Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “moisture control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Isotherm Model for Moisture-Controlled CO 2 Sorption

Moisture-controlled sorption of CO 2 , the basis for moisture-swing CO 2 capture from air, is a novel phenomenon observed in strong-base anion exchange materials. Prior research has shown that Langmuir isotherms provide an approximate fit to moisture-controlled CO 2 sorption isotherm data. However, this fit still lacks a governing equation derived from an analytic model. As such, in this paper we derive an analytic form for an isotherm equation from a bottom-up approach, starting with a fundamental theory for an alkali liquid. In the range of interest relevant to CO 2 capture from air, an isotherm equation for an alkali liquid reduces to a simple analytic form with a single parameter, $K_{\text{eq}}$. In the limit $K_{\text{eq}} \gg 1$, a 2nd order approximation simplifies to a Langmuir isotherm that, however, deviates from experimental data. The isotherm theory for an alkali liquid has been generalized to a strong-base anion exchange material. In a strong-base anion exchange material, water concentration inside a sorbent, [H 2 O], is not large enough to be regarded as constant, which allows us to extend $K_{\text{eq}}$ to $K_{\text{eq(AEM)eff}} = K_{\text{eq(AEM)}} \times$ [H 2 O]$^{–n}$ according to the law of mass action. The final isotherm formula has been validated by experimental data from the literature. For a moisture-controlled CO 2 sorbent, $K_{\text{eq(AEM)eff}}$ varies significantly with moisture content of the sorbent. Depending on moisture level, the observed $K_{\text{eq(AEM)eff}}$ in a specific sorbent ranges from a few times to a few thousand times the value of $K_{\text{eq}}$ of a 2 mol L –1 alkali liquid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetic Model for Moisture-Controlled CO 2 Sorption

The understanding of the sorption/desorption kinetics is essential for practical applications of moisture-controlled CO 2 sorption. We introduce an analytic model of the kinetics of moisture-controlled CO 2 sorption and its interpretation in two limiting cases. In one case, chemical reaction kinetics on pore surfaces dominates, in the other case, diffusive transport through the sorbent defines the kinetics. Here, we show that reaction kinetics, which is dominant in the first case, can be expressed as a linear combination of 1st and 2nd order kinetics in agreement with the static isotherm equation derived and validated in a previous paper. The interior transport kinetics can be described by non-linear diffusion equations. By combining all carbon species into a single equation, we can eliminate — in certain limits — the source terms associated with chemical reactions. In this case, the governing equation is ∂θ/∂t = –∇ · (–D eff ∇ θ ). For a sorbent in a form of a flat sheet or a membrane, one can maintain the same functional form of a diffusion equation by introducing a generalized effective diffusivity D M that combines contributions from both surface chemical reaction kinetics and interior diffusive transport kinetics. Experimental data of transient CO 2 flux in a preconditioned commercial anion exchange membrane fit well to the 1st order model as long as very dry states are avoided, validating the theory. The observed DM for a preconditioned commercial anion exchange membrane ranges from 6.6× 10 -14 to 7.1× 10 -14 m 2 s -1 at 35°C. These small values compared to typical ionic diffusivities imply a very slow kinetics, which will be the largest issue that needs to be addressed for practical application. The collected transient CO 2 flux data are used to predict the magnitude of a continuous CO 2 pumping flux in an active membrane that transports CO 2 against a CO 2 concentration gradient. The pumped CO 2 flux is supported by water flux due to a water concentration gradient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upwind Moisture Controls on Interannual Variations of Precipitation and Vegetation in China's Drylands

Dryland precipitation depends on upwind and local moisture sources via moisture recycling. How upwind moisture variations affect interannual variations of downwind precipitation and vegetation in China's drylands remains unclear. We used high-resolution moisture tracking data sets and found terrestrial moisture (93%) was the dominant moisture source for China's drylands, especially from drylands themselves (46%). In most dryland grids, we observed strong correlations between precipitation and upwind moisture sources from 2003 to 2022 (median r = 0.55), with a more significant effect in drier areas. These demonstrated the upwind moisture control on interannual variations of dryland precipitation, in which internal moisture from drylands exceeds the influence of external terrestrial sources. The upwind moisture variations, especially the recycled moisture of drylands, propagate to influence downwind vegetation greenness in precipitation-sensitive dryland areas. Our findings revealed that upwind moisture variations induced by climate or land-cover changes have important implications for water and food security in China's drylands.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemically regenerable metabolic CO2 and moisture control system for an advanced EMU application

Regenerable CO2 and moisture removal techniques that reduce expendables and logistics requirements are needed to sustain people undertaking extravehicular activities for the Space Station. NASA has been investigating ways to advance the Electrochemically Regenerable CO2 and Moisture Absorption (ERCA) technology to replace the nonregenerable solid lithium hydroxide absorber for the advanced Portable Life Support System (PLSS). The ERCA technology, due to its use of liquid absorbent, has the ability to effectively satisfy the high metabolic CO2 and moisture removal requirements of PLSS applications. This paper defines the ERCA technology concept and its advantages for the PLSS application, reviews breadboard and subscale testdata and presents the results of design concepts for a prototype Absorber Module of improved performance and the physical characteristics of the projected flight hardware.

Lee, M. C.↗

Temperature and Snow-Mediated Moisture Controls of Summer Photosynthetic Activity in Northern Terrestrial Ecosystems Between 1982 and 2011

Recent warming has stimulated the productivity of boreal and Arctic vegetation by reducing temperature limitations. However, several studies have hypothesized that warming may have also increased moisture limitations because of intensified summer drought severity. Establishing the connections between warming and drought stress has been difficult because soil moisture observations are scarce. Here we use recently developed gridded datasets of moisture variability to investigate the links between warming and changes in available soil moisture and summer vegetation photosynthetic activity at northern latitudes (greater than 45N) based on the Normalized Difference Vegetation Index (NDVI) since 1982. Moisture and temperature exert a significant influence on the inter-annual variability of summer NDVI over about 29% (mean r(sup 2) = 0.29 +/ 0.16) and 43% (mean r(sup 2 = 0.25 +/- 0.12) of the northern vegetated land, respectively. Rapid summer warming since the late 1980s (approximately 0.7deg C) has increased evapotranspiration demand and consequently summer drought severity, but contrary to earlier suggestions it has not changed the dominant climate controls of NDVI over time. Furthermore, changes in snow dynamics (accumulation and melting) appear to be more important than increased evaporative demand in controlling changes in summer soil moisture availability and NDVI in moisture-sensitive regions of the boreal forest. In boreal North America, forest NDVI declines are more consistent with reduced snowpack rather than with temperature-induced increases in evaporative demand as suggested in earlier studies. Moreover, summer NDVI variability over about 28% of the northern vegetated land is not significantly associated with moisture or temperature variability, yet most of this land shows increasing NDVI trends. These results suggest that changes in snow accumulation and melt, together with other possibly non-climatic factors are likely to play a significant role in modulating regional ecosystem responses to the projected warming and increase in evapotranspiration demand during the coming decades.

Snowpack↗

Soil Moisture Controls on Rainfall and Temperature Variability: A Modeler Searches Through Observational Data

The degree to which atmospheric processes respond to variations in soil moisture - a potentially important but largely untapped element of subseasonal to seasonal prediction - can be determined easily and directly for an atmospheric model but cannot be determined directly for nature through an analysis of observations. In atmospheric models) directions of causality can be artificially manipulated; we can avoid difficulties associated with the fact that atmospheric variations have a much larger impact on land state variations than vice-versa. In nature) on the other hand) the dominant direction of causality (the atmosphere forcing the ground) cannot be artificially "turned off") and the statistics associated with this dominant direction overwhelm those of the feedback signal. Observational data) however) do allow a number of indirect measures of landatmosphere feedback. This seminar reports on a series of joint analyses of observational and model data designed to illuminate the degree of land-atmosphere feedback present in the real world. The indirect measures do in fact suggest that feedback in nature, though small) is significant - enough to warrant the development of realistic land initialization strategies for subseasonal and seasonal forecasts.

Koster, Randal↗

Hygrothermal analyses of the moisture control and energy efficiency potential of an adaptive water-resistive barrier for building envelopes

A water-resistive barrier (WRB) is a material installed on the exterior side of the sheathing to prevent water intrusion so that building components are not damaged by moisture. A membrane that can change its water vapor permeability between two states to control water vapor transport into and out of residential and commercial building wall systems is being developed. This simulation study assesses if this membrane used as a WRB reduces moisture levels and mold growth risk in exterior walls and building energy consumption. The developed membrane may require modifications to fully function as a WRB in contact with liquid water. Hygrothermal component simulations were conducted for different climate zones, different wall assemblies, different switching points and permeabilities to identify the most beneficial application cases and their required perm range and switching control. The study details the required simulation settings and suggests that the switchable membrane can reduce the water content in the sheathing and reduce the mold growth risk in the cavity in all climate zones. The effect on energy consumption of the switchable membrane is not significant. The study also includes recommendations on how to model the material characteristics of a switchable membrane and recommendations on practical applications for the switchable membrane.

42 ENGINEERING↗

Re-evaluation of Moisture Controls During ARIES Oxide Processing, Packaging and Characterization

DOE-STD-3013 [1] requires limiting the relative humidity (RH) in the glovebox during processing of the oxide product for specific types of plutonium oxides. This requirement is mandated in order to limit corrosion of the stainless steel containers by deliquescence of chloride salts if present in the PuO2. DOE-STD-3013 also specifies the need to limit and monitor internal pressure buildup in the 3013 containers due to the potential for the generation of free H2 and O2 gas from the radiolysis of surfaceadsorbed water. DOE-STD-3013 requires that the oxide sample taken for moisture content verification be representative of the stabilized material in the 3013 container. This is accomplished by either limiting the time between sampling and packaging, or by control of the glovebox relative humidity (%RH). This requirement ensures that the sample is not only representative, but also conservative from the standpoint of moisture content.

36 MATERIALS SCIENCE↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Durable Attics

Learn about controlling moisture and ventilation in your attic, as well as the steps to create a durable attic. This fact sheet from Energy Saver includes information on why moisture control in attics is important and the strategies you can use to control moisture and ventilation in your attic.

attic, moisture, ventilation, Energy Saver↗

Integrated model of G189A and Aspen-plus for the transient modeling of extravehicular activity atmospheric control systems

A computerized modeling tool, under development for the transient modeling of an extravehicular activity atmospheric control subsystem is described. This subsystem includes the astronaut, temperature control, moisture control, CO2 removal, and oxygen make-up components. Trade studies evaluating competing components and subsystems to guide the selection and development of hardware for lunar and Martian missions will use this modeling tool. The integrated modeling tool uses the Advanced System for Process Engineering (ASPEN) to accomplish pseudosteady-state simulations, and the general environmental thermal control and life support program (G189A) to manage overall control of the run and transient input output, as well as transient modeling computations and database functions. Flow charts and flow diagrams are included.

Kolodney, Matthew↗

Statistical Quality Control of Moisture Data in GEOS DAS

A new statistical quality control algorithm was recently implemented in the Goddard Earth Observing System Data Assimilation System (GEOS DAS). The final step in the algorithm consists of an adaptive buddy check that either accepts or rejects outlier observations based on a local statistical analysis of nearby data. A basic assumption in any such test is that the observed field is spatially coherent, in the sense that nearby data can be expected to confirm each other. However, the buddy check resulted in excessive rejection of moisture data, especially during the Northern Hemisphere summer. The analysis moisture variable in GEOS DAS is water vapor mixing ratio. Observational evidence shows that the distribution of mixing ratio errors is far from normal. Furthermore, spatial correlations among mixing ratio errors are highly anisotropic and difficult to identify. Both factors contribute to the poor performance of the statistical quality control algorithm. To alleviate the problem, we applied the buddy check to relative humidity data instead. This variable explicitly depends on temperature and therefore exhibits a much greater spatial coherence. As a result, reject rates of moisture data are much more reasonable and homogeneous in time and space.

Dee, D. P.↗

Feed-Back Moisture Sensor Control for the Delivery of Water to Plants Cultivated in Space

The development of a spaceflight-rated Porous Tube Insert Module (PTIM) nutrient delivery tray has facilitated a series of studies evaluating various aspects of water and nutrient delivery to plants as they would be cultivated in space. We report here on our first experiment using the PTIM with a software-driven feedback moisture sensor control strategy for maintaining root zone wetness level set-points. One-day-old wheat seedlings (Tritium aestivum cv Apogee; N=15) were inserted into each of three Substrate Compartments (SCs) pre-packed with 0.25-1 . mm Profile(TradeMark) substrate and maintained at root zone relative water content levels of 70, 80 and 90%. The SCs contained a bottom-situated porous tube around which a capillary mat was wrapped. Three Porous Tubes. were planted using similar protocols (but without the substrate) and also maintained at these three moisture level set-points. Half-strength modified Hoagland's nutrient solution was used to supply water and nutrients. Results on hardware performance, water usage rates and wheat developmental differences between the different experimental treatments are presented.

Levine, Howard G.↗

Technology Solutions Case Study: Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier

In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the Consortium of Advanced Residential Buildings (CARB) team monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74°-80°F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

air conditioning↗

Barriers to Developing Sustainable Supply of Lignocellulosic Feedstock for Production of Biofuels

Thirteen unique storage conditions of baled corn stover biomass were studied to examine the impact of bale type, baling technique, and storage practice on moisture control and product degradation over time. Square bales were found to outperform round bales in terms of moisture regulation and physical stability across all treatment types and at all sampling times. Within square bales, the control of moisture content in short term storage (3 months) is comparable between tarped and untarped stacks. In long term storage (9 months), bale wrapping outperforms both tarped and open stacks. In terms of overall moisture control, stack tarping allows moisture to leave initially wet bales, but allows dry bales to gain large amounts of moisture over time. Initial moisture content was found to drive self-heating and depend heavily on storage practice. While differences in dry matter loss over time are unclear, bale stability was lowest in the untarped stack, moderate in tarped stacks, and greatest in wrapped stacks. Overall, bale storage has been shown to be a dynamic system which requires special judgment to be made depending on the state of inbound material and the desired storage duration.

Feedstock↗