Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “non-invasive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estimating Trabecular Bone Mechanical Properties From Non-Invasive Imaging

An important component in developing countermeasures for maintaining musculoskeletal integrity during long-term space flight is an effective and meaningful method of monitoring skeletal condition. Magnetic resonance imaging (MRI) is an attractive non-invasive approach because it avoids the exposure to radiation associated with X-ray based imaging and also provides measures related to bone microstructure rather than just density. The purpose of the research for the 1996 Summer Faculty Fellowship period was to extend the usefulness of the MRI data to estimate the mechanical properties of trabecular bone. The main mechanical properties of interest are the elastic modulus and ultimate strength. Correlations are being investigated between these and fractal analysis parameters, MRI relaxation times, apparent densities, and bone mineral densities. Bone specimens from both human and equine donors have been studied initially to ensure high-quality MR images. Specimens were prepared and scanned from human proximal tibia bones as well as the equine distal radius. The quality of the images from the human bone appeared compromised due to freezing artifact, so only equine bone was included in subsequent procedures since these specimens could be acquired and imaged fresh before being frozen. MRI scans were made spanning a 3.6 cm length on each of 5 equine distal radius specimens. The images were then sent to Dr. Raj Acharya of the State University of New York at Buffalo for fractal analysis. Each piece was cut into 3 slabs approximately 1.2 cm thick and high-resolution contact radiographs were made to provide images for comparing fractal analysis with MR images. Dual energy X-ray absorptiometry (DEXA) scans were also made of each slab for subsequent bone mineral density determination. Slabs were cut into cubes for mechanical using a slow-speed diamond blade wafering saw (Buehler Isomet). The dimensions and wet weights of each cube specimen were measured and recorded. Wet weights were also recorded. Each specimen was labeled and marked to denote anatomic orientations, i.e. superior/inferior (S/I), media/lateral (M/L), and anterior/posterior (A/P). The actual locations of each cube cut were documented and images distributed to define ROI locations for other analyses (to Raj Acharya for fractal analysis, to Jon Richardson at Baylor College of Medicine for DEXA, and to Chen Lin at Baylor College of Medicine for T2* MRI analysis). Quasistatic mechanical testing consisted of compressive loading in all three mutually perpendicular anatomic directions. Cyclic loading was applied for 10 cycles to precondition the specimen and results calculated for the eleventh. For one of three directions tested on each specimen, the 10 cycles were followed with loading to failure. Testing is currently proceeding and once completed the results will be correlated with data from the other analyses. One of the main points of interest is the relationship between fractal dimension and mechanical properties. Throughout preparation and testing all specimens were maintained hydrated with physiological saline and stored frozen when not being used.

Hogan, Harry A.↗

Survey Plan For Characterization of the Subsurface Underlying the National Aeronautics and Space Administration's Marshall Space Flight Center in Huntsville, Alabama

Topic considered include: survey objectives; technologies for non-Invasive imaging of subsurface; cost; data requirements and sources; climatic condition; hydrology and geology; chemicals; magnetometry; electrical(resistivity, potential); optical-style imaging; reflection/refraction seismics; gravitometry; photo-acoustic activation;well drilling and borehole analysis; comparative assessment matrix; ground sensors; choice of the neutron sources; logistic of operations; system requirements; health and safety plans.

Source record↗

Alterations in Cardiovascular Regulation and Function During Long-Term Simulated Microgravity

The Cardiovascular Alterations Team is conducting studies of hemodynamic regulation and susceptibility to arrhythmias resulting from sixteen days of simulated microgravity exposure. In these studies very intensive measurements are made during a short duration of bed rest. In this collaborative effort are making many of the same measurements, however much less frequently, on subjects who are exposed to a much longer duration of simulated microgravity. Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In addition, numerous reports from the past 30 years suggest that the incidence of ventricular arrhythmias among astronauts is increased during space flight. However, the effects of space flight and the associated physiologic stresses on cardiac conduction processes are not known, and an increase in cardiac susceptibility to arrhythmias has never been quantified. In this project we are applying the most powerful technologies available to determine, in a ground-based study of long duration space flight, the mechanisms by which space flight affects cardiovascular function, and then on the basis of an understanding of these mechanisms to develop rational and specific countermeasures. To this end we are conducting a collaborative project with the Bone Demineralization/Calcium Metabolism Team of the National Space Biomedical Research Institute (NSBRI). The Bone Team is conducting bed rest studies in human subjects lasting 17 weeks, which provides a unique opportunity to study the effects of long duration microgravity exposure on the human cardiovascular system. We are applying a number of powerful new methods to these long term bed rest subjects, including cardiovascular system identification (CSI), microvolt level T wave alternans analysis, and cardiac magnetic resonance imaging to assess non-invasively the effects of simulated long duration space flight on the cardiovascular system.

Cohen, Richard J.↗

Ultrasound Techniques for Space Applications

Ultrasound has proven to be a safe non-invasive technique for imaging organs and measuring cardiovascular function. It has unique advantages for application to problems with man in space including evaluation of cardiovascular function both in serial studies and during critical operations. In addition, specialized instrumentation may be capable of detecting the onset of decompression sickness during EVA activities. A spatial location and three-dimensional reconstruction system is being developed to improve the accuracy and reproducibility for serial comparative ultrasound studies of cardiovascular function. The three-dimensional method permits the acquisition of ultrasonic images from many views that can be recombined into a single reconstruction of the heart or vasculature. In addition to conventional imaging and monitoring systems, it is sometimes necessary or desirable to develop instrumentation for special purposes. One example of this type of development is the design of a pulsed-Doppler system to monitor cerebral blood flow during critical operations such as re-entry. A second example is the design of a swept-frequency ultrasound system for the detection of bubbles in the circulatory system and/or soft tissues as an early indication of the onset of decompression sickness during EVA activities. This system exploits the resonant properties of bubbles and can detect both fundamental and second harmonic emissions from the insonified region.

Rooney, James A.↗

Porosity and Permeability of Chondritic Materials

We have investigated the porosity of a large number of chondritic interplanetary dust particles and meteorites by three techniques: standard liquid/gas flow techniques, a new, non-invasive ultrasonic technique, and image processing of backscattered images . The latter technique is obviously best suited to sub-kg sized samples. We have also measured the gas and liquid permeabilities of some chondrites by two techniques: standard liquid/gas flow techniques, and a new, non-destructive pressure release technique. We find that chondritic IDP's have a somewhat bimodal porosity distribution. Peaks are present at 0 and 4% porosity; a tail then extends to 53%. These values suggest IDP bulk densities of 1.1 to 3.3 g/cc. Type 1-3 chondrite matrix porosities range up to 30%, with a peak at 2%. The bulk porosities for type 1-3 chondrites have the same approximate range as exhibited by matrix, indicating that other components of the bulk meteorites (including chondrules and aggregates) have the same average porosity as matrix. These results reveal that the porosity of primitive materials at scales ranging from nanogram to kilogram are similar, implying similar accretion dynamics operated through 12 orders of size magnitude. Permeabilities of the investigated chondrites vary by several orders of magnitude, and there appears to be no simple dependence of permeability with degree of aqueous alteration, or chondrite type.

Zolensky, Michael E.↗

MRI Measurements and Granular Dynamics Simulation of Segregation of Granular Mixture

A counter intuitive axial segregation phenomenon in a rotating horizontal cylinder has recently captured attention of many researchers in different disciplines. There is a growing consensus that the interplay between the particle dynamics and the evolution of the internal structure during the segregation process must be carefully investigated. Magnetic resonance imaging (MRI) has been used to non-invasively obtain much needed dynamic/static information such as velocity and concentration profiles, and it has proven to be capable of depicting the evolution of segregation processes. Segregation in a rotating cylinder involves two processes: the first is to transport small particles in the radial direction to form a radial core, and the second is to transform the radial core into axially segregated bands. Percolation and/or "stopping" have been proposed as mechanisms for the radial segregation. As to mechanisms for axial band formation, much less is known. The difference in the dynamic angle of repose has been proposed to segregate different components in the axial direction. Recently, Hill and Kakalios have reported that particles mix or demix depending upon the competition between diffusion and preferential drift whose order can be determined by the dynamic angle of repose through the adjustment of the rotation rate. We claim that the dynamic angle of repose could be one of the causes, however, it fails to offer reasonable explanations for certain aspects of the axial migration. For example, we always observe that the radial segregation precedes the axial segregation and small particles migrate in the radial direction to form an axially extended radial core. It then transforms into axially segregated bands. By definition, the effects of the dynamic angle of repose are restricted near the free surface where the flowing layer is present. However, during the process of transforming from the radially segregated core to axially segregated bands, small particles located in the deep core region, which is untouched by the flowing layer, also completely disappear. Usually, the dynamics angle of repose are uniquely defined for individual species to characterize particle properties, and the dynamic angle of repose thus defined provides little information for the dynamic angle of repose of the mixture since the concentration ratio and the internal packing structure do not remain the same during the segregation processes. Under microgravity environment, the dynamics angle of repose argument does not hold since there is simply no flowing layer to influence/determine the preferred directions of segregation. We have thus designed an experiment so that the effects of the dynamic angle of repose can be minimized by filling the cylinder almost completely full. Small particles still formed a radial core and also migrated to form axial bands. As ground based experiments we have designed and conducted both 2D and 3D segregation experiments. The 2D experiments are performed using a thin cylinder (the gap between two end caps is about 5 mm) filled with different combinations of particles. The 3D experiments are conducted with a long cylinder of its length and diameter of 27cm and 7cm, respectively. Results of 2D experiments indicate that different mechanisms govern particle motion in regions near and far from the axis of rotation. Results of 3D experiments indicate that a series of collapses of microstructures of particle packing (micro-collapses) may be responsible for the creation of voids for small particles to migrate through in the axial direction. We have successfully eliminated the dynamic angle of repose as a cause for segregation, however, by almost completely filling the cylinder with the particles, we have lost an opportunity to investigate a possibility of particle "mobility" being a cause for segregation which requires a flowing surface but not the difference in the angle of repose. This is currently being investigated.

Nakagawa, M.↗

Magnetic resonance imaging after exposure to microgravity

A number of physiological changes were demonstrated in bone, muscle, and blood from exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long-duration space missions is an important NASA goal. Historically, NASA has had to rely on tape measures, x-ray, and metabolic balance studies with collection of excreta and blood specimens to obtain this information. The development of magnetic resonance imaging (MRI) offers the possibility of greatly extending these early studies in ways not previously possible; MRI is also non-invasive and safe; i.e., no radiation exposure. MRI provides both superb anatomical images for volume measurements of individual structures and quantification of chemical/physical changes induced in the examined tissues. This investigation will apply MRI technology to measure muscle, intervertebral disc, and bone marrow changes resulting from exposure to microgravity.

Leblanc, Adrian↗

An Experimental Investigation on the Static Equilibria and Dynamics of Liquid Bridges

A liquid bridge is a volume of liquid held between two or more solid supports. In the case of small disk supports with a sharp edge, the contact line between the bridge and the support disk will be anchored along the edge of the disk. For these cases the solid presents a geometrical singularity and the contact angle is indeterminate within a given range. This dissertation presents research conducted on liquid bridges with anchored contact lines. The three major topics covered are: determining the role of support geometry on static equilibria, liquid bridge dynamical behavior, and forces exerted by a liquid bridge on a support structure. The work was primarily experimental and conducted in a "Plateau tank" that allowed for the simulation of equivalent low-gravity conditions. The main thrust of the experimental work involved the use of a high resolution optical measurement system for imaging the dynamic zone shape, measurement of the static and dynamic contact angles and non-invasive analysis of excited surface modes. The liquid bridge was manipulated by computer controlled linear actuators which allowed precise control over the physical characteristics of the bridge. Experiments have been carried out to locate a bifurcation point along the maximum volume axisymmetric stability margin. Below the critical slenderness the bifurcation from an axisymmetric to a stable nonaxisymmetric configuration is supercritical. However, above this critical slenderness, the bifurcation is subcritical. A series of experiments analyzed the effect on axisymmetric bridge stability by using support disks of different radii, The shape behavior as transition points were approached, as well as the limiting case of a vanishing support radius was investigated. Experiments were performed to determine the resonant frequencies of axisymmetric bridges subject to lateral vibrations. Anomolous results led to a series of experiments to characterize nonlinearities present in the dynamic bridge shape. Finally, an attempt was made to experimentally measure the force exerted by the bridge on the lower support disk. This was done through use of a force balance apparatus. Particular attention was paid to the behavior of the bridge as the minimum volume stability limit was approached.

Resnick, Andrew Howard↗

Characterization of Semiconductor Materials Using AOTF Instruments

A non-invasive characterization of silicon-on-insulator (SOI) wafers using white light interference measured by an AOTF polarimetric hyperspectral imaging instrument will be presented an an illustration of the technology potential. Experiments provided high resolution thickness maps of both silicon and oxide layers with accuracy and observed optically active imperfections and distributions in the structure.

polarimetric hyperspectral imaging silicon oxide↗

EVA Glove Research Team

The goal of the basic research portion of the extravehicular activity (EVA) glove research program is to gain a greater understanding of the kinematics of the hand, the characteristics of the pressurized EVA glove, and the interaction of the two. Examination of the literature showed that there existed no acceptable, non-invasive method of obtaining accurate biomechanical data on the hand. For this reason a project was initiated to develop magnetic resonance imaging as a tool for biomechanical data acquisition and visualization. Literature reviews also revealed a lack of practical modeling methods for fabric structures, so a basic science research program was also initiated in this area.

Strauss, Alvin M.↗

Spherical Camera

Developed largely through a Small Business Innovation Research contract through Langley Research Center, Interactive Picture Corporation's IPIX technology provides spherical photography, a panoramic 360-degrees. NASA found the technology appropriate for use in guiding space robots, in the space shuttle and space station programs, as well as research in cryogenic wind tunnels and for remote docking of spacecraft. Images of any location are captured in their entirety in a 360-degree immersive digital representation. The viewer can navigate to any desired direction within the image. Several car manufacturers already use IPIX to give viewers a look at their latest line-up of automobiles. Another application is for non-invasive surgeries. By using OmniScope, surgeons can look more closely at various parts of an organ with medical viewing instruments now in use. Potential applications of IPIX technology include viewing of homes for sale, hotel accommodations, museum sites, news events, and sports stadiums.

Source record↗

Method for improved prediction of bone fracture risk using bone mineral density in structural analysis

A non-invasive in-vivo method of analyzing a bone for fracture risk includes obtaining data from the bone such as by computed tomography or projection imaging which data represents a measure of bone material characteristics such as bone mineral density. The distribution of the bone material characteristics is used to generate a finite element method (FEM) mesh from which load capability of the bone can be determined. In determining load capability, the bone is mathematically compressed, and stress, strain force, force/area versus bone material characteristics are determined.

Cann, Christopher E.↗

NMRI Measurements of Flow of Granular Mixtures

We investigate complex 3D behavior of granular mixtures in shaking and shearing devices. NMRI can non-invasively measure concentration, velocity, and velocity fluctuations of flows of suitable particles. We investigate origins of wall-shear induced convection flow of single component particles by measuring the flow and fluctuating motion of particles near rough boundaries. We also investigate if a mixture of different size particles segregate into their own species under the influence of external shaking and shearing disturbances. These non-invasive measurements will reveal true nature of convecting flow properties and wall disturbance. For experiments in a reduced gravity environment, we will design a light weight NMR imager. The proof of principle development will prepare for the construction of a complete spaceborne system to perform experiments in space.

Nakagawa, Masami↗

Trabecular Bone Mechanical Properties and Fractal Dimension

Countermeasures for reducing bone loss and muscle atrophy due to extended exposure to the microgravity environment of space are continuing to be developed and improved. An important component of this effort is finite element modeling of the lower extremity and spinal column. These models will permit analysis and evaluation specific to each individual and thereby provide more efficient and effective exercise protocols. Inflight countermeasures and post-flight rehabilitation can then be customized and targeted on a case-by-case basis. Recent Summer Faculty Fellowship participants have focused upon finite element mesh generation, muscle force estimation, and fractal calculations of trabecular bone microstructure. Methods have been developed for generating the three-dimensional geometry of the femur from serial section magnetic resonance images (MRI). The use of MRI as an imaging modality avoids excessive exposure to radiation associated with X-ray based methods. These images can also detect trabecular bone microstructure and architecture. The goal of the current research is to determine the degree to which the fractal dimension of trabecular architecture can be used to predict the mechanical properties of trabecular bone tissue. The elastic modulus and the ultimate strength (or strain) can then be estimated from non-invasive, non-radiating imaging and incorporated into the finite element models to more accurately represent the bone tissue of each individual of interest. Trabecular bone specimens from the proximal tibia are being studied in this first phase of the work. Detailed protocols and procedures have been developed for carrying test specimens through all of the steps of a multi-faceted test program. The test program begins with MRI and X-ray imaging of the whole bones before excising a smaller workpiece from the proximal tibia region. High resolution MRI scans are then made and the piece further cut into slabs (roughly 1 cm thick). The slabs are X-rayed again and also scanned using dual-energy X-ray absorptiometry (DEXA). Cube specimens are then cut from the slabs and tested mechanically in compression. Correlations between mechanical properties and fractal dimension will then be examined to assess and quantify the predictive capability of the fractal calculations.

Hogan, Harry A.↗

Non-invasive assessment of otolith formation during development of the Japanese red-bellied newt, Cynops pyrrhogaster

Pre-mated adult female newts and embryos have been flown on the International Microgravity Laboratory-2 (IML-2) Space Shuttle flight in 1994 (Wiederhold et al., 1992b). With the specimens available from this flight, the calcification of otoliths, ulna, radius and backbone of the flown larvae and adult newts were analyzed. The experiments presented here studied the development of the otoliths on the ground. Otoliths of living newts, from embryo to adult, were observed in situ with the application of a new X-ray and bio-imaging analyzer system. For the establishment of this method, newts at different developmental stages were used. An imaging plate temporarily stores the X-ray energy pattern at the bio-imaging analyzer. A latent image on the imaging plate was transformed into a digital time series signal with an image reader. Acquired digital information was computed with the image processor. The processed information was recorded on film with an image recorder, in order to visualize it on an enlargement computed radiograph. To analyze development of the otoliths, photo-stimulated luminescence level was detected by an image analyzer, using transmitted X-ray photons. A single clump of otoconia could first be seen at stage 33. Stage-36 embryos first have distinguishable otoliths, with the utricle in front and saccule behind. Our results show that this X-ray method detects the otoliths equally as well as sectioning. In the newt, the mandibular/maxillary bone formed before the spine. It is suspected that for the newt embryo, living in water, feeding becomes necessary prior to support of the body.

NASA Discipline Neuroscience↗

Predicting Bone Mechanical Properties of Cancellous Bone from DXA, MRI, and Fractal Dimensional Measurements

This project was aimed at making predictions of bone mechanical properties from non-invasive DXA and MRI measurements. Given the bone mechanical properties, stress calculations can be made to compare normal bone stresses to the stresses developed in exercise countermeasures against bone loss during space flight. These calculations in turn will be used to assess whether mechanical factors can explain bone loss in space. In this study we assessed the use of T2(sup *) MRI imaging, DXA, and fractal dimensional analysis to predict strength and stiffness in cancellous bone.

Harrigan, Timothy P.↗

Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

Buckey, J. C.↗

The identification of the variation of atherosclerosis plaques by invasive and non-invasive methods

Computer-enhanced visualization of coronary arteries and lesions within them is discussed, comparing invasive and noninvasive methods. Trial design factors in computer lesions assessment are briefly discussed, and the use of the computer edge-tracking technique in that assessment is described. The results of a small pilot study conducted on serial cineangiograms of men with premature atherosclerosis are presented. A canine study to determine the feasibility of quantifying atherosclerosis from intravenous carotid angiograms is discussed. Comparative error for arterial and venous injection in the canines is determined, and the mode of processing the films to achieve better visualization is described. The application of the computer edge-tracking technique to an ultrasound image of the human carotid artery is also shown and briefly discussed.

Selzer, R. H.↗