Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “non-intrusive load monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report On Non-Intrusive Load Monitoring Of Welding Processes

The conventional method of weld process monitoring is to monitor the process output electrical power close to the point of welding. Non-Intrusive Load Monitoring (NILM) describes the method of monitoring primary or utility electrical power into a welding process well away from the point of welding. The objective of this project was to determine if there is sufficient information within the welding process input power to understand process output power characteristics, and, if so, determine if there is sufficient resolution within the input electrical characteristics to infer some measures of weld quality. To understand the relationship between process input and output power, both input and output power were monitored for two welding processes (GMAW and GTAW) and two different power source types (inverter and SCR). Welds were made with and without intentional disturbances. The results showed that there is a strong correlation between input and output power and that the influence of process disturbances are evident within the input power. A simple method using input power only was devised and successfully demonstrated to discriminate between a weld made with no intentional disturbance (a nominal weld) from a weld made with an intentional disturbance (off-nominal weld). The primary conclusions of this work is that NILM of process input power is sensitive to process disturbances that could influence weld quality and that the approach warrants additional study.

36 MATERIALS SCIENCE↗

Non-Intrusive Load Monitoring of EBW Processes A Second Study [Slides]

The Objective is to Determine if induced off-nominal welding disturbances: (1) Beam arc out (weld on high vapor pressure aluminum plate); (2) Pulsed beam voltage; (3) Pulsed beam current; and (4) Pulsed beam focus current can be observed in the input power to the high-voltage cabinet powering the EB gun, ie Non-Instrusive Load Monitoring (NILM).

36 MATERIALS SCIENCE↗

Lockdown impacts on residential electricity demand in India: A data-driven and non-intrusive load monitoring study using Gaussian mixture models

This study evaluates the effect of complete nationwide lockdown in 2020 on residential electricity demand across 13 Indian cities and the role of digitalisation using a public smart meter dataset. We undertake a data-driven approach to explore the energy impacts of work-from-home norms across five dwelling typologies. Our methodology includes climate correction, dimensionality reduction and machine learning-based clustering using Gaussian Mixture Models of daily load curves. Results show that during the lockdown, maximum daily peak demand increased by 150-200% as compared to 2018 and 2019 levels for one room-units (RM1), one bedroom-units (BR1) and two bedroom-units (BR2) which are typical for low- and middle-income families. While the upper-middle- and higher-income dwelling units (i.e., three (3BR) and more-than-three bedroom-units (M3BR)) saw night-time demand rise by almost 44% in 2020, as compared to 2018 and 2019 levels. Our results also showed that new peak demand emerged for the lockdown period for RM1, BR1 and BR2 dwelling typologies. We found that the lack of supporting socioeconomic and climatic data can restrict a comprehensive analysis of demand shocks using similar public datasets, which informed policy implications for India's digitalisation. We further emphasised improving the data quality and reliability for effective data-centric policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Robustness of Spectrogram Classifiers with Neural Stochastic Differential Equations

Signal analysis and classification is fraught with high levels of noise and perturbation. Computer-vision-based deep learning models applied to spectrograms have proven useful in the field of signal classification and detection; however, these methods aren't designed to handle the low signal-to-noise ratios inherent within non-vision signal processing tasks. While they are powerful, they are currently not the method of choice in the inherently noisy and dynamic critical infrastructure domain, such as smart-grid sensing, anomaly detection, and non-intrusive load monitoring. Currently, these models can be brittle, which makes them susceptible to noisy input. This also means they have sub-optimal stability of explanation outputs. Experts and technicians using these models to make decisions in real world scenarios need assurance that a model is performing as it is supposed to. The classification or prediction outputs it generates should be sound and grounded, not likely to change in the presence of shifting noise landscapes. In this work, we explore the idea of Neural Stochastic Differential Equations (NSDE's) to improve the robustness of models trained to classify time series data and the effect of NSDE's on the explainability of outputs. We then test the effectiveness of these approaches by applying them to a non-intrusive load monitoring (NILM) dataset that consists of simulated harmonic signals injected into a real building.

Brogan, Joel↗

MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗

Harmonic Signals Dataset

The Harmonic Signals Dataset (HSD) consists of one-dimensional time series data collected from current sensors with a goal of providing data for research and development of Non-Intrusive Load Monitoring (NILM) with high sample rate (800kHz) sensors. NILM seeks to detect and characterize electrical equipment operating within a facility by sensing changes in electrical current on the building power system associated with the equipment. To provide data with a known ground truth, but with the realism of a signal introduced within a building facility, a series of known ground truth signals were injected as voltage into the power system of a building and measurements of the signals at multiple locations across the building power system were made with electrical current sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Contextually Supervised Optimization-Based HVAC Load Disaggregation Methodology

This paper presents a novel contextually supervised optimization-based approach for disaggregating heating, ventilation, and air-conditioning (HVAC) loads using smart meter or Supervisory Control and Data Acquisition data. To disaggregate the load into HVAC loads, large and infrequently used loads (LIUL), and base loads, we formulate an optimization problem to minimize a set of five loss terms, consisting of the reconstruction errors of the overall load profile, the ramp rate losses, and three distinct loss functions linked with the HVAC load, base load, and LIUL, respectively. To enhance accuracy, we incorporate two forms of contextual information into the problem formulation. First, we utilize mutual information to estimate HVAC energy consumption. Second, we employ a base load dictionary to constrain HVAC load estimation errors. The obtained HVAC load profiles are fine-tuned by abnormal ramp detection followed by binary hypothesis testing. Here, the proposed method is developed and tested using sub-metered residential and commercial building data. Simulation results show that the proposed method outperforms existing methods across various data resolutions and load aggregation levels, showing excellent transferability and generalizability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensing Service Transformer Secondary Currents using Planar Magnetic Pick-up Coils

The rapid deployment of distributed energy resources (DERs) is creating stresses on utility assets in the distribution networks. The service transformer, which is the most commonly used utility asset is often not monitored, since the cost of available sensing solutions is as high as the transformer itself. This paper presents a method to use an array of printed circuit board coils to intelligently monitor North American pole top service transformers. The approach, uses a novel, self-calibrating algorithm to infer the fixed geometry of the installation, by recording data over an extended period of time. The proposed method can enable rapid installation of a non-intrusive sensor that can be used to monitor loading levels of the distribution transformer. Furthermore, these sensors can help in planning, prognostics and advanced situational awareness for utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Non-Intrusive Appliance Identification with Appliance-Specific Networks

The problem of noninstrusive load monitoring (NILM) is usually formulated as a single-channel blind source separation task, whose successful solution enable fast and convenient load identification and energy disaggregation. When applied at test time, NILM algorithms aim to identify the operating characteristics of individual appliances from an aggregate power measurement of the entire house. Recent advances in deep learning gave rise to many methods that mostly focus on learning a direct mapping from aggregate measurement to individual appliance power. However, these methods are not only computationally expensive, but they often suffer from overfitting and do not generalize very well. In this article, we propose a novel NILM method that leverages advances in statistical learning that have not been properly applied in this domain before. The proposed method consists of three stages: first, a Bayesian nonparametric learning-based approach for appliance state extraction; second, synthetic minority oversampling technique for data augmentation and mitigating the heavy imbalance in switching events; and third, appliance-specific lightweight long short-term memory networks for status classification for each appliance. Here, we adopt a “differential” input (the difference before and after the switching event) to reduce the complexity of network training and make the proposed method robust to multiappliance switching events. Experiments are conducted to demonstrate the effectiveness of the proposed method, achieving superior performance when compared to recent methods. An ablation study is conducted to demonstrate the effectiveness of each module of our method. Finally, we investigate the quality of generated synthetic samples.

42 ENGINEERING↗

Asset Monitoring using Smart Sensing and Advanced Analytics for the Distribution Network

As the electric grid transitions into a highly distributed and intelligent grid, electric utilities are becoming increasingly concerned with monitoring the health and performance of their distribution assets. As Internet of Things technologies and data analytics become inexpensive and ubiquitous, low-cost asset monitoring becomes more feasible. Moreover, using edge analytics, computations can be off-loaded to these intelligent sensors to report only actionable information to the cloud. This needs to be done in a highly distributed manner using non-intrusive sensors and device physics that seamlessly integrates with legacy infrastructure. Here, this paper reviews existing sensor based solutions, identifies t heir issues, proposes a novel solution by exploring the required attributes and proposes an approach for low-cost distribution transformer health monitoring.

Asset monitoring↗

A Scalable Online Monitoring System Based on Elasticsearch for Distributed Data Acquisition in Cms

The part of the CMS Data Acquisition (DAQ) system responsible for data readout and event building is a complex network of interdependent distributed applications. To ensure successful data taking, these programs have to be constantly monitored in order to facilitate the timeliness of necessary corrections in case of any deviation from specified behaviour. A large number of diverse monitoring data samples are periodically collected from multiple sources across the network. Monitoring data are kept in memory for online operations and optionally stored on disk for post-mortem analysis. We present a generic, reusable solution based on an open source NoSQL database, Elasticsearch, which is fully compatible and non-intrusive with respect to the existing system. The motivation is to benefit from an off the-shelf software to facilitate the development, maintenance and support efforts. Elasticsearch provides failover and data redundancy capabilities as well as a programming language independent JSON-over-HTTP interface. The possibility of horizontal scaling matches the requirements of a DAQ monitoring system. The data load from all sources is balanced by redistribution over an Elasticsearch cluster that can be hosted on a computer cloud. In order to achieve the necessary robustness and to validate the scalability of the approach the above monitoring solution currently runs in parallel with an existing in-house developed DAQ monitoring system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗