Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “municipalities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Municipality Level Simulations of Dengue Fever Incidence in Puerto Rico Using Ground Based and Remotely Sensed Climate Data

Dengue fever (DF) is caused by a virus transmitted between humans and Aedes genus mosquitoes through blood feeding. In recent decades incidence of the disease has drastically increased in the tropical Americas, culminating with the Pan American outbreak in 2010 which resulted in 1.7 million reported cases. In Puerto Rico dengue is endemic, however, there is significant inter‐annual, intraannual, and spatial variability in case loads. Variability in climate and the environment, herd immunity and virus genetics, and demographic characteristics may all contribute to differing patterns of transmission both spatially and temporally. Knowledge of climate influences on dengue incidence could facilitate development of early warning systems allowing public health workers to implement appropriate transmission intervention strategies. In this study, we simulate dengue incidence in several municipalities in Puerto Rico using population and meteorological data derived from ground based stations and remote sensing instruments. This data was used to drive a process based model of vector population development and virus transmission. Model parameter values for container composition, vector characteristics, and incubation period were chosen by employing a Monte Carlo approach. Multiple simulations were performed for each municipality and the results were compared with reported dengue cases. The best performing simulations were retained and their parameter values and meteorological input were compared between years and municipalities. Parameter values varied by municipality and year illustrating the complexity and sensitivity of the disease system. Local characteristics including the natural and built environment impact transmission dynamics and produce varying responses to meteorological conditions.

Remote Sensing↗

Application of NASA-developed technology to the automatic control of municipal sewage treatment plants

A search was made of NASA developed technology and commercial technology for process control sensors and instrumentation which would be applicable to the operation of municipal sewage treatment plants. Several notable items were found from which process control concepts were formulated that incorporated these items into systems to automatically operate municipal sewage treatment plants. A preliminary design of the most promising concept was developed into a process control scheme for an activated sludge treatment plant. This design included process control mechanisms for maintaining constant food to sludge mass (F/M) ratio, and for such unit processes as primary sedimentation, sludge wastage, and underflow control from the final clarifier.

Hiser, L. L.↗

An analysis of the market potential of water hyacinth-based systems for municipal wastewater treatment

The potential U.S. market for tertiary municipal wastewater treatment facilities which make use of water hyacinths was investigated. A baseline design was developed which approximates the "typical" or "average" situation under which hyacinth-based systems can be used. The total market size for tertiary treatment was then estimated for those geographical regions in which hyacinths appear to be applicable. Market penetration of the baseline hyacinth system when competing with conventional chemical and physical processing systems was approximated, based primarily on cost differences. A limited analysis was made of the sensitivity of market penetration to individual changes in these assumptions.

Robinson, A. C.↗

Trace elemental characteristics of aerosols emitted from municipal incinerators

As part of a continuing investigation of high temperature combustion aerosols, elemental composition of size differentiated aerosols emitted from a local municipal incinerator was studied. Aerosols were aerodynamically separated into eight diameter groups ranging from 0.43 mm to 20 mm, collected, and analyzed by charged particle induced X-ray emission technique. On line data collection and reduction codes generated aerial densities for elements from Na to U with sensitivities in the ng/cu m range for most elements. From the total weights of aerosols collected per stage, their size distribution was determined to be bimodal, with one group centered at a diameter of 0.54 mm and the other at a diameter of 5.6 mm. Measured elemental concentrations in various size ranges indicate that K and S show a strong tendency to concentrate on aerosol surfaces. A weaker trend for surface preference was also observed for Mn and Ni, but other elements show no such trend.

Singh, J. J.↗

Air pollution from aircraft operations at San Jose Municipal Airport, California

The amount of air pollution discharged by arriving and departing aircraft at the San Jose Municipal Airport was estimated. These estimates were made for each one hour interval of a summer weekday in 1977. The contributions of both general aviation (personal and business aircraft) and certified air carriers (scheduled airliners) were considered. The locations at which the pollutants were discharged were estimated by approximating the flight paths of arriving and departing aircraft. Three types of pollutants were considered: carbon monoxide, hydrocarbons, and oxides of nitrogen.

Schairer, E. T.↗

Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

Source record↗

Sacremento Municipal Utility District 100-MW sub e photovoltaic plant

A status report on plans for the Sacramento Municipal Utility District (SMUD) 1-MW photovoltaic power plant is presented. DOE, the California Energy Commission, and SMUD will fund the project cooperatively. Emphasis is placed on the details of the government contract/cooperation agreement.

Powell, R. V.↗

Cost of phosphate removal in municipal wastewater treatment plants

Construction and operating costs of advanced wastewater treatment for phosphate removal at municipal wastewater treatment plants have been investigated on orders from the Federal Environmental Bureau in Berlin. Particular attention has been paid to applicable kinds of precipitants for pre-, simultaneous and post-precipitation as well as to different phosphate influent and effluent concentrations. The article offers detailed comments on determination of technical data, investments, capital costs, operating costs and annual costs as well as potential cost reductions resulting from precipitation. Selected results of the cost investigation are shown in graphical form as specific investments, operating and annual costs depending on wastewater flow.

Schuessler, H.↗

Toa Baja Disasters: Utilizing Open-Source Earth Observations to Inform the Toa Baja Municipality’s Flood Mitigation Efforts and Educate the Public

Toa Baja, located just west of San Juan in Puerto Rico, is known as “the underwater city” due to its propensity to flood. The city contains the mouth of the island’s longest river, Río de la Plata, which drains into the Atlantic Ocean on the northern edge of the municipality. Proximity to these major water features and the flat, low terrain contribute to the flood-prone nature of the area. During tropical storm events, such as Hurricane Maria in 2017, Toa Baja experienced inundation of up to 20 feet. Changes in the global climate system are causing more intense and frequent tropical storms, making places like Toa Baja subject to irreparable damage. This NASA DEVELOP project collaborated with the Municipio Autónomo de Toa Baja, ResilientSEE, and the Massachusetts Institute of Technology Urban Risk Lab to supplement recent 2018 Federal Emergency Management Agency Hydraulic Engineering Centers-River Analysis System flood maps, which designated 63% of the area as a flood plain. The analysis provides a high-resolution interpretation of flood susceptibility using a variety of factors that collectively influence the likelihood of flooding. Sentinel-1 C-Band Synthetic Aperture Radar (C-SAR) data processed with Google Earth Engine scripting identified historical inundation and was used for validation purposes. Socioeconomic factors were combined with the inundation layer producing a final risk output. These outputs will improve public understanding of exposure to flood risk in Toa Baja and provide scientific evidence for flood mitigation advocacy.

Disasters↗

Toa Baja Disasters: Utilizing Open-Source Earth Observations to Inform the Toa Baja Municipality’s Flood Mitigation Efforts and Educate the Public

Toa Baja, located just west of San Juan in Puerto Rico, is known as “the underwater city” due to its propensity to flood. The city contains the mouth of the island’s longest river, Río de la Plata, which drains into the Atlantic Ocean on the northern edge of the municipality. Proximity to these major water features and the flat, low terrain contribute to the flood-prone nature of the area. During tropical storm events, such as Hurricane Maria in 2017, Toa Baja experienced inundation of up to 20 feet. Changes in the global climate system are causing more intense and frequent tropical storms, making places like Toa Baja subject to irreparable damage. This NASA DEVELOP project collaborated with the Municipio Autonómo de Toa Baja, ResilientSEE, and the Massachusetts Institute of Technology Urban Risk Lab to supplement recent 2018 Federal Emergency Management Agency Hydraulic Engineering Centers-River Analysis System flood maps, which designated 63% of the area as a flood plain. The analysis provides a high-resolution interpretation of flood susceptibility using a variety of factors that collectively influence the likelihood of flooding. Sentinel-1 C-Band Synthetic Aperture Radar (C-SAR) data processed with Google Earth Engine scripting identified historical inundation and was used for validation purposes. Socioeconomic factors were combined with the inundation layer producing a final risk output. These outputs will improve public understanding of exposure to flood risk in Toa Baja and provide scientific evidence for flood mitigation advocacy.

Disasters↗

Utilizing Open-Source Earth Observations to Inform the Toa Baja Municipality’s Flood Risk Mitigation Efforts and Educate the Public

Global climate changes contribute to more intense and frequent tropical storms, subjecting places like Toa Baja, Puerto Rico to critical damage. Known as “the underwater city” due to its propensity to flood, residents of Toa Baja face constant flood risk. During extreme tropical storm events, such as Hurricane Maria in 2017, residents experienced up to 20 feet of inundation. The NASA DEVELOP National Program collaborated with the Municipio Autónomo de Toa Baja, ResilientSEE-PR, and the MIT Urban Risk Lab to supplement 2018 FEMA HEC-RAS flood maps that designate 63% of Toa Baja as a flood plain. This analysis provides a high-resolution interpretation of flood risk through two lenses; susceptibility and vulnerability. For this analysis, susceptibility consists of nine weighted layers: NDVI, landcover, slope, elevation, topographic wetness index, height above nearest drainage, saturated hydraulic conductivity, distance to water, and storm surge. These factors are consistently used to evaluate susceptibility to flood, but their weights vary by analysis. Vulnerability consists of population, informal settlements, and building density, which were given equal weight. Susceptibility and vulnerability were combined to map flood risk. This analysis used a bivariate legend to understand the different levels of risk along a spectrum from low susceptibility and low vulnerability (low risk) to high susceptibility and high vulnerability (high risk). Data processed in Google Earth Engine, which identified historical inundation on various occasions, were used to validate the flood susceptibility layers. Results showed 89% of areas designated as high susceptibility are located within the floodway designated by the FEMA HEC-RAS maps. The eastern region of Toa Baja is most at risk for flooding due to high susceptibility to flooding along with a high density of population, buildings, and informal settlements. The resulting map also reveals the presence of smaller high-risk areas all around the municipality. This analysis provides scientific evidence for flood risk mitigation in Toa Baja by highlighting areas that might be impacted by strong floods in the future. Additionally, these results are communicated in an Esri ArcGIS StoryMap, an accessible platform that can easily inform the public about the flood risk in their neighborhood.

Adriana Le Compte↗

Production of gaseous fuel by pyrolysis of municipal solid waste

Pilot plant tests were conducted on a simulated solid waste which was a mixture of shredded newspaper, wood waste, polyethylene plastics, crushed glass, steel turnings, and water. Tests were conducted at 1400 F in a lead-bath pyrolyser. Cold feed was deaerated by compression and was dropped onto a moving hearth of molten lead before being transported to a sealed storage container. About 80 percent of the feed's organic content was converted to gaseous products which contain over 90 percent of the potential waste energy; 12 percent was converted to water; and 8 percent remained as partially pyrolyzed char and tars. Nearly half of the carbon in the feed is converted to benzene, toluene and medium-quality fuel gas, a potential credit of over $25 per ton of solid waste. The system was shown to require minimal preprocessing and less sorting then other methods.

Crane, T. H.↗

Evaluation of methods of reducing community noise impact around San Jose municipal airport

A computer simulation of the airport noise impact on the surrounding communities was used to evaluate alternate operational procedures, improved technology, and land use conversion as methods of reducing community noise impact in the airport vicinity. In addition, a constant density population distribution was analyzed for possible application to other airport communities with fairly uniform population densities and similar aircraft operational patterns. The introduction of sound absorption material (SAM) was found to reduce community noise annoyance by over 25 percent, and the introduction of refan was found to reduce community annoyance by over 60 percent. Replacing the present aircraft was found to reduce the noise problem to very small proportions, and the introduction of an advanced technology twin was found to essentially eliminate the community noise problem.

Glick, J. M.↗

The impact of municipal refuse utilization on energy and our environment

The incinerator/boiler configuration is stressed as the most reliable method of waste utilization. It is also pointed out that the high cost of refuse disposal and the ever increasing cost of energy, have made this method attractive. A plan is outlined for operating a waste utilization plant. Community participation is encouraged in investigating the feasibility of refuse to energy facilities in their area.

Source record↗

municipal recreation center is heated and cooled by solar energy

Major fraction of energy requirements for community building is ksupplied by Sun. The 238 flat plate solar collectors are roof mounted on single story structure enclosing gymnasium, locker area, and health care clinic; heat exchanger transfers collected energy to 6,000 gallon storage tank. Final report chronicles project from inception to completion, documenting performance, costs, operating modes, and data acquisition system. Appendix contains manufacturers' product literature and engineering drawings.

Source record↗