Miniaturized Aerosol Observing System (AOS) Miniaturized Scanning Electrical Mobility Sizer (a1-level)
Miniaturized Aerosol Observing System (AOS) Miniaturized Scanning Electrical Mobility Sizer
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Miniaturized Aerosol Observing System (AOS) Miniaturized Scanning Electrical Mobility Sizer
Numerous separate effects irradiations of miniature nuclear fuel specimens have been conducted in the High Flux Isotope Reactor (HFIR) under the experimental platform designated as MiniFuel. MiniFuel is a static irradiation capability in which microstructural evolution and fuel performance phenomena are observed during postirradiation examination thereby offering a snapshot of the terminal fuel characteristics. This approach inherently requires fielding an irradiation where the experimental conditions are determined using predictive models and the pertinent outcomes are measured at the end of the test. Static irradiations can provide useful insights to the relationships between fuel performance and the pivotal irradiation conditions, namely temperature and burnup, but the ability to monitor fuel performance in situ would further support fuel development and qualification. To this end, an instrumented experiment design is being developed at Oak Ridge National Laboratory to capture thermal conductivity degradation and fission gas release during HFIR irradiation. These phenomena will be monitored using unique capsule designs that each target a different phenomenon. This paper details the thermal conductivity capsule (TCC) design and its expected performance envelope as determined using computer models. Each TCC will contain a miniature UO2 disc specimen (~0.5 mm thick × 5 mm diameter) sandwiched between metallic slugs with embedded thermocouples. The coupling of in situ temperature measurements, known thermal conductivity of the metallic components, and heat generation rates computed using high-fidelity neutronics models make the thermal conductivity measurement possible. This paper describes the reactor physics and heat transfer models used to predict the capsule’s performance and the methodology for calculating the fuel specimen’s thermal conductivity from the thermocouple measurements.
The miniaturized scanning electrical mobility sizer (mSEMS), as shown in Figure 1, represents an advancement in particle size measurement technology. Designed for portability, this compact instrument is engineered to deliver precise and accurate assessments of particle size distributions. The mSEMS uses scanning electrical mobility sizing technology to analyze aerosol particles within a specified size range. Its miniaturized design does not compromise on performance, making it ideal for a myriad of applications across laboratory research, environmental monitoring, and industrial settings. The user friendly interface simplifies operation, while the instrument's robust construction ensures reliability in various conditions. Researchers and professionals can rely on the mSEMS to provide invaluable insights into aerosol dynamics, contributing to advancements in aerosol science.
A typical structural health monitoring technique involves measuring the vibrational characteristics of components or systems to detect signs of degradation or damage. Many industrial applications require engineered systems to safely operate under extreme, high-temperature environments that pose challenges not only to materials but also to sensors that would be used for structural health monitoring. Here, in this study, miniaturized optical Fabry-Perot cavities (FPCs) were developed and tested as a means of measuring the resonant frequencies of metal components that are most relevant to extreme-environment applications. Two of the three candidate FPC designs tested up to 800 ° C provided accurate measurements (validated by theoretical models and laser Doppler vibrometry) of the fundamental vibrational mode of the specimen to which each was bonded, although both sensors failed during thermal cycling. An analysis of the reflected optical spectrum from the FPC and X-ray computed tomography revealed two opportunities to improve the sensor reliability. First, the Cu optical fiber coating that was used could either be replaced with a more oxidation-resistant material or protected with commercially available films. Second, the adhesives used to bond the fibers to metal capillaries and establish the FPC could be replaced with a more robust solution, although the Resbond 907TS adhesive appeared to outperform Resbond 907.
Here, this article presents an innovative, fully additive manufactured approach to millimeter-wave multilayer circuits. An aerosol jet printer is used to fabricate a multilayer stepped-impedance low-pass filter. By leveraging the second layer for miniaturization, we achieve a more compact design. By precisely controlling conductor separation and utilizing 3-D printing technology, we were able to optimize the width of the high- and low-impedance segments for optimal filter performance. Two filter types were successfully fabricated: a low-pass microstrip filter and a low-pass stripline filter, both with a cutoff frequency near 29 GHz and exhibiting acceptable stopband attenuation. The stripline configuration allows for a 36% decrease in the stripline waveguide conductor area while achieving a great passband insertion loss of just 0.62 dB, enabled by aerosol jet printing (AJP). The line loss of both designs was characterized using a microstrip through line and a stripline through line. Both designs demonstrated low overall loss, with the microstrip line exhibiting a loss of 0.26 dB/mm and the stripline having a loss of 0.37 dB/mm at 29 GHz. This work demonstrates a multilayer integration solution and offers an advantage in reducing the size of RF circuits such as filter banks for next-generation integrated RF front ends.
Redox flow batteries are a promising technology for grid-scale energy storage. The aqueous organic redox flow battery is of particular interest for its potentially low material cost and sustainability. Developing novel organic active material for flow battery electrolytes typically entails molecular engineering toward desired properties, necessitating organic synthesis. In a research laboratory setting, the synthesis of specifically designed organic molecules featuring targeted functional groups is time and resources intensive. In the past, synthesizing materials required for battery testing has often required gram-scale production, presenting considerable constraints on the pace of novel organic material discovery. In this report, we introduce a miniaturized cell design that mandates only milligram-scale material synthesis while yielding testing outcomes equivalent or superior to those reported with other commercially available or homemade flow cells in the literature. The test results under various pH conditions validate the scale-down strategy to accelerate the flow battery material discovery and development using the newly designed mini cell. This approach offers researchers an efficient means to notably reduce the time and resources required to develop novel materials for flow batteries.
Sustainably grown biomass is a promising alternative to produce fuels and chemicals and reduce the dependency on fossil energy sources. However, the efficient conversion of lignocellulosic biomass into biofuels and bioproducts often requires extensive testing of components and reaction conditions used in the pretreatment, saccharification, and bioconversion steps. This restriction can result in a significant and unwieldy number of combinations of biomass types, solvents, microbial strains, and operational parameters that need to be characterized, turning these efforts into a daunting and time-consuming task. Here we developed a high-throughput feedstocks-to-fuels screening platform to address these challenges. The result is a miniaturized semi-automated platform that leverages the capabilities of a solid handling robot, a liquid handling robot, analytical instruments, and a centralized data repository, adapted to operate as an ionic-liquid-based biomass conversion pipeline. The pipeline was tested by using sorghum as feedstock, the biocompatible ionic liquid cholinium phosphate as pretreatment solvent, a “one-pot” process configuration that does not require ionic liquid removal after pretreatment, and an engineered strain of the yeast Rhodosporidium toruloides that produces the jet-fuel precursor bisabolene as a conversion microbe. By the simultaneous processing of 48 samples, we show that this configuration and reaction conditions result in sugar yields (~70%) and bisabolene titers (~1500 mg/L) that are comparable to the efficiencies observed at larger scales but require only a fraction of the time. We expect that this Feedstocks-to-Fuels pipeline will become an effective tool to screen thousands of bioenergy crop and feedstock samples and assist process optimization efforts and the development of predictive deconstruction approaches.
Miniature disc samples pose challenging measuring conditions for laser flash analysis. With reductions in signal from lower radiosity and lower half-rise times from low thicknesses, optimal selections of coatings and laser parameters are critical in a successful measurement. This report explains the methodology in successfully measuring two different material types—metals and ceramics—in proper coating selection, laser parameters, and post analysis for each material, as well as applying it to un-irradiated uranium samples of each type (U-metal, UO 2 ). This was done through a combination of analysis techniques combining automatic commercial methods (Neztech) and manual methods for correcting laser pulse impact aberrations.
Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.
In this paper, we demonstrate a method of measuring the flexural elastic modulus of ceramics at an intermediate (~millimeter) scale at high temperatures. We used a picosecond laser to precisely cut microbeams from the location of interest in a bulk ceramic. They had a cross-section of approximately 100 μm × 300 μm and a length of ~1 cm. They were then tested in a thermal mechanical analyzer at room temperature, 500 °C, 800 °C, and 1100 °C using the four-point flexural testing method. We compared the elastic moduli of high-purity Al2O3 and AlN measured by our method with the reported values in the literature and found that the difference was less than 5% for both materials. This paper provides a new and accurate method of characterizing the high-temperature elastic modulus of miniature samples extracted from representative/selected areas of bulk materials.
Miniaturized Aerosol Observing System (AOS): Optical Particle Counter
Miniaturized Aerosol Observing System (AOS): Optical Particle Counter
Summary: This poster outlines a new small punch creep test (SPCT) for examining the mechanical properties of post surveillance test specimens. A surveillance test article was previously designed to study the effects of Molten-Salt conditions on the structural materials in the reactor. To better understand the post-test mechanical properties of the specimen, a miniature SPCT is proposed. The principle, testing standards and challenges of the method is introduced in the poster. An initial design of the testing apparatus is shown, and an experiment plan is outlined.
Here, this work reports on the design and performance of a jet pump system to pump slurries. The jet pump uses a high-velocity water jet to entrain and pump the slurry. This pumping action requires no valves and does not use moving solid parts. Hence, the system can be readily sealed, and the pumping action creates no observable mechanical damage to slurry particles. We tested carbon black beads suspended in water at concentrations of 0.0, 0.2, and 2.0 wt% at primary jet flow rates of 50 and 100 mL/min. Our measurements show an approximately linear decrease in entrainment ratio (slurry-to-jet flow rate) and absolute slurry flow rate with increasing adverse (load) pressure difference. The entrainment ratio is a strong function of the absolute jet flow rate. Pump performance was insensitive to slurry composition. Micron-resolution particle image velocimetry (micro-PIV) revealed qualitative changes in the pump’s internal flow due to changes in absolute jet flow rate, including evidence of the suppression of a vortex at higher flow rates. These findings establish key operational parameters for the jet pump and highlight its potential in a variety of slurry flow pumping applications. The pump is particularly suited for flow electrode slurries (e.g. as used for energy storage and water treatment) as it maintains particle integrity and can be used with standard tubing, tube fittings, and sealing methods.
Microbial and viral co-evolution has created immunity mechanisms involving oligonucleotide signalling that share mechanistic features with human antiviral systems1. In these pathways, including cyclic oligonucleotide-based antiphage signalling systems (CBASSs) and type III CRISPR systems in bacteria and cyclic GMP–AMP synthase–stimulator of interferon genes (cGAS–STING) in humans, oligonucleotide synthesis occurs upon detection of virus or foreign genetic material in the cell, triggering the antiviral response2, 3–4. Here, in an unexpected inversion of this process, we show that the CRISPR-related enzyme mCpol synthesizes cyclic oligonucleotides constitutively as part of an active mechanism that represses a toxic effector. Cell-based experiments demonstrated that the absence or loss of mCpol-produced cyclic oligonucleotides triggers cell death, preventing the spread of viruses that attempt immune evasion by depleting host cyclic nucleotides. Structural and mechanistic investigation revealed mCpol to be a di-adenylate cyclase whose product, c-di-AMP, prevents toxic oligomerization of the effector protein 2TMβ. Analysis of cells by fluorescence microscopy showed that lack of mCpol allows 2TMβ-mediated cell death due to inner membrane collapse. These findings unveil a powerful defence strategy against virus-mediated immune suppression, expanding our understanding of the role of oligonucleotides in immunity.
The diamond anvil cell (DAC) has been widely used in high-pressure research. Despite significant progress over the past five decades, the opposed anvil geometry in the DAC inevitably leads to a disk-shaped sample configuration at high pressure. This intrinsic limitation is largely responsible for the large pressure and temperature gradients in the DAC, which often compromise precise experiments and their characterizations. Here, we designed and fabricated a multi-axis diamond anvil cell (MDAC) by adopting the concept of a multi-anvil apparatus but using single crystal diamonds as the anvil material. Preliminary data show that the MDAC can generate extreme pressure conditions above 100 GPa. The advantages of the MDAC over a traditional opposed anvil DAC include thicker, voluminous samples, quasi-hydrostatic, or designed deviatoric stress conditions, and multidirectional access windows for optical applications and x-ray probes. In this article, we present the design and performance of a prototype MDAC, as well as the application prospects in high-pressure research.
94th Shock & Vibration Symposium, Dallas TX
Explore the source record for details and available documents.