Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “non-intrusive sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In-Flight Gain Monitoring of SPIDER’s Transition-Edge Sensor Arrays

We report experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES’s small-signal power response from its electrical response that is exact in the limit of strong electrothermal feedback. We discuss the application and validation of this method using flight data from SPIDER, a balloon-borne telescope that observes the polarization of the cosmic microwave background with more than 2000 TESs. This method may prove useful for future balloon- and space-based instruments, where observing time and ground control bandwidth are limited.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Sensitivity study

Power towers, a type of concentrating power tower technology, use a large number of heliostats to concentrate sunlight and produce renewable energy. Optical errors of heliostats can cause drastic losses in the efficiency of power-tower plants. Accurately measuring optical errors is crucial to assessing and improving plant performance. This analysis discusses an innovate non-intrusive optical (NIO) approach to measure slope, canting, and tracking errors by detecting distortions in the reflected tower structure in heliostat images. Further in this work a sensitivity study is carefully conducted to determine the uncertainty requirements to allow the method to calculate slope errors with an accuracy of 0.25 mrad. Measurement uncertainty sources include camera resolution and position uncertainty, tower position uncertainty, and number of collected images. Each uncertainty source is investigated to determine its impact on the accuracy of the slope-error calculation. A combination of theoretical results and experimental results obtained from data collected on a heliostat at Sandia National Laboratories is used to determine and validate uncertainty requirements. The analysis shows that a measurement uncertainty of 0.25 mrad can be realized by realistically controlling uncertainty sources when implementing the NIO method. It demonstrates the superior performance of NIO in performing in-situ optical characterization.

14 SOLAR ENERGY↗

UQTk User Manual (V.3.1.0)

The UQ Toolkit (UQTk) is a collection of libraries and tools for the quantification of uncertainty in numerical model predictions. Version 3.1.0 offers intrusive and non-intrusive methods for propagating input uncertainties through computational models, tools for sensitivity analysis, methods for sparse surrogate construction, and Bayesian inference tools for inferring parameters from experimental data. This manual discusses the download and installation process for UQTk, provides pointers to the UQ methods used in the toolkit, and describes some of the examples provided with the toolkit.

97 MATHEMATICS AND COMPUTING↗

UQTk Version 3.1.1 User Manual

The UQ Toolkit (UQTk) is a collection of libraries and tools for the quantification of uncertainty in numerical model predictions. Version 3.1.1 offers intrusive and non-intrusive methods for propagating input uncertainties through computational models, tools for sensitivity analysis, methods for sparse surrogate construction, and Bayesian inference tools for inferring parameters from experimental data. This manual discusses the download and installation process for UQTk, provides pointers to the UQ methods used in the toolkit, and describes some of the examples provided with the toolkit.

97 MATHEMATICS AND COMPUTING↗

UQTk Version 3.1.2 User Manual

The UQ Toolkit (UQTk) is a collection of libraries and tools for the quantification of uncertainty in numerical model predictions. Version 3.1.2 offers intrusive and non-intrusive methods for propagating input uncertainties through computational models, tools for sensitivity analysis, methods for sparse surrogate construction, and Bayesian inference tools for inferring parameters from experimental data. This manual discusses the download and installation process for UQTk, provides pointers to the UQ methods used in the toolkit, and describes some of the examples provided with the toolkit.

97 MATHEMATICS AND COMPUTING↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

A semiempirical transparency model for dual energy cargo radiography applications

Cargo containers passing through ports are scanned by non-intrusive inspection systems to search for concealed illicit materials. By using two photon beams with different energy spectra, dual energy inspection systems are sensitive to both the area density and the atomic number of cargo contents. Most literature on the subject assumes a simple exponential attenuation model for photon intensity in which only free streaming photons are detected. However, this approximation neglects second order effects such as scattering, leading to a biased model and thus incorrect material predictions. This work studies the accuracy of the free streaming model by comparing it to simulation outputs, finding that the model shows poor atomic number reconstruction accuracy at high- Z and suffers significantly if the source energy spectra and detector response function are not known exactly. To address these challenges, this work introduces a semiempirical transparency model which modifies the free streaming model by rescaling different components of the mass attenuation coefficient, allowing the model to capture secondary effects ignored by the free streaming model. The semiempirical model displays improvement agreement with simulated results at high- Z and shows excellent extrapolation to materials and thicknesses which were not included during the calibration step. Furthermore, this work demonstrates that the semiempirical model yields accurate atomic number predictions even when the source spectra and detector response are not known exactly. In conclusion, using the semiempirical model, manufacturers can perform a simple calibration to enable more precise Z reconstruction capabilities, which has the potential to significantly improve the performance of existing dual energy radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of model parameters in MFiX particle-in-cell approach

The limitations in numerical treatment of solids-phase in conventional methods like Discrete Element Model and Two-Fluid Model have facilitated the development of alternative techniques such as Particle-In-Cell (PIC). However, a number of parameters are involved in PIC due to its empiricism. In this work, global sensitivity analysis of PIC model parameters is performed under three distinct operating regimes common in chemical engineering applications, viz. settling bed, bubbling fluidized bed and circulating fluidized bed. Simulations were performed using the PIC method in Multiphase Flow with Interphase eXchanges (MFiX) developed by National Energy Technology Laboratory (NETL). A non-intrusive uncertainty quantification (UQ) based approach is applied using Nodeworks to first construct an adequate surrogate model and then identify the most influential parameters in each case. This knowledge will aid in developing an effective design of experiments and determine optimal parameters through techniques such as deterministic or statistical calibration.

01 COAL, LIGNITE, AND PEAT↗

Final Report On Non-Intrusive Load Monitoring Of Welding Processes

The conventional method of weld process monitoring is to monitor the process output electrical power close to the point of welding. Non-Intrusive Load Monitoring (NILM) describes the method of monitoring primary or utility electrical power into a welding process well away from the point of welding. The objective of this project was to determine if there is sufficient information within the welding process input power to understand process output power characteristics, and, if so, determine if there is sufficient resolution within the input electrical characteristics to infer some measures of weld quality. To understand the relationship between process input and output power, both input and output power were monitored for two welding processes (GMAW and GTAW) and two different power source types (inverter and SCR). Welds were made with and without intentional disturbances. The results showed that there is a strong correlation between input and output power and that the influence of process disturbances are evident within the input power. A simple method using input power only was devised and successfully demonstrated to discriminate between a weld made with no intentional disturbance (a nominal weld) from a weld made with an intentional disturbance (off-nominal weld). The primary conclusions of this work is that NILM of process input power is sensitive to process disturbances that could influence weld quality and that the approach warrants additional study.

36 MATERIALS SCIENCE↗

Uncertainty propagation in pore water chemical composition calculation using surrogate models

Performance assessment in deep geological nuclear waste repository systems necessitates an extended knowledge of the pore water chemical conditions prevailing in host-rock formations. In the last two decades, important progress has been made in the experimental characterization and thermodynamic modeling of pore water speciation, but the influence of experimental artifacts and uncertainties of thermodynamic input parameters are seldom evaluated. In this respect, we conducted an uncertainty propagation study in a reference geochemical model describing the pore water chemistry of the Callovian-Oxfordian clay formation. Nineteen model input parameters were perturbed, including those associated to experimental characterization (leached anions, exchanged cations, cation exchange selectivity coefficients) and those associated to generic thermodynamic databases (solubilities). A set of 13 quantities of interest were studied by the use of polynomial chaos expansions built non-intrusively with a least-squares forward stepwise regression approach. Training and validation sets of simulations were carried out using the geochemical speciation code PHREEQC. The statistical results explored the marginal distribution of each quantity of interest, their bivariate correlations as well as their global sensitivity indices. The influence of the assumed distributions for input parameters uncertainties was evaluated by considering two parametric domain sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity Analysis of Particle-In-Cell Modeling Parameters in Settling Bed, Bubbling Fluidized Bed and Circulating Fluidized Bed

The objective of the work presented is to perform a preliminary sensitivity analysis of particle-in-cell (PIC) model parameters when applied to settling bed, bubbling fluidized bed, and circulating fluidized bed simulations. These examples correspond to widely different flow conditions commonly seen in chemical engineering applications. Simulations were performed using the PIC method in the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). As part of the non-intrusive uncertainty quantification (UQ) analysis, simulation campaigns were generated using Nodeworks. Sampling locations or settings for PIC model parameters were determined using the Latin Hypercube method. Response surfaces were created using radial basis functions (RBF), and Sobol’ indices were estimated to quantify the influence of model parameters on the quantities of interest (QoI). This study marks a first step towards systematically determining optimal ranges for model parameters used in MFiX-PIC. Based on limited experience, it is expected that these values would depend strongly on flow conditions. Given the complexity of the multiphase flow systems under analysis, a non-intrusive UQ based approach is used to identify the most influential parameters in each case. This prior knowledge will help in proposing an effective design of experiments (DoE) and determine optimal parameters through techniques such as deterministic or Bayesian calibration, which will be pursued in the future.

42 ENGINEERING↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Methodology and in-situ validation

No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.

14 SOLAR ENERGY↗

Complete Strain Mapping of Nanosheets of Tantalum Disulfide

Quasi-two-dimensional (quasi-2D) materials hold promise for future electronics because of their unique band structuresthat result in electronic and mechanical properties sensitive to crystal strains in all three dimensions. Quantifying crystal strain is a prerequisite to correlating it with the performance of the device, and calls for high resolution but spatially resolved rapid characterization methods. Here we show that using fly-scan nano X-ray diffraction we can accomplish a tensile strain sensitivity below 0.001% with a spatial resolution of better than 80 nm over a spatial extent of 100 µm on quasi 2D flakes of 1T-TaS2. Coherent diffraction patterns were collected from a ~100 nm thick sheet of 1T-TaS2 by scanning 12keV focused X-ray beam across and rotating the sample. We demonstrate that the strain distribution around micron and sub-micron sized ‘bubbles’ that are present in the sample may be reconstructed from these images. The experiments use state of the art synchrotron instrumentation, and will allow rapid and non-intrusive strain mapping of thin film samples and electronic devices based on quasi 2D materials.

nano X-ray diffraction↗

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Verification of the sensitivity and uncertainty-based criticality safety validation techniques: ORNL’s SCALE case study

The use of sensitivity and uncertainty-based techniques has been well-developed in the neutronic community for criticality safety applications. Sensitivity techniques calculate the first-order relative variations in keff due to relative cross-section variations by isotope, reaction type, and incident neutron energy. The result is a vector of sensitivity coefficients which is folded with prior cross-section uncertainties to calculate the so-called similarity indices. Similarity indices are integral quantities which serve as useful mathematical measures for assessing the relevance of existing or new experiments to given application conditions, representing design systems for which the models are to be validated. Despite their importance for a wide range of validation activities, the peer-reviewed literature is non-existent on the development of rigorous verification analysis for their calculated values. Thus, this manuscript proposes a simple non-intrusive method to calculate similarity indices, serving as an independent verification tool for their evaluation. The manuscript derives the theoretical basis for the proposed verification analysis. Next, the verification analysis is applied to the ORNL’s SCALE code suite which employs adjoint-based methods to calculate similarity indices. Numerical experiments using a number of well-known benchmark experiments are employed to verify the calculation of the similarity indices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sampling and resolution characteristics in reduced order models of shallow water equations: Intrusive vs nonintrusive

We investigate the sensitivity of reduced order models (ROMs) to training data spatial resolution as well as sampling rate. In particular, we consider proper orthogonal decomposition (POD), coupled with Galerkin projection (POD-GP), as an intrusive reduced order modeling technique. For non-intrusive ROMs, we consider two frameworks. The first is using dynamic mode decomposition (DMD), and the second is based on artificial neural networks (ANNs). For ANN, we utilized a residual deep neural network, and for DMD we have studied two versions of DMD approaches; one with hard thresholding and the other with sorted bases selection. Also, we highlight the differences between mean-subtracting the data (centering) and using the data without mean-subtraction. We tested these ROMs using a system of 2D shallow water equations for four different numerical experiments, adopting combinations of sampling rates and spatial resolutions. For these cases, we found that the DMD basis obtained with hard threshodling is sensitive to sampling rate. The sorted DMD algorithm helps to mitigate this problem and yields more stabilized and converging solution. Furthermore, we demonstrate that both DMD approaches without mean subtraction provide significantly more accurate results than DMD with mean-subtracting the data. On the other hand, POD is relatively insensitive to sampling rate and yields better representation of the flow field. Meanwhile, spatial resolution has little effect on both POD and DMD performances. Here, the numerical results reveal that an ANN on POD subspace (POD-ANN) performs remarkably better than POD-GP and DMD in capturing system dynamics, even with a small number of modes.

42 ENGINEERING↗

A New Reflected Target Optical Assessment System: Stage 1 Development Results

NREL has completed stage 1 development of an indoor optical measurement tool for fully assembled heliostats and single facets. This tool began as an indoor version of NREL’s outdoor Non-Intrusive Optical (NIO) measurement technique [1]. It uses similar techniques to other available tools (deflectometry, photogrammetry, etc.), but is designed to require very little infrastructure, labor, and time to set up and collect surface slope and canting measurements, making it a valuable tool for quality assurance and laboratory measurement of heliostat optics. It accomplishes this by using computer vision, photogrammetry, and multiple images stitched together to minimize the printed target size and required setup precision. This adaptable setup is useful for taking measurements at a variety of heliostat pointing angles, and for measuring fully assembled heliostats on the assembly line. In this paper, we describe the methodology behind the measurement system, present an initial analysis of its uncertainty and sensitivity, and compare it with established optical measurement systems.

Kesseli, Devon (ORCID:0000000193113036)↗

Numerical study of pure rotational fs/ps CARS coherence beating at high pressure and for multi-species rotation-vibration non-equilibrium thermometry

Coherent anti-Stokes Raman scattering (CARS) has long been the gold standard for non-intrusively measuring gas temperature in reacting flows such as flames and plasmas. Recently, the development of ultrafast hybrid fs/ps CARS has enabled the exploitation of coherence beating between neighboring spectral lines to simultaneously measure rotational and vibrational temperatures from a single pure rotational spectrum. However, the influence of non-Boltzmann vibrational state distributions and limitations due to collisional dephasing at pressures greater than 1 atm remains unclear. In this work, we use spectral simulations to investigate the effects of non-Boltzmann vibrational state distributions and the applicability of coherence beating at pressures up to 10 atm. We show that short probe pulses can be leveraged to quantify non-Boltzmann vibrational state distributions of N2. Furthermore, we demonstrate that fs/ps CARS coherence beating can simultaneously provide sensitive measurements of rotational and vibrational temperatures of both O2 and N2 in air. A sensitivity analysis was conducted to qualitatively explain the accuracy and precision comparisons between probe delays.

Chen, Timothy Y. (ORCID:0000000330269767)↗