Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Tomographic Imaging Of Low-Density Inclusions

Computed neutron tomography reveals structure of volume containing material of lesser density surrounded by material of greater density. Technique used, for example, to examine and measure flaws or other inclusions containing equally dense or less-dense material hidden in complicated structure made of denser material.

Roy, Jagatjit↗

Three-Dimensional Reconstruction of Defects and Structures in Additively Manufactured Parts with Automated Serial Sectioning

Metal additive manufacturing (AM) processes have been demonstrated to be effective at reducing costs and lead times associated with complex components for space flight applications. Laser powderbed fusion (L-PBF) is a commonly used AM technology due to the ability to produce complex parts with fine feature resolution in a wide variety of alloys and applications. L-PBF, like many other manufacturing processes, can produce minor flaws in parts when in nominal operation as well as process-escape defects when process abnormalities occur. The effects of the flaws and methods of detecting the flaws are a subject of interest to understand the difficulties in detecting these flaws with current technology and how much risk the flaws or defects pose to potential flight parts. Using a RoboMet.3D automated serial sectioning system, seeded defects as well as minor process flaws can be imaged and reconstructed in three dimensions to compare to non-destructive evaluation (NDE) techniques, such as x-ray computed tomography (CT), neutron CT, and in-situ monitoring. The RoboMet automates the metallography process by automatically grinding, polishing, and imaging samples in a single system and providing the control data for NDE comparisons to know the real size of defects built into coupons. These comparisons provide an understanding behind the technological limitations of the NDE techniques for different alloys. The same serial sectioning methods have also been utilized to characterize the surfaces of parts to reconstruct the surfaces and take measurements of internal features not easily examined with non-destructive methods. Using the RoboMet, fine lattice structures built with L-PBF have been characterized to determine the actual thicknesses of struts and density of the lattice structures. These structures have been used as finer build supports for the L-PBF process, designs for fine catalysts, and other design considerations for small components. The RoboMet data helps to inform the modeling and design efforts around these fine components.

additive manufacturing↗

Assessment of metabolic bone diseases by quantitative computed tomography

Advances in the radiologic sciences have permitted the development of numerous noninvasive techniques for measuring the mineral content of bone, with varying degrees of precision, accuracy, and sensitivity. The techniques of standard radiography, radiogrammetry, photodensitometry, Compton scattering, neutron activation analysis, single and dual photon absorptiometry, and quantitative computed tomography (QCT) are described and reviewed in depth. Results from previous cross-sectional and longitudinal QCT investigations are given. They then describe a current investigation in which they studied 269 subjects, including 173 normal women, 34 patients with hyperparathyroidism, 24 patients with steroid-induced osteoporosis, and 38 men with idiopathic osteoporosis. Spinal quantitative computed tomography, radiogrammetry, and single photon absorptiometry were performed, and a spinal fracture index was calculated on all patients. The authors found a disproportionate loss of spinal trabecular mineral compared to appendicular mineral in the men with idiopathic osteoporosis and the patients with steroid-induced osteoporosis. They observed roughly equivalent mineral loss in both the appendicular and axial regions in the hyperparathyroid patients. The appendicular cortical measurements correlated moderately well with each other but less well with spinal trabecular QCT. The spinal fracture index correlated well with QCT and less well with the appendicular measurements. Knowledge of appendicular cortical mineral status is important in its own right but is not a valid predictor of axial trabecular mineral status, which may be disproportionately decreased in certain diseases. Quantitative CT provides a reliable means of assessing the latter region of the skeleton, correlates well with the spinal fracture index (a semiquantitative measurement of end-organ failure), and offers the clinician a sensitive means of following the effects of therapy.

Minerals/analysis↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Kronos: A Multiwavelength Observatory for Mapping Accretion-Driven Sources

Kronos is a multiwavelength observatory proposed as a NASA Medium Explorer. Kronos is designed to make use of the natural variability of accreting sources to create microarcsecond-resolution maps of the environments of supermassive black holes in active galaxies and stella-size black holes in binary systems and to characterize accretion processes in Galactic compact binaries. Kronos will obtain broad energy range spectroscopic data with co-aligned X-ray, ultraviolet, and optical spectrometers. The high-Earth orbit of Kronos enables well-sampled, high time-resolution observations, critical for the innovative and sophisticated methods that are used to understand the accretion flows, mass outflows, jets, and other phenomena found in accreting sources. By utilizing reverberation mapping analysis techniques, Kronos produces advanced high-resolution maps of unprecedented resolution of the extreme environment in the inner cores of active galaxies. Similarly, Doppler tomography and eclipse mapping techniques characterize and map Galactic binary systems, revealing the details of the physics of accretion processes in black hole, neutron star, and white dwarf binary systems. The Kronos instrument complement, sensitivity, and orbital environment make it suitable to aggressively address time variable phenomena in a wide range of astronomical objects from nearby flare stars to distant galaxies.

Peterson, Bradley M.↗

Kronos: A Satellite for Astrotomography

Kronos, a Medium Explorer concept, is designed to initiate a new era in astrophysics, fully opening the domain of time by enabling extended simultaneous multiwavelength (X-ray, UV, and optical) spectroscopic monitoring of variable accretion-driven sources. The primary design goal of the mission is to obtain high-fidelity velocity-delay maps of the broad-line region in active galactic nuclei (AGNs) and thus determine the geometry and structure of AGNs on microarcsecond scales. Doppler tomography and eclipse mapping techniques will be used to characterize and map Galactic binary systems, revealing the details of the physics of accretion processes in black hole, neutron star, and white dwarf binary systems. The high-Earth orbit of Kronos enables well-sampled, high time-resolution observations, critical for the innovative and sophisticated methods that are used to understand the accretion flows, mass outflows, jets, and other phenomena found in accreting sources.

Peterson, B. M.↗

Modeling the Precession of the Warped Inner Accretion Disk in the Pulsars LMC X-4 and SMC X-1 with NuSTAR and XMM-Newton

We present a broad-band X-ray study of the effect of superorbital periods on X-ray spectra and pulse profiles in the neutron star X-ray binaries LMC X-4 and SMC X-1. These two sources display periodic or quasi-periodic variations in luminosity on the order of tens of days which are known to be superorbital, and are attributed to warped, precessing accretion disks. Using joint NuSTAR and XMM-Newton observations that span a complete superorbital cycle, we examine the broad-band spectra of these sources and find the shape to be well described by an absorbed power law with a soft blackbody component. Changes in spectral shape and pulse profile shape are periodic with superorbital period, as expected from a precessing disk. We perform X-ray tomography using the changes in pulse profiles to model the geometry and kinematics of the inner accretion disk. Our simple beam and inner disk geometric model indicates that the long term changes in soft pulse shape and phase are consistent with reprocessed emission from a precessing inner disk.

Brumback, McKinley C.↗