Distributionally Robust Variational Quantum Algorithms With Shifted Noise

Given their potential to demonstrate near-term quantum advantage, variational quantum algorithms (VQAs) have been extensively studied. Although numerous techniques have been developed for VQA parameter optimization, it remains a significant challenge. A practical issue is the high sensitivity of quantum noise to environmental changes, and its propensity to shift in real time. This presents a critical problem as an optimized VQA ansatz may not perform effectively under a different noise environment. For the first time, we explore how to optimize VQA parameters to be robust against unknown shifted noise. We model the noise level as a random variable with an unknown probability density function (PDF), and we assume that the PDF may shift within an uncertainty set. This assumption guides us to formulate a distributionally robust optimization problem, with the goal of finding parameters that maintain effectiveness under shifted noise. We utilize a distributionally robust Bayesian optimization solver for our proposed formulation. This provides numerical evidence in both the Quantum Approximate Optimization Algorithm (QAOA) and the Variational Quantum Eigensolver (VQE) with hardware-efficient ansatz, indicating that we can identify parameters that perform more robustly under shifted noise. We regard this work as the first step towards improving the reliability of VQAs influenced by real-time noise.

97 MATHEMATICS AND COMPUTING↗

Improving Robustness of Spectrogram Classifiers with Neural Stochastic Differential Equations

Signal analysis and classification is fraught with high levels of noise and perturbation. Computer-vision-based deep learning models applied to spectrograms have proven useful in the field of signal classification and detection; however, these methods aren't designed to handle the low signal-to-noise ratios inherent within non-vision signal processing tasks. While they are powerful, they are currently not the method of choice in the inherently noisy and dynamic critical infrastructure domain, such as smart-grid sensing, anomaly detection, and non-intrusive load monitoring. Currently, these models can be brittle, which makes them susceptible to noisy input. This also means they have sub-optimal stability of explanation outputs. Experts and technicians using these models to make decisions in real world scenarios need assurance that a model is performing as it is supposed to. The classification or prediction outputs it generates should be sound and grounded, not likely to change in the presence of shifting noise landscapes. In this work, we explore the idea of Neural Stochastic Differential Equations (NSDE's) to improve the robustness of models trained to classify time series data and the effect of NSDE's on the explainability of outputs. We then test the effectiveness of these approaches by applying them to a non-intrusive load monitoring (NILM) dataset that consists of simulated harmonic signals injected into a real building.

Brogan, Joel↗

Assessing Membership Inference Attacks under Distribution Shifts

Membership inference attacks (MIAs) exploit machine learning models to infer whether a data point was in the training set, posing significant privacy risks even with limited black-box access. These attacks rely on the attacker approximating the target model’s training distribution, yet the impact of distribution shifts between target and shadow models on MIA success remains underexplored. We systematically evaluate five types of distribution shifts —-cutout, jitter, Gaussian noise, label shift, and attribute shift —- at varying intensities. Our results reveal that these shifts affect MIA effectiveness in nuanced ways, with some reducing attack success while others exacerbate vulnerabilities, and the same shift can have opposite effects depending on the type of MIA. This highlights the complex interplay between distributional differences and attack performance, offering critical insights for improving model defenses against MIAs.

Shi, Yichuan [Massachusetts Institute of Technolog↗

SIDDA: SInkhorn Dynamic Domain Adaptation for image classification with equivariant neural networks

Modern neural networks (NNs) often do not generalize well in the presence of a ‘covariate shift’; that is, in situations where the training and test data distributions differ, but the conditional distribution of classification labels given the data remains unchanged. In such cases, NN generalization can be reduced to a problem of learning more robust, domain-invariant features. Domain adaptation (DA) methods include a broad range of techniques aimed at achieving this; however, these methods have struggled with the need for extensive hyperparameter tuning, which then incurs significant computational costs. In this work, we introduce SInkhorn Dynamic Domain Adaptation (SIDDA), an out-of-the-box DA training algorithm built upon the Sinkhorn divergence, that can achieve effective domain alignment with minimal hyperparameter tuning and computational overhead. We demonstrate the efficacy of our method on multiple simulated and real datasets of varying complexity, including simple shapes, handwritten digits, real astronomical observations, and remote sensing data. These datasets exhibit covariate shifts due to noise, blurring, differences between telescopes, and variations in imaging wavelengths. SIDDA is compatible with a variety of NN architectures, and it works particularly well in improving classification accuracy and model calibration when paired with symmetry-aware equivariant NNs (ENNs). We find that SIDDA consistently enhances the generalization capabilities of NNs, achieving up to a ${\approx}40\%$ improvement in classification accuracy on unlabeled target data, while also providing a more modest performance gain of $\lesssim 1\%$ on labeled source data. We also study the efficacy of DA on ENNs with respect to the varying group orders of the dihedral group DN, and find that the model performance improves as the degree of equivariance increases. Finally, if SIDDA achieves proper domain alignment, it also enhances model calibration on both source and target data, with the most significant gains in the unlabeled target domain—achieving over an order of magnitude improvement in the expected calibration error and Brier score. SIDDA’s versatility across various NN models and datasets, combined with its automated approach to domain alignment, has the potential to significantly advance multi-dataset studies by enabling the development of highly generalizable models.

79 ASTRONOMY AND ASTROPHYSICS↗

FolpsD: combining EFT and phenomenological approaches for joint power spectrum and bispectrum analyses

We present a theoretical model for the power spectrum and bispectrum of galaxy clustering that exploits the complementarity between small-scale power spectrum information and large-scale bispectrum measurements. We extend the FOLPS code by combining its one-loop EFT galaxy power spectrum with a tree-level galaxy bispectrum projected onto the tripolar spherical harmonics (Sugiyama) basis. To access additional small-scale information, we also consider a line-of-sight damping factor in both statistics, mirroring approaches commonly used in studies of redshift-space distortions. We test the model using DESI DR2 galaxy mocks. Even without damping, the joint analysis of the EFT power spectrum and bispectrum significantly improves constraints and reduces parameter degeneracies relative to power spectrum analyses alone. For LRG-like samples, including the damping further extends the range beyond $k\sim 0.3 \,h \text{Mpc}^{-1}$ in the power spectrum and $k \sim 0.24 \,h \text{Mpc}^{-1}$ in the bispectrum without introducing statistically significant parameter biases. This leads to up to $\sim 30\%$ tighter constraints on $A_s$ and $ω_{cdm}$. For low signal-to-noise tracers such as QSOs, however, the damping parameters are weakly constrained and can absorb noise fluctuations, leading to shifts in inferred parameters. Similar limitations may arise in models where cosmological information is encoded in power-spectrum shape features degenerate with the damping, such as scenarios with massive neutrinos. In contrast, for $w_0w_a$CDM we obtain $15\%$ and $21\%$ tighter constraints on $w_0$ and $w_a$, respectively, yielding a deviation from constant dark energy at slightly more than the $1σ$ level using full-shape information alone. The code is publicly available at https://github.com/cosmodesi/FolpsD

Bansal, P. [Michigan U., MCTP; Michigan U.] (ORCID↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scattering phase shifts from a quantum computer

We calculate two-body scattering phase shifts on a quantum computer using a leading order short-range effective field theory Hamiltonian. The algorithm combines the variational quantum eigensolver and the quantum subspace expansion. As an example, we consider scattering in the deuteron 3S1 partial wave. We calculate scattering phase shifts with a quantum simulator and on real hardware. Here, we also study how noise impacts these calculations and discuss noise mitigation required to extend our work to larger quantum processing units. With current hardware, up to five superconducting qubits can produce acceptable results, and larger calculations will require a significant noise reduction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Algorithms for Non-Negative Matrix Factorization on Noisy Data With Negative Values

Non-negative matrix factorization (NMF) is a dimensionality reduction technique that has shown promise for analyzing noisy data, especially astronomical data. For these datasets, the observed data may contain negative values due to noise even when the true underlying physical signal is strictly positive. Prior NMF work has not treated negative data in a statistically consistent manner, which becomes problematic for low signal-to-noise data with many negative values. In this paper we present two algorithms, Shift-NMF and Nearly-NMF, that can handle both the noisiness of the input data and also any introduced negativity. Both of these algorithms use the negative data space without clipping or masking and recover non-negative signals without any introduced positive offset that occurs when clipping or masking negative data. We demonstrate this numerically on both simple and more realistic examples, and prove that both algorithms have monotonically decreasing update rules.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative Evaluation of Spectral Methods for Robust Reactor Noise Estimation

Reactor noise analysis provides a noninvasive means to determine neutron kinetic parameters from stochastic fluctuations in detector signals. However, standard cross-power spectral density (CPSD) analyses can be sensitive to numerical processing choices, which may introduce processing-dependent systematic shifts in estimates of the prompt neutron decay constant (α) and limit reproducibility. This study uses a hybrid multitaper–Welch spectral estimator to analyze subcritical noise measurements from a fast-spectrum critical assembly. The decay constant α was extracted using three frequency-domain methods: the CPSD, the magnitude-squared coherence (MSC), and the generalized magnitude-squared coherence (GMSC). These coherence-based estimators normalize detector auto-spectral structure and are expected to reduce the sensitivity of fitted α values to processing parameters. A Sobol global sensitivity analysis identified which numerical inputs most strongly influence the fitted values of α. All estimators produced a linear dependence of α on inverse count rate, with delayed-critical extrapolations near 1.7 × 10 4 s −1 , in agreement within 8% of MCNP6.3 KOPTS benchmark calculations. Sensitivity results show that while the CPSD depends on both time-bin width and taper selection, the MSC and GMSC are dominated by time-bin width alone, indicating reduced parameter coupling and greater robustness to processing variability. These findings demonstrate the feasibility and practical value of coherence-based spectral estimators for extracting α from reactor noise and support their broader application to multi-detector and irregular datasets in subcritical system characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)↗

Measuring and unbiasing the BAO shift in the Ly α forest with AbacusSummit

ABSTRACT The Dark Energy Spectroscopic Instrument (DESI) places sub- per cent constraints on measurements of the Baryon Acoustic Oscillation (BAO) scaling parameters from the Ly $\alpha$ forest. However, no systematic error budget stemming from non-linearities in the three-dimensional clustering of the Ly $\alpha$ forest is included in the DESI-Ly $\alpha$ analysis. In this work, we measure the size of the shift of the BAO peak using large Ly $\alpha$ forest mocks produced on the N-body simulation suite AbacusSummit, which adopt the Fluctuating–Gunn–Peterson Approximation (FGPA). Specifically, we measure the Ly $\alpha$ autocorrelation and the Ly $\alpha$-quasar cross-correlation functions. To mitigate the noise, we adopt a linear control variates technique, reducing the error bars by a factor of up to $\sim \sqrt{50}$ on large scales. From the autocorrelation, we detect a small positive shift in radial direction of $\Delta \alpha _{\parallel }= 0.35~{{\ \rm per\ cent}}$ at the 3$\sigma$ level and virtually no shift in the transverse direction, $\alpha _\perp$. From the cross-correlation, we see a similar shift to $\Delta \alpha _\parallel$, albeit with larger error bars, and a small negative shift, $\Delta \alpha _{\perp }=\sim$0.25 per cent, at the 2$\sigma$ level. We also make a connection with the Ly $\alpha$ forest effective field theory (EFT) framework and find that the one-loop EFT power spectrum yields unbiased measurements of the BAO shift parameters in radial and transverse direction for Ly $\alpha$ auto- and the Ly $\alpha$-quasar cross-correlation measurements. When using the one-loop EFT framework, we find that we can recover the BAO parameters without a shift, which has important implications for future Ly $\alpha$ forest analyses based on EFT. This work paves the way for novel full-shape analyses of the currently observing DESI and future surveys such as the PFS, WEAVE-QSO, and 4MOST.

Hadzhiyska, Boryana↗

Effect of Gamma Radiation on TaOₓ ECRAM

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. Here, this work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaO x -based ECRAM up to 17.3 Mrad(SiO 2 ) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaO x -based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

ECRAM↗

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

Evaluation of phase shifts for nonrelativistic elastic scattering using quantum computers

Simulations of scattering processes are essential in understanding the physics of our universe. Computing relevant scattering quantities from ab initio methods is extremely difficult on classical devices because of the substantial computational resources needed. Here, this work reports the development of an algorithm that makes it possible to obtain phase shifts for generic nonrelativistic elastic scattering processes on a quantum computer. This algorithm is based on extracting phase shifts from the direct implementation of the real-time evolution. The algorithm is improved by a variational procedure making it more accurate and resistant to the quantum noise. The reliability of the algorithm is first demonstrated by means of classical numerical simulations for different potentials and later tested on existing quantum hardware, specifically on IBM quantum processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗