Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron line profile analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Data-driven analysis of neutron diffraction line profiles: application to plastically deformed Ta

Abstract Non-destructive evaluation of plastically deformed metals, particularly diffraction line profile analysis (DLPA), is valuable both to estimate dislocation densities and arrangements and to validate microstructure-aware constitutive models. To date, the interpretation of whole line diffraction profiles relies on the use of semi-analytical models such as the extended convolutional multiple whole profile (eCMWP) method. This study introduces and validates two data-driven DLPA models to extract dislocation densities from experimentally gathered whole line diffraction profiles. Using two distinct virtual diffraction models accounting for both strain and instrument induced broadening, a database of virtual diffraction whole line profiles of Ta single crystals is generated using discrete dislocation dynamics. The databases are mined to create Gaussian process regression-based surrogate models, allowing dislocation densities to be extracted from experimental profiles. The method is validated against 11 experimentally gathered whole line diffraction profiles from plastically deformed Ta polycrystals. The newly proposed model predicts dislocation densities consistent with estimates from eCMWP. Advantageously, this data driven LPA model can distinguish broadening originating from the instrument and from the dislocation content even at low dislocation densities. Finally, the data-driven model is used to explore the effect of heterogeneous dislocation densities in microstructures containing grains, which may lead to more accurate data-driven predictions of dislocation density in plastically deformed polycrystals.

36 MATERIALS SCIENCE↗

The Convolutional Multiple Whole Profile (CMWP) Fitting Method, a Global Optimization Procedure for Microstructure Determination

The analysis of line broadening in X-ray and neutron diffraction patterns using profile functions constructed on the basis of well-established physical principles and TEM observations of lattice defects has proven to be a powerful tool for characterizing microstructures in crystalline materials. These principles are applied in the convolutional multiple-whole-profile (CMWP) procedure to determine dislocation densities, crystallite size, stacking fault and twin boundary densities, and intergranular strains. The different lattice defect contributions to line broadening are separated by considering the hkl dependence of strain anisotropy, planar defect broadening and peak shifts, and the defect dependent profile shapes. The Levenberg–Marquardt (LM) peak fitting procedure can be used successfully to determine crystal defect types and densities as long as the diffraction patterns are relatively simple. However, in more complicated cases like hexagonal materials or multiple-phase patterns, using the LM procedure alone may cause uncertainties. Here, we extended the CMWP procedure by including a Monte Carlo statistical method where the LM and a Monte Carlo algorithm were combined in an alternating manner. The updated CMWP procedure eliminated uncertainties and provided global optimized parameters of the microstructure in good correlation with electron microscopy methods.

36 MATERIALS SCIENCE↗

Alloying effects on deformation induced microstructure evolution in copper

In this work, we investigated the effects of alloying elements on plastic deformation and microstructure evolution in polycrystalline copper (Cu) and Cu alloyed with 1 wt. % lead (Cu-1 %Pb). These materials were selected due to the size mismatch between Cu and Pb, with the latter forming precipitates at grain boundaries. Multi-modal characterization techniques, including neutron diffraction, electron backscatter diffraction (EBSD), and transmission electron microscopy (TEM), along with finite element simulations were employed to study the deformation behavior across multiple length scales. While both Cu and Cu-1%Pb exhibited similar macroscale response and final deformation textures, both dislocation line profile analysis and TEM revealed increased dislocation density in deformed Cu-1%Pb specimens. The presence of lead precipitates also significantly affected local plastic deformation during compression, with their influence diminishing with increasing strain. These results demonstrate the complex relationships between alloying elements, plastic deformation, microstructural evolution, and material behavior under load. The insights gained from this multi-scale and multi-technique approach contribute to the fundamental understanding of microstructural evolution in immiscible alloys and are valuable for tailoring the properties of structural materials for specific engineering applications.

36 MATERIALS SCIENCE↗

Phase stability and microstructure of neutron-irradiated substoichiometric yttrium dihydrides

The impact of the neutron-displacement damage on phase stability and microstructure of substoichiometric yttrium dihydrides (YH x , x <2) were investigated to assess their use as solid moderator in high-temperature nuclear reactors. YH x specimens were, thus, subjected to neutron irradiations in the range of 0.1–2 displacements per yttrium atom (dpa-Y) in the temperature range of 536–878°C at the Oak Ridge National Laboratory's (ORNL's) High Flux Isotope Reactor (HFIR). YH x specimens were initially prepared at stoichiometry (H/Y) ratios of 1.69 and 1.83. HFIR-irradiated specimens were characterized by variety of techniques to investigate H retention characteristics including dimensional analysis, optical microscopy, scanning electron microscopy electron back scatter diffraction (EBSD), transmission electron microscopy, thermal desorption spectroscopy (TDS), and high-energy x-ray diffraction (HE-XRD) characterizations. Overall, YH x exhibited notable structural and phase stability under short-term neutron-irradiation, except for the samples with significant silicon carbide (SiC) interaction at high doses and temperatures. Basic dimensional and mass measurements were misleading for accurate assessment of H retention, as confirmed by EBSD phase maps, XRD line profiles, and TDS signals. Thus, it was discussed that a robust H retention metric is needed to assess irradiated hydrides. Further, nanoscale cavities were observed as a result of the neutron irradiation in all samples. Although no clear impact of dose and irradiation temperature was determined, the initial H/Y ratio had an impact on the cavity number density where low H/Y specimens had high-resistance to cavity formation. The Y-vacancy cluster formation at the collision stage of the displacement cascade and their stabilization by H were considered to be the likely underlying mechanisms for the observed cavity microstructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast ion transport by sawtooth instability in the presence of ICRF-NBI synergy in JET plasmas

JET experiments have shown that the three-ion scenarios using waves in the ion cyclotron range of frequencies (ICRF) is an efficient way to build fast ion population through beam ion acceleration by radio frequency (RF) waves. Here, such a heating scheme is applied to plasmas with at least two thermal ion species. Analysis of mixed discharges with complex heating schemes requires a workflow that allows to model thermal and fast ion transport consistently. This paper is dedicated to modelling of a mixed plasma discharge with significant fraction of fast ions and contributes to development of fast ion transport models. For interpretive analysis with the TRANSP code a JET hydrogen-deuterium (HD) plasma discharge with neutral beam injection (NBI) and ICRF heating has been chosen. The task is complicated by NBI-ICRF synergy and plasma magnetohydrodynamic activity, like sawtooth crashes. D beam ions accelerated by RF waves form a high energy tail in fast ion distribution. Significant difference between the neutron rate computed by TRANSP and measured one is observed if the same diffusivity for electrons and ions is assumed. Sensitivity studies show that uncertainties in input plasma parameters and thermal ion transport models are crucial for modelling mixed plasma discharges and increased D transport is required to reach the plasma composition consistent with diagnostic measurements at the plasma edge. Fast ion redistribution by a sawtooth instability is characterised by non-resonant transport due to reconnection of magnetic field lines and resonant transport caused by resonance interaction between the instability and fast ions. With ORBIT simulations it has been shown that resonant interaction strongly affects fast ions of high energies, like beam ions accelerated by RF waves and fusion products. For the considered case, fast ion profiles simulated by ORBIT remain peaked after the sawtooth crashes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗