Engineering PapersSearch

SEARCH · Engineering Papers

Results for “multiple scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An algebraic convolution formulation for multiple-scattering correction in small-angle neutron scattering

Multiple scattering in small-angle neutron scattering (SANS) redistributes spectral weight and distorts structural interpretation, particularly for thick or strongly scattering samples. We develop a finite-dimensional spectral desmearing framework that corrects multiple scattering without resorting to integral transforms or model-dependent extrapolation. The primary intensity is expanded in an orthonormal basis adapted to the isotropic transverse-momentum measure, under which convolution reduces to a recursive tensor contraction, allowing the Poisson-weighted multiple-scattering series to be evaluated directly in a finite-dimensional basis representation. This formulation yields a stable forward–inverse mapping between apparent and primary spectra. Numerical tests demonstrate convergence under repeated convolution and accurate recovery of the single-scattering intensity. Application to SANS measurements collected at multiple neutron facilities, including the Spallation Neutron Source, the High Flux Isotope Reactor, and the Institut Laue-Langevin, shows the quantitative reconstruction of the underlying primary spectrum across a wide range of transmission conditions, including strongly attenuating samples. Here, the method provides a stable, model-agnostic framework for multiple-scattering correction in SANS and enables consistent structural interpretation across instruments and scattering regimes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN

Harnessing emergent multiple scattering resonances in a photonic glass structure for photoelectrochemical energy conversion

Light trapping nanostructures are often necessary to improve carrier collection yields in semiconductor photoelectrodes with intrinsically poor electron transport. Photonic crystal templates can generate tailorable light trapping via periodic and precise nanostructure, though this is not a scalable strategy for photoelectrochemical (PEC) applications. It is therefore critical to identify alternative mechanisms for light trapping that tolerate disorder. Light trapping in disordered media is generated by the diffusive transport caused by multiple scattering. In some cases, multiple scattering can generate resonances that resemble those observed in photonic crystals. While resonant multiple scattering is a disorder tolerant light trapping mechanism, it is unclear if the effect is sufficiently adaptable, or even useful, for PEC applications. Here, we describe a photonic omission glass, a nanostructure that can controllably induce resonances in multiple scattering transport. We characterized the emergence of these resonances after coating a disordered SiO 2 colloidal structure with a layer of TiO 2 , which functions both as dielectric contrast and as a light absorbing semiconductor. We show in finite element simulations and spectroscopic characterization that the resonant multiple scattering effect improves light trapping near the interface between the structure and the bulk electrolyte. This effect, coupled with the increased electrochemically active surface area, results in a hierarchically structured TiO 2 photoanode with orders of magnitude higher photocurrents compared to an equivalent planar photoanode for PEC reactions such as alkaline water oxidation. We show that controlling this resonant multiple scattering effect can be advantageous for improving PEC energy conversion in disordered photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Muon momentum reconstruction in ICARUS-T600 LArTPC via Multiple Scattering

The SBN program at Fermilab investigates the possible existence of eV-scale sterile neutrinos. This work focuses on reconstructing muon momentum in $\nu$-Ar interactions within the ICARUS-T600 LArTPC detector using Multiple Coulomb Scattering (MCS), the only viable method for non-contained muons. Two algorithms are evaluated: the Gran Sasso algorithm (2D, Collection view) and the MicroBooNE algorithm (3D angles), applied to 2391 simulated and 2255 real stopping muon tracks (0.4-1 GeV/c). Performance is assessed via bias and resolution, using range-based momentum as a reference. Two enhanced versions of the Gran Sasso algorithm are also developed: one combining all three wire plane views, and one using 3D angles. Results show that the MicroBooNE algorithm performs slightly better, with resolution down to 14\% in simulation and 16\% in real data. These improvements significantly boost $\nu_\mu$ CC statistics, enhancing sensitivity to $\nu_\mu$ disappearance and 3+1 oscillation signals.

Chiello, Giovanni [Pisa U.] (ORCID:000900064571071

Heavy dark matter in white dwarfs: multiple-scattering capture and thermalization

We present an improved treatment for the scattering of heavy dark matter from the ion constituents of a white dwarf. In the heavy dark matter regime, multiple collisions are required for the dark matter to become gravitationally captured. Our treatment incorporates all relevant physical effects including the dark matter trajectories, nuclear form factors, and radial profiles for the white dwarf escape velocity and target number densities. Our capture rates differ by orders of magnitude from previous estimates, which have typically used approximations developed for dark matter scattering in the Earth. We also compute the time for the dark matter to thermalize in the center of the white dwarf, including in-medium effects such as phonon emission and absorption from the ionic lattice in the case where the star has a crystallized core. We find much shorter thermalization timescales than previously estimated, especially if the white dwarf core has crystallized. We illustrate the importance of our improved approach by determining the cross section required for accumulated asymmetric dark matter to self-gravitate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Random forest prediction of crystal structure from electron diffraction patterns incorporating multiple scattering

Diffraction is the most common method to solve for unknown or partially known crystal structures. However, it remains a challenge to determine the crystal structure of a new material that may have nanoscale size or heterogeneities. Here, in this study, we train an architecture of hierarchical random forest models capable of predicting the crystal system, space group, and lattice parameters from one or more unknown two-dimensional electron diffraction patterns. Our initial model correctly identifies the crystal system of a simulated electron diffraction pattern from a 20-nm-thick specimen of arbitrary orientation 67% of the time. We achieve a topline accuracy of 79% when aggregating predictions from ten patterns of the same material but different zone axes. The space group and lattice predictions range from 70% to 90% accuracy and median errors of 0.01-0.5Å, respectively, for cubic, hexagonal, trigonal, and tetragonal crystal systems while being less reliable on orthorhombic and monoclinic systems. We apply this architecture to a four-dimensional scanning transmission electron microscopy scan of gold nanoparticles, where it accurately predicts the crystal structure and lattice constants. These random forest models can be used to significantly accelerate the analysis of electron diffraction patterns, particularly in the case of unknown crystal structures. Additionally, due to the speed of inference, these models could be integrated into live transmission electron microscopy experiments, allowing real-Time labeling of a specimen.

36 MATERIALS SCIENCE

Demystifying Piecewise and Localized Scatter Correction Methods

Multiplicative scatter is a common source of noise in near-infrared spectroscopy and other related instrumental techniques. A wide variety of methods are commonly used for the correction of multiplicative scatter. However, the majority of such methods assume that the parameters that describe the scatter are constant throughout the measured spectrum, which is often not the case. This work investigates a family of methods that perform scatter correction using local regions of neighboring wavelengths in order to better account for wavelength-dependent scattering. The methods in question are piecewise standard normal variate, localized standard normal variate, piecewise multiplicative scatter correction, and localized multiplicative scatter correction. This work describes the theoretical and algorithmic foundations of the family of local region-based scatter correction methods and compares their application and optimization at a qualitative and quantitative level using several datasets.

NIR spectroscopy

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera

On measuring stimulated photon–photon scattering using multiple ultraintense lasers

Stimulated photon–photon scattering is a predicted consequence of quantum electrodynamics that has yet to be measured directly. Measuring the cross section for stimulated photon–photon scattering is the aim of a flagship experiment for NSF OPAL, a proposed laser user facility with two, 25-PW beamlines. We present optimized experimental designs for achieving this challenging and canonical measurement. A family of experimental geometries is identified that satisfies the momentum- and energy-matching conditions for two selected laser frequency options. Numerical models predict a maximum signal exceeding 1000 scattered photons per shot at the experimental conditions envisaged at NSF OPAL. Experimental requirements on collision geometry, polarization, cotiming and copointing, background suppression, and diagnostic technologies are investigated numerically. These results confirm that a beam cotiming shorter than the pulse duration and control of the copointing on a scale smaller than the shortest laser wavelength are needed to robustly scatter photons on a per-shot basis. Finally, we assess the bounds that a successful execution of this experiment may place on the mass scale of Born–Infeld nonlinear electrodynamics beyond the standard model of physics.

Beyond the Standard Model

Bayesian inference of nuclear-matter density from proton scattering

Background: Proton elastic scattering at intermediate energy is widely employed as a tool for determining the matter radius of atomic nuclei. Here, the sensitivity of the approach relies on high-resolution measurements at small scattering angles and low-momentum transfer. Under these conditions, the Glauber multiple scattering theory accurately describes the proton-nucleus elastic cross section. Purpose: Investigate the sensitivity of the Glauber multiple scattering theory to uncertainties associated with input parameters such as the nuclear-matter density distribution and nucleon-nucleon data. Method: A joint Bayesian inference was performed using 12 angular distributions of elastic scattering at different energies on 58 Ni, 90 Zr, and 208 Pb targets. A Metropolis-Hastings algorithm was implemented to make an uncertainty quantification analysis for the input parameters used in the Glauber multiple scattering theory. Results: The experimental cross sections were fitted simultaneously using a joint Bayesian inference approach. Posterior probability density distributions of 42 input parameters were obtained from the analysis. A moderate correlation between the nuclear density parameters and the nucleon-nucleon cross sections was found. This correlation impacts the extraction of the nuclear-matter radius. Conclusions: The present analysis provided a consistent method for extracting the nuclear-matter density distribution of 58 Ni, 90 Zr, and 208 Pb from data across different incident energies. Due to the correlation of the nucleon-nucleon cross sections with the other input parameters, a constrained Bayesian inference using free nucleon-nucleon cross section data was performed. The nuclear-matter radii obtained from the analysis are in good agreement with multiple results reported in the literature.

190 ≤ A ≤ 219

Improved Muon Energy Estimation Using a Detailed Model of Multiple Coulomb Scattering in the MicroBooNE LArTPC

We present an improved technique for estimating a muon's energy by measuring the deflections along its path inside the MicroBooNE detector from multiple Coulomb scattering (MCS). This approach implements several innovations that better capture detector non-idealizations compared to previous MCS-based muon energy estimators. As a result, it achieves improved resolution, reduced bias, and better data-model agreement. Using model simulation, for fully contained events the estimated bias is within 1\% and the estimated resolution narrows from 10\% to 4.3\% as muon energy increases from 0.1\,GeV to 2\,GeV. For events with particles exiting the detector volume, at least a meter of reconstructed muon track, and a muon energy below 2\,GeV, the estimated bias is less than 2\% and the estimated resolution varies from 7\% to 17\% over muon energy. These demonstrate significant improvements over the performance of previous work using an MCS-based energy estimator at MicroBooNE~\cite{mcs_2017}, which exhibited approximately twice worse resolution and a bias of 20\% over the same energy region. Data-model goodness-of-fit studies are used to validate the estimator's performance on data, showing good agreement within model uncertainties.

Cooper-Troendle, London [U. Pittsburgh (main); Fer

Multiple Coulomb scattering for muon energy reconstruction in SBND Monte Carlo simulations

The Short Baseline Near Detector (SBND) is a liquid argon time projection chamber (LArTPC) located 110 meters downstream of the Booster Neutrino Beam target at Fermilab \cite{SBN}. The LArTPC is a detector technology with unprecedented position and calorimetric resolution for precise neutrino studies. The most dominant neutrino interaction topology in SBND is charged-current quasi-elastic muon neutrino-argon interactions, where the final state consists of a muon and a proton. Here, muons often travel long distances, sometimes exiting the detector before stopping. This loss of information creates a challenge for accurate energy estimation. There have been efforts in the MicroBooNE and ICARUS collaborations to improve energy estimation using a phenomenon known as Multiple Coulomb Scattering (MCS), which describes the jagged path taken by muons through a detector due to continuous Coulomb interactions with argon atoms. Building on these efforts, my project aims to improve an MCS-based approach to estimating the energies of exiting muons in SBND.

Puig, Xilonem Angeles [Mt. Holyoke Coll.; Fermilab

PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval

Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple scattering further complicates interpretation. These effects degrade resolution, particularly in conventional reconstruction algorithms, which assume linearity. Particle averaging can reduce such issues but is unsuitable for heterogeneous or dynamic samples ubiquitous in biology, chemistry, and materials sciences. Here, we develop a phase retrieval-based cryo-ET method, PhaseT3M. We experimentally demonstrate its application to an approximately 7 nm Co3O4 nanoparticle on an approximately 30 nm carbon substrate, achieving a maximum resolution of 1.6 Å, surpassing conventional limits using standard cryo-TEM equipment. PhaseT3M uses a multislice model for multiple scattering and Bayesian optimization for alignment and computational aberration correction, with a positivity constraint to recover ‘missing wedge’ information. Applied directly to biological particles, it enhances reconstruction quality and reduces artifacts, establishing a standard for routine 3D imaging with phase contrast.

Biophysics

Flavor, transverse momentum, and azimuthal dependence of charged pion multiplicities in semi-inclusive deep-inelastic scattering with 10.6 GeV electrons

Measurements of semi-inclusive deep-inelastic scattering multiplicities for 𝜋 + and 𝜋 − from proton and deuteron targets are reported on a grid of hadron kinematic variables 𝑧, 𝑃 𝑇 , and 𝜙* for leptonic kinematic variables in the range 0.3<𝑥<0.6 and 3<𝑄 2 <5GeV 2 . Data were acquired in 2018 and 2019 at Jefferson Lab Hall C with a 10.6 GeV electron beam impinging on 10-cm-long liquid hydrogen and deuterium targets. Scattered electrons and charged pions were detected in the High Momentum Spectrometer and Super High Momentum Spectrometer, respectively. The multiplicities were fitted for each bin in (𝑥,𝑄 2 ,𝑧,𝑃𝑡) to extract the 𝜙*—independent 𝑀 0 and the azimuthal modulations ⟨cos⁡(𝜙*)⟩ and ⟨cos⁡(2⁢𝜙*)⟩. The 𝑃𝑡 dependence of the 𝑀 0 results was found to be remarkably consistent for the four cases studied: 𝑒⁢𝑝→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑝→𝑒⁢𝜋 − ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 − ⁢𝑋 over the range 0GeV<𝑃 𝑡 <0.4GeV, as were the multiplicities evaluated near 𝜙*=180∘ over the extended range 0GeV<𝑃 𝑡 <0.7GeV. The Gaussian widths of the 𝑃 𝑡 dependence exhibit a quadratic increase with 𝑧. The cos⁡(𝜙*) modulations were found to be consistent with zero for 𝜋 + , in agreement with previous world data, while the 𝜋 − moments were, in many cases, significantly greater than zero. The cos⁡(2⁢𝜙*) modulations were found to be consistent with zero. The higher statistical precision of this dataset of about 20 000 individual multiplicity values, compared with previously published data, should allow improved determinations of quark transverse momentum distributions and higher twist contributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Ab initio leading order effective potential for elastic proton scattering based on the symmetry-adapted no-core shell model

Calculating microscopic optical potentials for elastic scattering at intermediate energies from light nuclei in an ab initio fashion within the Watson expansion has been established within the last few years. Based on the Watson expansion of the multiple scattering series, we employ a nonlocal translationally invariant nuclear density derived within the symmetry-adapted no-core shell model (SA-NCSM) framework from a chiral next-to-next-to-leading order (NNLO) nucleon-nucleon interaction and the very same interaction for a consistent full-folding calculation of the effective (optical) potential for nucleon-nucleus scattering for medium-heavy nuclei. The leading order effective (optical) folding potential is computed by integrating over a translationally invariant SA-NCSM one-body scalar density, spin-projected momentum distribution, and the Wolfenstein amplitudes 𝐴, 𝐶, and 𝑀. The resulting nonlocal potentials serve as input for a momentum space Lippmann-Schwinger equation. In the SA-NCSM, the model space is systematically up-selected using Sp⁡(3,ℝ) symmetry considerations. For the light nucleus of 6 He, we establish a systematic selection scheme in the SA-NCSM for scattering observables. Then, we apply this scheme to calculations of scattering observables, such as differential cross sections, analyzing powers, and spin rotation functions for elastic proton scattering from 20 Ne and 40 Ca in the energy regime between 65 and 200 MeV, and compare to available data. Furthermore, our calculations show that the leading order effective nucleon-nucleus potential in the Watson expansion of multiple scattering theory obtained from an up-selected SA-NCSM model space describes 40 Ca elastic scattering observables reasonably well to about 60 degrees in the center-of-mass frame, which coincides roughly with the validity of the NNLO chiral interaction used to calculate both the nucleon-nucleon amplitudes and the one-body scalar and spin nuclear densities.

Ab initio calculations

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES

Absence of magnetic order in epitaxial RuO 2 revealed by x-ray linear dichroism

Recently the topic of altermagnetism has attracted tremendous attention, and RuO 2 has been demonstrated to be one of the most promising altermagnetic candidates. However, disputes still remain on the existence of magnetic order in RuO 2 . Here in this work, we employ x-ray linear dichroism (XLD), a widely utilized technique for characterizing antiferromagnets, in conjunction with photoemission electron microscopy and multiple scattering calculation to provide clear evidence of the absence of magnetic order in epitaxial RuO 2 films. The observed XLD signal is nearly invariant with temperature and independent of cooling-field direction, in stark contrast to the substantial magnetic-order-related XLD signal predicted by multiple scattering calculation. This finding strongly suggests a nonmagnetic origin for RuO 2 . Furthermore, we observed significantly distinct XLD signals at the Ru M 3 and O K edges in RuO 2 films grown on TiO 2 substrate with different surface orientations, which can be attributed to the low-symmetry crystal field. In conclusion, these results unequivocally demonstrate the absence of magnetic order in RuO 2 and establish XLD measurement as a robust technique for probing the low-symmetry magnetic materials.

Wang, Siyu [University of Science and Technology o