Performance and Economic Evaluation of sCO2 Bottoming Cycles for Natural Gas Combined Cycle Plants with Capture

Natural gas combined cycles (NGCCs) with carbon capture are expected to play a significant role in decarbonization of the power generation sector. NGCC plants generally use triple pressure reheat steam Rankine power cycles for the bottoming cycle. Some studies in the literature have investigated the application of recompression and cascade style supercritical CO2 (sCO2) cycles for NGCC bottoming cycle applications but these studies have focused on power plants without carbon capture. However, NGCC plants fitted with post-combustion solvent-based CO2 capture systems will require a significant amount of steam for solvent regeneration and this can have a major impact on the optimal sCO2 bottoming cycle design. This study investigates the performance and economic potential of sCO2 bottoming cycles for H-class gas turbine based NGCC plants with a post-combustion capture system. A portion of the gas turbine exhaust heat is used for generation of steam required for solvent-based capture system while the rest of the waste heat is utilized in an sCO2 bottoming cycle for power generation. Overall, the performance and LCOE of investigated sCO2 bottoming cycles is similar to that of a state-of-the-art triple pressure reheat steam Rankine cycle. As the gas turbine exhaust temperature increases (beyond 630oC), sCO2 bottoming cycles begin to show greater performance and economic benefits compared to a steam Rankine cycle.

Pidaparti, Sandeep↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗

Second generation non-aqueous solvents (gen2nas) for co 2 capture from natural gas combined cycle plants

This final technical report submitted to DOE/NETL presents all the research activities performed during the Cooperative Agreement DE-FE0032218 entitled Second Generation Non-Aqueous Solvents (GEN2NAS) for CO 2 Capture from Natural Gas Combined Cycle Plants, which spanned from April 2023 through March 2025. In this project, Research Triangle Institute (RTI) International has developed the second-generation of its non-aqueous solvent (NAS), herein referred to as GEN2NAS, to remove carbon dioxide (CO 2 ) from natural-gas combined cycle (NGCC) flue gas. The technology aims to substantially reduce the cost of CO 2 capture while minimizing the environmental impacts through lower secondary emissions and wastewater generated from the CO 2 capture plant.

01 COAL, LIGNITE, AND PEAT↗

Natural Gas Combined Cycle Carbon Capture Retrofit Database

This tool provides high-level analysis on the incremental costs for retrofitting natural gas combined cycle plants with carbon dioxide capture and/or compression systems. Options are available to include costs of other technological improvements that would be required to comply with various environmental regulations when installing carbon capture technology. This model is based on the NETL report "Cost and Performance of Retrofitting NGCC Units for Carbon Capture" (2023).

03 NATURAL GAS↗

Methodology for Estimating Performance and Cost of Natural Gas Combined Cycle Plants with Carbon Capture

This document describes a methodology that allows developers and evaluators to assess the status of developmental, natural gas combined cycle (NGCC) power plant post-combustion carbon dioxide (CO 2 ) separation technologies with respect to NETL performance and cost metrics. Developmental CO 2 separation technologies that might apply for NGCC post-combustion power generation can be placed into several categories, including, but not limited to membranes, solvents, sorbents, adsorbents, and phase-change technologies. The intent of this product is to provide a consistent methodology for high-level comparison of in-development technology to a standardized baseline.

20 FOSSIL-FUELED POWER PLANTS↗

Transformational Nano-confined Ionic Liquid Membrane for Greater than or Equal to 97 Percent Carbon Dioxide Capture from Natural Gas Combined Cycle Flue Gas

A transformational process based on nano-confined ionic liquid (NCIL) membranes was developed for capturing ≥97% CO 2 from natural gas combined cycle (NCCC) flue gas. The NCIL membranes were prepared by loading amino acid ionic liquid into a framework composed of single-walled carbon nanotube mesh filled with graphene oxide quantum dots. The membranes exhibited CO 2 permeance as high as 2,000 GPU with a CO 2 /N2 selectivity of 2,300 for a typical NGCC flue gas composition. When H 2 O vapor sweep was applied in the permeate side, 96.6% CO2 dry-basis purity and 97.6% CO 2 capture rate were achieved for a simulated NGCC flue gas with single stage. In the process design, a highly H 2 O-selective membrane would be needed to recover majority of the H 2 O vapor, and the recovered H 2 O vapor could be recycled to the permeate side of the NCIL membrane. Sulfonated poly(ether ether ketone) membranes were successfully developed for this purpose. These membranes exhibited H 2 O permeance great than 11,000 GPU and H 2 O/CO 2 selectivity greater than 1,000 at 70ºC for a feed mixture consisting of 14.5 vol% H2O and balanced CO 2 . A standalone membrane model using MATLAB platform was developed for process simulation. The model was validated with experimental data. Techno-economic analysis based on the testing data collected during the current program suggests this transformational membrane process can achieve 97% CO 2 capture efficiency with a cost of $47.8/tonne of CO 2 , which is a 21% reduction versus DOE’s reference case B31B.97.

03 NATURAL GAS↗

High CO2 Capture Rate Cost and Performance for F- and H-Class Natural Gas Combined Cycles (NGCC)

The National Energy Technology Laboratory (NETL) is updating its study titled “Cost and Performance Baselines for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity.” Revision 4 was published in 2019. Pulverized coal (PC) and natural gas combined cycle (NGCC) cases with carbon capture in that study capture carbon dioxide (CO2) at 90% efficiency. Field-testing of post-combustion CO2 capture technology as well as vendor and industry feedback on projects currently in the planning stages (including FEED projects sponsored by DOE) indicate that capture rates as high as 95% are feasible for both coal- and natural gas-fueled electricity generating units. Technology suppliers (as reflected in vendor-supplied information provided to DOE for this study that included cost and performance estimates for both NGCC (97%) and PC (99%) study cases) as well as subject matter experts acknowledge and support that solvent-based post-combustion CO2 capture technologies are capable of achieving CO2 removal rates beyond 95% on low-purity streams representative of fossil-fueled combustion; however, the relatively limited experience with design and operation of capture systems that can routinely, reliably, and economically achieve very high removal rates (e.g., 97% for NGCC flue gas) requires further study. This presentation will address performance and cost estimates for 90%, 95%, and 97% capture for F- and H-class NGCC plants. This presentation was given at the 2022 Pittsburgh Coal Conference.

Fout, Timothy↗

Natural Gas Combined Cycle (NGCC) Power Plants with Carbon Capture and Exhaust Gas Recycle (EGR)

The purpose of this study is to determine the cost and performance of natural gas combined cycle (NGCC) power plants using state-of-the-art gas turbines with post combustion carbon capture and recycle streams designed to increase the CO 2 concentration in the inlet to the capture system. Increasing the inlet CO 2 concentration by exhaust gas recycle (EGR) is expected to improve the efficiency of the capture system and reduce its costs. Primary results indicate that adding EGR to NGCC plants with CO 2 capture results in minimal improvement to the cost of electricity. The addition of 50 percent EGR in NGCC plants with CO 2 capture reduces the LCOE by 2 percent over the LCOE of the same design without EGR as reference. Including the EGR ductwork and cooler in a greenfield plant design could still be prudent since there is some cost advantage to EGR and it would allow more flexibility for taking advantage of future improvements in the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Fluor Solvent Evaluation and Testing New Scope: Techno-economic Assessment of EEMPA Solvent for CO 2 Separations from Natural Gas Combined Cycle Power Plant

In this project, a techno-economic analysis (TEA) and sensitivity studies were conducted to assess the PNNL’s leading water-lean CO 2 capture solvent, EEMPA, for capture CO 2 from a natural gas combined cycle (NGCC) power plant at different levels of capture rate. Process models for the NGCC power plant, integrated with EEMPA carbon capture processes, were developed in Aspen Plus V14 using the most up-to-date property package for EEMPA-H 2 O-CO 2 system. The TEA evaluated EEMPA carbon capture process at normal capture rates (90%, 95% and 97%) against Case B32B (Cansolv) described in NETL Rev4a baseline report, and at higher capture rates aimed at achieving zero or negative emissions from the power plant (400 ppmv, 200 ppmv, and 100 ppmv CO 2 in exhaust gas), compared to typical Direct Air Capture (DAC) technologies. A manuscript was drafted for peer-reviewed publication. The results suggested that the carbon capture cost reaches a minimum of $\$$53.7/tonne CO 2 at 90% capture rate. Compared to Cansolv, one of the industrial benchmarks, EEMPA demonstrates 2-4% cost savings at capture rates up to 95%, but minimal savings at higher capture rate. The water lean-solvent system proves economically attractive for achieving moderate negative emissions (about 200 ppmv CO 2 in exhaust gas, and equivalent to 50% CO 2 removal from air) for NGCC flue gas, with marginal capture costs comparable to direct air capture (DAC) technologies. A sensitivity analysis results reveal that its economic advantage, unaffected by EEMPA price due to low solvent loss and degradation rate. However, the marginal carbon capture cost exceeds $\$$1,000/tonne CO 2 when transitioning from moderate to extreme negative emissions (100 ppmv CO 2 in exhaust gas), suggesting that water-lean solvents may not be economically competitive with other DAC technologies for removing more than 75% CO 2 from air. In addition, initial connection was established with Technology Center Mongstad (TCM) for a potential pilot testing proposal. However, detailed modeling and proposal preparation was not conducted due to the delay of non-disclosure agreement.

20 FOSSIL-FUELED POWER PLANTS↗

Natural Gas Combined Cycle Power Plants with Carbon Capture and Exhaust Gas Recycle

This is a presentation given at the 3rd International Conference on Energy and Environment. The presentation highlights analysis work conducted by NETL to assess the cost and performance for natural gas combined cycle (NGCC) power plants that incorporate solvent-based post combustion carbon dioxide (CO2) capture and exhaust gas recycle (EGR). Increasing the inlet CO2 concentration by EGR is expected to improve the efficiency of the capture system and reduce its cost, however the analysis results show that the cost improvement is minimal as is the cost of capture reduction.

Hackett, Gregory↗

CERF Visualization: Projected locations of new natural gas combined cycle power plants (with recirculating cooling) in Wyoming, USA (2020-2050)

Visualization of CERF outputs for years 2030-2050 in 5-year time steps for a region in Wyoming, USA. This visualization was built using a custom CesiumJS application. The region of interest was zoomed into and then the app shows the layered application of natural gas combined cycle power plants (with recirculating cooling) suitability criteria, show the siting for each year in planform, simulates the selection of a site using Net Locational Cost, and then zooms into to show a single functional gas plant and simulates its connection to the grid.

CERF↗

Deployment Feasibility Futures Analysis of Natural Gas Combined Cycle with Carbon Capture in Five U.S. Regions

A broad suite of technologies will be required to enable the United States to meet the current goal of a zero-carbon power sector by 2035, while continuing to provide the U.S. consumer with reliable, secure, stable, and affordable electricity. This study was conducted to evaluate the competitiveness of a natural gas combined cycle (NGCC) with carbon capture and storage (CCS) in five independent system operating areas, the PJM interconnection (PJM) regional transmission organization, Midcontinent Independent System Operator (MISO), Western Electricity Coordinating Council’s (WECC) Northwest Power Pool (NWPP) region, the Electric Reliability Council of Texas (ERCOT) and the SERC Reliability Corporation (SERC) in the 2030 to 2035 time horizon. The modeling and simulation efforts focused on determining the dispatch characteristics and the economic feasibility of constructing an NGCC plant with CCS in each of those regions. The analysis indicates that a NGCC system with CCS can be economically viable in the ERCOT and PJM regions. Additional revenue stream and/or capacity payments are required in MISO, NWPP, and SERC to enable successful commercial deployment of a NGCC with CCS.

Pickenpaugh, Gavin↗

Net Present Value Optimization of a Natural Gas Combined Cycle Plant with CO 2 Capture using a Water-Lean Solvent Considering Transient Electricity Price for Multiple Regions

Global CO 2 emissions are increasing at about a 1.5% rate per year. Fossil fuel-based plants are one of the main contributors to this rise. In the power generation industry, fossil fuel plants are dominant, and many plants are under development. In this study, a natural gas combined cycle (NGCC) power plant with postcombustion capture using a leading water-lean solvent is considered. For optimal design and operating schedule, large-scale dynamic optimization is undertaken for net present value (NPV) optimization. The first principle dynamic model of NGCC is developed, including a model of the highly efficient H-class gas turbines. For computational tractability of the dynamic optimization problem, a reduced-order model is developed by using the Hankel singular value decomposition. A waterlean solvent, N-(2-ethoxyethyl)-3-morpholinopropan-1-amine, is used for carbon capture. A model of the capture system is developed in Aspen Plus, which is used to develop a reduced-order model by using ALAMO, a machine learning software. In addition, a reduced model of the CO 2 compression system with a dehydration unit is also considered. The integrated system is used for NPV optimization by using the Python-based PYOMO platform. The PCC process is analyzed for three configurations-conventional packed bed, rotating packed bed (RPB), and a combination of RPB and direct contact cooler. The NPV optimization is performed for 14 regional markets by considering year-long clustered and continuous locational marginal price data with a 1 h interval. Optimization results show that the PCC can achieve 90% CO 2 capture with a positive NPV for six regions. Sensitivity studies conducted by using the PCC configurations indicate that the process is economically feasible for 9 regions out of 14 regional electricity markets with NPV values in the range of 33−540 $MM.

cabon capture↗

Multiobjective Dynamic Optimization for Optimal Load-Following of Natural Gas Combined Cycle Power Plants under Stress Constraints

With the increasing penetration of intermittent renewable energy sources into the electric grid, there is an associated need for conventional thermal power plants that are designed to operate at base-load conditions to cycle their load rapidly and frequently and operate under low-load conditions. Fast load-following operations lead to plant efficiency loss and the reduction of equipment life. A high-fidelity dynamic model of a natural gas combined cycle power plant, with rigorous equipment level submodels, is developed to capture the plant transient performance and the thermomechanical stress evolution at the high-pressure drum is computed to assess the drum life consumption. Stress evolution is modeled for the location of the edge at the drum/downcomer junction that experiences high circumferential stress amplitude during the fast load-following operation, leading to higher fatigue damage than locations considered under existing design standards. A dynamic optimization problem is solved for optimal load-following operation. Depending on the value of the stress constraint and the desired ramp rate, satisfying the desired stress constraint may be infeasible without relaxing the ramp rate. A multiobjective dynamic optimization problem is solved using a lexicographic approach that minimizes ramp rate relaxation and maximizes efficiency while satisfying stress constraints, avoiding spraying to saturation, and maintaining main steam and reheat steam temperature within bounds. It was observed that the optimal ramp rate can be highly nonlinear as opposed to the industry-standard linear ramp rate. Nonlinear optimal ramp-rate profiles not only help to avoid stress constraints that may be unavoidable by using the linear profile but also result in higher efficiency than the linear profile. Furthermore, the study shows that there is a strong tradeoff between the relaxation in the plant ramp rate and the time-average thermal efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Front-End Engineering Design Study for Retrofit Post-Combustion Carbon Capture on a Natural Gas Combined Cycle Power Plant

The objective of the project is to conduct a Front-End Engineering Design (FEED) study to determine the technical and economic feasibility of installing a retrofit, post-combustion, carbon capture facility on a commercially operating, natural gas-fired, combined cycle (NGCC) power plant. The Electric Power Research Institute (EPRI), California Resources Corporation (CRC), and Fluor Corporation used Fluor's Econamine FG Plus SM (EFG+) conducted the FEED study for capturing CO 2 produced by CRC's 550 MWe Elk Hills Power Plant (EHPP), located in the Elk Hills Oil Field near Tupman, Kern County, California. The EHPP was commissioned in 2003 and is powered by two General Electric 7FA gas turbines, with two heat recovery steam generators (HRSGs) providing steam to a General Electric D11 steam turbine. The target capture amount is 4,000 tonnes CO 2 /day for use in either enhanced oil recovery or dedicated geological saline storage located on CRC property at or nearby EHPP. This CO 2 is captured from a combination of the CO 2 emitted from the flue gas from EHPP and the flue gas generated from a natural gas-fired auxiliary boiler that supplies steam to the EFG+ process.

03 NATURAL GAS↗