Engineering PapersSearch

SEARCH · Engineering Papers

Results for “multiple scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An algebraic convolution formulation for multiple-scattering correction in small-angle neutron scattering

Multiple scattering in small-angle neutron scattering (SANS) redistributes spectral weight and distorts structural interpretation, particularly for thick or strongly scattering samples. We develop a finite-dimensional spectral desmearing framework that corrects multiple scattering without resorting to integral transforms or model-dependent extrapolation. The primary intensity is expanded in an orthonormal basis adapted to the isotropic transverse-momentum measure, under which convolution reduces to a recursive tensor contraction, allowing the Poisson-weighted multiple-scattering series to be evaluated directly in a finite-dimensional basis representation. This formulation yields a stable forward–inverse mapping between apparent and primary spectra. Numerical tests demonstrate convergence under repeated convolution and accurate recovery of the single-scattering intensity. Application to SANS measurements collected at multiple neutron facilities, including the Spallation Neutron Source, the High Flux Isotope Reactor, and the Institut Laue-Langevin, shows the quantitative reconstruction of the underlying primary spectrum across a wide range of transmission conditions, including strongly attenuating samples. Here, the method provides a stable, model-agnostic framework for multiple-scattering correction in SANS and enables consistent structural interpretation across instruments and scattering regimes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN

Harnessing emergent multiple scattering resonances in a photonic glass structure for photoelectrochemical energy conversion

Light trapping nanostructures are often necessary to improve carrier collection yields in semiconductor photoelectrodes with intrinsically poor electron transport. Photonic crystal templates can generate tailorable light trapping via periodic and precise nanostructure, though this is not a scalable strategy for photoelectrochemical (PEC) applications. It is therefore critical to identify alternative mechanisms for light trapping that tolerate disorder. Light trapping in disordered media is generated by the diffusive transport caused by multiple scattering. In some cases, multiple scattering can generate resonances that resemble those observed in photonic crystals. While resonant multiple scattering is a disorder tolerant light trapping mechanism, it is unclear if the effect is sufficiently adaptable, or even useful, for PEC applications. Here, we describe a photonic omission glass, a nanostructure that can controllably induce resonances in multiple scattering transport. We characterized the emergence of these resonances after coating a disordered SiO 2 colloidal structure with a layer of TiO 2 , which functions both as dielectric contrast and as a light absorbing semiconductor. We show in finite element simulations and spectroscopic characterization that the resonant multiple scattering effect improves light trapping near the interface between the structure and the bulk electrolyte. This effect, coupled with the increased electrochemically active surface area, results in a hierarchically structured TiO 2 photoanode with orders of magnitude higher photocurrents compared to an equivalent planar photoanode for PEC reactions such as alkaline water oxidation. We show that controlling this resonant multiple scattering effect can be advantageous for improving PEC energy conversion in disordered photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state

Muon momentum reconstruction in ICARUS-T600 LArTPC via Multiple Scattering

The SBN program at Fermilab investigates the possible existence of eV-scale sterile neutrinos. This work focuses on reconstructing muon momentum in $\nu$-Ar interactions within the ICARUS-T600 LArTPC detector using Multiple Coulomb Scattering (MCS), the only viable method for non-contained muons. Two algorithms are evaluated: the Gran Sasso algorithm (2D, Collection view) and the MicroBooNE algorithm (3D angles), applied to 2391 simulated and 2255 real stopping muon tracks (0.4-1 GeV/c). Performance is assessed via bias and resolution, using range-based momentum as a reference. Two enhanced versions of the Gran Sasso algorithm are also developed: one combining all three wire plane views, and one using 3D angles. Results show that the MicroBooNE algorithm performs slightly better, with resolution down to 14\% in simulation and 16\% in real data. These improvements significantly boost $\nu_\mu$ CC statistics, enhancing sensitivity to $\nu_\mu$ disappearance and 3+1 oscillation signals.

Chiello, Giovanni [Pisa U.] (ORCID:000900064571071

Demystifying Piecewise and Localized Scatter Correction Methods

Multiplicative scatter is a common source of noise in near-infrared spectroscopy and other related instrumental techniques. A wide variety of methods are commonly used for the correction of multiplicative scatter. However, the majority of such methods assume that the parameters that describe the scatter are constant throughout the measured spectrum, which is often not the case. This work investigates a family of methods that perform scatter correction using local regions of neighboring wavelengths in order to better account for wavelength-dependent scattering. The methods in question are piecewise standard normal variate, localized standard normal variate, piecewise multiplicative scatter correction, and localized multiplicative scatter correction. This work describes the theoretical and algorithmic foundations of the family of local region-based scatter correction methods and compares their application and optimization at a qualitative and quantitative level using several datasets.

NIR spectroscopy

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera

On measuring stimulated photon–photon scattering using multiple ultraintense lasers

Stimulated photon–photon scattering is a predicted consequence of quantum electrodynamics that has yet to be measured directly. Measuring the cross section for stimulated photon–photon scattering is the aim of a flagship experiment for NSF OPAL, a proposed laser user facility with two, 25-PW beamlines. We present optimized experimental designs for achieving this challenging and canonical measurement. A family of experimental geometries is identified that satisfies the momentum- and energy-matching conditions for two selected laser frequency options. Numerical models predict a maximum signal exceeding 1000 scattered photons per shot at the experimental conditions envisaged at NSF OPAL. Experimental requirements on collision geometry, polarization, cotiming and copointing, background suppression, and diagnostic technologies are investigated numerically. These results confirm that a beam cotiming shorter than the pulse duration and control of the copointing on a scale smaller than the shortest laser wavelength are needed to robustly scatter photons on a per-shot basis. Finally, we assess the bounds that a successful execution of this experiment may place on the mass scale of Born–Infeld nonlinear electrodynamics beyond the standard model of physics.

Beyond the Standard Model

Bayesian inference of nuclear-matter density from proton scattering

Background: Proton elastic scattering at intermediate energy is widely employed as a tool for determining the matter radius of atomic nuclei. Here, the sensitivity of the approach relies on high-resolution measurements at small scattering angles and low-momentum transfer. Under these conditions, the Glauber multiple scattering theory accurately describes the proton-nucleus elastic cross section. Purpose: Investigate the sensitivity of the Glauber multiple scattering theory to uncertainties associated with input parameters such as the nuclear-matter density distribution and nucleon-nucleon data. Method: A joint Bayesian inference was performed using 12 angular distributions of elastic scattering at different energies on 58 Ni, 90 Zr, and 208 Pb targets. A Metropolis-Hastings algorithm was implemented to make an uncertainty quantification analysis for the input parameters used in the Glauber multiple scattering theory. Results: The experimental cross sections were fitted simultaneously using a joint Bayesian inference approach. Posterior probability density distributions of 42 input parameters were obtained from the analysis. A moderate correlation between the nuclear density parameters and the nucleon-nucleon cross sections was found. This correlation impacts the extraction of the nuclear-matter radius. Conclusions: The present analysis provided a consistent method for extracting the nuclear-matter density distribution of 58 Ni, 90 Zr, and 208 Pb from data across different incident energies. Due to the correlation of the nucleon-nucleon cross sections with the other input parameters, a constrained Bayesian inference using free nucleon-nucleon cross section data was performed. The nuclear-matter radii obtained from the analysis are in good agreement with multiple results reported in the literature.

190 ≤ A ≤ 219

Improved Muon Energy Estimation Using a Detailed Model of Multiple Coulomb Scattering in the MicroBooNE LArTPC

We present an improved technique for estimating a muon's energy by measuring the deflections along its path inside the MicroBooNE detector from multiple Coulomb scattering (MCS). This approach implements several innovations that better capture detector non-idealizations compared to previous MCS-based muon energy estimators. As a result, it achieves improved resolution, reduced bias, and better data-model agreement. Using model simulation, for fully contained events the estimated bias is within 1\% and the estimated resolution narrows from 10\% to 4.3\% as muon energy increases from 0.1\,GeV to 2\,GeV. For events with particles exiting the detector volume, at least a meter of reconstructed muon track, and a muon energy below 2\,GeV, the estimated bias is less than 2\% and the estimated resolution varies from 7\% to 17\% over muon energy. These demonstrate significant improvements over the performance of previous work using an MCS-based energy estimator at MicroBooNE~\cite{mcs_2017}, which exhibited approximately twice worse resolution and a bias of 20\% over the same energy region. Data-model goodness-of-fit studies are used to validate the estimator's performance on data, showing good agreement within model uncertainties.

Cooper-Troendle, London [U. Pittsburgh (main); Fer

Multiple Coulomb scattering for muon energy reconstruction in SBND Monte Carlo simulations

The Short Baseline Near Detector (SBND) is a liquid argon time projection chamber (LArTPC) located 110 meters downstream of the Booster Neutrino Beam target at Fermilab \cite{SBN}. The LArTPC is a detector technology with unprecedented position and calorimetric resolution for precise neutrino studies. The most dominant neutrino interaction topology in SBND is charged-current quasi-elastic muon neutrino-argon interactions, where the final state consists of a muon and a proton. Here, muons often travel long distances, sometimes exiting the detector before stopping. This loss of information creates a challenge for accurate energy estimation. There have been efforts in the MicroBooNE and ICARUS collaborations to improve energy estimation using a phenomenon known as Multiple Coulomb Scattering (MCS), which describes the jagged path taken by muons through a detector due to continuous Coulomb interactions with argon atoms. Building on these efforts, my project aims to improve an MCS-based approach to estimating the energies of exiting muons in SBND.

Puig, Xilonem Angeles [Mt. Holyoke Coll.; Fermilab

PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval

Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple scattering further complicates interpretation. These effects degrade resolution, particularly in conventional reconstruction algorithms, which assume linearity. Particle averaging can reduce such issues but is unsuitable for heterogeneous or dynamic samples ubiquitous in biology, chemistry, and materials sciences. Here, we develop a phase retrieval-based cryo-ET method, PhaseT3M. We experimentally demonstrate its application to an approximately 7 nm Co3O4 nanoparticle on an approximately 30 nm carbon substrate, achieving a maximum resolution of 1.6 Å, surpassing conventional limits using standard cryo-TEM equipment. PhaseT3M uses a multislice model for multiple scattering and Bayesian optimization for alignment and computational aberration correction, with a positivity constraint to recover ‘missing wedge’ information. Applied directly to biological particles, it enhances reconstruction quality and reduces artifacts, establishing a standard for routine 3D imaging with phase contrast.

Biophysics

Satellite Optical Remote Sensing of Clouds and Aerosols: From Particle Single-Scattering and Gaseous Absorption Through Radiative Transfer to Retrieval Products

Clouds and aerosols are fundamental regulators of Earth’s radiation budget and climate system, influencing both solar and terrestrial radiation through scattering, absorption, and emission processes. Accurate characterization of their physical and radiative properties from space requires a rigorous understanding of particle single-scattering, gaseous absorption, and radiative transfer in the atmosphere, as well as reliable inversion methods. This review synthesizes the physical foundations and algorithmic implementations of satellite-based passive optical remote sensing of clouds and aerosols, spanning the ultraviolet to thermal infrared spectral range. Beginning with electromagnetic scattering theory and state-of-the-art methods for computing single-scattering by nonspherical particles and computationally efficient methods for accounting for atmospheric absorption, we discuss the radiative transfer framework underpinning cloud and aerosol retrievals. The connection between single-scattering and multiple-scattering is rigorously formulated. We then summarize operational and research-grade retrieval techniques, including cloud masking and thermodynamic phase determination, CO₂ slicing for cloud-top pressure, the Nakajima-King shortwave bi-spectral, and infrared split-window approaches for cloud optical thickness and effective particle size, inversion algorithms for determining aerosol properties from multi-spectral and/or multi-angle radiometric and polarimetric measurements, and active-passive sensing synergy. Examples of the global cloud and aerosol climatologies are illustrated using observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Multi-angle Imaging SpectroRadiometer (MISR). Furthermore, the unique strengths of active remote sensing techniques based on spaceborne lidar observations are briefly elaborated in the context of studying ice clouds composed of randomly and horizontally oriented ice crystals, which is a significant challenge for conventional passive remote sensing techniques. By connecting physical theory to practical retrievals, this review highlights both the maturity of current methodologies and the remaining challenges in reducing uncertainties in particle morphology, vertical structure, absorption, and aerosol-cloud interactions. Furthermore, the impact of artificial intelligence (AI) on atmospheric remote sensing is briefly addressed.

Aerosols

Flavor, transverse momentum, and azimuthal dependence of charged pion multiplicities in semi-inclusive deep-inelastic scattering with 10.6 GeV electrons

Measurements of semi-inclusive deep-inelastic scattering multiplicities for 𝜋 + and 𝜋 − from proton and deuteron targets are reported on a grid of hadron kinematic variables 𝑧, 𝑃 𝑇 , and 𝜙* for leptonic kinematic variables in the range 0.3<𝑥<0.6 and 3<𝑄 2 <5GeV 2 . Data were acquired in 2018 and 2019 at Jefferson Lab Hall C with a 10.6 GeV electron beam impinging on 10-cm-long liquid hydrogen and deuterium targets. Scattered electrons and charged pions were detected in the High Momentum Spectrometer and Super High Momentum Spectrometer, respectively. The multiplicities were fitted for each bin in (𝑥,𝑄 2 ,𝑧,𝑃𝑡) to extract the 𝜙*—independent 𝑀 0 and the azimuthal modulations ⟨cos⁡(𝜙*)⟩ and ⟨cos⁡(2⁢𝜙*)⟩. The 𝑃𝑡 dependence of the 𝑀 0 results was found to be remarkably consistent for the four cases studied: 𝑒⁢𝑝→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑝→𝑒⁢𝜋 − ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 − ⁢𝑋 over the range 0GeV<𝑃 𝑡 <0.4GeV, as were the multiplicities evaluated near 𝜙*=180∘ over the extended range 0GeV<𝑃 𝑡 <0.7GeV. The Gaussian widths of the 𝑃 𝑡 dependence exhibit a quadratic increase with 𝑧. The cos⁡(𝜙*) modulations were found to be consistent with zero for 𝜋 + , in agreement with previous world data, while the 𝜋 − moments were, in many cases, significantly greater than zero. The cos⁡(2⁢𝜙*) modulations were found to be consistent with zero. The higher statistical precision of this dataset of about 20 000 individual multiplicity values, compared with previously published data, should allow improved determinations of quark transverse momentum distributions and higher twist contributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES

Absence of magnetic order in epitaxial RuO 2 revealed by x-ray linear dichroism

Recently the topic of altermagnetism has attracted tremendous attention, and RuO 2 has been demonstrated to be one of the most promising altermagnetic candidates. However, disputes still remain on the existence of magnetic order in RuO 2 . Here in this work, we employ x-ray linear dichroism (XLD), a widely utilized technique for characterizing antiferromagnets, in conjunction with photoemission electron microscopy and multiple scattering calculation to provide clear evidence of the absence of magnetic order in epitaxial RuO 2 films. The observed XLD signal is nearly invariant with temperature and independent of cooling-field direction, in stark contrast to the substantial magnetic-order-related XLD signal predicted by multiple scattering calculation. This finding strongly suggests a nonmagnetic origin for RuO 2 . Furthermore, we observed significantly distinct XLD signals at the Ru M 3 and O K edges in RuO 2 films grown on TiO 2 substrate with different surface orientations, which can be attributed to the low-symmetry crystal field. In conclusion, these results unequivocally demonstrate the absence of magnetic order in RuO 2 and establish XLD measurement as a robust technique for probing the low-symmetry magnetic materials.

Wang, Siyu [University of Science and Technology o

CuXASNet: Rapid and accurate prediction of copper L-edge x-ray absorption spectra using machine learning

In this work, we have developed CuXASNet, a dense neural network that predicts simulated Cu -edge x-ray absorption spectra (XAS) from atomic structures. Featurization of the Cu local environment is performed using a component of M3GNet, a graph neural network developed for predicting the potential energy surface. CuXASNet is trained on simulated spectra from FEFF9 at the multiple scattering level of theory, and can predict the and edges for Cu sites to quantitative accuracy. To validate our approach, we compare 14 experimental spectra extracted from the literature with the predictions of CuXASNet. The agreement of CuXASNet with experiments is shown by an average mean absolute error of 0.125 and an average Spearman's correlation coefficient of 0.891, which is comparable to FEFF9's values of 0.131 and 0.898 for the same metrics. As such, CuXASNet can rapidly predict a large number of -edge XAS spectra at the same accuracy as FEFF9 simulations. This can be used as a drop-in replacement for multiple scattering codes for fast screening of candidate atomic structure models of a measured system. This model establishes a general framework for Cu XAS prediction, and can be extended to more computationally expensive levels of theory and to other transition metal edges.

36 MATERIALS SCIENCE

Combining geometric-optical and spectral invariants theories for modeling canopy fluorescence anisotropy

The spectral invariants theory ( p -theory) has received much attention in the field of quantitative remote sensing over the past few decades and has been adopted for modeling of canopy solar-induced chlorophyll fluorescence (SIF). However, the spectral invariant properties (SIP) in simple analytical formulae have not been applied for modeling canopy fluorescence anisotropy primarily because they are parameterized in terms of leaf total scattering, which precludes the differentiation between forward and backward leaf SIF emissions. In this study, we have developed the canopy-SIP SIF model by combining geometric-optical (GO) theory to account for asymmetric leaf SIF forward and backward emissions at the first-order scattering and by modeling multiple scattering based on the p-theory, thus avoiding the dependence on radiative transfer models. The applicability of the model simulations especially over 3D heterogeneous canopies was improved by incorporating canopy structure through multi-angular clumping index, and by modeling single scattering from the four components of the scene in view according to the GO approach. The results show good consistency with both the state-of-the-art SIF models and multi-angular field SIF observations over grass and chickpea canopies. Further, the coefficient of determination (R²) between the simulated SIF and field measurements was 0.75 (red) and 0.74 (far-red) for chickpea, and 0.65 (both red and far-red) for grass. The average relative error was approximately 3% for 1D homogeneous scenes when comparing the canopy-SIP SIF model simulations to the SCOPE model simulations, and around 4% for the 3D heterogeneous scene when comparing to the LESS model simulations. The results indicate that the proposed approach for separating asymmetric leaf SIF emissions is a robust way to keep a balance between satisfactory simulation accuracy and efficiency. Model simulations suggest that neglecting the leaf SIF asymmetry can lead to an underestimation of canopy red SIF by 6.3% to 42.6% for various leaf biochemical and canopy structural parameters. This study presents a simple but efficient analytical approach for canopy fluorescence modeling, with potential for large-scale canopy fluorescence simulations.

3D heterogeneous structure

Studies of optical and chemical properties of aged and fresh biomass burning absorbing aerosols for climate models

Particulate emissions from burning fuels from sub-Saharan Africa is currently poorly characterized. With increasing population and industrialization, emissions are expected to grow. Optical methods for measuring light absorption in the ultraviolet (UV) and visible (vis) regions of the spectrum are crucial for understanding the optical properties of BB aerosols (Bond and Bergstrom, 2006; Lack and Cappa, 2010; Moschos et al., 2021). One such instrument is the dual-spot AE33 model aethalometer is a common filter-based instrument that can be used to measure aerosol absorption properties (Hansen et al., 1984). This instrument has many figures of merit; however, the method's limitations include potential biases from scattering within the filter material, multiple scattering effects of the particles, filter loading (i.e. particle shadowing), and the need for wavelength-specific correction factors (Cλ), which depend on accurate intercomparison with other in situ techniques (Bond et al., 1999; Collaud Coen et al., 2010). This work aims to: 1. Optically characterize BB aerosol generated from African fuel 2. Correct the aethalometer at multiple wavelengths 3. Parametrize these correction factors. 4. Combusting the same fuels with two difference tube furnace systems assess the general applicability of this flexible means of producing BB aerosol. This was accomplished by conducting laboratory studies at Los Alamos National Laboratory (LANL) and North Carolina A&T State University (NCA&T), where aethalometer measurements were compared to in situ optical measurements. Mass cross sections of BB aerosol from these under-studied fuels will be determined along with their wavelength dependence.

09 BIOMASS FUELS