Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “natural ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamic metrics of natural ventilation cooling effectiveness for interactive modeling

The evaluation of natural ventilation potential for cooling indoor spaces during the early design phases is of great interest to researchers and practitioners. Among various definitions and usages for natural ventilation potential (NVP) in early design evaluation, this paper reviews and identifies the key performance indicators, and proposes two new dynamic metrics—natural ventilation cooling effectiveness (NVCE) and climate potential utilization ratio (CPUR). The metrics are dynamically responsive to various design options, in both steady and transient states, allowing consideration of thermal mass. Assisting in design development processes, the metrics quantify how well indoor spaces make use of natural ventilation’s cooling capacity. Case studies are presented to demonstrate how NVCE and CPUR enable designers to evaluate the predicted performance and how to apply the information to improve building design. Finally, the results of the design iterations showed that the relationship among various design parameters should be dynamically understood in order to evaluate the performance of natural ventilation, confirming that “the more the airflow, the greater the potential,” and “the heavier the thermal mass, the greater the energy saving” were not always true.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Window Positions for Wind-Driven Natural Ventilation Performance

This paper optimizes opening positions on building facades to maximize the natural ventilation’s potential for ventilation and cooling purposes. The paper demonstrates how to apply computational fluid dynamics (CFD) simulation results to architectural design processes, and how the CFD-driven decisions impact ventilation and cooling: (1) background: A CFD helps predict the natural ventilation’s potential, the integration of CFD results into design decision-making has not been actively practiced; (2) methods: Pressure data on building facades were obtained from CFD simulations and mapped into the 3D modeling environment, which were then used to identify optimal positions of two openings of a zone. The effect of the selected opening positions was validated with building energy simulations; (3) results: The cross-comparison study of different window positions based on different geographical locations quantified the impact on natural ventilation effectiveness; and (4) conclusions: The optimized window position was shown to be effective, and some optimal solutions contradicted the typical cross-ventilation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of window scheduler algorithm exploiting natural ventilation and thermal mass for building energy simulation and smart home controls

Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.

42 ENGINEERING↗

Effects of Different Types of Entrances on Natural Ventilation in a Subway Station

In this study, the natural ventilation of a horizontal entrance of a typical subway station is investigated based on numerical simulations and experiments. In addition, a renormalization group k-e model (RNG k-e model) is applied to compute both the internal and external airflow patterns. Computational fluid dynamics (CFD) simulations are validated based on the experimental results. Furthermore, a multiple variable regression model is employed to study how the different parameters affect the internal airflow rates of the subway station statistically, according to the experimental results. For this typical model, the parameter importance can be ranked as follows: (1) outdoor wind speed; (2) flow resistance of the subway station; (3) height of the wind catcher; and (4) length of the wind catcher. To understand the detailed pressure distribution of the horizontal entrance of the subway station with and without the wind catcher, 3D numerical simulations are conducted for different scenarios. We attempt to alter the size of the wind catcher (including the length and height) to study the characteristics of the pressure on the horizontal entrance of the subway station under outdoor wind-driven conditions. The pressure distributions for the entrance for different scenarios are compared and analyzed. Finally, the interactions between the internal and external flows are investigated by changing the resistance of the subway station. When the internal flow resistance is changed, the pressure coefficient (Cp) of the entrance is different as well. Hence, the Cp is not only affected by the outdoor environment, but is also influenced by the internal airflows.

CFD↗

Technology assessment to reduce aerosol transmission risk in naturally ventilated K12 classrooms (CRADA Final Report)

LBNL provided technical assistance to Oakland Unified School District (OUSD) through this project in their selection of technologies to support in-person instruction. OUSD considered different technologies to mitigate the aerosol transmission risks of COVID-19: a) Upgrade to higher efficiency air filters in buildings that are served by heating, ventilation, and air conditioning (HVAC) systems. b) Install portable air cleaners with HEPA (high efficiency particulate air) filters. c) Install ultraviolet germicidal irradiation (UVGI) systems. d) Install bipolar ionization air cleaning systems. LBNL met with OUSD facilities staff to discuss the pros and cons of options a) and c), and cited the lack of proven data on efficacy and discouraged option d). LBNL provided practical guidance on how to select portable air cleaners for classrooms. LBNL met with the boarder school communities to explain OUSD approach to ventilation and filtration, and produced FAQs to answer their questions about the science behind the selected approaches. In addition, LBNL helped OUSD facilities staff to acquire five indoor air quality (IAQ) monitors (AirVisual Pro by IQAir) for measuring carbon dioxide (CO2) and particulate matter (PM) concentrations. These monitors were installed in an elementary school in West Oakland.

60 APPLIED LIFE SCIENCES↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California

This work presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ), formaldehyde and carbon dioxide (CO 2 ) and time-integrated formaldehyde, NO 2 and nitrogen oxides (NO X ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM 2.5 , formaldehyde, NO 2 , and CO 2 were 7.7 µg/m 3 , 14.1 ppb, 18.8 ppb, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM 2.5 above the California annual outdoor standard of 12 µg/m 3 and also discrete days above the World Health Organization 24-h guideline of 25 µg/m 3 . Two apartments had weekly NO 2 above the California annual outdoor standard of 30 ppb.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing occupant archetypes within urban low-income housing: A case study in Mumbai, India

Rapid urbanization pressure and poverty have created a push for affordable housing within the global south. The design of affordable housing can have consequences on the thermal (dis)comfort and behaviour of the occupants, hence requiring an occupant-centric approach to ensure sustainability. This paper investigates occupant behaviour within the urban poor households of Mumbai, India and its impact on their thermal comfort and energy use. This study is a first-of-its-kind attempt to explore the socio-demographic characteristics and energy-related behaviour of low-income occupants within Indian context. Three occupant archetypes, Indifferent Consumers; Considerate Savers; and Conscious Conventionals, were identified from the behavioural and psychographic characteristics gathered through a transverse field survey. A two-step clustering approach was adopted for occupant segmentation that highlighted considerable diversity in occupants’ adaptation measures, energy knowledge, energy habits, and their pro-environmental behaviour within similar socio-economic group. Building energy simulation of the representative archetype behaviour estimated up to 37% variations for air-conditioned and up to 8% variation for fan-assisted naturally ventilated housing units during peak summer months. The results from this study establish the significance of occupant factors in shaping energy demand and thermal comfort within low-income housing and pave way for developing occupant-centric building design strategies to serve this marginalized population. The developed low-income occupant archetypes would be useful for architects and energy modelers to generate realistic energy use profiles and improve building performance simulation results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗