Engineering PapersSearch

SEARCH · Engineering Papers

Results for “non-destructive assay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Non-Destructive Plutonium Assay in Pyroprocessing Bulk Materials with a 3D Boron-Coated-Straw Detector Array

Assessment of plutonium content through all the processing steps is needed and is a challenging task. While several destructive assay methods have been developed for nuclear material accountability, a nondestructive assay (NDA) system for the assessment of plutonium in bulk materials is still needed. This system should withstand pyroprocessing harsh environments and have consistent sensitivity and accuracy despite different fuel form factors. We aim to enable the accurate assessment of the plutonium content of nuclear material during pyroprocessing to improve the separation process and enhance its proliferation resistance. We plan to achieve this goal by developing and demonstrating a new 3D boron-coated-straw neutron detector array (3D-BCSDA) with high efficiency and spatial resolution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

New NDA Methods for Thorium Fuel Cycle Safeguards (Final Report)

This project developed portable Neutron Resonance Transmission Analysis (pNRTA) as a new non-destructive assay (NDA) method for thorium fuel cycles safeguards and other applications where multiple isotopes must be measured when present together. pNRTA leverages epithermal neutron resonances to assay multiple safeguards-relevant isotopes (e.g., 233 U and 235 U) when they are present together in a sample. Existing techniques are challenged by this task, driving the need for new active interrogation methods. With selected detectors, pNRTA works in high gamma-ray backgrounds from fission and activation products and 232 U progeny expected in thorium fuel cycle samples. This project leveraged a pNRTA system developed at Pacific Northwest National Laboratory (PNNL) and collaboration with the Massachusetts Institute of Technology (MIT). The system uses a commercially available deuterium-tritium (DT) neutron generator at short standoff (2 m). Key achievements in this project included: first-of-a-kind pNRTA quantitative measurements of 233 U oxide samples, an assessment of neutron detector technologies suitable for pNRTA in high gamma-ray background environments, experimentally demonstrating quantitative assay of samples containing 233 U and 235 U, and modeling studies showing the applicability of pNRTA to a wide range of material forms. Further, a custom algorithm was developed at MIT, which provided mean bias of 9% and relative standard deviation of 36% in assaying 233 U, 235 U, 238 U, and 232 Th content in eight measured samples. These outcomes form a solid technical basis for pNRTA as a new promising capability for international safeguards verification that is portable, non-destructive, quantitative, and isotopic specific.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Data-Driven Optimization of Pixelated CdZnTe Spectrometers for Uranium Enrichment Assay

Here, in recent work [Vavrek et al. (2025)], we developed the performance optimization framework spectre-ml for gamma spectrometers with variable performance across many readout channels. The framework uses non-negative matrix factorization (NMF) and clustering to learn groups of similarly-performing channels and sweep through various learned channel combinations to optimize the performance tradeoff of including worse-performing channels for better total efficiency. In this work, we integrate the pyGEM uranium enrichment assay code with our spectre-ml framework, and show that the U-235 enrichment relative uncertainty can be directly used as an optimization target. We find that this optimization reduces relative uncertainties after a 30 -minute measurement by an average of 20%, as tested on six different H3D M400 CdZnTe spectrometers, which can significantly improve uranium non-destructive assay measurement times in nuclear safeguards contexts. Additionally, this work demonstrates that the spect re-ml optimization framework can accommodate arbitrary end-user spectroscopic analysis code and performance metrics, enabling future optimizations for complex Pu spectra.

Gamma-ray detection

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution

Radiation Monitoring for Volatilized Zinc Contamination Using Gamma-Ray Imaging and Spectroscopy

Gamma-ray imaging is a tool that has grown in importance in the applications of non-destructive assay (NDA) for radioactive survey and analysis of nuclear facilities. Imaging techniques have shown great promise in providing valuable information involving radioactive waste management and contamination prevention. For the application studied in this work, 65 Zn has been identified as a radioactive contaminant during tritium extraction. Due to the volatile nature of 65 Zn under the pressure and temperature changes during extraction operations, 65 Zn can easily travel through components of the extraction system as vapor, making it difficult to trap. Previous research involving the development of a filtration system showed that the 65 Zn can be trapped, mitigating product contamination. However, during the extraction process, direct analysis of the equipment to confirm that zinc contamination is trapped in the filter and has not spread to other components is impractical. Here, in this situation, the need to assay the location of the contamination with little-to-no interference with operations is vital. In this work, we demonstrate the use of a commercialized 3D position-sensitive CdZnTe (CZT) gamma-ray imaging spectrometer to provide analysis of the 65 Zn contamination. Onsite measurements during an extraction process are studied to assess the location and migration of the 65 Zn. The results obtained from real-time glovebox monitoring demonstrate the feasibility of gamma-ray imaging for localizing the contamination and providing a preliminary qualitative assessment that is intended to be used in future work quantifying the contamination build-up and activity over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Variance Preserving Spectral Subsampling

Generating statistically faithful short-duration gamma-ray spectra from a single long measurement is essential in nuclear safeguards, supporting tasks such as algorithm development and machine-learning applications, especially when list-mode data are unavailable. Existing subsampling methods often distort the statistical characteristics of genuine short-duration measurements, leading to biased or unreliable analytical outcomes and thereby undermining downstream tasks. In this work, we compare five subsampling approaches using a benchmark set of 156 genuine replicate spectra collected with a high-purity germanium detector. We evaluate each method with respect to run-to-run variance, channel-to-channel variance, and preservation of total counts (losslessness). Across a wide range of subsampling ratios, only binomial subsampling without replacement consistently reproduces the statistical properties of genuine short-duration spectra, maintaining proper dispersion even in sparse spectral regions and perfectly preserving total counts. These results provide a mathematically principled and practically validated framework for generating synthetically shortened spectra when true short-duration measurements are unavailable.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P