Engineering PapersSearch

SEARCH · Engineering Papers

Results for “microfabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

In Situ Liquid Electron Microscope Cells Strongly Attenuate Electrochemical Behavior

In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm 2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.

Wittman, Reed M. [Oak Ridge National Laboratory (O

Microscale Metal Additive Manufacturing by Solid‐State Impact Bonding of Shaped Thin Films

The deposition of device-grade inorganic materials is one key challenge toward the implementation of additive manufacturing (AM) in microfabrication, and to that end, a broad range of physico-chemical principles has been explored for 3D fabrication with micro- and nanoscale resolution. Yet, for metals, a process that achieves material quality rivalling that of established thin-film deposition methods, and at the same time, has the potential to combine high throughput production with a broad palette of processable materials, is still lacking. Here, the kinetic, solid-state bonding of metal thin films for the additive assembly of high-purity, high-density metals with micrometer-scale precision is introduced. Indirect laser ablation accelerates micrometer-thick gold films to hundreds of meters per second without their heating or ablation. Their subsequent impact on the substrate above a critical velocity forms a permanent, metallic bond in the solid state. Stacked layers are of high density (>99%). By defining thin-film layers with established lithographic methods prior to launch, a variable feature size (2–50 µm), arbitrary shape of bonded layers, and parallel transfer of up to 36 independent film units in a single shot, is demonstrated. Thus, the solid-state kinetic bonding principle as a viable and potentially versatile route for micro-scale AM of metals is established.

3D printing

Automated Redox Titrations via Interdigitated Electrode Arrays: Application to the Mediated Electron Transfer Interrogation of Charge and Rate on Electrodeposited Polymers

Mediated electron transfer (MET) plays a crucial role in energy storage and conversion technologies such as redox targeting flow batteries (RTFBs), yet its experimental investigation often requires labor-intensive and low-throughput setups. To address this, we developed a microfabricated interdigitated electrode array (IDA) platform that enables automated, high-throughput electrochemical redox titration measurement to be performed to study the MET process. Our redox titration method enables simultaneous measurement of the charge capacity and rate of MET processes on a material or surface. Automated redox titration (ART) facilitates systematic investigation of the MET process across a broad parameter space, exemplified through the study of polypyrrole (PPy) and a pyrene-4,5,9,10-tetrone azo group-based polymer (PTAP), both redox-active polymers relevant to various energy storage applications. Using PPy as a model material, 500 redox titration measurements were conducted within 50 h, varying the electrode gap widths, polymer charging potentials, voltammetric scan rates, and electrolyte concentrations. Finite-element simulations confirmed the electrochemical responses and elucidated the kinetics of the MET reactions. Our automated methodology was further tested with PTAP, revealing a surprising charging potential dependence on the rate of MET. The automation, flexibility, and scalability of our redox titration platform pave the way not only for advanced studies of MET processes relevant to RTFBs, but also with implications in the understanding of next-generation energy storage materials, molecular electrocatalysis, and biosensing.

electrochemical analysis

Collection of fluorescence from an ion using trap-integrated photonics

Spontaneously emitted photons are entangled with the electronic and nuclear degrees of freedom of the emitting atom, so interference and measurement of these photons can entangle separate matter-based quantum systems as a resource for quantum information processing. Since confinement in a single-mode facilitates the photon interference needed for generating entanglement, the dipole emission patterns relevant in spontaneous emission present a mode-matching challenge. Current demonstrations rely on bulk photon-collection and manipulation optics that suffer from large component size and system-to-system variability—factors that impede scaling to the large numbers of entangled pairs needed for quantum information processing. To address these limitations, we demonstrate a collection method that enables passive phase stability, straightforward photonic manipulation, and intrinsic reproducibility. Specifically, we engineer a waveguide-integrated grating to couple photons emitted from a trapped ion into a single optical mode within a microfabricated ion-trap chip. Using the integrated collection optic, we characterize the collection efficiency, image the ion, and detect the ion’s quantum state. The integrated optic covers 2.18% of the solid angle and collects 1.97 ± 0.3% of the spontaneously emitted light incident on the grating for a total collection efficiency of 0.043% into a single-mode waveguide. This proof-of-principle demonstration lays the foundation for leveraging the inherent stability and reproducibility of integrated photonics to create, manipulate, and measure multipartite quantum states in arrays of quantum emitters.

Optical physics

Patchy nanoparticles by atomic stencilling

Stencilling, in which patterns are created by painting over masks, has ubiquitous applications in art, architecture and manufacturing. Modern, top-down microfabrication methods have succeeded in reducing mask sizes to under 10 nm, enabling ever smaller microdevices as today’s fastest computer chips. Meanwhile, bottom-up masking using chemical bonds or physical interactions has remained largely unexplored, despite its advantages of low cost, solution-processability, scalability and high compatibility with complex, curved and three-dimensional (3D) surfaces. Here we report atomic stencilling to make patchy nanoparticles (NPs), using surface-adsorbed iodide submonolayers to create the mask and ligand-mediated grafted polymers onto unmasked regions as ‘paint’. We use this approach to synthesize more than 20 different types of NP coated with polymer patches in high yield. Polymer scaling theory and molecular dynamics (MD) simulation show that stencilling, along with the interplay of enthalpic and entropic effects of polymers, generates patchy particle morphologies not reported previously. These polymer-patched NPs self-assemble into extended crystals owing to highly uniform patches, including different non-closely packed superlattices. We propose that atomic stencilling opens new avenues in patterning NPs and other substrates at the nanometre length scale, leading to precise control of their chemistry, reactivity and interactions for a wide range of applications, such as targeted delivery, catalysis, microelectronics, integrated metamaterials and tissue engineering.

36 MATERIALS SCIENCE

Label-free structural imaging of plant roots and microbes using third-harmonic generation microscopy

Root biology is pivotal in addressing global challenges including sustainable agriculture and climate change. However, roots have been relatively understudied among plant organs, partly due to the difficulties in imaging root structures in their natural environment. Here we used microfabricated ecosystems (EcoFABs) to establish growing environments with optical access and employed nonlinear multimodal microscopy of third-harmonic generation (THG) and three-photon fluorescence (3PF) to achieve label-free, in situ imaging of live roots and microbes at high spatiotemporal resolution. THG enabled us to observe key plant root structures including the vasculature, Casparian strips, dividing meristematic cells, and root cap cells, as well as subcellular features including nuclear envelopes, nucleoli, starch granules, and putative stress granules. THG from the cell walls of bacteria and fungi also provides label-free contrast for visualizing these microbes in the root rhizosphere. With simultaneously recorded 3PF signal, we demonstrated our ability to investigate root-microbe interactions by achieving single-bacterium tracking and subcellular imaging of fungal spores and hyphae in the rhizosphere.

Pan, Daisong [University of California, Berkeley,

Low-energy ion beam sputtering of polycrystalline diamond

Ion beam milling is a highly versatile and precise technique for the microfabrication of diamond films, enabling controlled material removal at both micrometer and sub-micrometer scales while accommodating complex geometries and surface features. Comprehensive sputtering yield data are essential for process optimization. In this work, we systematically measure the sputter yield of polycrystalline diamond bombarded with $\textrm{N}_2^+$, Ne + , Ar + , Kr + , and Xe + ions over an energy range of 300–900 eV and beam incidence angles of 0°−80°, providing data critical for precision machining applications. Results show that the sputter yield increases with both ion energy and the incidence angle and decreases with increasing ion mass. For $\textrm{N}_2^+$ ions, the sputter yield is largely insensitive to ion energy and exceeds values expected for pure physical sputtering. The concurrent formation of volatile C 2 N 2 molecules during $\textrm{N}_2^+$ ion bombardment suggests that the process is dominated by chemical sputtering. The absence of a peak in the dependence of the sputter yield on the beam incidence angle expected at oblique incidence angles is attributed to the effects of surface roughness.

Materials science

Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography

We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.

36 MATERIALS SCIENCE

Vortex motion induced losses in tantalum resonators

Tantalum (Ta)-based superconducting circuits have been demonstrated to enable ultrahigh qubit quality factors (𝑄), motivating a careful study of the microscopic origin of the remaining losses that limit their performance. We have recently shown that the losses in Ta-based resonators are dominated by two-level systems at low microwave powers and millikelvin temperatures. We also observe that some devices exhibit loss that is exponentially activated at a lower temperature inconsistent with the superconducting critical temperature (T 𝑐 ) of the constituent film. Specifically, dc resistivity measurements show a T 𝑐 of over 4 K, while microwave measurements of resonators fabricated from these films show losses that increase exponentially with temperature with an activation energy as low as 0.3 K. Here, in this study, we present a comparative study of the structural and thermodynamic properties of Ta-based resonators and identify vortex motion-induced loss as the source of thermally activated microwave loss. Through careful magnetoresistance and x-ray diffraction measurements, we observe that the increased loss occurs for films that are in the clean limit, where the superconducting coherence length (𝜉) is shorter than the mean free path (𝑙). Vortex motion-induced losses are suppressed for films in the dirty limit, which show evidence of structural defects that can pin vortices. We verify this hypothesis by explicitly pinning vortices via patterning, and we find that we can suppress the loss by microfabrication.

36 MATERIALS SCIENCE

Interleaved dual-species arrays of single atoms using a passive optical element and one trapping laser

We demonstrate trapping of individual rubidium (Rb) and cesium (Cs) atoms in an interleaved array of bright tweezers and dark bottle-beam traps, using a microfabricated optical element illuminated by a single-laser beam and a 4f system with spatial filtering. Our approach exploits the opposite-sign dynamic polarizabilities of Rb and Cs, ensuring that each species is exclusively trapped in either bright or dark sites. The passive optical mask creates optimal trap depths for both species using three transmittance levels while minimizing the optical phase difference, implemented using a variable-thickness absorbing layer of amorphous germanium. This trapping architecture achieves atom loading rates close to 50% while reducing system complexity compared to conventional methods using active optoelectronic components and/or multiple-laser wavelengths.

Fang, Chengyu [Univ. of Wisconsin, Madison, WI (Un

Ion Traps and Packaging for Heterogenous Integration - Chimera

Microfabricated surface ion traps and silicon-based photonics are critical technologies for scaling quantum systems. Current ion trap architectures face scalability and integration challenges due to limitations in optical access, fabrication techniques, and material compatibility. State-of-the-art quantum computers and atomic clocks are investigating monolithic integration, which necessitates custom traps for each ion species and has not overcome the integration hurdles presented by merging these technologies. The Chimera (Ion Traps and Packaging for Heterogeneous Integration) project proposes a novel approach utilizing heterogeneous integration (HI) of ion traps and photonic circuits. This separation of components allows for flexibility in ion trap design and reduces fabrication compromises. The Chimera project specifically designed an ion trap to interface vertically with a separately fabricated waveguide chip and demonstrates the first steps to integrating them at the packaging level. The ion trap features a large area of removed silicon, allowing the photonics chip outputs closer to the ion trap, improving alignment and packaging processes. The alignment must be accurate to < 1 µm to ensure that the light from the waveguide can overlap with the trapping region. This fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. By combining separate chips, we demonstrate a new path for scaling trapped ion technology that is less reliant on monolithic integration. We successfully fabricated a trap with a large area of oxide removed, resulting in a region thinned to about 40 µm, a key milestone toward successful integration.

42 ENGINEERING

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES

The emergent photophysics and photochemistry of molecular polaritons: a theoretical and computational investigation (Final Technical Report)

When molecules are placed between closely spaced mirrors, they interact strongly with the photons that are trapped between them, generating new quantum states which are no longer exclusively material nor photonic alone, but rather, coherent superpositions of both. These hybrid states are known as molecular polaritons, given that they arise from the strong interaction between the electric field of light and the electrical polarization of the molecules. Recently, experimental advances in nano‐ and microfabrication of molecular polariton architectures have successfully demonstrated their feasibility to control the rate and outcome of a certain class of chemical reactions in condensed phases. Importantly, these reactions proceed in strongly dissipative environments such as liquid solvents and lossy mirrors that allow for photons to escape from their confinement. The purpose of this research is to formulate quantum mechanical theories and computational tools that can elucidate the origin of these intriguing phenomena and simultaneously predict capabilities that this new generation of molecular materials affords. Attention is placed on harnessing polaritons to carry out photophysics and photochemistry that challenge currently existing paradigms, such as the optimization of energy conversion processes in organic solar cell or light‐emitting devices, or unconventional phenomena such as long‐range excitation energy transfer, remote control of chemical reactions, and a new quantum mechanical regime of chemical reactivity due to wavefunction overlaps amongst a large number of molecular polaritons (Bose condensation). This research explores a frontier of Chemistry and Physics where electrons, vibrations, and photons interact strongly with each other to generate emergent behavior that can be creatively exploited to address contemporary challenges in Basic Energy Sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Glass Components Fabricated via Aerosol Jet Printing

Micron-scale glass components are widely used in optical, photonic, and microfabricated systems. These components are commonly produced through grinding, polishing, and milling processes that require tight tolerances and specialized equipment. As device architectures become more compact and geometrically complex, these approaches can constrain design flexibility and integration. Los Alamos researchers developed an additive manufacturing process that builds glass components layer by layer using aerosol jet printing. Glass particles suspended in an aerosolizable carrier solution are deposited onto a substrate and then sintered to form monolithic glass structures. This approach enables controlled fabrication of small glass features without bulk glass melting or post-fabrication machining.

36 MATERIALS SCIENCE

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES