Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noise exposure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Noise Level Hazards due to Agricultural Equipment in a Laboratory

Noise exposure is a common health hazard in the agricultural field due to the continuous use of large pieces of equipment. In lab settings it is not as common to noise exposure due to industrial scale equipment. However, the energy system laboratories at INL are exploring new and inventive ways to create energy from biomaterials. This process requires the use of large pieces of agricultural equipment such as hammer mills, shakers, conveyor belts, etc. As the researchers continuously refine this process, they not only test the limits of renewable resources for energy but also test the noise exposure threshold limits. The purpose of this project was to determine the noise level hazards which are present due to the use of large agricultural equipment in a laboratory setting.

99 GENERAL AND MISCELLANEOUS↗

Absorption of Axion Dark Matter in a Magnetized Medium

Detection of axion dark matter heavier than an meV is hindered by its small wavelength, which limits the useful volume of traditional experiments. This problem can be avoided by directly detecting in-medium excitations, whose ∼ meV – eV energies are decoupled from the detector size. We show that for any target inside a magnetic field, the absorption rate of electromagnetically coupled axions into in-medium excitations is determined by the dielectric function. As a result, the plethora of candidate targets previously identified for sub-GeV dark matter searches can be repurposed as broadband axion detectors. We find that a kg yr exposure with noise levels comparable to recent measurements is sufficient to probe parameter space currently unexplored by laboratory tests. Noise reduction by only a few orders of magnitude can enable sensitivity to the QCD axion in the ∼ 10 meV – 10 eV mass range. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hearing Loss and Dementia

This report is an OSH-DO Safety Action Bulletin that briefly discusses the link between dementia and hearing loss. The bulletin provides some basic statistics, hearing loss protection guidelines and resources for more information on the topic.

99 GENERAL AND MISCELLANEOUS↗

Impact Noise Monitoring at Site 9940: RD-24 Shots

The purpose of this sampling event was to determine if the observation point (inside the MFCP) could be relocated from 74 feet away to 21 feet from ground zero and to determine how much attenuation is provided by the MFCP. The MFCP provides noise attenuation to ensure Members of the Workforce (MOW) exposure to impact noise is below the Occupational Exposure Limit (OEL) of 140 dBC. The MFCP will be used for future tests under similar configurations. Please note that during each test shot, MOW was located inside MFCP that was 74 feet from ground zero and donned hearing protection (e.g., ear plugs with a minimum noise reduction rating of 23).

42 ENGINEERING↗

Robustness of deep learning algorithms in astronomy -- galaxy morphology studies

Deep learning models are being increasingly adopted in wide array of scientific domains, especially to handle high-dimensionality and volume of the scientific data. However, these models tend to be brittle due to their complexity and overparametrization, especially to the inadvertent adversarial perturbations that can appear due to common image processing such as compression or blurring that are often seen with real scientific data. It is crucial to understand this brittleness and develop models robust to these adversarial perturbations. To this end, we study the effect of observational noise from the exposure time, as well as the worst case scenario of a one-pixel attack as a proxy for compression or telescope errors on performance of ResNet18 trained to distinguish between galaxies of different morphologies in LSST mock data. We also explore how domain adaptation techniques can help improve model robustness in case of this type of naturally occurring attacks and help scientists build more trustworthy and stable models.

79 ASTRONOMY AND ASTROPHYSICS↗

The hyperplane of early-type galaxies: using stellar population properties to increase the precision and accuracy of the fundamental plane as a distance indicator

ABSTRACT We use deep spectroscopy from the SAMI (Sydney-AAO Multi-object Integral) Galaxy Survey to explore the precision of the fundamental plane (FP) of early-type galaxies as a distance indicator for future single-fibre spectroscopy surveys. We study the optimal trade-off between sample size and signal-to-noise ratio (SNR), and investigate which additional observables can be used to construct hyperplanes with smaller intrinsic scatter than the FP. We add increasing levels of random noise (parametrized as effective exposure time) to the SAMI spectra to study the effect of increasing measurement uncertainties on the FP- and hyperplane-inferred distances. We find that, using direct-fit methods, the values of the FP and hyperplane best-fitting coefficients depend on the spectral SNR, and reach asymptotic values for a mean $\langle \mathrm{ SNR} \rangle =40\, \mathrm{\mathring{\rm A}}^{-1}$. As additional variables for the FP we consider three stellar-population observables: light-weighted age, stellar mass-to-light ratio, and a novel combination of Lick indices ($I_\mathrm{age}$). For an $\langle \mathrm{ SNR} \rangle =45~\mathrm{\mathring{\rm A}}^{-1}$ (equivalent to 1-h exposure on a 4-m telescope), all three hyperplanes outperform the FP as distance indicators. Being an empirical spectral index, $I_\mathrm{age}$ avoids the model-dependent uncertainties and bias underlying age and mass-to-light ratio measurements, yet yields a 10 per cent reduction of the median distance uncertainty compared to the FP. We also find that, as a by-product, the $I_\mathrm{age}$ hyperplane removes most of the reported environment bias of the FP. After accounting for the different SNR, these conclusions also apply to a 50 times larger sample from SDSS-III (Sloan Digital Sky Survey). However, in this case, only $\mathrm{ age}$ removes the environment bias.

D’Eugenio, Francesco (ORCID:0000000323888172)↗

Course #2430: Hearing Conservation [Slides]

Occupational hearing loss is one of the most common work-related illnesses in the United States (US). According to OSHA, 22 million US workers are exposed to hazardous noise levels at work, and 25% of these workers will develop permanent hearing loss. Hearing loss from noise is slow and painless, and you can have a disability before you notice it. This course presents the hazards associated with workplace noise, the purpose and elements of the Los Alamos National Laboratory (LANL) Hearing Conservation Program (HCP), and controls that are available to reduce your exposure to hazardous levels of noise.

59 BASIC BIOLOGICAL SCIENCES↗

CareWELL: Multimodal Region Representation Learning with Spatial Contexts for Urban Health

Rapid urbanization affects living environments by intensifying exposure to air pollution, heat, noise, and urban dynamics, which together contribute to uneven health outcomes across neighborhoods. For instance, cardiovascular, respiratory, and mental health conditions are each influenced by distinct exposures such as air pollution, extreme temperatures, or limited access to green space. These heterogeneous patterns require understanding the characteristics of geographic regions in order to explain why urban health risks vary across urban areas. Recent work in self-supervised region representation learning provides a promising way to model such characteristics from multimodal geospatial data. However, existing methods face two major limitations: (i) they often depend on non-public datasets, limiting reproducibility and applicability, and (ii) their generic pretraining objectives overlook health-relevant determinants, including temporal variability in environmental exposures and inequalities in social conditions. To address these gaps, we propose Context-Aware Region rEpresentation with Weather, Environment, and Location Learning (CareWELL). CareWELL leverages large language models to encode seasonal variability in weather, employs contrastive learning to align geo-coordinate and weather representations, and introduces a context-aware objective that integrates socio-demographic factors while preserving spatial correlations. We evaluate CareWELL by predicting six urban health outcomes in Manhattan, New York City, and demonstrate that CareWELL consistently outperforms state-of-the-art baselines as well as a traditional spatial computing method. These results suggest the importance of context-aware pretraining objectives for learning health-relevant region representations.

Namgung, Min [ORNL]↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESI DR1 Ly α 1D power spectrum: the Fast Fourier Transform estimator measurement

Here, we present the one-dimensional Lyman-α forest power spectrum measurement derived from the data release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI). The measurement of the Lyman-α forest power spectrum along the line of sight from high-redshift quasar spectra provides information on the shape of the linear matter power spectrum, neutrino masses, and the properties of dark matter. In this work, we use a Fast Fourier Transform (FFT)-based estimator, which is validated on synthetic data in a companion paper. Compared to the FFT measurement performed on the DESI early data release, we improve the noise characterization with a cross-exposure estimator and test the robustness of our measurement using various data splits. We also refine the estimation of the uncertainties and now present an estimator for the covariance matrix of the measurement. Furthermore, we compare our results to previous high-resolution and eBOSS measurements. In another companion paper, we present the same DR1 measurement using the Quadratic Maximum Likelihood Estimator (QMLE). These two measurements are consistent with each other and constitute the most precise one-dimensional power spectrum measurement to date, while being in good agreement with results from the DESI early data release.

Lyman alpha forest↗

Photometry of Outer Solar System Objects from the Dark Energy Survey. I. Photometric Methods, Light-curve Distributions, and Trans-Neptunian Binaries

We report the methods of and initial scientific inferences from the extraction of precision photometric information for the >800 trans-Neptunian objects (TNOs) discovered in the images of the Dark Energy Survey (DES). Scene-modeling photometry is used to obtain shot-noise-limited flux measures for each exposure of each TNO, with background sources subtracted. Comparison of double-source fits to the pixel data with single-source fits are used to identify and characterize two binary TNO systems. A Markov Chain Monte Carlo method samples the joint likelihood of the intrinsic colors of each source as well as the amplitude of its flux variation, given the time series of multiband flux measurements and their uncertainties. A catalog of these colors and light-curve amplitudes A is included with this publication. We show how to assign a likelihood to the distribution q(A) of light-curve amplitudes in any subpopulation. Using this method, we find decisive evidence (i.e., evidence ratio <0.01) that cold classical (CC) TNOs with absolute magnitude 6 < H$_{r}$ < 8.2 are more variable than the hot classical (HC) population of the same H$_{r}$, reinforcing theories that the former form in situ and the latter arise from a different physical population. Resonant and scattering TNOs in this H$_{r}$ range have variability consistent with either the HCs or CCs. DES TNOs with H$_{r}$ < 6 are seen to be decisively less variable than higher-H$_{r}$ members of any dynamical group, as expected. More surprising is that detached TNOs are decisively less variable than scattering TNOs, which requires them to have distinct source regions or some subsequent differential processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

Deployment and performance of a Low-Energy-Threshold Skipper-CCD inside a nuclear reactor

Charge Coupled Devices (CCD) are being used for reactor neutrino experiments and have already demonstrated their potential in constraining new physics models. The prospect of a Skipper-CCD experiment looking for standard and beyond standard model (BSM) physics in a nuclear reactor has been evaluated for different benchmark scenarios. Here, we report the first installation of a 2-g Skipper-CCD inside the containment building of a 2 GW th nuclear power plant and analyze its performance throughout its first 18 months of operation. The sensor was successfully deployed at Atucha II, in Argentina, 12 meters away from the center of the reactor core. We discuss the challenges involved in the commissioning of the detector and present data acquired during reactor ON and reactor OFF periods, with the sensor functioning with a sub-electron readout noise of 0.17 e - . Based on an exposure of 56.8 g day reactor ON and two reactor OFF data sets with a total exposure of 118.1 g day we characterize the system and evaluate the sensitivity to CEvNS. We achieved a background rate of 33 kdru and a low threshold of 45 eV ee . The ongoing efforts to improve sensitivities to CEvNS and BSM interaction are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)↗

Sequence2Self: Self-supervised image sequence denoising of pixel-level spray breakup morphology

Optical imaging of fast and transient phenomena such as the turbulent breakup of liquid sprays exhibit low signal-to-noise ratios due to the limited illumination intensity relative to the short exposure time. Image denoising is required to facilitate physical studies over these data but is challenging due to the absence of clean ground-truths and the stringency of the denoising task (e.g., strong and complex noise, limited resolution, preserving physical fidelity), preventing supervised and existing un-/self-supervised deep learning methods. To this end, Sequence2Self (Seq2S) is proposed, an extension of Self2Self (S2S) to image sequences that leverages both the signal’s spatial and temporal correlation. Seq2S is demonstrated on time-resolved x-ray phase contrast imaging of liquid jet fuel sprays in a gas turbine combustor, which possesses all of challenges detailed above. Experiments are conducted across four fuels with different breakup morphology using various state-of-the-art methods. Overall, many of the methods failed and Seq2S was most successful: (1) Accurate spray structures were reconstructed with consistent evolution across frames void of artifacts. (2) The performance was robust, invariant to the hyperparameter choice. (3) Computational time is short and can be made eligible for real-time denoising. In particular, the images denoised by Seq2S showed spray droplet diameter distributions with near-zero Kullback–Leibler divergence (0.01 ± 0.01) to a cleaner reference, whereas the second best method yielded 0.06 ± 0.03. In conclusion, this suggests that Seq2S can be reliably used prior to subsequent quantitative spray analyses as it retains (if not, improves) the statistical physical properties of the data.

97 MATHEMATICS AND COMPUTING↗

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29–1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESI DR1 Lyα 1D power spectrum: the optimal estimator measurement

The one-dimensional power spectrum P 1D of Lyα forest offers rich insights into cosmological and astrophysical parameters, including constraints on the sum of neutrino masses, warm dark matter models, and the thermal state of the intergalactic medium. We present the measurement of P 1D using the optimal quadratic maximum likelihood estimator applied to over 300,000 Lyα quasars from Data Release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI) survey. This sample represents the largest to date for P 1D measurements and is larger than the Extended Baryon Oscillation Spectroscopic Survey (eBOSS) by a factor of 1.7. We conduct a meticulous investigation of instrumental and analysis systematics and quantify their impact on P 1D . This includes the development of a cross-exposure estimator that eliminates the need to model the pipeline noise and has strong potential for future P 1D measurements. We also present new insights into metal contamination through the 1D correlation function. Using a fitting function we measure the evolution of the Lyα forest bias with high precision: b F (z) = (-0.218 ± 0.002) × ((1 + z)/4) 2.96±0.06 . In a companion validation paper, we substantially extend our previous suite of CCD image simulations to quantify the pipeline's exquisite performance accurately. In another companion paper, we present DR1 P 1D measurements using the Fast Fourier Transform (FFT) approach to power spectrum estimation. These two measurements produce a forest bias parameter that differs by 2.2 sigma. However, our model is simplistic, so this disagreement will be investigated in future work.

Lyman alpha forest↗

On-line Measurement of Hydrogen Gas using Raman Spectroscopy for Process Gas Systems

Advanced reprocessing schemes such as the Zircex process are important for continued development of the nuclear fuel cycle. The hydrochlorination reaction of the Zircex process flow sheet for metallic fuels has a known off-gas stream of H 2 (g) and HCl. The flow sheet can be simplified through HCl recycling, which requires detection and quantification of any residual H 2 (g) for safety and purity. In this work, commercially available Raman spectroscopy was applied for low-level, on-line detection of H 2 (g) in process gas streams, and parameters were adjusted to optimize the H 2 (g) Raman signal. Increasing the number of scans and exposure time in the spectrometer increased the signal-to-noise ratio of the H 2 (g) Raman signal, while the gas flow rate was optimized at 2.3 L/min. The limit of detection for H 2 (g) was estimated to be 2,100 ppm H 2 (g) in an N 2 (g) background. This scoping study for the application of Raman spectroscopy for on-line measurements of H 2 (g) shows that H 2 (g) can be detected at low levels (approximately 5% of the lower explosive limit (LEL)) in flowing gas streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗