SEARCH · Engineering Papers
Results for “microneedle”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Production of Hydrogel Microneedles from Fish Scale Biopolymer
This work presents for the first time, a scalable, low cost method for producing hydrogel microneedles from fish scales derived biopolymer using a modified low temperature press method. The microneedles are made from cross-linked hydrolyzed collagen (HC). The suitability of the microneedles for drug loading were tested by loading with Ferrous gluconate. Force analysis carried out in compression mode showed that the microneedles could withstand up to 0.136 N per microneedle before fracture which is sufficient strength to pierce the skin. The cross-linked microneedles swelled to 340% of their original mass in PBS and within 24 h released 34.5% of the loaded drug, while the non cross-linked microneedles dissolved within minutes. Chemical testing of the released drug confirmed that the drug released retained its chemical structure by forming colored complex with acetylsalicylic acid and UV spectrometry was used to quantify the concentration released. FTIR analysis confirmed the modified structure of the polymer when cross-linked. This proposed method allows cross-linking at room temperature using a thermal press method which can be easily scaled up.
Handheld Microneedle-Based Electrolyte Sensing Platform.
Sandia National Laboratories will provide technical assistance, within time and budget, to Requester on testing and analyzing a microneedle-based electrolyte sensing platform. Hollow microneedles will be fabricated at Sandia and integrated with a fluidic chip using plastic laminate prototyping technology available at Sandia. In connection with commercial ion selective electrodes the sensing platform will be tested for detection of electrolytes (sodium and/or potassium) within physiological relevant concent ration ranges.
Microneedle-based electrical impedance sensor to monitor plant water status in real time
A sensor uses microneedle electrodes and multi-frequency electrical impedance spectroscopy to monitor plant water status in real time. The microneedle can be between 10 and 1000 microns in length, enabling precise placement in a variety of plant tissues. The impedance behavior can distinguish electrical properties and physiological functions of different plant tissue types. Therefore, impedance measurements can be used to monitor water stress to prevent irreversible damage to a plant and to enable improvement of plant biomass or fruit yield.
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Dermal interstitial fluid (ISF) is an underutilized information-rich biofluid potentially useful in health status monitoring applications whose contents remain challenging to characterize. Here, we present a facile microneedle approach for dermal ISF extraction with minimal pain and no blistering for human subjects and rats. Extracted ISF volumes were sufficient for determining transcriptome, and proteome signatures. We noted similar profiles in ISF, serum, and plasma samples, suggesting that ISF can be a proxy for direct blood sampling. Dynamic changes in RNA-seq were recorded in ISF from induced hypoxia conditions. Finally, we report the first isolation and characterization, to our knowledge, of exosomes from dermal ISF. The ISF exosome concentration is 12–13 times more enriched when compared to plasma and serum and represents a previously unexplored biofluid for exosome isolation. This minimally invasive extraction approach can enable mechanistic studies of ISF and demonstrates the potential of ISF for real-time health monitoring applications.
Biodegradable 3D printed polymer microneedles for transdermal drug delivery
DIY drug delivery: an easy way to get sharp break-away drug-loaded microneedles using an inexpensive off-the-shelf 3D printer.
Electrochemical aptamer-based sensors: leveraging the sensing platform for minimally-invasive microneedle measurements and fundamental exploration of sensor biofouling dynamics
The ability to track the concentrations of specific molecules in the body in real time would significantly improve our ability to study, monitor, and respond to diseases. To achieve this, we require sensors that can withstand the complex environment inside the body. Electrochemical aptamer-based sensors are particularly promising for in vivo sensing, as they are among the only generalizable sensing technologies that can achieve real-time molecular monitoring directly in blood and the living body. In this project, we first focused on extending the application space of aptamer sensors to support minimally-invasive wearable measurements. To achieve this, we developed individually-addressable sensors with commercial off-the-shelf microneedles. We demonstrated sensor function in buffer, blood, and porcine skin (a common proxy for human skin). In addition to the applied sensing project, we also worked to improve fundamental understanding of the aptamer sensing platform and how it responds to biomolecular interferents. Specifically, we explored the interfacial dynamics of biofouling – a process impacting sensors placed in complex fluids, such as blood.
Nitrogen-incorporated ultrananocrystalline diamond microneedle arrays for electrochemical biosensing
Not Available
Transdermal Microneedle Sensors to Monitor Human Health and Performance.
Abstract not provided.
Microneedle electrochemical aptamer-based sensors for real-time molecular measurements
Explore the source record for details and available documents.
Transdermal Electrochemical Sensing and Biosensing with Hollow Microneedles.
Abstract not provided.
On Body Transdermal Microneedle-Based Diagnostic Device to Measure Biomarker Signatures and Report on Human Performance.
Abstract not provided.
Microneedle arrays for biosensing and drug delivery
Methods, structures, and systems are disclosed for biosensing and drug delivery techniques. In one aspect, a^ device for detecting an analyte and/or releasing a biochemical into a biological fluid can include an array of hollowed needles, in which each needle includes a protruded needle structure including an exterior wall forming a hollow interior and an opening at a terminal end of the protruded needle structure that exposes the hollow interior, and a probe inside the exterior wall to interact with one or more chemical or biological substances that come in contact with the probe via the opening to produce a probe sensing signal, and an array of wires that are coupled to probes of the array of hollowed needles, respectively, each wire being electrically conductive to transmit the probe sensing signal produced by a respective probe.
Microneedle arrays for biosensing and drug delivery
Methods, structures, and systems are disclosed for biosensing and drug delivery techniques. In one aspect, a device for detecting an analyte and/or releasing a biochemical into a biological fluid can include an array of hollowed needles, in which each needle includes a protruded needle structure including an exterior wall forming a hollow interior and an opening at a terminal end of the protruded needle structure that exposes the hollow interior, and a probe inside the exterior wall to interact with one or more chemical or biological substances that come in contact with the probe via the opening to produce a probe sensing signal, and an array of wires that are coupled to probes of the array of hollowed needles, respectively, each wire being electrically conductive to transmit the probe sensing signal produced by a respective probe.