Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-Transmission Neutron Optical Devices Utilizing Micro-Machined Structures

Neutrons are a powerful probe in material science with unique penetrating abilities. A major challenge stems from the fact that neutron optical devices are limited to refractive indices on the order of n≈1±10−5. By exploiting advances in precision manufacturing, we designed and constructed micro-meter period triangular grating with a high-aspect ratio of 14.3. The manufacturing quality is demonstrated with white-light interferometric data and microscope imaging. Neutron-scattering experiment results are presented, showing agreement with refraction modelling. The capabilities of neutron Fresnel prisms and lenses based on this design are contrasted with existing neutron focusing techniques, and the path separation of a prism-based neutron interferometer is estimated.

Kapahi, Connor (ORCID:0000000160516859)↗

A Polarization Tensor for Neutron Optics

A rank 2 dimension 3 tensor formulation for polarized neutron transport in a magnetic field is derived. Using this formulation, the rotating magnetic field problem is revisited to produce a single 3 × 3 vector-transformation matrix that describes the polarization transport. That result is then used to fashion a new strategy for a numerical approximation of polarization transport in an arbitrary magnetic field using time-dependent perturbation theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Second Target Station Project (STS) Steerable Optic Design & Testing Report

Multiple neutron scattering instrument concepts for the Spallation Neutron Source's Second Target Station (STS) incorporate advanced neutron optic designs which incorporate discrete mirrors rather than continuous neutron guides that were the standard for instruments in the First Target Station. These mirrors can be a few to several meters in length and must be stably supported and aligned as a single optic. In addition, due to the length of the STS instruments and the small size of the STS neutron beams, installation and alignment at the micron level of precision will be required, which is beyond the ability of today's survey & alignment technology. Thus, a means of remotely adjusting these mirrors with single digit micron resolution is needed. A Steerable Optic System was designed to provide the precision and resolution required to support and manipulate these large, heavy optics under beamline shielding. A mockup was developed to demonstrate and validate this system for use in neutron optic applications, and this document describes the design and testing results of that mockup.

43 PARTICLE ACCELERATORS↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for Continuously Resolving Spectral Shifts in Distributed Optical Fiber Sensors Irradiated to Extreme Neutron Fluence

Optical frequency domain reflectometry (OFDR) is a technique for interrogating distributed optical fiber sensors (DOFS) and involves correlating changes in the Rayleigh backscatter fingerprint for a fiber under test (FUT) with a reference measurement. Recently, under the WIRE-21 experiment sponsored by Nuclear Science User Facilities (NSUF) and performed at the High-Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL), silica optical fibers were irradiated to a fast neutron fluence of 1x10^21 n/cm^2/s at temperatures from 200--400 C. As in the cases of high-temperature and high-strain conditions, such high levels of neutron bombardment result in a highly dynamic RBS that evades analysis with conventional methods. This work describes the further development and application of graphical signal processing techniques applied to OFDR-based distributed optical fiber sensors specifically deployed in in-pile applications. While the signal processing techniques developed in this work are applied to DOFS in nuclear environments, they provide a general framework for the analysis of OFDR measurements and a tangible method to yield higher quality data, without imposing additional hardware requirements.

Sweeney, Dan↗

Generation of Neutron Airy Beams

The Airy wave packet is a solution to the potential-free Schrödinger equation that exhibits remarkable properties such as self-acceleration, nondiffraction, and self-healing. Although Airy beams are now routinely realized with electromagnetic waves and electrons, the implementation with neutrons has remained elusive due to small transverse coherence lengths, low fluence rates, and the absence of neutron lenses. In this Letter, we overcome these challenges through a holographic approach and present the first experimental demonstration of neutron Airy beams. The presented techniques pave the way for fundamental physics studies with Airy beams of nonelementary particles, the development of novel neutron optics components, and the realization of neutron Airy-vortex beams. Published by the American Physical Society 2025

Sarenac, Dusan (ORCID:0000000185753367)↗

The HIBEAM instrument at the European spallation source

The European spallation source (ESS) will be the world’s brightest neutron source and will open a new intensity frontier in particle physics. The HIBEAM collaboration aims to exploit the unique potential of the ESS with a dedicated ESS instrument for particle physics which offers world-leading capability in a number of areas. The HIBEAM program includes the first search in thirty years for free neutrons converting to antineutrons and searches for sterile neutrons, ultralight axion dark matter and nonzero neutron electric charge. This paper outlines the capabilities, design, infrastructure, and scientific potential of the HIBEAM program, including its dedicated beamline, neutron optical system, magnetic shielding and control, and detectors for neutrons and antineutrons. Additionally, we discuss the long-term scientific exploitation of HIBEAM, which may include measurements of the neutron electric dipole moment and precision studies of neutron decays.

47 OTHER INSTRUMENTATION↗

Second Target Station (STS) Project: PIONEER Technical Report

PIONEER is a time-of-flight single-crystal neutron diffractometer at the Second Target Station (STS), aiming at providing the world-leading capability to measure tiny crystals (~0.001 mm 3 , i.e., X-ray diffraction size), ultra-thin epitaxial films (~10 nm thicknesses), and weak structural transitions and complex magnetism. The instrument will take advantage of STS source characteristics and utilize advancements in neutron optics to largely reduce the sample-volume requirement for single-crystal neutron diffraction. PIONEER will have a high-flux mode with multiple beam size options to improve the signal-to-background ratio in various sample environments. It will also provide a high Q-resolution mode by limiting beam divergence to study periodically modulated structures with characteristic lengths no less than 100 Å. Furthermore, it supports half-polarized neutron diffraction for investigating complex magnetism and local susceptibility. This report first overviews the proposed science case and the derived requirement. And then, the chosen technical solutions and expected performance will be described.

36 MATERIALS SCIENCE↗

Selected advances in small-angle scattering and applications they serve in manufacturing, energy and climate change

Innovations in small-angle X-ray and neutron scattering (SAXS and SANS) at major X-ray and neutron facilities offer new characterization tools for researching materials phenomena relevant to advanced applications. For SAXS, the new generation of diffraction-limited storage rings, incorporating multi-bend achromat concepts, dramatically decrease electron beam emittance and significantly increase X-ray brilliance over previous third-generation sources. This results in intense X-ray incident beams that are more compact in the horizontal plane, allowing significantly improved spatial resolution, better time resolution, and a new era for coherent-beam SAXS methods such as X-ray photon correlation spectroscopy. Elsewhere, X-ray free-electron laser sources provide extremely bright, fully coherent, X-ray pulses of <100 fs and can support SAXS studies of material processes where entire SAXS data sets are collected in a single pulse train. Meanwhile, SANS at both steady-state reactor and pulsed spallation neutron sources has significantly evolved. Developments in neutron optics and multiple detector carriages now enable data collection in a few minutes for materials characterization over nanometre-to-micrometre scale ranges, opening up real-time studies of multi-scale materials phenomena. SANS at pulsed neutron sources is becoming more integrated with neutron diffraction methods for simultaneous structure characterization of complex materials. In this paper, selected developments are highlighted and some recent state-of-the-art studies discussed, relevant to hard matter applications in advanced manufacturing, energy and climate change.

36 MATERIALS SCIENCE↗

CENTAUR - The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source

CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a high-resolution chopper will enable detailed structural and dynamical investigations of magnetic and quantum materials. CENTAUR’s excellent resolution makes it ideal for low-angle diffraction studies of highly ordered large-scale structures, such as skyrmions, shear-induced ordering in colloids, and biomembranes. Additionally, the spectroscopic mode of this instrument extends to lower momentum transfers than are currently possible with existing spectrometers, thereby providing a unique capability for inelastic SANS studies.

47 OTHER INSTRUMENTATION↗

Interfaces in all solid state Li-metal batteries: A review on instabilities, stabilization strategies, and scalability

With technological advancements in electrochemical energy storage systems increasing at a spectacular rate, batteries equipped with a lithium anode hold the key towards unlocking high energy densities. While lithium-ion batteries with layered anodes (e.g. graphite) and liquid organic electrolytes have been ubiquitous in portable electronics, electric vehicles, and grid applications, all solid-state batteries that use the combination of a lithium anode and a solid-state electrolyte (SSE) will further advance the present technology. The underlying challenge that limits the successful development of all solid-state batteries (ASSBs) is dictated largely by the highly reactive interfaces at the anode/SSE and the cathode/SSE interface. In this comprehensive review, we present an overview of the following: (i) characterization of the electrode/SSE interface via multimodal characterization, which include X-ray-, electron-, neutron-, optical-, and computation-based methods: (ii) parasitic reactions that occur from chemical, mechanical or electrochemical instabilities and interfacial engineering strategies for improving the stability of these interfaces classified by the class of inorganic SSEs (sulfide-, NASICON-, and garnet-type SSEs); (iii) laboratory-to-industry scale processing perspectives of SSEs; (iv) scalability and manufacturing aspects of current interfacial strategies; and (v) the prospects of all ASSBs within the context of extreme fast charging capability. Here, this review seeks to highlight key efforts in the field of ASSBs, by focusing particularly on stabilizing the electrode/SSE interfaces, which will help to bridge fundamental studies to technological relevance.

25 ENERGY STORAGE↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

M-STAR: Magnetism second target advanced reflectometer at the Spallation Neutron Source

M-STAR is a next generation polarized neutron reflectometer with advanced capabilities. A new focusing guide concept is optimized for samples with dimensions down to a millimeter range. A proposed hybrid pulse-skipping chopper will enable experiments at constant geometry at one incident angle in a broad range of wavevector transfer Q up to 0.3 A –1 for specular, off-specular, and GISANS measurements. M-STAR will empower nanoscience and spintronics studies routinely on small samples (~2 × 2 mm 2 ) and of atomic-scale thickness using versatile experimental conditions of magnetic and/or electric fields, light, and temperature applied in situ to novel complex device-like nanosystems with multiple buried interfaces. M-STAR will enable improved grazing incidence diffraction measurements, as a surface-sensitive depth-resolved probe of, e.g., the out-of-plane component of atomic magnetic moments in ferromagnetic, antiferromagnetic, and more complex structures as well as in-plane atomic-scale structures inaccessible with contemporary diffractometry and reflectometry. New horizons will be opened by the development of an option to probe near-surface dynamics with inelastic grazing incidence scattering in the time-of-flight mode. These novel options in combination with ideally matched parameters of the second target station will place M-STAR in the world’s leading position for high resolution polarized reflectometry.

47 OTHER INSTRUMENTATION↗