Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microcalorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging

In this paper we present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proofof-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response and showlinear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, our preliminary measurements show energy resolutions of 40-180eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.

47 OTHER INSTRUMENTATION↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution Fission Fragment Spectroscopy with Superconducting Microcalorimeters

Sub-1 AMU mass determination is important for determining fission yields and neutron multiplicity, which are necessary inputs for fission models. Fission models can improve spent nuclear waste stream analysis and nuclear fuel burnup determination. Here, to achieve this goal, we have used superconducting microcalorimeter detectors to directly measure the energy of fission fragments from the spontaneous fission of 252 Cf. With a fiber coupled LED pulser setup we demonstrate that we can reach a relative energy resolution of 0.1% and better for photon pulses with energies above 60 MeV. This instrument, in conjunction with time-of-flight (TOF) measurement, would allow for sub-1 atomic mass unit (AMU) mass determination of fission fragments in a future beamline application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗