Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mass spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal decomposition of CH{sub 3}CHO studied by matrix infrared spectroscopy and photoionization mass spectroscopy

A heated SiC microtubular reactor has been used to decompose acetaldehyde and its isotopomers (CH{sub 3}CDO, CD{sub 3}CHO, and CD{sub 3}CDO). The pyrolysis experiments are carried out by passing a dilute mixture of acetaldehyde (roughly 0.1%-1%) entrained in a stream of a buffer gas (either He or Ar) through a heated SiC reactor that is 2-3 cm long and 1 mm in diameter. Typical pressures in the reactor are 50-200 Torr with the SiC tube wall temperature in the range 1200-1900 K. Characteristic residence times in the reactor are 50-200 {mu}s after which the gas mixture emerges as a skimmed molecular beam at a pressure of approximately 10 {mu}Torr. The reactor has been modified so that both pulsed and continuous modes can be studied, and results from both flow regimes are presented. Using various detection methods (Fourier transform infrared spectroscopy and both fixed wavelength and tunable synchrotron radiation photoionization mass spectrometry), a number of products formed at early pyrolysis times (roughly 100-200 {mu}s) are identified: H, H{sub 2}, CH{sub 3}, CO, CH{sub 2}=CHOH, HC{identical_to}CH, H{sub 2}O, and CH{sub 2}=C=O; trace quantities of other species are also observed in some of the experiments. Pyrolysis of rare isotopomers of acetaldehyde produces characteristic isotopic signatures in the reaction products, which offers insight into reaction mechanisms that occur in the reactor. In particular, while the principal unimolecular processes appear to be radical decomposition CH{sub 3}CHO (+M) {yields} CH{sub 3}+ H + CO and isomerization of acetaldehyde to vinyl alcohol, it appears that the CH{sub 2}CO and HCCH are formed (perhaps exclusively) by bimolecular reactions, especially those involving hydrogen atom attacks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Invariant mass spectroscopy of halo nuclei

We have applied the invariant mass spectroscopy to explore the low-lying exited states of halo nuclei at intermediate energies around 70 MeV/nucleon at RIKEN. As examples, we show here the results of Coulomb breakup study for {sup 11}Li using the Pb target, as well as breakup reactions of {sup 14}Be with p and C targets. The former study revealed a strong Coulomb breakup cross section reflecting the large enhancement of E1 strength at low excitation energies (soft E1 excitation). The latter revealed the observation of the first 2{sup +} state in {sup 14}Be.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High spatial resolution mapping of deposition layers on plasma facing materials by laser ablation microprobe time-of-flight mass spectroscopy

A laser ablation microprobe time-of-flight mass spectroscopy (LAM-TOF-MS) system with high spatial resolution, ∼20 nm in depth and ∼500 μm or better on the surface, is developed to analyze the composition distributions of deposition layers on the first wall materials or first mirrors in tokamak. The LAM-TOF-MS system consists of a laser ablation microprobe combined with a TOF-MS and a data acquisition system based on a LabVIEW program software package. Laser induced ablation combined with TOF-MS is an attractive method to analyze the depth profile of deposited layer with successive laser shots, therefore, it can provide information for composition reconstruction of the plasma wall interaction process. In this work, we demonstrate that the LAM-TOF-MS system is capable of characterizing the depth profile as well as mapping 2D composition of deposited film on the molybdenum first mirror retrieved from HL-2A tokamak, with particular emphasis on some of the species produced during the ablation process. The presented LAM-TOF-MS system provides not only the 3D characterization of deposition but also the removal efficiency of species of concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging mass spectroscopy delineates the thinned and thickened walls of intracranial aneurysms

Highlights: • Heterogeneity of IA walls was examined with imaging mass spectroscopy. • Phosphatidylinositol (PI 18:0/20:4) was more abundant in the thickened wall of IAs. • SMCs in thick and thin wall were dedifferentiated and differentiated, respectively. • Dedifferentiated SMCs had higher levels of PI (18:0/20:4) than differentiated SMCs. • PI (18:0/20:4) could be associated with phenotypic switching of SMCs in rat IAs. The wall thickness of intracranial aneurysms (IAs) is heterogeneous. Although thinning of the IA wall is thought to contribute to IA rupture, the underlying mechanism remains poorly understood. Recently, imaging mass spectroscopy (IMS) has been used to reveal the distribution of phospholipids in vascular diseases. To investigate the feature of phospholipid composition of IA walls, we conducted IMS in a rat model of experimentally induced IA.

60 APPLIED LIFE SCIENCES↗

Campaign 1.7 Pu Aging. Development of Time of Flight Secondary Ion Mass Spectroscopy

The first application of Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS) to an aged plutonium surface has resulted in a rich set of surface chemistry data, as well as some unexpected results. FY15 was highlighted by not only the first mapping of hydrogen-containing features within the metal, but also a prove-in series of experiments using the system’s Sieverts Reaction Cell. These experiments involved successfully heating the sample to ~450 oC for nearly 24 hours while the sample was dosed several times with hydrogen, followed by an in situ ToF-SIMS analysis. During this year, the data allowed for better and more consistent identification of the myriad peaks that result from the SIMS sputter process. In collaboration with the AWE (U.K), the system was also fully aligned for sputter depth profiling for future experiments.

36 MATERIALS SCIENCE↗

Secondary ions mass spectroscopy measurements of dopant impurities in highly stressed InGaN laser diodes

We performed a systematic secondary ions mass spectroscopy (SIMS) study of dopant impurities in life-time stressed InGaN laser devices in order to investigate the main degradation mechanism that is observed in nitride laser diodes. A continuous wave (cw) current density of 3 kA/cm{sup 2} was applied to InGaN laser diodes over an extended period of time and we observed the characteristic square root degradation of optical power. We compared the SIMS profiles of Mg, H, and Si impurities in the aged devices and observe that the impurities are remarkably stable over 10 000 h of cw operation. Nor is there any SIMS evidence of p-contact metals penetrating into the semiconductor material. Thus our SIMS results are contrary to what one would expect for impurity diffusion causing the observed square root degradation characteristic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Secondary ion counting for surface-sensitive chemical analysis of organic compounds using time-of-flight secondary ion mass spectroscopy with cluster ion impact ionization

We report suitable secondary ion (SI) counting for surface-sensitive chemical analysis of organic compounds using time-of-flight (TOF) SI mass spectroscopy, based on considerably higher emission yields of SIs induced by cluster ion impact ionization. A SI counting system for a TOF SI mass spectrometer was developed using a fast digital storage oscilloscope, which allows us to perform various types of analysis as all the signal pulses constituting TOF SI mass spectra can be recorded digitally in the system. Effects of the SI counting strategy on SI mass spectra were investigated for C{sub 8} and C{sub 60} cluster ion impacts on an organically contaminated silicon wafer and on polytetrafluoroethylene targets by comparing TOF SI mass spectra obtained from the same recorded signals with different SI counting procedures. Our results show that the use of a counting system, which can cope with high SI yields, is necessary for quantitative analysis of SI mass spectra obtained under high SI yield per impact conditions, including the case of cluster ion impacts on organic compounds.

36 MATERIALS SCIENCE↗

Soft x-ray induced Ag diffusion in amorphous pulse laser deposited As{sub 50}Se{sub 50} thin films: An x-ray photoelectron and secondary ion mass spectroscopy study

In the present paper, x-ray photoelectron spectroscopy (XPS) is used to induce and study the Ag diffusion and dissolution in pulsed laser deposited As{sub 50}Se{sub 50} amorphous chalcogenide films. Dynamic secondary ion mass spectroscopy (SIMS) is also employed to investigate the Ag atomic concentration in depth. Dynamic SIMS measurements reveal that even before x-ray irradiation a considerable percentage of the total silver amount diffuses into the matrix forming an {approx}70 nm mixed Ag-Se-As layer. XPS analysis shows that x-ray irradiation induces further diffusion of silver into the chalcogenide matrix. At the end of the procedure silver is found to be homogeneously dissolved into the matrix leaving only a 5-7 nm thick surface layer with excess silver concentration. In this surface layer stable Ag{sub 2}Se clusters existing probably in quasicrystalline form prohibit further diffusion. The origin of the mechanism of the x-ray induced Ag diffusion and dissolution in amorphous chalcogenides is discussed in light of the present results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Alternate Stainless Steel Surface Treatments for Mass Spectroscopy and Other Tritium Systems

There are specific components in the SRS Tritium Facilities that are required to introduce as few chemical impurities (such as protium and methane) as possible into the process gas. Two such components are the inlet systems for the mass spectroscopy facilities and hydrogen isotope mix standard containers. Two vendors now passivate stainless steel components for these systems, and both are relatively small businesses whose future viability can be questioned, which creates the need for new sources. Stainless steel containers were designed to evaluate alternate surface treatment vendors for tritium storage and handling for these high purity tritium systems. Five vendors applied their own 'best' surface treatments to two containers each - one was a current vendor, another was a chemical vapor deposited silicon coating, and the other three were electropolishing and chemical cleaning vendors. Pure tritium gas was introduced into all ten containers and the composition was monitored over time. The only observed impurities in the gas were some HT, less CT 4 , and very small amounts of T 2 O in all cases. The currently used vendor treated containers contained the least impurities. The chemical vapor deposited silicon treatment resulted in the highest impurity levels. Sampling one set of containers after about one month of tritium exposure revealed the impurity level to be nearly the same as that after more than a year of exposure - this result suggests that cleaning new stainless steel components by tritium gas contact for about a month may be a worthy operation.

03 NATURAL GAS↗

Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or flourometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress.

60 APPLIED LIFE SCIENCES↗

Flame-Sampling Photoionization Mass Spectroscopy: Studies of Flame Chemistry with Sampling Photoionization Mass Spectrometry

Research focused on detailed studies of the complex combustion chemistry of oxygenated, bio-derived fuels. In particular, studies were done of the flame chemistry of simple methyl and ethyl esters chosen as surrogates for the long-chain esters that are primary constituents of biodiesel fuels. The principal goals of these studies were: (1) show how fuel-specific structural differences including degree of unsaturation, linear vs. branched chain structures, and methoxy vs. ethoxy functions affect fuel-destruction pathways, (2) understand the chemistry leading to potential increases in the emissions of hazardous air pollutants including aldehydes and ketones inherent in the use of biodiesel fuels, and (3) define the key chemical reaction mechanisms responsible for observed reductions in polycyclic aromatic hydrocarbons and particulate matter when oxygenated fuels are used as replacements for conventional fuels.

10 SYNTHETIC FUELS↗

Evolution of shell gaps in the neutron-poor calcium region from invariant-mass spectroscopy of 37,38 Sc, 35 Ca, 34 K

A fast secondary beam of 37 Ca impinged on a 9 Be target resulting in a set of reactions populating proton-rich nuclei including 35 Ca and the first observations of 37,38 Sc and 34 K. Invariant-mass spectroscopy, used to reconstruct proton decays for these nuclei, yielded three new ground-state masses and information on their low-lying structures. The newly measured mass excesses are: ΔM( 37 Sc) = 3500(410) keV, ΔM( 38 Sc) = –4656(14) keV, and ΔM( 34 K) = –1487(17) keV. These nuclei straddle the well-known Z = 20 shell closure as well as the N = 16 subshell closure. Furthermore, trends in separation energies help elucidate how nuclear structure evolves showing a fading of the Z = 20 shell gap for N ≥ 18 and indications of a N = 16 subshell gap.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural changes and thermal stability of charged LiNi x Mn y Co z O 2 cathode materials studied by combined in situ time-resolved XRD and mass spectroscopy

Thermal stability of charged LiNi x Mn y Co z O 2 (NMC, with x + y + z = 1, x:y:z = 4:3:3 (NMC433), 5:3:2 (NMC532), 6:2:2 (NMC622), and 8:1:1 (NMC811)) cathode materials is systematically studied using combined in situ time- resolved X-ray diffraction and mass spectroscopy (TR-XRD/MS) techniques upon heating up to 600 °C. The TR-XRD/MS results indicate that the content of Ni, Co, and Mn significantly affects both the structural changes and the oxygen release features during heating: the more Ni and less Co and Mn, the lower the onset temperature of the phase transition (i.e., thermal decomposition) and the larger amount of oxygen release. Interestingly, the NMC532 seems to be the optimized composition to maintain a reasonably good thermal stability, comparable to the low-nickel-content materials (e.g., NMC333 and NMC433), while having a high capacity close to the high-nickel-content materials (e.g., NMC811 and NMC622). The origin of the thermal decomposition of NMC cathode materials was elucidated by the changes in the oxidation states of each transition metal (TM) cations (i.e., Ni, Co, and Mn) and their site preferences during thermal decomposition. It is revealed that Mn ions mainly occupy the 3a octahedral sites of a layered structure (R3¯m) but Co ions prefer to migrate to the 8a tetrahedral sites of a spinel structure (Fd3¯m) during the thermal decomposition. Such element-dependent cation migration plays a very important role in the thermal stability of NMC cathode materials. The reasonably good thermal stability and high capacity characteristics of the NMC532 composition is originated from the well-balanced ratio of nickel content to manganese and cobalt contents. As a result, this systematic study provides insight into the rational design of NMC-based cathode materials with a desired balance between thermal stability and high energy density.

25 ENERGY STORAGE↗