Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nondestructive measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal impacts on nondestructive analysis measurements of uranium hexafluoride

A series of nondestructive assay measurements were performed before, during, and after localized heating of an industrial standard 12B cylinder of uranium hexafluoride to replicate dose variations previously observed on commercial 30B cylinders. While cylinders represent a closed system, enrichment measurements may be impacted by altered uranium and daughter product distributions due to sublimation. A series of measurements were performed to examine localized heating impacts on dose rates, ratios of uranium and daughter product distributions, and measured 235 U enrichment as calculated by two different approaches. The less complex enrichment meter approaches were found to be more robust and less prone to deviation than isotope ratio approaches such as FRAM, but the impact can be minimized by using observable dose changes to avoid impacted areas.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Differential Exudation Creates Biogeochemically Distinct Microenvironments during Rhizosphere Evolution

Plant roots and associated microbes release a diverse range of functionally distinct exudates into the surrounding rhizosphere with direct impacts on soil carbon storage, nutrient availability, and contaminant dynamics. Yet mechanistic linkages between root exudation and emergent biogeochemical processes remain challenging to measure nondestructively, in real soil, over time. Here we used a novel combination of in situ microsensors with high-resolution mass spectrometry to measure, nondestructively, changing exudation and associated biogeochemical dynamics along single growing plant roots (Avena sativa). We found that metabolite and dissolved organic carbon (DOC) concentrations as well as microbial growth, redox potential (EH), and pH dynamics vary significantly among bulk soil, root tip, and more mature root zones. Surprisingly, the significant spike of rhizosphere DOC upon root tip emergence did not significantly correlate with any biogeochemical parameters. However, the presence of sugars significantly correlated with declines in EH following the arrival of the root tip, likely due to enhanced microbial oxygen demand. Similarly, the presence of organic acids significantly correlated to declines in pH upon root tip emergence. Altogether, our in situ measurements highlight how different exudates released along growing roots create functionally distinct soil microenvironments that evolve over time.

54 ENVIRONMENTAL SCIENCES↗

Heterogeneity effects on nondestructive assay measurements of enrichment in UF 6 cylinders

A set of measurements were performed using multiple mechanically cooled HPGe detectors at six positions around a cylinder uranium hexafluoride to assess if matrix inhomogeneity is detectible and effects the determined apparent uranium enrichment. These measurements were performed on nine 30B cylinders of uranium hexafluoride. Six of the cylinders appeared to be homogeneous and had similar apparent measured uranium enrichment, as calculated by the FRAM software, at all positions. However, three cylinders appeared to have local inhomogeneity based on the observed results. This was manifested as very low apparent enrichments, often <10% of the declared enrichment, on select positions. The side with a low apparent enrichment shows elevated daughter isotope activity (e.g., elevated 1001 keV and 766 keV peak count rate) and slightly reduced 235 U activity (lower 185.7 keV count rate). We hypothesize that these heterogenous cylinders may have experienced asymmetric solar heating, which caused volatile UF 6 to sublime preferentially away from the warmed side. A similar phenomenon was observed at a second facility where dose rate measurements confirm that the “low-enriched side” of cylinders show elevated gamma ray dose rates, likely from the removal of UF 6 attenuation and concentration of daughter-products. Care should be taken during uranium enrichment verification when applying methods that include gamma-rays associated with daughter nuclides to the determination of uranium enrichment on cylinders that are stored in sunlight and have asymmetric dose readings around the cylinder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RUScal : Software for the analysis of resonant ultrasound spectroscopy measurements

Resonant ultrasound spectroscopy is used to nondestructively measure the elastic resonances of small solids to elucidate the material's elastic properties or other qualities like size, shape, or composition. In this work, we introduce the software RUScal for the purpose of determining elastic properties by analyzing the eigenfrequencies of solid specimens with common shapes, such as rectangular parallelepipeds, cylinders (solid and hollow tube), ellipsoids, and octahedrons, as well as irregularly shaped ellipsoids that can be described analytically. All symmetry classes are supported, from isotropic to triclinic, along with the option to add or remove up to three orthogonal mirror planes as well as the ability to reorient the crystal axes with respect the sample edges via Euler angles. Additional features include tools to help find initial sets of elastic constants, including grid exploration and Monte Carlo methods, a tool to analyze frequencies as a function of sample length or crystal orientation, an error analysis tool to assess fit quality, and formatting of the input and output files for batch fitting, e.g., as a function of temperature. This software was validated with published resonant ultrasound spectroscopy data for various materials, shapes, and symmetries with noted improvements in calculation time compared to finite element methods.

47 OTHER INSTRUMENTATION↗

Spent fuel nondestructive assay integrated characterization from active neutron, passive neutron, and passive gamma

Spent nuclear fuel comprises a wide range of irradiated isotopic material compositions, and characterization through nondestructive measurements is beneficial in verifying declared parameters before the fuel is placed in storage, final disposal, and/or reprocessed. This paper discusses results from three nondestructive assay instruments, including passive gamma, passive neutron, and active neutron methods, that measured fifty spent fuel assemblies at the Clab interim storage facility in Sweden. Here, integrated analysis of the measurements from the three different instruments allowed parametric assessments of cooling time, burnup, neutron multiplication, fissile mass, initial enrichment, and decay heat of each individual fuel assembly. Passive gamma measurements were found to be the most beneficial in predicting cooling time, passive neutron for determining burnup, active neutron in estimating initial enrichment, and both passive and total neutron for multiplication correlations. Fissile mass was best estimated using any combination of any two of the instruments such that corrections for isotopic changes in the fuel could be accounted for with the first set of measurements and multiplication of the assembly in the second. In conclusion, the nondestructive assay technologies demonstrated through this effort enhance the characterization of spent nuclear fuel assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DEEPER: An Intergrated Platform for Deeper Roots

Crops with deeper roots would have multiple benefits, including better drought tolerance, reduced requirement for nitrogen fertilizer, and better sequestration of atmospheric CO 2 . DEEPER is an integrated platform of phenomic, genomic, and in silico technologies to generate maize lines with deeper roots. DEEPER is: LEADER (Leaf Elemental Accumulation from Deep Roots) is a breakthrough technology to nondestructively measure rooting depth by using the plant itself as a sensor. LEADER uses handheld X-ray Fluorescence spectrometry to quantify foliar accumulation of elements that are differentially distributed in the soil profile. LEADER is nondestructive and is orders of magnitude cheaper, faster, and more precise than any competing assay of rooting depth in the field. LEADER is able to distinguish deep-rooted from shallow-rooted maize lines in the field without the need for costly and noisy soil coring. RootRobot/DIRT3D, to automatically phenotype root architecture in any field, combining RootRobot, a mechatronics platform to excavate, clean, section, and image mature root crowns, with DIRT3D, software to quantify architectural traits in 3D. Anatomics, a high-throughput platform to phenotype root anatomy, combining LAT 2.0, a technology for 3D imaging of root anatomy and composition, with RootScan3D, software to automatically extract 3D anatomical and cell wall composition metrics from LAT 2.0 output. Using this platform we discovered two novel root traits, parenchyma cell wall thickness and multiseriate cortical sclerenchyma, that improve rooting depth and drought tolerance in maize and wheat. OpenSimRoot/Deep, software to simulate root interaction with hard subsoils. Using this platform we discovered novel concepts regarding how to increase crop rooting depth by modulating how individual root axes respond to hard soil. DeepGenes, a toolkit of genes, parent lines, and genomic selection strategies to enable breeding hybrids with deeper roots. We discovered 3 novel root genes that increase rooting depth in maize and wheat. DEEPER discovered novel root phenotypes for deeper rooting, and delivered validated ideotypes for deeper-rooted maize; novel technologies to rapidly assess root depth, root architecture and anatomy in field-grown plants; novel software tools for root modeling and 3D image analysis of root architecture and anatomy; and validated genes and genomic selection models to deploy traits for deeper rooting in maize breeding. Each DEEPER technology is transformative in its own right, and exceeds existing technologies. They are mutually synergistic, deployable for field-grown plants, and are ready for application. The phenotyping and modeling technologies are readily applicable to many crops, and genetic leads in maize may have utility in other grasses. Taken as a whole they represent a transformative platform to develop deeper-rooted crops, with greater drought tolerance, reduced fertilizer requirement, and greater carbon sequestration.

59 BASIC BIOLOGICAL SCIENCES↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

All the light we cannot see: Climate manipulations leave short and long‐term imprints in spectral reflectance of trees

Abstract Anthropogenic climate change, particularly changes in temperature and precipitation, affects plants in multiple ways. Because plants respond dynamically to stress and acclimate to changes in growing conditions, diagnosing quantitative plant‐environment relationships is a major challenge. One approach to this problem is to quantify leaf responses using spectral reflectance, which provides rapid, inexpensive, and nondestructive measurements that capture a wealth of information about genotype as well as phenotypic responses to the environment. However, it is unclear how warming and drought affect spectra. To address this gap, we used an open‐air field experiment that manipulates temperature and rainfall in 36 plots at two sites in the boreal‐temperate ecotone of northern Minnesota, USA. We collected leaf spectral reflectance (400–2400 nm) at the peak of the growing season for three consecutive years on juveniles (two to six years old) of five tree species planted within the experiment. We hypothesized that these mid‐season measurements of spectral reflectance capture a snapshot of the leaf phenotype encompassing a suite of physiological, structural, and biochemical responses to both long‐ and short‐time scale environmental conditions. We show that the imprint of environmental conditions experienced by plants hours to weeks before spectral measurements is linked to regions in the spectrum associated with stress, namely the water absorption regions of the near‐infrared and short‐wave infrared. In contrast, the environmental conditions plants experience during leaf development leave lasting imprints on the spectral profiles of leaves, attributable to leaf structure and chemistry (e.g., pigment content and associated ratios). Our analyses show that after accounting for baseline species spectral differences, spectral responses to the environment do not differ among the species. This suggests that building a general framework for understanding forest responses to climate change through spectral metrics may be possible, likely having broader implications if the common responses among species detected here represent a widespread phenomenon. Consequently, these results demonstrate that examining the entire spectrum of leaf reflectance for environmental imprints in contrast to single features (e.g., indices and traits) improves inferences about plant‐environment relationships, which is particularly important in times of unprecedented climate change.

Stefanski, Artur [Department of Forest Resources U↗

The calculation of light element impurity (α, n) yield curves in a PuO 2 matrix and associated specific yield coefficients: Influence of the reaction cross sections

Most of the Pu separated from irradiated commercial nuclear fuel is stored as PuO 2 . The primary quantitative nondestructive measurement technique used to verify the amount of Pu in storage containers is passive neutron correlation counting. An important physical property of the oxide material is the ratio, α, of the rate of (α, n) neutrons produced inside the item to the rate of neutrons produced by spontaneous fission. This ratio influences the precision of the correlated counting method and affects the interpretation of the data because of how it changes both the primary total neutron production rate and the rate of induced fission events taking place inside the item. In addition to the main O(α, n) contribution, additional contributions come from α-particle interactions with light element impurities that are inevitably present. In this work, we calculate specific (α, n) yield coefficients, expressed in units of neutrons per second per gram of α-emitting nuclide per part per million by mass of the specified impurity element distributed in a pure PuO 2 matrix, for some key α-emitting actinides commonly present in reprocessed Pu ( 238–242 Pu+ 241 Am). These coefficients are directly applicable to nuclear safeguards verification work in which the α ratio is often calculated from the Pu-isotopic composition and chemical information obtained by other means. Further, they also provide a convenient up-to-date reference set against which values generated by other methods can be compared. Results are presented for impurities with atomic number from 3 to 17 inclusive, plus K and Fe. In most cases, these coefficients are not expected to change by more than 5%–10% at any time in the future. However, as new data become available, changes as large as 20% may be needed for some targets (e.g., F). The present yield calculations are limited by the general shortage of quality experimental total (α, n) reaction cross section data, which, together with unexplained variation between determinations, means that an objective and coherent evaluation is not possible. The situation is even less satisfactory for the partial differential cross section needed to calculate neutron spectra.

(𝛼, n) reactions↗

Fast Preparation and Detection of a Rydberg Qubit Using Atomic Ensembles

Here, we demonstrate a new approach for fast preparation, manipulation, and collective readout of an atomic Rydberg-state qubit. By making use of Rydberg blockade inside a small atomic ensemble, we prepare a single qubit within 3 μs with a success probability of $F_p$ = 0.93 ± 0.02, rotate it, and read out its state in 6 μs with a single-shot fidelity of $F_d$ = 0.92 ± 0.04. The ensemble-assisted detection is 10 3 times faster than imaging of a single atom with the same optical resolution, and enables fast repeated nondestructive measurement. We observe qubit coherence times of 15 μs, much longer than the π rotation time of 90 ns. Potential applications ranging from faster quantum information processing in atom arrays to efficient implementation of quantum error correction are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Superradiance and Subradiance due to Quantum Interference of Entangled Free Electrons

When multiple quantum emitters radiate, their emission rate may be enhanced or suppressed due to collective interference in a process known as super- or subradiance. Such processes are well known to occur also in light emission from free electrons, known as coherent cathodoluminescence. Unlike atomic systems, free electrons have an unbounded energy spectrum, and, thus, all their emission mechanisms rely on electron recoil, in addition to the classical properties of the dielectric medium. To date, all experimental and theoretical studies of super- and subradiance from free electrons assumed only classical correlations between particles. However, dependence on quantum correlations, such as entanglement between free electrons, has not been studied. Recent advances in coherent shaping of free-electron wave functions motivate the investigation of such quantum regimes of super- and subradiance. In this Letter, we show how a pair of coincident path-entangled electrons can demonstrate either super- or subradiant light emission, depending on the two-particle wave function. By choosing different free-electron Bell states, the spectrum and emission pattern of the light can be reshaped, in a manner that cannot be accounted for by a classical mixed state. We show these results for light emission in any optical medium and discuss their generalization to many-body quantum states. Furthermore, our findings suggest that light emission can be sensitive to the explicit quantum state of the emitting matter wave and possibly serve as a nondestructive measurement scheme for measuring the quantum state of many-body systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison and investigation of production of specific nuclides by different fission yield data

Generally, passive gamma spectroscopy (PGS) is known as a useful technique for nondestructive measurement of burnup and nuclide production in normal spent nuclear fuel. However, PGS can be used not only for normal spent fuel, but also for molten fuel generated in severe accidents involving core meltdowns. In such cases, it is estimated by the radioactivity ratios of specific nuclides. At the time of the decommissioning of the Three Mile Island's unit 2 reactor, fission products (FPs) such as Cs{sup 134}, Cs{sup 137}, Ce{sup 144}, Eu{sup 154}, Ru{sup 106}, and Sb{sup 125} were concerned. The radioactivity ratios are estimated by numerical simulations. However, there are various uncertainties in numerical simulations. In this study, we evaluated the effect of the difference in fission yield data. We compared the productions of concerned nuclides of Three Mile Island's unit 2 reactor by using Tokyo-tech and JENDL FP Fission Yields Data File 2011(FPY- 2011). Tokyo-tech is newly created by Tsubakihara et al. at Tokyo Institute of Technology. FPY-2011 is currently the latest fission yield data in Japan. In the concerned nuclides, the relative difference (Tokyo-tech/FPY-2011 -1) in the production of Sb{sup 125} is 4.5% and that of Eu{sup 154} is -5.6%. The relative difference in the production of Sb{sup 125} is found to be caused by the difference in the independent yields of Sn{sup 125}, In{sup 125}, Cd{sup 125}, Ag{sup 125}, and Pd{sup 125}. The relative difference in Eu{sup 154} is found to be caused by the relative difference in the production of Sm{sup 152} and the relative difference in the cumulative yield of Eu{sup 153}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization and Speciation of Marine Materials Using Synchrotron Probes: Guidelines for New Users

Synchrotron instruments are useful for marine studies because they make nondestructive measurements of chemical composition and speciation on small sample volumes and at low concentrations. Synchrotron beamtime is available without cost using a peer-reviewed proposal system. New users do not have to be synchrotron radiation experts to design a good experiment, but some guidance is needed to design and propose appropriate experiments. Here we present some of that guidance to encourage and increase access to synchrotron facilities for marine science. We provide advice and examples from experts on how to access these instruments, choose the optimal sample preparation, and avoid common pitfalls. We then present some examples of successful marine studies that use these techniques.

36 MATERIALS SCIENCE↗

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast, Nondestructive and Precise Biomass Measurements Are Possible Using Lidar-Based Convex Hull and Voxelization Algorithms

Light detection and ranging (lidar) scanning tools are available that can make rapid digital estimations of biomass. Voxelization and convex hull are two algorithms used to calculate the volume of the scanned plant canopy, which is correlated with biomass, often the primary trait of interest. Voxelization splits the scans into regular-sized cubes, or voxels, whereas the convex hull algorithm creates a polygon mesh around the outermost points of the point cloud and calculates the volume within that mesh. In this study, digital estimates of biomass were correlated against hand-harvested biomass for field-grown corn, broom corn, and energy sorghum. Voxelization (r = 0.92) and convex hull (r = 0.95) both correlated well with plant dry biomass. Lidar data were also collected in a large breeding trial with nearly 900 genotypes of energy sorghum. In contrast to the manual harvest studies, digital biomass estimations correlated poorly with yield collected from a forage harvester for both voxel count (r = 0.32) and convex hull volume (r = 0.39). However, further analysis showed that the coefficient of variation (CV, a measure of variability) for harvester-based estimates of biomass was greater than the CV of the voxel and convex-hull-based biomass estimates, indicating that poor correlation was due to harvester imprecision, not digital estimations. Overall, results indicate that the lidar-based digital biomass estimates presented here are comparable or more precise than current approaches.

Environmental Sciences & Ecology↗

A new mechanism for void-cascade interaction from nondestructive depth-resolved atomic-scale measurements of ion irradiation–induced defects in Fe

The nondestructive investigation of single vacancies and vacancy clusters in ion-irradiated samples requires a depth-resolved probe with atomic sensitivity to defects. The recent development of short-pulsed positron beams provides such a probe. Here, we combine depth-resolved Doppler broadening and positron annihilation lifetime spectroscopies to identify vacancy clusters in ion-irradiated Fe and measure their density as a function of depth. Despite large concentrations of dislocations and voids in the pristine samples, positron annihilation measurements uncovered the structure of vacancy clusters and the change in their size and density with irradiation dose. When combined with transmission electron microscopy measurements, the study demonstrates an association between the increase in the density of small vacancy clusters with irradiation and a remarkable reduction in the size of large voids. This, previously unknown, mechanism for the interaction of cascade damage with voids in ion-irradiated materials is a consequence of the high porosity of the initial microstructure.

36 MATERIALS SCIENCE↗

Structure-Driven Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The rhizosphere is the narrow region of soil surrounding the roots of plants that is influenced by root exudates, root secretions, and associated microbial communities. This region is crucial to plant growth and development and plays a critical role in nutrient uptake, disease resistance, and soil transformation. Understanding the function of exogenous compounds in the rhizosphere starts with determining the spatiotemporal distribution of these molecular components. Using liquid microjunction surface-sampling probe mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes enables in situ, nondisruptive, and nondestructive spatiotemporal measurement of exogenous compounds from plant roots. However, long imaging times (>2 h) can negatively affect plant heath and limit temporal studies. Here, we present a novel strategy to optimize the number and location of sampling sites on these microporous membrane-covered microfluidic devices. In conclusion, this novel, “structure-driven” sampling workflow takes into consideration the channel structure of the microfluidic device to maximize sampling from the channels and minimize acquisition time (~4× less time in some cases while providing similar chemical image accuracy), thus reducing stress on plants during in situ LMJ-SSP-MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗