Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methods: analytical methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Standard Analytical Methods for Pyrolysis Bio-Oils

There has been significant recent interest in the production of renewable fuels and chemicals from biomass and waste feedstocks. Pyrolysis pathways produce a liquid bio-oil product, which must be processed further, or upgraded, to yield fuel or chemical products. Bio-oils are very complex and often unstable samples, and research and development on upgrading processes needs reliable analytical information. In particular, chemical characterization techniques are needed to quantify both functional groups and individual compounds present in bio-oils. Reliable analytics are also needed to enable the bioenergy industry, as industrial facilities often have different analytical needs and capabilities than research facilities. In this presentation, we will discuss the development of a suite of standard analytical methods for pyrolysis bio-oils. Analytical methods to be discussed include: Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in bio-oils; Accelerated Aging of Fast Pyrolysis Bio-oil using Carbonyl Titration; Determination of Water Content in Bio-oils by Volumetric Karl Fischer Titration; Determination of Carbon Functional Groups; Elemental Analysis of Bio-oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) - Na, K, Mg, Ca, S, P, and Fe; Determination of Phenolic Groups in Bio-oils using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader; Corrosivity of Bio-oils: Screening Test using Metal Leaching; Determination of Biogenic Content by 14C Measurement using Liquid Scintillation Counter. These new analytical methods are publicly available as Laboratory Analytical Procedures (https://www.nrel.gov/bioenergy/bio-oil-analysis.html), along with previously developed standard methods: GC-MS, Acid Titration, Carbonyl Titration, and 31P NMR. Additionally, the development of diffusion ordered NMR for characterization of bio-oil molecular weight will be discussed. Collectively, this suite of analytical methods represents the most comprehensive set of standard methods available for pyrolysis bio-oils. These standard methods are commonly used by the bioenergy community, and provide reliable information that enables research, scaleup, and industrial processing of biomass to produce renewable fuels and chemicals.

analytical↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Unified Analytical Method Greenness Score ( uAMGS ) Quantifies How Microscopic Imaging Is Greener Than Conventional Liquid Chromatography

Green chemistry is a set of principles for assessing, developing, and implementing methods that are safer, more efficient, and less detrimental to the environment. The analytical method greenness score (AMGS) is one of many metrics that attempt to evaluate traditional liquid chromatography (LC) based on the energy consumption of the instrument and the safety, health risks, and environmental impact of the solvents employed. Unfortunately, in practice, the AMGS is primarily focused on traditional separation methods in the pharmaceutical industry and is not amenable to cutting-edge separation science, including miniaturization. To broaden this scope, the unified Analytical Method Greenness Score (uAMGS) is presented here, which clarifies and expands on the underlying mathematics and incorporates both dimensional and uncertainty analysis, enabling its application to a broader range of analytical techniques. The uAMGS is used to compare the greenness of two distinct methods: single-molecule microscopy (SMM) and high-performance liquid chromatography (HPLC), which were used to collect equivalent data. uAMGS determines that SMM is significantly greener than HPLC due primarily to decreased solvent consumption. Overall, the uAMGS should allow chemists ranging from undergraduates to industrial PhDs to assess the greenness of a wide range of separations.

chemical separations↗

Principles of Corrosion in Nuclear Systems: Theory and Analytical Methods

This article is meant to provide the reader with the fundamental electrochemistry necessary to critically evaluate the data and discussions in the articles on corrosion that follow. As such it has two main sections, theory and analytical methods. In the section on theory, a review of half cell reactions, cell potentials and the Nernst equation, and reference electrodes in nuclear systems are discussed. In addition, a review of the thermodynamics from room temperature to the PWR and kinetics of dissolution and passive film formation is also presented. In the section on analytical methods, we review the principles of potentiodynamic polarization, electrochemical impedance spectroscopy, and we introduce a more seldom used technique, Mott-Schottky analysis.

Lillard, R Scott↗

Development and characterization of an aerosol-generated multi-method analytical particle test material

Ceria (CeO 2 ) particles with low to ultra-low loading of nickel dopant were produced using an aerosol-based, droplet-to-particle synthesis via an in-line calcination technique. This aerosol-based synthesis method enables the production of particles with a monodisperse size distribution. These produced and well-characterized, multi-element, ceria-based particles demonstrate a material exemplar for multi-method analytical testing. They were prepared from a cerium nitrate feedstock where low loading nickel dopant was added at target Ni/(Ni + Ce) atomic percents of 1 %, 0.1 %, and 0.01 %, using a nickel nitrate spike. This methodology proved to produce ceria particles doped with a dynamic range of low to ultra-low loadings of nickel over a 24-h period, with consistent size distribution, morphology, and composition. The successful incorporation of nickel was demonstrated with bulk and single particle inductively coupled plasma mass spectroscopy and revealed notable particle-to-particle elemental homogeneity. X-ray photoelectron spectroscopy demonstrated the presence of a high concentration of nickel dopant incorporated preferentially toward the surface of the particles, and that this dopant aided oxidation of surface Ce(III) atoms to Ce(IV). These particle test materials were then validated through X-ray absorption near edge spectroscopy, comparing the ultra-low 0.01 % Ni and low 1 % Ni-doped ceria samples. This revealed a more-reduced oxidation state of the nickel with an increase in dopant concentration. Finally, this work demonstrates a synthesis and systematic characterization scheme to produce multi-method analytical test particulates.

36 MATERIALS SCIENCE↗

Proton Nuclear Magnetic Resonance (H NMR) of Glycolate in Real Waste: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

In preparation for implementing the NG acid flowsheet for the SRS LWS, analytical methods for determining glycolate at low concentration are desired to support system management and safety. Previous work documented that the IC method performed well for samples with low to moderate ionic strength. That work also included a scoping effort to determine if an alternate analytical strategy using H NMR would complement and extend the capabilities of the IC method. The H NMR scoping results indicated that the method had the potential to expand glycolate analysis in LWS samples to higher ionic strength tanks/solutions. The scope of this work is to develop innovative proton NMR techniques, including demonstrating ion exchange decontamination protocols needed for application of the technique to real waste samples. Part of radioactive waste processing at SRS uses formic acid to reduce oxidized (Hg 2+ ) to more volatile elemental Hg for steam striping, collecting, and disposal. Under acidic conditions found in the Chemical Processing Cell (CPC) at the Defense Waste Processing Facility (DWPF), formic acid has a much higher hydrogen generation rate than an alternative reductant, glycolic acid. Thus, an NG acid flowsheet has been developed utilizing glycolic acid with the benefit of easing the need for headspace monitoring requirements for hydrogen and ammonia at DWPF. Low concentrations of glycolate are conservatively assumed to be in the recycle stream, which will collect in the Recycle Collection Tank (RCT). The DWPF recycle stream collected in the RCT has a distinct pathway to the LWS waste tanks that feed the 2H and 3H Evaporator. This route involves transfer of the DWPF recycle to Tank 22 in the Concentration, Storage, and Transfer Facilities (CSTF) followed by transfer to the LWS tank farm/evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Analytics Methods to Measure Plant Outage Resilience

Every 18 or 24 months nuclear power plants (depending on plant configuration, pressurized or boiling water reactor respectively) undergo a period of outage where the plant is taken offline and a large number of maintenance and surveillance activities (that cannot be performed while plant is running) are performed in typically 2–3 weeks. Planning of a plant outage is very challenging since all the activities are required to be performed in the shortest amount of time given available resources (typically contractor crews hired for the duration of the outage). Consequently, plant outages can be costly due the actual loss of power generation and crew costs and, because of it, there is a need to maximize resource usage in the outage planning phase and reduce the risk of outage delays. This paper is addressing these needs by providing a set of analytical methods designed to analyze plant outage schedule and identify critical elements based on available resources (time and crews). These methods are based on natural language processing and optimization algorithms. In this respect, two classes of methods have been developed: one that focuses on the time resource and how variability in the time to complete outage tasks may impact outage delays, and one that minimizes the risk of outage delays by integrating available resources to assess when daily activities should be performed.

97 - MATHEMATICS AND COMPUTING↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

Oak Ridge National Laboratory NCSP Analytical Methods Subtask 3, AMPX Development and Maintenance, and NCSP Nuclear Data Subtask 6, SAMMY Modernization

The modernization of SAMMY continued with consolidation of access to covariance information for adjusted parameters and data in SAMMY. This consolidation allowed for removal of many scratch files. In addition, work was initiated to make the 0K cross section calculation more modular and less dependent on SAMMY global parameters. An initial application programming interface (API) was added to expose cross sections (including resolution broadening) generated by SAMMY to external fitting routines. The processing for thermal moderators in AMPX was updated for selected moderators for which the generated grid was not fine enough. Updated libraries were generated for SCALE. In addition, work continued to fully support new Evaluated Nuclear Data File (ENDF) formats, including the Generalized Nuclear Database Structure (GNDS) in AMPX.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Unified Analytical Method to Quantify Three Types of Fast Frequency Response from Inverter-Based Resources

With more inverter-based resources (IBRs), our power systems have lower frequency nadirs following N-1 contingencies, and undesired under-frequency load shedding (UFLS) can occur. To address this challenge, IBRs can be programmed to provide at least three types of fast frequency response (FFR), e.g., step response, proportional response (P/f droop response), and derivative response (synthetic inertia). However, these heterogeneous FFR challenge the study of power system frequency dynamics. Thus, this paper develops an analytical frequency nadir prediction method that allows for the consideration of all three potential forms of FFR provided by IBRs. The proposed method provides fast and accurate frequency nadir estimation after N-1 generation tripping contingencies. Our method is grounded on the closed-form solution for the frequency nadir, which is solved from the second-order system frequency response model considering the governor dynamics and three types of FFR. The simulation results in the IEEE 39-bus system with different types of FFR demonstrate that the proposed method provides an accurate and fast prediction of the frequency nadir under various disturbances.

fast frequency response↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Analytical Method for Measuring U and Pu Particles by Laser Ablation MC-ICP-MS for the NWAL

This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS.

07 ISOTOPE AND RADIATION SOURCES↗

Validation of Combined Analytical Methods to Predict Slip in Cylindrical Roller Bearings

This paper presents a combination of models that together calculate the cage and roller speeds of a cylindrical roller bearing. The models consider elastohydrodynamic lubrication and contact elasticity between the roller and raceway, roller centrifugal forces, hydrodynamic lubrication at the cage pocket, and frictional forces. Using these models, the predicted cage and roller speeds and the extent of slip are compared to measurements acquired on cylindrical roller bearings in a commercial gearbox in steady-state and transient operating conditions of a wind turbine. In steady-state conditions at low wind speeds and low lubricant temperatures, cage and roller slip up to 60% occur in the loaded zone of the bearing. In the unloaded zone, up to 80% roller slip occurs. Cage and roller slip then decrease as the lubricant temperature and wind speed increases. In general, the analytical model results match experimental measurements within 10% for lubricant temperatures above 40 degrees C and wind speeds over 10 meters per second. The analytical model is further evaluated during a transient start-up event and highly dynamic emergency stop event and also used to examine changes in the bearing design or lubricant properties. Furthermore, roller and cage slip in cylindrical bearings is a combined effect of the bearing design, applied load, shaft speed, and lubricant properties and temperature, and can be quickly evaluated with the combined analytical models.

17 WIND ENERGY↗

Analytical methods for superresolution dislocation identification in dark-field X-ray microscopy

In this work, we develop several inference methods to estimate the position of dislocations from images generated using dark-field X-ray microscopy (DFXM)—achieving superresolution accuracy and principled uncertainty quantification. Using the framework of Bayesian inference, we incorporate models of the DFXM contrast mechanism and detector measurement noise, along with initial position estimates, into a statistical model coupling DFXM images with the dislocation position of interest. We motivate several position estimation and uncertainty quantification algorithms based on this model. We then demonstrate the accuracy of our primary estimation algorithm on synthetic realistic DFXM images of edge dislocations in single-crystal aluminum. We conclude with a discussion of our methods’ impact on future dislocation studies and possible future research avenues.

36 MATERIALS SCIENCE↗