Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidic cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗

Advancing radioactive material research method: the development of a novel in situ particle-attached microfluidic electrochemical cell

This study aims to develop a microgram-scale microfluidic electrochemical cell (E-cell) for investigating the redox behavior of uranium oxide (UO 2 ). The traditional bulk electrochemical methods may require shielded facilities to investigate the hazardous materials, e.g., spent nuclear fuel, due to high radiation levels. Microfluidic E-cells offer advantages such as reduced radiation exposure, control over fluid flow rates, and high-throughput capabilities. Methods: The design of the E-cell considers electrode morphology, adhesion to a thin membrane, electrode configuration, and vacuum compatibility. Three techniques, including FIB-SEM lift-out, Au coating, and polyvinylidene fluoride (PVDF) binder, are explored for fabricating and attaching microgram quantities of UO 2 as working electrodes. The PVDF binder method proves to be the most effective, enabling the creation of a vacuum-compatible microfluidic E-cell. Results and discussion: The PVDF binder method demonstrates successful electrochemical responses and allows for real-time monitoring of UO 2 electrode behavior at the microscale. It offers chemical imaging capabilities using in situ SEM/EDS analysis. The technique provides consistent redox outcomes similar to bulk electrochemical analysis. Conclusion: The development of a microgram-scale microfluidic electrochemical cell using the PVDF binder technique enables the investigation of UO 2 redox behavior. It offers a low-risk approach with reduced radiation exposure and high-throughput capabilities. The technique provides real-time monitoring and chemical imaging capabilities, making it valuable for studying spent nuclear fuel systems and material characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A microfluidic electrochemical cell for studying the corrosion of uranium dioxide (UO 2 )

We have developed a specialized microfluidic electrochemical cell that enables in situ investigation of the electrochemical corrosion of microgram quantities of redox active solids. The advantage of downscaling is the reduction of hazards, waste, expense, and greatly expanding data collection for hazardous materials, including radioactive samples. Cyclic voltammetry was used to monitor the oxidation–reduction cycle of minute quantities of micron-size uraninite (UO 2 ) particles, from the formation of hexavalent uranium (U(VI)), U 3 O 7 and reduction to UO 2+x . Reaction progress was also studied in situ with scanning electron microscopy. The electrochemical measurements matched those obtained at the bulk-scale and were consistent with ex situ characterization of the run products by X-ray photoelectron spectroscopy, scanning transmission electron microscopy, and atomic force microscopy; thus, demonstrating the utility of the microfluidic approach for studying radioactive materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optimizing microfluidic flow cell geometry for in situ resonant soft X-ray characterization of molecular nanostructures

Liquid-phase resonant soft X-ray scattering (LP-RSoXS) is an emerging label-free technique to probe chemically resolved nanostructures of molecular or hybrid materials in liquid environments. Still, quantitative analysis is hindered by the pressure-induced deformation of thin silicon nitride (SiN) membranes used as windows in microfluidic flow cells, which attenuates the signal in nonlinear ways, making experimental optimization difficult. Here, in this work, we directly characterize this deformation under experimental conditions for a variety of cell configurations. We use this to develop a predictive model that combines transmission effects of SiN bowing, incident X-ray beam profiles, and material-dependent resonant scattering cross sections to simulate the effective scattering intensity at the detector across the carbon K-edge. Maps of the total signal across the flow cell window reveal that increasing the window width and polymer concentration shifts the anisotropic intensity distributions from the center toward the edges of the window. It was determined that an optimal SiN thickness of 50 nm, with a window aperture of 104 μm, maximizes the total signal for typical solute concentrations and energies across the carbon K-edge. Our results overturn the assumption that corner regions dominate the scattering signal, offering explicit design guidelines for maximizing LP-RSoXS signals and significantly advancing the quantitative application of this technique to the characterization of molecular and hybrid nanostructured materials in liquids.

Grabner, Devin [Washington State Univ., Pullman, W↗

Studying Cerium Oxide and Uranium Oxide Using Particle Attached Microelectrodes

The conference proceeding presents results of CeO2 and UO2 particles as microelectrodes enclosed in the SALVI E-cell developed in Dr. Yu's lab. These microfluidic cells can be used to study spent fuel materials in minute amount. They offer a flexible and economic way to understand spent fuel oxidation and dissolution in waste storage conditions.

Son, Jiyoung↗

Probing multiscale dissolution dynamics in natural rocks through microfluidics and compositional analysis

Mineral dissolution significantly impacts many geological systems. Carbon released by diagenesis, carbon sequestration, and acid injection are examples where geochemical reactions, fluid flow, and solute transport are strongly coupled. The complexity in these systems involves interplay between various mechanisms that operate at timescales ranging from microseconds to years. Current experimental techniques characterize dissolution processes using static images that are acquired with long measurement times and/or low spatial resolution. These limitations prevent direct observation of how dissolution reactions progress within an intact rock with spatially heterogeneous mineralogy and morphology. We utilize microfluidic cells embedded with thin rock samples to visualize dissolution with significant temporal resolution (100 ms) in a large observation window (3 × 3 mm). Here we injected acidic fluid into eight shale samples ranging from 8 to 86 wt % carbonate. The pre- and postreaction microstructures are characterized at the scale of pores (0.1 to 1 µm) and fractures (1 to 1,000 µm). We observe that nonreactive particle exposure, fracture morphology, and loss of rock strength are strongly dependent on both the relative volume of reactive grains and their distribution. Time-resolved images of the rock unveil the spatiotemporal dynamics of dissolution, including two-phase flow effects in real time and illustrate the changes in the fracture interface across the range of compositions. Moreover, the dynamical data provide an approach for characterizing reactivity parameters of natural heterogeneous samples when porous media effects are not negligible. The platform and workflow provide real-time characterization of geochemical reactions and inform various subsurface engineering processes.

58 GEOSCIENCES↗

Multiphasic droplet microfluidics platform for controlled bacteria and mammalian cell co-culture

Microfluidics has revolutionized high-throughput miniaturized biological assays. However, co-culture of mammalian cells and bacteria remains challenging in microfluidic systems due to incompatible growth requirements, limited spatial control, and the requirement for a mammalian cell adhesion matrix. Here, we present a microfluidic platform that generates multiphasic droplets which encapsulate mammalian and bacterial cells, enabling their direct and indirect co-culture. By combining photopolymerizable hydrogels with polymer phase separation, we generate core–shell droplets composed of a liquid and a hydrogel compartment. The hydrogel compartment supports mammalian cell adhesion and culture, while the liquid compartment sustains bacterial growth. We demonstrate two droplet architectures that allow physical bacteria–mammalian cell contacts or enforce complete physical separation, representing direct and indirect co-culture. Our multiphasic droplets are stable, customizable, able to sustain co-culture for over 24 hours, and compatible with fluorescence-based cell sorting technologies. Overall, our multiphasic droplet microfluidic platform provides a scalable and versatile tool for high-throughput co-culture and screening of host–microbe interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Stamping Nanoparticles onto the Electrode for Rapid Electrochemical Analysis in Microfluidics

Electrochemical analysis is an efficient way to study various materials. However, nanoparticles are challenging due to the difficulty in fabricating a uniform electrode containing nanoparticles. We developed novel approaches to incorporate nanoparticles as a working electrode (WE) in a three-electrode microfluidic electrochemical cell. Specifically, conductive epoxy was used as a medium for direct application of nanoparticles onto the electrode surface. Three approaches in this work were illustrated, including sequence stamping, mix stamping, and droplet stamping. Shadow masking was used to form the conductive structure in the WE surface on a thin silicon nitride (SiN) membrane. Two types of nanomaterials, namely cerium oxide (CeO2) and graphite, were chosen as representative nanoparticles. The as-fabricated electrodes with attached particles were characterized using atomic force microscopy (AFM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Electrochemical analysis was performed to verify the feasibility of these nanoparticles as electrodes. Nanomaterials can be quickly assessed for their electrochemical properties using these new electrode fabrication methods in a microfluidic cell, offering a passport for rapid nanomaterial electrochemical analysis in the future.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fungi-on-a-Chip: microfluidic platforms for single-cell studies on fungi

Abstract This review highlights new advances in the emerging field of ‘Fungi-on-a-Chip’ microfluidics for single-cell studies on fungi and discusses several future frontiers, where we envisage microfluidic technology development to be instrumental in aiding our understanding of fungal biology. Fungi, with their enormous diversity, bear essential roles both in nature and our everyday lives. They inhabit a range of ecosystems, such as soil, where they are involved in organic matter degradation and bioremediation processes. More recently, fungi have been recognized as key components of the microbiome in other eukaryotes, such as humans, where they play a fundamental role not only in human pathogenesis, but also likely as commensals. In the food sector, fungi are used either directly or as fermenting agents and are often key players in the biotechnological industry, where they are responsible for the production of both bulk chemicals and antibiotics. Although the macroscopic fruiting bodies are immediately recognizable by most observers, the structure, function, and interactions of fungi with other microbes at the microscopic scale still remain largely hidden. Herein, we shed light on new advances in the emerging field of Fungi-on-a-Chip microfluidic technologies for single-cell studies on fungi. We discuss the development and application of microfluidic tools in the fields of medicine and biotechnology, as well as in-depth biological studies having significance for ecology and general natural processes. Finally, a future perspective is provided, highlighting new frontiers in which microfluidic technology can benefit this field.

59 BASIC BIOLOGICAL SCIENCES↗

Mineralogy of microbially induced calcium carbonate precipitates formed using single cell drop-based microfluidics

Microbe-mineral interactions are ubiquitous and can facilitate major biogeochemical reactions that drive dynamic Earth processes such as rock formation. One example is microbially induced calcium carbonate precipitation (MICP) in which microbial activity leads to the formation of calcium carbonate precipitates. A majority of MICP studies have been conducted at the mesoscale but fundamental questions persist regarding the mechanisms of cell encapsulation and mineral polymorphism. Here, we are the first to investigate and characterize precipitates on the microscale formed by MICP starting from single ureolytic E. coli MJK2 cells in 25 µm diameter drops. Mineral precipitation was observed over time and cells surrounded by calcium carbonate precipitates were observed under hydrated conditions. Using Raman microspectroscopy, amorphous calcium carbonate (ACC) was observed first in the drops, followed by vaterite formation. ACC and vaterite remained stable for up to 4 days, possibly due to the presence of organics. The vaterite precipitates exhibited a dense interior structure with a grainy exterior when examined using electron microscopy. Autofluorescence of these precipitates was observed possibly indicating the development of a calcite phase. The developed approach provides an avenue for future investigations surrounding fundamental processes such as precipitate nucleation on bacteria, microbe-mineral interactions, and polymorph transitions.

58 GEOSCIENCES↗

Reducing the matrix effect in mass spectral imaging of biofilms using flow-cell culture

The interactions between soil microorganisms and soil minerals play a crucial role in the formation and evolution of minerals and the stability of soil aggregates. Due to the heterogeneity and diversity of the soil environment, the under-standing of the functions of bacterial biofilms in soil minerals at the microscale is limited. A soil mineral-bacterial biofilm system was used as a model in this study, and it was analyzed by time-of-flight secondary ion mass spectrometry (ToF-SIMS) to acquire molecular level information. Static culture in multi-wells and dynamic flow-cell culture in microfluidics of biofilms were investigated. Our results show that more characteristic molecules of biofilms can be observed in SIMS spectra of the flow-cell culture. In contrast, biofilm signature peaks are buried under the mineral components in SIMS spectra in the static culture case. Spectral overlay was used in peak selection prior to performing Principal component analysis (PCA). Comparisons of the PCA results between the static and flow-cell culture show more pronounced molecular features and higher loadings of organic peaks of the dynamic cultured specimens. For example, fatty acids secreted from bacterial biofilm extracellular polymeric substance are likely to be responsible for biofilm dispersal due to mineral treatment up to 48 h. Such findings suggest that the use of microfluidic cells to dynamically culture biofilms be a more suitable method for reducing the matrix effect arisen from the growth medium and minerals as a perturbation fac-tor for improved spectral and multivariate analysis of complex mass spectral data in ToF-SIMS. These results show that the interaction mechanism between biofilms and soil minerals at the molecular level can be better studied using the flow-cell culture and advanced mass spectral imaging techniques like ToF-SIMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrosion of U233-Doped Uranium Oxide using Microfluidics Methods

The aim of work this year has been to investigate the role of alpha (α)-radiation and hydrogen (H 2 ) on the corrosion of uranium oxide (UO 2 ) using a microfluidic device. The microfluidic device, termed the Particle-Attached Microfluidic Electrochemical Cell, (PAMEC), enables monitoring of the UO 2 electrochemical corrosion potential (E corr ) under different environments, including de-aerated conditions and in the presence of dissolved H 2 . The Si 3 N 4 window allows us to study morphological and chemical changes under an electron microscope. We have previously demonstrated that the PAMEC matches the results from bulk electrochemical tests with UO 2 [1]. We used the high specific activity uranium (U) isotope, 233 U, (t 1/2 = 160,000 years) incorporated into UO 2 , to generate a localized a-field. The objective of the experiments were to mimic the radiation environment that would be experience at the surface of aged spent nuclear fuel (SNF) during long-term geologic disposal under anoxic conditions. Wittman et al. [2] predicted that in the presence of a pure a-radiation field and under H 2 conditions, the concentration of the radiolytic oxidant H 2 O 2 would be suppressed or even eliminated. In a UO 2 corrosion experiment this would be exhibited through a lowering of the measured UO 2 corrosion potential compared to identical conditions in the absence of dissolved H 2 . We found that the predictions of Wittman and co-workers were supported and that the corrosion potential of the 233 U-doped UO 2 in solution lowered with presence of H 2 gas and increased in the absence of H 2 , when under anoxic conditions. The PAMEC experiments indicate that H 2 O 2 has been eliminated in a solution sparged with H 2 while exposed to an a-radiation field. The corrosion potential of the a-doped 233 U(10%)- 238 UO 2 in a solution sparged with Ar/H 2 matched the corrosion potential of 238 UO 2 in solution sparged with air. This clearly demonstrated that the H 2 O 2 had been eliminated and that the only oxidant present was O 2 in this system in complete agreement with the modeling results of Wittman et al. These results point to the need to improve the Fuel Matrix Degradation (FMD) Process Model training data set that is being used in the FMD surrogate model that is being developed for the repository program. The incorporation of realistic radiation chemistry will improve the scientific basis for the FMD Model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Studying Corrosion Using Miniaturized Particle Attached Working Electrodes and the Nafion Membrane

We developed a new approach to attach particles onto a conductive layer as a working electrode (WE) in a microfluidic electrochemical cell with three electrodes. Nafion, an efficient proton transfer molecule, is used to form a thin protection layer to secure particle electrodes. Spin coating is used to develop a thin and even layer of Nafion membrane. The effects of Nafion (5 wt% 20 wt%) and spinning rates were evaluated using multiple sets of replicates. The electrochemical performance of various devices was demonstrated. Additionally, the electrochemical performance of the devices is used to select and optimize fabrication conditions. The results show that a higher spinning rate and a lower Nafion concentration (5 wt%) induce a better performance, using cerium oxide (CeO2) particles as a testing model. The WE surfaces were characterized using atomic force microscopy (AFM), scanning electron microscopy-focused ion beam (SEM-FIB), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The comparison between the pristine and corroded WE surfaces shows that Nafion is redistributed after potential is applied. Our results verify that Nafion membrane offers a reliable means to secure particles onto electrodes. Furthermore, the electrochemical performance is reliable and reproducible. Thus, this approach provides a new way to study more complex and challenging particles, such as uranium oxide, in the future.

42 ENGINEERING↗

A novel two-layer-integrated microfluidic device for high-throughput yeast proteomic dynamics analysis at the single-cell level

Abstract Current microfluidic methods for studying multicell strains (e.g., m-types) with multienvironments (e.g., n-types) require large numbers of inlets/outlets (m*n), a complicated procedure or expensive machinery. Here, we developed a novel two-layer-integrated method to combine different PDMS microchannel layers with different functions into one chip by a PDMS through-hole array, which improved the design of a PDMS-based microfluidic system. Using this method, we succeeded in converting 2 × m × n inlets/outlets into m + n inlets/outlets and reduced the time cost of loading processing (from m × n to m) of the device for studying multicell strains (e.g., m-types) in varied multitemporal environments (i.e., n-types). Using this device, the dynamic behavior of the cell-stress-response proteins was studied when the glucose concentration decreased from 2% to a series of lower concentrations. Our device could also be widely used in high-throughput studies of various stress responses, and the new concept of a multilayer-integrated fabrication method could greatly improve the design of PDMS-based microfluidic systems.

Chen, Kaiyue↗

Microfluidic Liquid-Liquid Extraction Chip with Integrated Raman Sensors (Phase I and Phase II Final Report)

As demand for electricity continues to increase worldwide, the world’s nuclear power generating capacity will continue to grow. Nuclear power is the most environmentally benign way of producing electricity on a large scale. The long-term successful use of nuclear power, however, is critically dependent upon adequate and safe processing and disposal of spent nuclear fuels. A very important feature of nuclear energy is that spent fuels can be reprocessed to recover fissile and fertile materials that can then be used as fresh fuel for nuclear power plants. The DOE-NE Fuel Cycle Research and Development (FCR&D) is currently developing nuclear material reprocessing technologies. In a typical nuclear fuel reprocessing system, centrifugal contactors are used as liquid-liquid extraction devices where two immiscible liquids are mixed at high speeds using a rotor, which creates a fine dispersion of droplets of organic phase in an aqueous phase that contains the analyte. Understanding the extraction efficiency at these contactors through modeling and simulation is important in the development of reprocessing technologies and the optimization of current technologies such as the PUREX process. The outcome of this program will be a liquid-liquid microfluidic flow cell chip with embedded spectroscopic sensors for the analysis of extracted analytes. This device will be useful in the optimization of new fuel reprocessing schemes as well as existing reprocessing processes by providing a microfluidic modeling platform to optimize extraction parameters. The Phase I and Phase II work developed a microfluidic chip design that allows integration of Raman and absorption fiber optic probes and successfully demonstrated the feasibility of using Raman and absorption probes to detect key analytes that partition into the aqueous and organic phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An engineered lactate oxidase based electrochemical sensor for continuous detection of biomarker lactic acid in human sweat and serum

Lactate levels in humans reveal intensity and duration of exertion and provide a critical readout for the severity of life-threatening illnesses such as pediatric sepsis. Using the lactate oxidase enzyme (Lox) from Aerococcus viridians, we demonstrated its functionality for lactate electrochemical sensing in physiological fluids in a lab setting. The structure and dynamics of LOx were validated by crystallography, X-ray scattering, and hydroxyl radical protein footprinting. This provided a validated protein template for understanding and designing an enzyme-based electrochemical sensing elements. Using this template, LOx enzyme variants were generated and compared. Comparison of the variants demonstrates that one exhibits effective lactate sensing at significantly reduced operating voltages. Additionally, we demonstrate that the four hexahistidine-tags on each enzyme tetramer are sufficient for immobilization to create a durable, functional sensor, with no need for a covalent attachment, enabling self-immobilization and eliminating the need for additional immobilization steps. The functionality of the LOx enzyme variants was verified at physiological lactate concentrations in both human serum (0–4 mM) and artificial sweat (0–100 mM) using 3-electrode setups for analysis of the three variants in parallel. Accuracy of measurement in both artificial sweat and human serum were high. Employing a microfluidic flow cell, we successfully monitored varying lactate levels in physiological fluids continuously over a 2h period. Overall, this optimized LOx enzyme, which self-immobilizes onto gold sensing electrodes, facilitates efficient and reliable lactate detection and continuous monitoring at reduced operating voltages suitable for further development towards commercial use.

60 APPLIED LIFE SCIENCES↗