Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mass spectrometry simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

An analysis of nuclear fuel burnup in the AGR-1 TRISO fuel experiment using gamma spectrometry, mass spectrometry, and computational simulation techniques

AGR 1 was the first in a series of experiments designed to test US TRISO fuel under high temperature gas-cooled reactor irradiation conditions. This experiment was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and is currently undergoing post irradiation examination (PIE) at INL and Oak Ridge National Laboratory. One component of the AGR 1 PIE is the experimental evaluation of the burnup of the fuel by two separate techniques. Gamma spectrometry was used to non destructively evaluate the burnup of all 72 of the TRISO fuel compacts that comprised the AGR 1 experiment. Two methods for evaluating burnup by gamma spectrometry were developed, one based on the Cs 137 activity and the other based on the ratio of Cs 134 and Cs 137 activities. Burnup values determined from both methods compared well with the values predicted from simulations. The highest measured burnup was 20.1% FIMA for the direct method and 20.0% FIMA for the ratio method (compared to 19.56% FIMA from simulations). An advantage of the ratio method is that the burnup of the cylindrical fuel compacts can determined in small (2.5 mm) axial increments and an axial burnup profile can be produced. Destructive chemical analysis by inductively coupled mass spectrometry (ICP MS) was then performed on selected compacts that were representative of the expected range of fuel burnups in the experiment to compare with the burnup values determined by gamma spectrometry. The compacts analyzed by mass spectrometry had a burnup range of 19.3% FIMA to 10.7% FIMA. The mass spectrometry evaluation of burnup for the four compacts agreed well with the gamma spectrometry burnup evaluations and the expected burnup from simulation. For all four compacts analyzed by mass spectrometry, the maximum range in the three experimentally determined values and the predicted value was 6% or less. Furthermore, the results confirm the accuracy of the nondestructive burnup evaluation from gamma spectrometry for TRISO fuel compacts across a burnup range of approximately 10 to 20% FIMA and also validate the approach used in the physics simulation of the AGR 1 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulating data processing for an Advanced Ion Mobility Mass Spectrometer

We have designed and implemented a Cray XD-1-based sim- ulation of data capture and signal processing for an ad- vanced Ion Mobility mass spectrometer (Hadamard trans- form Ion Mobility). Our simulation is a hybrid application that uses both an FPGA component and a CPU-based soft- ware component to simulate Ion Mobility mass spectrome- try data processing. The FPGA component includes data capture and accumulation, as well as a more sophisticated deconvolution algorithm based on a PNNL-developed en- hancement to standard Hadamard transform Ion Mobility spectrometry. The software portion is in charge of stream- ing data to the FPGA and collecting results. We expect the computational and memory addressing logic of the FPGA component to be portable to an instrument-attached FPGA board that can be interfaced with a Hadamard transform Ion Mobility mass spectrometer.

99 GENERAL AND MISCELLANEOUS↗

Charge Prediction of Lipid Fragments in Mass Spectrometry

An artificial neural network is developed for predicting which fragment is charged and which fragment is neutral for lipid fragment pairs produced from a liquid chromatography tandem mass spectrometry simulation process. This charge predictor is integrated into software developed at PNNL for in silico spectra generation and identification of metabolites known as Met ISIS. To test the effect of including charge prediction in Met ISIS, 46 lipids are used which show a reduction in false positive identifications when the charge predictor is utilized.

Met ISIS↗

Predicting the structural basis of targeted protein degradation by integrating molecular dynamics simulations with structural mass spectrometry

Targeted protein degradation (TPD) is a promising approach in drug discovery for degrading proteins implicated in diseases. A key step in this process is the formation of a ternary complex where a heterobifunctional molecule induces proximity of an E3 ligase to a protein of interest (POI), thus facilitating ubiquitin transfer to the POI. In this work, we characterize 3 steps in the TPD process. (1) We simulate the ternary complex formation of SMARCA2 bromodomain and VHL E3 ligase by combining hydrogen-deuterium exchange mass spectrometry with weighted ensemble molecular dynamics (MD). (2) We characterize the conformational heterogeneity of the ternary complex using Hamiltonian replica exchange simulations and small-angle X-ray scattering. (3) We assess the ubiquitination of the POI in the context of the full Cullin-RING Ligase, confirming experimental ubiquitinomics results. Differences in degradation efficiency can be explained by the proximity of lysine residues on the POI relative to ubiquitin.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation

The freely available “Stopping and Range of Ions in Matter” (SRIM) code is used for evaluating ion beam ranges and depth profiles. We present secondary ion mass spectrometry and Rutherford backscattering experimental results of Si samples implanted with low energy Sb ions to evaluate the accuracy of SRIM simulations. We show that the SRIM simulation systematically overestimates the range by 2–6 nm and this overestimation increases for larger ion implantation energy. For the lowest energy implantation investigated, here we find up to a 25% error between the SRIM simulation and the measured range. Finally, the ion straggle shows excellent agreement between simulation and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distance Restraints from Crosslinking Mass Spectrometry: Mining a Molecular Dynamics Simulation Database to Evaluate Lysine-Lysine Distances

Integrative structural biology models the structures of protein complexes that are intractable by classical structural methods (because of extreme size, dynamics, or heterogeneity) by combining computational structural modeling with data from experimental methods. One such method is chemical cross-linking mass spectrometry (XL-MS), in which cross-linked peptides, derived from a covalently cross-linked protein complex and identified by liquid chromatography-mass spectrometry, pinpoint protein residues close in three-dimensional space. The commonly used lysine-reactive N-hydroxysuccinimide ester reagents disuccinimidylsuberate (DSS) and bis(sulfosuccinimidyl)suberate (BS3) have a linker arm that is 11.4 Å long when fully extended. However, XL-MS studies on proteins of known structure frequently report cross-links that exceed this distance. Typically, a tolerance of ~3 Å is added to the theoretical maximum to account for this observation, with little justification for the value chosen. We used the Dynameomics database, a repository of high-quality molecular dynamics simulations of 807 proteins representative of all protein folds, to investigate the change in lysine-lysine distances resulting from native-state dynamics on the time-scale of tens of nanoseconds. We conclude that observed cross-links are consistent with a protein structure if the distance between cross-linked lysine Nζ atoms is less than the cross-linker length plus 11.3 Å. For DSS or BS3, this corresponds to a Cα to Cα distance of 30.4 Å. This analysis provides a theoretical basis for the widespread practice of adding a tolerance to the crosslinker length when comparing XL-MS results to structures, and indicates the appropriate values of an XLMS derived distance constraint to use in structural modeling.

Environmental Molecular Sciences Laboratory↗

Formation and consumption of NO in H{sub 2} + O{sub 2} + N{sub 2} flames doped with NO or NH{sub 3} at atmospheric pressure

Flat premixed burner-stabilized H{sub 2} + O{sub 2} + N{sub 2} flames, neat or doped with 300-1000 ppm of NO or NH{sub 3}, were studied experimentally using molecular-beam mass-spectrometry and simulated numerically. Spatial profiles of temperature and concentrations of stable species, H{sub 2}, O{sub 2}, H{sub 2}O, NO, NH{sub 3}, and of H and OH radicals obtained at atmospheric pressure in lean ({phi} = 0.47), near-stoichiometric ({phi} = 1.1) and rich ({phi} = 2.0) flames are reported. Good agreement between measured and calculated structure of lean and near-stoichiometric flames was found. Significant discrepancy between simulated and measured profiles of NO concentration was observed in the rich flames. Sensitivity and reaction path analyses revealed reactions responsible for the discrepancy. Modification to the model was proposed to improve an overall agreement with the experiment. (author)

08 HYDROGEN↗

Quantification of the ion and momentum fluxes toward the substrate during reactive magnetron sputtering

The ion and momentum fluxes toward the growing film during reactive magnetron sputtering of a Ti target in a mixture of Ar and N{sub 2} are determined. For the ion flux and ion energy distribution a retarding field energy analyzer has been employed. The results were confronted with planar and cylindrical probe measurements, two more common used techniques. For the momentum flux, energy resolved mass spectrometry and simulations with the binary collision Monte Carlo code SIMTRA were performed to determine the contribution to this flux by the impact of ions and sputtered and reflected particles. Based on the quantification of both fluxes, it can be concluded that there is a relation between the hardness and elastic modulus of the TiN films and the momentum flux.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of Protonated Peptide Ion Collisions with Organic Surfaces: Consonance of Simulation and Experiment

In this Perspective mass spectrometry experiments and chemical dynamics simulations are described which have explored the atomistic dynamics of protonated peptide ions, peptide-H+, colliding with organic surfaces. These studies have investigated surface-induced dissociation (SID) for which peptide-H+ fragments upon collision with the surface, peptide-H+ physisorption on the surface, soft landing (SL), and peptide-H+ reaction with the surface, reactive landing (RL). The simulations include QM+MM and QM/MM direct dynamics. For collisions with self-assembled monolayer (SAM) surfaces there is quite good agreement between experiment and simulation in the efficiency of energy transfer to the peptide-H+ ion’s internal degrees of freedom. Both the experiments and simulations show two mechanisms for peptide-H+ fragmentation, i.e. shattering and statistical, RRKM dynamics. Mechanisms for SL are probed in simulations of collisions of protonated dialanine with a perfluorinated SAM surface. RL has been studied experimentally for a number of peptide-H+ + surface systems, and qualitative agreement between simulation and experiment is found for two similar systems.

Pratihar, Subha↗

Towards secondary ion mass spectrometry on the helium ion microscope: An experimental and simulation based feasibility study with He{sup +} and Ne{sup +} bombardment

The combination of the high-brightness He{sup +}/Ne{sup +} atomic level ion source with secondary ion mass spectrometry detection capabilities opens up the prospect of obtaining chemical information with high lateral resolution and high sensitivity on the Zeiss ORION helium ion microscope. The analytical performance in terms of sputtering yield, useful yield, and detection limit is studied and subsequently optimized by oxygen and cesium flooding. Detection limits down to 10{sup -6} and 10{sup -5} can be obtained for silicon using Ne{sup +} and He{sup +}, respectively. A simulation based study reveals furthermore that a lateral resolution <10 nm can be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new interpretation for performance improvement of high-efficiency vertical blue light-emitting diodes by InGaN/GaN superlattices

The effect of InGaN/GaN superlattices (SLs) on quantum efficiency and forward voltage of vertical blue InGaN/GaN multiple quantum well (MQW) light-emitting diodes (LED) grown on Si substrate has been experimentally and theoretically investigated. We have prepared two LED samples, in which the 30 and 45 periods of SLs are inserted between MQW active layers and n-GaN layer, respectively. Electroluminescence measurement shows that the LED with 45 periods of SLs has higher quantum efficiency but lower forward voltage. It is observed that V-shaped pits grow up in size with an increase in SLs period number by means of scan transmission electron microscope and secondary ion mass spectrometry. Further numerical simulations confirm that the performance improvement of LED by SLs is mainly ascribed to enhancing hole injection from the V-shaped pits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Insight into the autoproteolysis mechanism of the RsgI9 anti‐σ factor from Clostridium thermocellum

Abstract Clostridium thermocellum is a potential microbial platform to convert abundant plant biomass to biofuels and other renewable chemicals. It efficiently degrades lignocellulosic biomass using a surface displayed cellulosome, a megadalton sized multienzyme containing complex. The enzymatic composition and architecture of the cellulosome is controlled by several transmembrane biomass‐sensing RsgI‐type anti‐σ factors. Recent studies suggest that these factors transduce signals from the cell surface via a conserved RsgI extracellular (CRE) domain (also called a periplasmic domain) that undergoes autoproteolysis through an incompletely understood mechanism. Here we report the structure of the autoproteolyzed CRE domain from the C. thermocellum RsgI9 anti‐σ factor, revealing that the cleaved fragments forming this domain associate to form a stable α/β/α sandwich fold. Based on AlphaFold2 modeling, molecular dynamics simulations, and tandem mass spectrometry, we propose that a conserved Asn‐Pro bond in RsgI9 autoproteolyzes via a succinimide intermediate whose formation is promoted by a conserved hydrogen bond network holding the scissile peptide bond in a strained conformation. As other RsgI anti‐σ factors share sequence homology to RsgI9, they likely autoproteolyze through a similar mechanism.

Takayesu, Allen↗

A Survey on the Expanding Scope and Interdisciplinary Opportunities for Processing-in-Memory Techniques

Processing-in-Memory (PIM) is emerging as a practical path to overcome the limitations of traditional von Neumann architectures. At its core, PIM systems implement computing primitives such as logic operations and multiply-accumulate acceleration through compute-in-memory, near-memory processing, or hybrid designs. The role of memory cells varies widely across technologies, acting as inputs, outputs, or analog accumulators through bit-lines and sense amplifiers. This diversity creates trade-offs in precision, bandwidth, latency, and programmability, making it difficult to build a unified understanding on the progress of the field. In this survey, we organize recent advances of PIM into three areas. First, we discuss the progress on the architectural optimizations of PIM and its integration with both DRAM and emerging non-volatile memories. Second, we examine how PIM is being used to accelerate key computing domains, including generative AI workloads and high-performance kernels, along with new approaches. Third, we highlight the growing adoption of PIM in computational sciences, where it is being applied to solve interdisciplinary problems such as genome analysis, mRNA quantification, mass spectrometry, quantum circuit simulation, wave modeling, and secure computation. Finally, we synthesize the major challenges that continue to slow PIM adoption, including manufacturing constraints, power delivery, thermal reliability, data consistency, runtime and memory-management coordination, and the difficulty of building portable software abstractions without sacrificing commercial viability. This work provides an updated, structured perspective on PIM’s potential across computing and computational sciences and the barriers that must be solved for it to reach its full impact.

Asifuzzaman, Kazi [Oak Ridge National Laboratory (↗

Mechanistic Studies of a Primitive Homolog of Nitrogenase Involved in Coenzyme F430 Biosynthesis

Methyl-coenzyme M reductase (MCR) is the key enzyme in the biological formation and anaerobic oxidation of methane (AOM). Methane is a potent greenhouse gas and the major component of natural gas. Given the abundance of natural gas reserves in remote areas, there is great current interest in a scalable bio-based process for the conversion of methane to liquid fuel or other high-value commodity chemicals. MCR holds much promise for use in such a methane bioconversion strategy. However, MCR cannot currently be produced in an active form in a heterologous host, due in large part to the lack of genetic and biochemical information about the production of holo MCR. In an effort to overcome this deficiency, our laboratory elucidated the biosynthetic pathway of the unique nickel-containing coenzyme of MCR, F430. The key step in coenzyme F430 biosynthesis (Cfb) was found to involve an unprecedented reductive cyclization reaction that converts Ni-sirohydrochlorin a , c -diamide to 15,17 3 -seco-F430-17 3 -acid. This remarkable transformation, which involves a 6-electron reduction of the isobacteriochlorin ring system, cyclization of the c -acetamide side chain to form a γ-lactam ring, and the formation of 7 stereocenters, is catalyzed by a primitive homolog of nitrogenase (CfbCD). Nitrogenase is a two-component metalloenzyme that catalyzes the ATP-dependent reduction of dinitrogen to ammonia (nitrogen fixation). Homologs of nitrogenase are also involved in the biosynthesis of the photosynthetic pigments chlorophyll and bacteriochlorophyll. Phylogenetic analysis of the CfbCD complex suggests that it is representative of a more ancient lineage of the nitrogenase superfamily, and a thorough investigation of its structure and function is likely to shed light on the mechanisms and evolution of these important metalloenzymes that catalyze multi-electron redox reactions. Moreover, a detailed understanding of the mechanism of the CfbCD complex may aid in the development of specific inhibitors to help reduce natural greenhouse gas emissions and can be exploited for the heterologous production of MCR for methane bioconversion. Towards these goals, the following Specific Aims will be pursued to determine the: 1) Identity of the CfbCD reaction product. The exact reaction catalyzed by CfbCD, including the number of electrons transferred and whether it involves enzymatic cyclization, is unclear. Several approaches, including reaction stoichiometry measurements, spectroelectrochemistry, and magnetic resonance spectroscopy will be applied to elucidate the structure of the reaction product and establish whether CfbCD is a reductase or reductive cyclase. 2) Structure, conformational dynamics, and oligomerization state changes of CfbCD. Significant insight into the mechanism and allosteric regulation of CfbCD can be obtained by assessing changes in the structure and dynamics of the complex during the catalytic cycle. To accomplish this, a combination of size-exclusion chromatography, hydrogen-deuterium exchange mass spectrometry, molecular dynamics simulations, and high-resolution structural methods will be employed. 3) Source, order, and stereochemistry of proton additions during CfbCD catalysis. Details regarding the order and stereochemistry of proton additions during the CfbCD reaction will be uncovered using a combined spectroscopic and computational approach. Complementary mechanistic studies employing site-directed mutagenesis and substrate analogs will establish the identity of active site acid residues and the possible involvement of substrate-assisted catalysis during the CfbCD reaction.

09 BIOMASS FUELS↗

Accelerating Lipidomic Method Development through in Silico Simulation

Judicious selection of mass spectrometry (MS) acquisition parameters is essential for effectively profiling the broad diversity and dynamic range of biomolecules. Typically, acquisition parameters are individually optimized to maximally characterize analytes from each new sample matrix. This time-consuming process often ignores the synergistic relationship between MS method parameters, producing suboptimal results. Here in this paper, we detail the creation of an algorithm which accurately simulates LC-MS/MS lipidomic data acquisition performance for a benchtop quadrupole-Orbitrap MS system. By coupling this simulation tool with a genetic algorithm for constrained parameter optimization, we demonstrate the efficient identification of LC-MS/MS method parameter sets individually suited for specific sample matrices. Finally, we utilize the in silico simulation to examine how continued developments in MS acquisition speed and sensitivity will further increase the power of MS lipidomics as a vital tool for impactful biochemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗