Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiphase segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Adaptive reference voltage generator for firing angle control of line-commutated inverters

A control system for a permanent-magnet motor driven by a multiphase line-commulated inverter is described. It is provided with integrators for integrating the back EMF of each phase of the motor for use in generating system control signals for an inverter gate logic using a sync and firing angle control generator connected to the outputs of the integrators. The firing angle control signals are produced by the control generator by means for combining 120 deg segments of the integrated back EMF signals symmetrical about their maxima into composite positive and negative waveforms, and means for sampling the maxima of each waveform every 120 deg. These samples are then used as positive and negative firing angle control signals. Whereby any change in amplitude of the integrated back EMF signals will not affect a change in the operating power factor of the motor and inverter.

Dolland, C. R.↗

Modeling Autogenous Pressurization and Draining of a Cryogenic Storage Tank in Normal Gravity

A two-phase CFD model for autogenous pressurization and draining of a cryogenic storage tank is presented using both the Sharp Interface and Volume-Of-Fluid (VOF) approaches for capturing the front and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. Both models are validated against data provided by the Cryogenic Propellant Storage and Transfer (CPST) Engineering Development Unit (EDU) experiment. The results of the autogenous pressurization are presented first, focusing on the phase change and turbulence effects on the tank pressure and temperature predictions. Both the Sharp Interface (SI-CFD) and VOF (VOF-CFD) multiphase models predict tank pressure during pressurization within 3% of the measured values. The sensitivity of key physical and numerical parameters of the problem are tested using the Sharp Interface model. Effects of the accommodation coefficient (AC), and the computational grid structure are studied. The second part of this paper is devoted to validating the SI-VOF model, with an enhanced capability of moving the liquid-vapor interface, against the draining segment of the EDU experiment. The VOF-CFD model was also used to simulate tank draining and its results were compared with the results of the Sharp Interface model with the moving interface. Both models predict tank pressure during draining within 3.5% of the measured values. Pressure decrease rate is underpredicted by both models during the first 100 seconds of draining but matches the experimental rate for the rest of the simulation.

Computational Fluid Dynamics↗

Modeling Autogenous Pressurization and Draining of a Cryogenic Storage Tank in Normal Gravity

A two-phase CFD model for autogenous pressurization and draining of a cryogenic storage tank is presented using both the Sharp Interface and Volume-Of-Fluid (VOF) approaches for capturing the front and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. Both models are validated against data provided by the Cryogenic Propellant Storage and Transfer (CPST) Engineering Development Unit (EDU) experiment1. The results of the autogenous pressurization are presented first, focusing on the phase change and turbulence effects on the tank pressure and temperature predictions. Both the Sharp Interface (SI-CFD) and VOF (VOF-CFD) multiphase models predict tank pressure during pressurization within 3% of the measured values. The sensitivity of key physical and numerical parameters of the problem are tested using the Sharp Interface model. Effects of the accommodation coefficient (AC), and the computational grid structure are studied. The second part of this paper is devoted to validating the SI-VOF model, with an enhanced capability of moving the liquid-vapor interface, against the draining segment of the EDU experiment. The VOF-CFD model was also used to simulate tank draining and its results were compared with the results of the Sharp Interface model with the moving interface. Both models predict tank pressure during draining within 3.5% of the measured values. Pressure decrease rate is underpredicted by both models during the first 100 seconds of draining but matches the experimental rate for the rest of the simulation.

Computational Fluid Dynamics↗

A Design Tool for Liquid Rocket Engine Injectors

A practical design tool for the analysis of flowfields near the injector face has been developed and used to analyze the Fastrac engine. The objective was to produce a computational design tool which was detailed enough to predict the interactive effects of injector element impingement angles and points and the momenta of the individual orifice flows. To obtain a model which could be used to simulate a significant number of individual orifices, a homogeneous computational fluid dynamics model was developed. To describe liquid and vapor sub- and super-critical flows, the model included thermal and caloric equations of state which were valid over a wide range of pressures and temperatures. A homogeneous model was constructed such that the local state of the flow was determined directly, i.e. the quality of the flow was calculated. Such a model does not identify drops or their distribution, but it does allow the flow along the injector face and into the acoustic cavity to be predicted. It also allows the film coolant flow to be accurately described. The initial evaluation of the injector code was made by simulating cold flow from an unlike injector element and from a like-on-like overlapping fan (LOL) injector element. The predicted mass flux distributions of these injector elements compared well to cold flow test results. These are the same cold flow tests which serve as the data base for the JANNAF performance prediction codes. The flux distributions 1 inch downstream of the injector face are very similar; the differences were somewhat larger at further distances from the faceplate. Since the cold flow testing did not achieve good mass balances when integrations across the entire fan were made, the CFD simulation appears to be reasonable alternative to future cold flow testing. To simulate the Fastrac, an RP-1/LOX combustion model must be chosen. This submodel must be relatively simple to accomplish three-dimensional, multiphase flow simulations. Single RP-1 pyrolysis and partial oxidation steps were chosen and the combustion was completed with the wet CO mechanism. Soot was also formed with a single global reaction. To validate the combustion submodel, global data from gas generator tests and from subscale motor test were used to predict qualitatively correct mean molecular weights, temperature, and soot levels. Because such tests do not provide general kinetics rates, the methodology is not necessarily appropriate for other than rocket type flows conditions. Soot predictions were made so that radiation heating to the motor walls can be made. These initial studies of the Fastrac were for a small region close to the injector face and chamber wall which included a segment of the acoustic cavity. The region analyzed includes 11 individual orifice holes to represent the LOL elements and the H2 film coolant holes. Typical results of this simulation are shown in Figure 1. At this point the only available test data to verify the predictions are temperatures measured in the acoustic cavity. These temperatures are in reasonable agreement at about 2000R (1111 K). Future work is expected to include improving the computational efficiency or the CFD model and/or using more computer capacity than the single Pentium PC with which these simulations were made.

Farmer, Richard C.↗