Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fabrication end Deployment Testing of Meter Solar Sail Quadrants for a Scaleable Square Solar Sail Ground Test System

In order for solar sail propulsion technologies to be considered as a viable option for a wide range of near term practical missions a predictable, stable, reliable, manufactureable, scaleable, and cost effective system must be developed and tested first on earth and then on orbit. The design and development of a Scaleable Square Solar Sail System (S^4) is well underway a t AEC-Able Engineering Co. Inc., and the design and production of the Solar Sails for this system is being carried out by SRS Technologies. In April and May of 2004 a single quadrant 10-meter system was tested at NASA LARC's vacuum chamber and a four quadrant 20-meter system has been designed and built for deployment and testing in the Spring of 2005 at NASA/Glenn Research Center's Plumb Brook Facility. SRS has developed an effective and efficient design for triangular sail quadrants that are supported are three points and provide a flat reflective surface with a high fill factor. This sail design is robust enough for deployments in a one atmosphere, one gravity environment and incorporates several advanced features including adhesiveless seaming of membrane strips, compliant edge borders to allow for film membrane cord strain mismatch without causing wrinkling and low mass (3% of total sail mass) ripstop. This paper will outline the sail design and fabrication process, the lessons learned and the resulting mature production, packaging and deployment processes that have been developed. It will also highlight the scalability of the equipment and processes that were developed to fabricate and package the sails. Based on recent experience, SRS is confidant that flight worthy solar sails in the 40-120-meter size range with areal density in the 4-5g/sq m (sail minus structure) range can be produced with existing technology. Additional film production research will lead to further reductions in film thickness to less than 1 micron enabling production of sails with areal densities as low as 20 g/sq m using the current design resulting in a system areal density of as low as 5.3g/sq m. These areal densities are low enough to allow nearly all of the Solar Sail missions that have been proposed by the scientific community and the fundamental technology required to produce these sails has been demonstrated on the ground test sails that have recently been built. These demonstrations have shown that the technology is mature enough to build sails needed to support critical science missions. Solar Sails will be an enabling technology for NASA's Vision for Space Exploration by allowing communication satellite orbits that can maintain continuous communication with the polar regions of the Moon and Mars and to support solar weather monitoring to provide early warning of solar flares and storms that could threaten the safety of astronauts and other spacecraft.

Laue, Greg↗

Liquid helium Dewar for one meter mirror testing

The NASA Ames Research Center has developed a baseline design for a One Meter Cryogenic Optical Test Facility (OMF) incorporating a liquid helium Dewar for cryogenic optical testing of one-meter-class mirrors, principally the Space Infrared Telescope Facility (SIRTF) primary mirror. The primary requirements for the test facility are as follows: (1) the facility must be capable of interferometrically testing any mirror, positioned face-up or face-down, with a diameter less than 1.5 meters and a radius of curvature from 1.5 to 5.5 meters; (2) the facility must achieve and maintain, for 24 hours, a mirror temperature of 4 K with a maximum radiative heat load of less than 500 mW to the mirror, using stored liquid helium and liquid nitrogen; (3) the facility must include a vibration-isolated metrology structure between the test mirror and an external interferometer, and (4) the facility must be operated by two persons and a test, starting from the mounting of a mirror to the removal of a mirror, must be conducted within one week.

Sarver, George L., III↗

Tatsuno Coriolis Flow Meter Development Testing in High Pressure Hydrogen: Cooperative Research and Development Final Report

This project will provide test data on the new Tatsuno coriolis flow meter. This flow meter has been developed by Tatsuno for the purpose of achieving improved flow meter performance for 70 mega pascal (MPA) hydrogen dispensing. Testing will be conducted at the National Renewable Laboratory (NREL) Hydrogen Infrastructure Testing and Research Facility (HITRF) facility utilizing the hydrogen flow meter benchmark testing apparatus. The benchmarking apparatus utilizes a gravimetric method for measuring flow for direct comparison with flow meter output. Using the NREL meter benchmarking apparatus will allow direct comparison with data taken on previous versions of the Tatsuno coriolis flow meter product. Flow meter accuracy at 70 MPA hydrogen dispensers is an issue that has generated a lot of effort by both standards organizations and the station providers.

33 ADVANCED PROPULSION SYSTEMS↗

Automatic control of NASA Langley's 0.3-meter cryogenic test facility

Experience during the past 6 years of operation of the 0.3-meter transonic cryogenic tunnel at the NASA Langley Research Center has shown that there are problems associated with efficient operation and control of cryogenic tunnels using manual control schemes. This is due to the high degree of process crosscoupling between the independent control variables (temperature, pressure, and fan drive speed) and the desired test condition (Mach number and Reynolds number). One problem has been the inability to maintain long-term accurate control of the test parameters. Additionally, the time required to change from one test condition to another has proven to be excessively long and much less efficient than desirable in terms of liquid nitrogen and electrical power usage. For these reasons, studies have been undertaken to: (1) develop and validate a mathematical model of the 0.3-meter cryogenic tunnel process, (2) utilize this model in a hybrid computer simulation to design temperature and pressure feedback control laws, and (3) evaluate the adequacy of these control schemes by analysis of closed-loop experimental data. This paper will present the results of these studies.

Thibodeaux, J. J.↗

Description of the US Army small-scale 2-meter rotor test system

A small-scale powered rotor model was designed for use as a research tool in the exploratory testing of rotors and helicopter models. The model, which consists of a 29 hp rotor drive system, a four-blade fully articulated rotor, and a fuselage, was designed to be simple to operate and maintain in wind tunnels of moderate size and complexity. Two six-component strain-gauge balances are used to provide independent measurement of the rotor and fuselage aerodynamic loads. Commercially available standardized hardware and equipment were used to the maximum extent possible, and specialized parts were designed so that they could be fabricated by normal methods without using highly specialized tooling. The model was used in a hover test of three rotors having different planforms and in a forward flight investigation of a 21-percent-scale model of a U.S. Army scout helicopter equipped with a mast-mounted sight.

Phelps, Arthur E., III↗

Low temperature optical testing of CFRP telescope panels

Since 1984, low temperature optical tests were made of very lightweight mirror panels for use in balloon and space infrared and submillimeter telescopes. In order to accomplish this testing, an ambient pressure 0.5 meter test chamber operating from 20 to -80 C, developed techniques for measuring non-optical quality mirrors with phase modulation 10.6 micron interferometry, and created the interferogram reduction program. During the course of the program, nineteen mirrors from four manufactures were tested: carbon fiber reinforced plastic (CFRP) aluminum honeycomb sandwich panel mirrors, a CFRP sandwich panel with an added glass facesheet, and carbon fiber reinforced glass panels. The results of the panel development and test program are summarized.

Hoffmann, William F.↗

A lunar/Martian anchor emplacement system

On the Moon or Mars, it is necessary to have an anchor, or a stable, fixed point able to support the forces necessary to rescue a stuck vehicle, act as a stake for a tent in a Martian gale, act as a fulcrum in the erection of general construction poles, or support tent-like regolith shields. The anchor emplacement system must be highly autonomous. It must supply the energy and stability for anchor deployment. The goal of the anchor emplacement system project is to design and build a prototype anchor and to design a conceptual anchor emplacement system. Various anchors were tested in a 1.3 cubic meter test bed containing decomposed granite. A simulated lunar soil was created by adjusting the moisture and compaction characteristics of the soil. We conducted tests on emplacement torque, amount of force the anchor could withstand before failure, anchor pull out force at various angles, and soil disturbances caused by placing the anchor. A single helix auger anchor performed best in this test bed based on energy to emplace, and the ultimate holding capacity. The anchor was optimized for ultimate holding capacity, minimum emplacement torque, and minimum soil disturbance in sandy soils yielding the following dimensions: helix diameter (4.45 cm), pitch (1.27 cm), blade thickness (0.15 cm), total length (35.56 cm), shaft diameter (0.78 cm), and a weight of 212.62 g. The experimental results showed that smaller diameter, single-helix augers held more force than larger diameter augers for a given depth. The emplacement system consists of a flywheel and a motor for power, sealed in a protective box supported by four legs. The flywheel system was chosen over a gear system based on its increased reliability in the lunar environment.

Clinton, Dustin↗

The 12-meter truss modal test

The objective of the 12-meter truss modal test is to experimentally determine the frequencies, damping, and mode shapes for the first 6 modes in both principle axes and to use this information to update the FEM. These objectives will lead us to our goal of actively controlling the flexible modes of the truss. A secondary objective is to evaluate our capabilities to ground test this class of structures.

Henderson, Douglas↗

Scale-Up and Modeling Efforts Using an Omniphobic Surface Treatment for Mitigating Solids Deposition

Abstract Gas hydrates, waxes and asphaltenes represent some of the most significant flow assurance challenges, especially in subsea lines, where treatment options can be limited. Currently, complete avoidance is the primary strategy for hydrate management, while chemical or mechanical flushing/pigging may be utilized for other solids. Each system must also be treated with individualized solutions, as there have been no proved one-size-fits-all technologies demonstrated to date. As an alternative to constant chemical injection or thermodynamic controls such as insulation or heating, a robust omniphobic surface treatment material has been developed which has been shown in previous studies to significantly reduce the adhesion of flow assurance solids, resulting in lower risk for deposition and plugging of gas hydrates, waxes, and asphaltenes. As part of a Department of Energy study, laboratory scale tests were performed on a variety of apparatuses ranging from micromechanical force (micron scale) to laboratory flow loop testing (meter scale). While the results from these tests have been promising, there can be some disconnects between lab-scale observations and field-scale testing. Several factors can result in discrepancies between small-scale bench-top studies and deployment-scale efforts. These include flow conditions (Reynolds number, flow regime), chemistry (synthetic vs. crude oils, gas composition, and additives), physical differences (pipeline material, size, and geometry), etc. This work will describe the actions taken to better understand the deployment and performance of a material such as this omniphobic surface treatment in field scenarios, and to build confidence for deployment in a production scenario. These efforts include modeling field production scenarios using models developed from lab observations, application of the material to field-scale equipment to better understand application challenges, and expanded survivability and longevity testing. Understanding the bridge between laboratory testing and full-scale deployment allows for better technique and risk mitigation for field scale testing.

03 NATURAL GAS↗

Responses to LBNP in men with varying profiles of strength and aerobic capacity: Implications for flight crews

Hemodynamic and hormonal responses to lower-body negative pressure (LBNP) were examined in 24 healthy men to test the hypothesis that responsiveness of reflex control of blood pressure during orthostatic stress is associated with strength and/or aerobic capacity. Subjects underwent treadmill tests to determine peak oxygen uptake (peak VO2) and isokinetic dynamo meter tests to determine leg strength. Based on predetermined criteria, the subjects were classified into one of four fitness profiles of six subjects each matched for age, height, and weight: (1) low strength/low aerobic fitness; (2) low strength/high aerobic fitness; (3) high strength/low aerobic fitness; and (4) high strength/high aerobic fitness. Following 90 min of 6 degree head-down tilt (HDT), each subject underwent graded LBNP through -50 mmHg or presyncope, with maximal duration 15 min. All groups exhibited typical hemodynamic, hormonal, and fluid shift responses during LBNP, with no intergroup differences except for catecholamines. Seven subjects, distributed among the four fitness profiles, became presyncopal. Subjects who showed greatest reduction in mean arterial pressure (MAP) during LBNP had greater elevations in vasopressin and lesser increases in heart rate and peripheral resistance. Peak VO2 nor leg strength were correlated with fall in MAP or with syncopal episodes. We conclude that neither aerobic nor strength fitness characteristics are good predictors of responses to LBNP stress.

Convertino, Victor A.↗

Preliminary Design Study for an Eddy Current Flow Meter for Versatile Test Reactor

The eddy current flow meter (ECFM) serves the purpose of monitoring velocities and temperatures of conductive liquid coolant surrounding nuclear reactor cells. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of this flow in reactor cells can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core, as well as, aid in mapping any non-uniformities in fluid flow, its temperature estimation and phase. With modeling and experimental verification, an extensible ECFM for multiple facilities and environments can lead to an understanding of the liquid coolant flow; while saving cost of calibration and development. This can be done by characterizing the ECFM performance based on its parameters and then optimizing a sensor for a given use case. Simulation results using an ECFM and an aluminum rod medium are presented and discussed herein. Additionally, liquid metal simulations for Mercury and Galinstan will compare the ECFM behavior for different liquid velocities and excitation frequencies. After sensor calibration curves are generated and experimentally verified, ECFMs can be developed and deployed using the model introduced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Skin frictional resistance of plane surfaces in air

Given here is the most recent research on skin frictional resistance of plane surfaces in air that was conducted by Dr. Wieselsberger under the direction of Dr. Prandtl of Gottingen University. In all, 16 models were tested. These were divided into four groups, as follows: 1) cloth, in the original condition; 2) cloth, with the nap singed off; 3) cloth, with three coats of dope; and 4) cloth, with six coats of dope. Each group consisted of four models of uniform width, 1 meter, and of lengths of 0.5, 1.0, 1.5, and 2.0 meters. Tests were made on each model at speeds varying from 7.0 to 50 meters per second. The observed total resistance was corrected for the form resistance which was obtained from the pressure distribution on the end of the model. Previous tests had shown that the form resistance due to the rounded front edge used on the models was negligible. The results are expressed in terms of the absolute coefficient of frictionless resistance, C(sub F).

Diehl, W S↗

Fabrication and Deployment Testing of Solar Sail Quadrants for a 20-Meter Solar Sail Ground Test System Demonstration

A 20-meter Scalable Square Solar Sail (S(sup 4)) System was produced and successfully completed functional vacuum testing in NASA Glenn's Space Power Facility at Plum Brook Station Ohio in May 2005. The S(sup 4) system was designed and developed by ATK Space Systems, and the design and production of the Solar Sails for this system was carried out by SRS Technologies. The S(sup 4) system consists of a central structure with four deployable carbon fiber masts that support four triangular sails. SRS has developed an effective and efficient design for triangular sail quadrants that are supported at three points and provide a flat reflective surface with a high fill factor. This sail design is robust enough for deployments in a one atmosphere, one gravity environment and incorporates several advanced features including adhesiveless seaming of membrane strips, compliant edge borders to allow for film membrane cord strain mismatch without causing wrinkling and low mass (3% of total sail mass) ripstop. This paper will outline some of the sail design and fabrication processes and the mature production, packaging and deployment processes that have been developed. This paper will also detail the successful ambient and vacuum testing of the sails and the ATK spacecraft structure. Based on recent experience and testing, SRS is confidant that high Technology Readiness Level (TRL) 5-6 solar sails in the 40-120-meter size range with areal density in the 4-5 grams per square meters (sail minus structure) range can be produced with existing technology. Additional film production research will lead to further reductions in film thickness to less than 1 micron enabling production of sails with areal densities as low as 2.0 grams per square meters using the current design, resulting in a system areal densities as low as 5.3 grams per square meters (sail and structure). These areal densities are low enough to allow nearly all of the Solar Sail missions that have been proposed by the scientific community. The fundamental technologies required to produce these systems has been demonstrated on the 20-meter S(sup 4) sails that have recently completed ground testing demonstrating a mature and technology suitable for incorporation into future flight validation and future mission. Solar Sails can support NASA's Vision for Space Exploration by allowing communication satellite orbits that can maintain continuous communication with the polar regions of the Moon and Mars and to support solar weather monitoring to provide early warning of solar flares and storms that could threaten the safety of astronauts and other spacecraft.

Laue, Greg↗

TESTING OF A 20-METER SOLAR SAIL SYSTEM

This paper describes the structural dynamic tests conducted in-vacuum on the Scalable Square Solar Sail (S(sup 4)) System 20-meter test article developed by ATK Space Systems as part of a ground demonstrator system development program funded by NASA's In-Space Propulsion program1-3. These tests were conducted for the purpose of validating analytical models that would be required by a flight test program to predict in space performance4. Specific tests included modal vibration tests on the solar sail system in a 1 Torr vacuum environment using various excitation locations and techniques including magnetic excitation at the sail quadrant corners, piezoelectric stack actuation at the mast roots, spreader bar excitation at the mast tips, and bi-morph piezoelectric patch actuation on the sail cords. The excitation methods were evaluated for their suitability to in-vacuum ground testing and their traceability to the development of on-orbit flight test techniques. The solar sail masts were also tested in ambient atmospheric conditions and these results are also discussed.

Gaspar, J. L.↗

TESTING OF A 20-METER SOLAR SAIL SYSTEM

This paper describes the structural dynamic tests conducted in-vacuum on the Scalable Square Solar Sail (S(sup 4)) System 20-meter test article developed by ATK Space Systems as part of a ground demonstrator system development program funded by NASA's In-Space Propulsion program. These tests were conducted for the purpose of validating analytical models that would be required by a flight test program to predict in space performance. Specific tests included modal vibration tests on the solar sail system in a 1 Torr vacuum environment using various excitation locations and techniques including magnetic excitation at the sail quadrant corners, piezoelectric stack actuation at the mast roots, spreader bar excitation at the mast tips, and bi-morph piezoelectric patch actuation on the sail cords. The excitation methods are evaluated for their suitability to in-vacuum ground testing and their traceability to the development of on-orbit flight test techniques. The solar sail masts were also tested in ambient atmospheric conditions and these results are also discussed.

Gaspar, Jim L.↗

Analysis of test data film generated by the lunar sounder (S-209)

The analysis of test films pertaining to the readiness of the Apollo 17 radar equipment is discussed. Emphasis is placed on the evaluation of the lunar sounder equipment. The lunar sounder experiment was to examine the lunar surface at three different radar frequencies of 2 meters, 60 meters, and 20 meters. Test films were made on the lunar sounder system to describe the purpose of the test, to describe the experiments used for analysis, and to provide conclusions reached after analysis.

Massey, N.↗

Design, fabrication and test of graphite/epoxy metering truss structure components, phase 3

The design, materials, tooling, manufacturing processes, quality control, test procedures, and results associated with the fabrication and test of graphite/epoxy metering truss structure components exhibiting a near zero coefficient of thermal expansion are described. Analytical methods were utilized, with the aid of a computer program, to define the most efficient laminate configurations in terms of thermal behavior and structural requirements. This was followed by an extensive material characterization and selection program, conducted for several graphite/graphite/hybrid laminate systems to obtain experimental data in support of the analytical predictions. Mechanical property tests as well as the coefficient of thermal expansion tests were run on each laminate under study, the results of which were used as the selection criteria for the single most promising laminate. Further coefficient of thermal expansion measurement was successfully performed on three subcomponent tubes utilizing the selected laminate.

Source record↗