Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “milford valley”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Formation of a Large Cold Groundwater Mantle Helium Anomaly and High Temperature Geothermal Resources in Response to Bimodal Magmatism Near Roosevelt Hot Springs and Utah FORGE, Milford Valley, Southwest Utah

Abstract A large mantle helium anomaly and separate domains of high heat flow are the predominant manifestations of bimodal magmatic activity in the Milford valley. The mantle helium anomaly (1.9–2.6 R/Ra) covers 270 km 2 and is subdivided into two separated domains: a cold shallow groundwater regime and high temperature hydrothermal activity. The zone of anomalous heat flow covers >100 km 2 and is also subdivided into two adjacent domains, comprising hydrothermal activity at Roosevelt Hot Springs (RHS) (3–7 W/m 2 ) and conductive heat flow (100–180 mW/m 2 ). While the transfer of heat and mantle helium at RHS are coupled, heat and helium transfer are decoupled in the adjacent cold groundwater regime to the west. Both the mantle helium and geothermal anomalies are attributed to recent mafic‐felsic magmatic intrusions of >400 km 3 , however, the absence of volcanic eruptions <500,000 years indicates magmas stall before rising to shallow crustal level <10 km depth. Deep level magmatism produces a felsic composition melt, which is inferred to be responsible for the widespread and near uniform range of diluted mantle helium values. A thick and impermeable mass of crystalline granitic basement rock at the mid‐crustal level divides the ascent of mantle helium into separate flow paths. It may also impede the rise of buoyant magma trapping thermal energy that facilitates partial melting, slow cooling, and development of a thick thermal aureole. Partitioning of convective and conductive thermal regimes and independent flow paths supplying deeply derived helium characterize the development of a large long‐lived magma‐related geothermal system.

Geochemistry & Geophysics↗

Utah FORGE: Geochemical Data for Cold Groundwaters and Produced Geothermal Fluids

Geochemical data for cold groundwaters and produced geothermal fluids around the Utah FORGE site. The data is compiled into four tables in the attached Excel File. Table 1 is a compilation of compositions (anions, cations, weak acids, oxygen, hydrogen, and carbon isotopes) for cold groundwaters and produced geothermal waters in the Milford valley, Utah. Table 2 is a compilation of noble gas (He, Ne, Ar) and He and Ne isotopic compositions for cold groundwaters and produced geothermal waters in the Milford valley, Utah. Table 3 provides values for calculated advective and diffusive fluxes of helium. Table 4 provides values of calculated subsurface stored heat between the Opal Mound fault and the Utah FORGE site, which are related to volumes of recently solidified magmatic heat sources.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Phase 3 Magnetotelluric (MT) Data

New high-quality tensor MT data at 122 sites, including the vertical magnetic field and utilizing ultra-remote referencing, have been acquired over the Utah FORGE project area. The results will be used to delineate the densities of faults and fractures in crystalline basement rocks, to define the heat sources, and to derive baseline 3D resistivity structure for later MT monitoring of temporal changes in resistivity structure following well stimulation in the EGS reservoir. There are three files here related to Utah FORGE magnetotelluric (MT) data acquisition and processing. The FORGE MT EDIs zip file contains the observed MT responses in industry-standard EDI format. For each site, there is an EDI response file that utilized a local independent reference for noise cancellation, and a file that utilized a distant reference cancelling noise associated with the DC transmission line of the Delta IPP passing down the west side of Milford Valley. These two site files could be merged as appropriate. The FORGE Model Cell Center file contains the model volume of the 3D Forge MT inversion for characterizing the resistivity structure in the project area. It was derived using finite element inversion methodology described in Wannamaker et al, in the attached FORGE Phase3 Geophysics paper, from the MT observation EDI files. It is ASCII format (.dat) and entries are defined at top of the file in a simple x-y-z-Rho listing in UTM coordinates. The element layers drape the topography so the Rho value layers are not purely horizontal slices. This greatly simplifies the listing.

15 GEOTHERMAL ENERGY↗

Analysis of the 2021 Milford, Utah earthquake swarm: Enhanced earthquake catalog and migration patterns

An earthquake swarm occurred in Spring 2021 in south-central Utah near the town of Milford. The University of Utah Seismograph Stations located 125 earthquakes between March 19 and May 10 with magnitudes ranging from 0.5 to 3.2. We implement a matched-filter technique in order to identify additional earthquakes that went undetected during the routine network location. The 125 network-located earthquakes are used as templates and are cross-correlated with continuous data for the dates Feb 17—June 10. This time period corresponds to approximately 1 month before the earthquake swarm began through 1 month after it ended. For the matched-filter analysis, we rely heavily on station FOR1, which is located within 5 km of most template events. Four other stations within 20–30 km of most template events provide a supplement to the closest station. The matched-filter implementation results in the detection of over 600 earthquakes in addition to the original 125 catalog events. This is one of the largest swarms ever recorded in Utah, and no previous large swarms have been recorded in this location. We use HypoDD to obtain relative double-difference locations of the catalog events. Both routine locations and HypoDD relocations of the catalog events suggest a fault dipping west beneath the mountain range, opposite of typical Basin and Range normal faults that dip beneath alluvial valleys. Moment tensors for the largest five events show normal faulting consistent with the west-dipping fault seen in the seismicity. Hydrothermal features in the area, including a geothermal power plant, suggest that fluids may be a contributing factor to the earthquake swarm triggering. We examine the role of fluids by exploring bounds on diffusion parameters and investigating spatial migration characteristics of the swarm seismicity. We conclude that this swarm is the result of heterogenous stress conditions in a prefractured region.

58 GEOSCIENCES↗