 HODs within 0.2 dex. We use the TNG100-1 mocks to tune the reported uncertainties to estimate those expected in the analysis of observations. Comparing to parametric HOD modelling routines applied to the same mock galaxy samples, our approach consistently infers the HOD with comparable or greater precision and accuracy.

Kennedy, Jacob [Rutgers Univ., Piscataway, NJ (Uni↗

Diffusion and perfusion MR parameters to assess preoperative short-course radiotherapy response in locally advanced rectal cancer: a comparative explorative study among Standardized Index of Shape by DCE-MRI, intravoxel incoherent motion- and diffusion kurtosis imaging-derived parameters

Purpose: To assess preoperative short-course radiotherapy (SCR) tumor response in locally advanced rectal cancer (LARC) by means of Standardized Index of Shape (SIS) by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI) parameters derived from diffusion-weighted MRI (DW-MRI). Materials and methods: Thirty-four patients with LARC who underwent MRI scans before and after SCR followed by delayed surgery, retrospectively, were enrolled. SIS, ADC, IVIM parameters [tissue diffusion (D{sub t}), pseudo-diffusion (D{sub p}), perfusion fraction (f{sub p})] and DKI parameters [mean diffusivity (MD), mean of diffusional kurtosis (MK)] were calculated for each patient. IVIM parameters were estimated using two methods, namely conventional biexponential fitting (CBFM) and variable projection (VARPRO). After surgery, the pathological TNM and tumor regression grade (TRG) were estimated. For each parameter, percentage changes between before and after SCR were evaluated. Furthermore, an artificial neural network was trained for outcome prediction. Nonparametric sample tests and receiver operating characteristic curve (ROC) analysis were performed. Results: Fifteen patients were classified as responders (TRG ≤ 2) and 19 as not responders (TRG > 3). Seven patients had TRG 1 (pathological complete response, pCR). Mean and standard deviation values of pre-treatment CBFM D{sub p} and mean value of VARPRO D{sub p} pre-treatment showed statistically significant differences to predict pCR. (p value at Mann–Whitney test was 0.05, 0.03 and 0.008, respectively.) Exclusively SIS percentage change showed significant differences between responder and non-responder patients after SCR (p value << 0.001) and to assess pCR after SCR (p value << 0.001). The best results to predict pCR were obtained by VARPRO Fp mean value pre-treatment with area under ROC of 0.84, a sensitivity of 96.4%, a specificity of 71.4%, a positive predictive value (PPV) of 92.9%, a negative predictive value (NPV) of 83.3% and an accuracy of 91.2%. The best results to assess after treatment complete pathological response were obtained by SIS with an area under ROC of 0.89, a sensitivity of 85.7%, a specificity of 92.6%, a PPV of 75.0%, a NPV of 96.1% and an accuracy of 91.2%. Moreover, the best results to differentiate after treatment responders vs. non-responders were obtained by SIS with an area under ROC of 0.94, a sensitivity of 93.3%, a specificity of 84.2%, a PPV of 82.4%, a NPV of 94.1% and an accuracy of 88.2%. Promising initial results were obtained using a decision tree tested with all ADC, IVIM and DKI extracted parameter: we reached high accuracy to assess pathological complete response after SCR in LARC (an accuracy of 85.3% to assess pathological complete response after SCR using VARPRO D{sub p} mean value post-treatment, ADC standard deviation value pre-treatment, MD standard deviation value post-treatment). Conclusion: SIS is a hopeful DCE-MRI angiogenic biomarker to assess preoperative treatment response after SCR with delayed surgery. Furthermore, an important prognostic role was obtained by VARPRO F{sub p} mean value pre-treatment and by a decision tree composed by diffusion parameters derived by DWI and DKI to assess pathological complete response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp more effective than educational sessions at their own institutions. All of the residents (100%) would recommend this course to others. Conclusions: The ARC boot camp is an effective intervention for improving radiation oncology residents' knowledge and understanding of anatomy and radiology in addition to enhancing their confidence and accuracy in contouring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗