Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetic target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of Fuel Cycles for Lead-Lithium and Pure Lithium Liquid Metal Walls in a Magnetized Target Fusion Power Plant

General Fusion (GF) is developing an adaptable, commercial fusion power plant based on magnetized target fusion (MTF). The GF approach involves forming a spherical torus of deuterium-tritium plasma in a large (~4 m diameter) cavity formed in liquid metal, and then collapsing that cavity with an array of pneumatic piston drivers. The liquid metal is constantly flowing through the fusion chamber and out to processing systems where tritium and heat will be extracted using tritium extraction technologies and heat exchangers, respectively. Here, this study focuses on two candidate designs for the liquid metal blanket and first wall material for the General Fusion Magnetized Target Fusion (GF MTF) power plant and assesses their impact on the tritium fuel cycle. The first candidate is the lead lithium eutectic (LLE) and the second candidate is pure lithium (Li). It was found that the main differences between LLE and Li designs are the extraction technologies required to remove tritium from the blanket and the amount of tritium and its distribution within the facility. More than 80% of the in-process tritium inventory for the LLE design is contained in the isotope separation system, while for the Li design, over 60% of the in-process tritium inventory is contained within the blanket material. This is due to significant tritium retention by Li. For the Li blanket, the burden of tritium processing rests on the blanket extraction technology rather than the traditional exhaust processing route. Thus, the blanket extraction technology is a main driver of tritium inventory in the Li system and determines the subsequent interface with the tritium processing plant.

General Fusion↗

Numerical investigation of magneto-inertial fusion targets magnetized by dynamic enforcement of helical current flow

Magnetized Liner Inertial Fusion (MagLIF) targets require premagnetization to reduce thermal conduction losses from the laser-heated fuel to the liner material during implosion. MagLIF targets are typically magnetized by external magnetic field coils which are technologically limited to providing <20 T axial magnetic fields in the fusion fuel. We present a novel target design, AutoMag-D, which employs dynamic enforcement of helical current in the liner, resulting in >20 T axial magnetic field in the fuel region prior to implosion without the need of external magnetic field coils. These self-magnetizing liners are made of helically oriented alternating electrically conductive material and electrically insulating material surrounded by a thin, conductive outer radial layer. As the liner is pulsed with a ∼ 20 MA, ∼ 100 ns rise time drive current from Z, the outer layer of conductive material is shocked and intensely Joule heated, causing it to melt, vaporize, and turn to plasma. This allows the magnetic drive field to diffuse radially inward which dynamically enforces current flow in the helical conduction paths in the liner and produces axial magnetic field in the fuel region prior to implosion of the inner liner surface. AutoMag-D liner designs do not require dielectric breakdown of electrically insulating material (as in traditional auto-magnetizing helical liners) and do not require helical return current geometries (as in dynamic screw pinches). We present results from three-dimensional radiation-magnetohydrodynamic simulations of MagLIF implosions employing AutoMag-D liner designs. Simulated AutoMag-D targets demonstrate improved fuel conditions and thermonuclear yield compared to traditional MagLIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Designs of New First Target Beamline Magnets for the ORNL SNS Upgrade

The Spallation Neutron Source (SNS) at ORNL currently is being upgraded from 1.0 GeV to 1.3 GeV. Several water-cooled magnets should be upgraded to transport 30% of higher beam energy. New chicane, injection/extraction septum, and Lambertson magnets were designed. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field do not disturb the circulating beam. The special field profiles had to be provided in foil areas between magnets. The analysis described here was based on OPERA3D simulations. A special technique was used for analyzing the integrated field harmonics. Initially, the particle track was simulated, and integrated field components were calculated along this track for the reference radius, which were used for the harmonics analysis. In addition, 3D field maps were provided for beam optics simulations. The final beamline analysis confirmed good beam transmission and low losses.

3d field maps↗

Record magnetic field generation by short-pulse laser-driven capacitor-coil targets

Magnetic fields generated by capacitor-coil targets driven by intense short-pulse lasers have been characterized using ultrafast proton radiography. A 1-kJ, 15-ps laser at a center wavelength of 1053 nm irradiated the back plate of the capacitor with an intensity of ∼8.3 × 10 18 W/cm 2 , creating ultra large currents in the connecting coils. High-quality proton data obtained in the axial probing geometry show definitive signatures of magnetic field generation, allowing precision measurement of the field distribution and strength. The data show a coil current of 120 ± 10 kA producing 200 ± 20 Tesla magnetic fields at the coil center at 1.127 ns after the laser drive. In conclusion, this sets a record for magnetic field generation by the short-pulse-powered capacitor-coil targets.

Gao, Lan [Princeton Plasma Physics Laboratory (PPP↗

Plasma Guns for Magnetized Fuel Targets for PJMIF

In plasma jet driven magneto-inertial fusion (PJMIF) an array of discrete supersonic plasma jets is used to form a spherically imploding plasma liner, which then compresses a magnetized plasma target to fusion conditions. With funding from ARPA-E’s ALPHA program and from Strong Atomics LLC, HyperJet Fusion Corp and HyperV Technologies Corp. previously developed the plasma guns required for an experimental demonstration of the plasma liner formation part of the concept. A 36-gun demonstration of an imploding spherical plasma liner is currently underway on the PLX facility at Los Alamos National Laboratory. This present project addresses the next step required for a complete PJMIF concept, i.e. developing the magnetized plasma target. We proposed to form the target by stagnating a number of magnetized plasma jets in the center of the target chamber. This is accomplished by adding a bias field coil to the plasma liner gun to form a magnetized plasma jet. This experimental development took place at HyperJet in a geometry replicating the bias field environment that will be seen on a PLX port so the results are directly transferrable to the PLX experiment. The objective of this effort was the technical development and characterization of a new magnetized plasma jet using a high-performance, high momentum flux, contoured-gap coaxial plasma gun appropriate for use on the next stage of the PLX experiment. Electromagnetic modeling of the coil indicated the coil was best placed around the aluminum tubes of the gun transmission line, rather than around the chamber port as originally proposed. This maximized field strength in the breech and yielded much better flux linkage between gun electrodes. A 30-turn coil was ultimately implemented, allowing long pulses that could diffuse through the metal walls on the timescale of interest. \machtwo modeling predicted that less capacitance in the main PFN could potentially improve plasma jet velocities due to better matching of the current to the smaller plasma mass and the existing electrode contour designed to suppress blowby. This proved true, as testing showed markedly improved performance when the original 600uF bank was reduced to 400uF. A number of diagnostics were built and/or upgraded in order to characterize the plasma jets, inluding laser interferomtery for density, photodiodes for velocity, Bdot probes for magnetic field measurements, a Triple probe for temperature measurements, and spectroscopy for impurity content. A plasma gun with the 30-turn magnet coil installed, a 70% reduction in gas valve plenum volume, and a 33% reduction in main PFN capacitance produced a dense, high velocity, well magnetized plasma jet. We met or exceeded virtually all of the plasma jet parameter goals. Peak velocity of 135 km/s exceeded the 100 km/s goal by 35%, while the peak density of over 1.0x10 15 cm -3 was 3.3 times the goal of >3.0x10 14 cm -3 . Shot-to-shot repeatability is excellent, with a jitter of less than 300ns observed on the arrival fronts of the photodiode signals from one shot to the next. Average plasma jet lengths of 33cm (at 120km/s) were slightly longer than the 20cm goal, but jets as short as 11.8cm were observed at 135km/s. Mass is much higher than the targeted goal, averaging 106ug per shot compared to 20ug. The magnetic field is still a bit lower than desired, with a maximum to date of ~811G, compared to the goal of 1000G. Average values, though, were typically in the 300-450G range, when measured further downstream after some expected in flight decay. Temperature measurements are still a work in progress. Increasing the B field and completing temperature measurements will be continued on into the ongoing BETHE project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulated thermonuclear performance of auto-magnetizing helical liner MagLIF target implosions

Magnetized liner inertial fusion (MagLIF) implosions on the Z accelerator require magnetization of the fuel to reduce thermal conduction losses of energy from the laser-preheated deuterium fusion fuel to the surrounding liner material. While external field coils traditionally used to axially magnetize MagLIF targets are limited to 10–20 T (or perhaps ∼ 30 T with technological development), calculations suggest that higher axial magnetic fields would improve thermal insulation of the fuel and improve MagLIF target performance. We present results from three-dimensional radiation-magnetohydrodynamic simulations of MagLIF implosions employing auto-magnetizing helical liners composed of discrete metallic helical conduction paths separated by electrically insulating material. These simulated auto-magnetizing (AutoMag) liners produce axial magnetic fields >30 T inside the fusion fuel prior to implosion. Simulations indicate that higher thermonuclear yields and burn-averaged fuel ion temperatures are attained for implosions using AutoMag liners compared to standard MagLIF implosions. Comparable implosion morphology is evident in synthetic x-ray images of AutoMag–MagLIF and standard MagLIF implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Amplification of laser imprint in the presence of strong, externally imposed, target-normal magnetic fields

Here, an experiment was performed on the OMEGA EP Laser System to investigate the effects of magnetic fields on laser imprint. A 30 µ⁢m thick CH target was driven by a single beam delivering 3.0 kJ of UV energy in a 5 ns square pulse without smoothing by spectral dispersion. The Rayleigh-Taylor amplification of this beam's imprint on the target surface was monitored using face-on gated x-ray radiography from a Gd backlighter. Magnetic fields of up to 45 T were applied normal to the target surface. Analysis of the resulting radiographs shows a 60 ± 13% increase in the spectrally resolved surface perturbation amplitudes, consistent at all times and for all unsaturated frequencies. This consistency indicates that the increase in perturbation amplitudes was due to a change in the initial amplitudes rather than Rayleigh-Taylor growth. This is supported by the trajectory of individual modes and the inferred time-averaged perturbation growth rates. Laser imprint is therefore inferred to have increased due to strong magnetic fields that remain in the conduction zone of the target, suppressing off-axis electron motion and limiting the effects of thermal smoothing.

direct drive↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

M-STAR: Magnetism second target advanced reflectometer at the Spallation Neutron Source

M-STAR is a next generation polarized neutron reflectometer with advanced capabilities. A new focusing guide concept is optimized for samples with dimensions down to a millimeter range. A proposed hybrid pulse-skipping chopper will enable experiments at constant geometry at one incident angle in a broad range of wavevector transfer Q up to 0.3 A –1 for specular, off-specular, and GISANS measurements. M-STAR will empower nanoscience and spintronics studies routinely on small samples (~2 × 2 mm 2 ) and of atomic-scale thickness using versatile experimental conditions of magnetic and/or electric fields, light, and temperature applied in situ to novel complex device-like nanosystems with multiple buried interfaces. M-STAR will enable improved grazing incidence diffraction measurements, as a surface-sensitive depth-resolved probe of, e.g., the out-of-plane component of atomic magnetic moments in ferromagnetic, antiferromagnetic, and more complex structures as well as in-plane atomic-scale structures inaccessible with contemporary diffractometry and reflectometry. New horizons will be opened by the development of an option to probe near-surface dynamics with inelastic grazing incidence scattering in the time-of-flight mode. These novel options in combination with ideally matched parameters of the second target station will place M-STAR in the world’s leading position for high resolution polarized reflectometry.

47 OTHER INSTRUMENTATION↗

Effects of finite material size on axion-magnon conversion

Magnetic materials are particularly favorable targets for detecting axions interacting with electrons because the collective excitation of electron spins, the magnon, can be excited through the axion-magnon conversion process. It is often assumed that only the zero-momentum uniformly precessing magnetostatic (Kittel) mode of the magnon is excited. This is justified if the de Broglie wavelength of the axion is much longer than the size of the target magnetic material. However, if the de Broglie wavelength is shorter, finite-momentum magnon modes can also be excited. We systematically analyze the target material size dependence of the axion-magnon conversion rate. We discuss the importance of these effects in the detection of relativistic axions as well as in the detection of axion dark matter of relatively heavy mass with large material size.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suppression and enhancement of electromagnetic pulses from laser–target interactions by strong magnetic fields

Laser–target interactions generate intense electromagnetic pulses (EMPs) that can interfere with measurements and damage equipment. In this paper we show that applying a magnetic field to nanosecond pulse laser–target interactions decreases the magnitude of EMPs. We demonstrate this effect in two experiments with different geometries (spherical versus planar), laser intensities ( ∼10 13 versus ∼10 15 W/cm 2 ) and applied field strength (12 versus 0.1 T) that both observed suppression of EMPs in approximately the 1 GHz band (by factors of 0.65× and 0.32×, respectively). We then observe the opposite effect at high intensities with a picosecond pulse: for planar experiments with laser intensities of approximately 10 19 W/cm 2 and magnetic fields of 6–10 T, the magnitude of EMPs is increased by a factor of 1.75×. These results provide a benchmark for models of EMP generation, but suggest that magnetic fields are not a viable solution for mitigating EMPs in the high-intensity laser facilities where they are most damaging.

electromagnetic pulse↗

CRADA Final Report: CRADA Number NFE-22-09330 with General Fusion

General Fusion is developing a magnetized target fusion (MTF) approach that involves compressing an initial magnetically confined plasma inside a cavity formed in liquid metal. This approach builds from concepts initially developed under the Linus program at the U.S. Naval Research Laboratory and combines it with advances from compact toroid experiment (CTX) and sustained spheromak plasma experiment (SSPX) in compact toroid plasmas and coaxial Marshall gun systems. Modeling the tokamak during compression is central to designing a successful MTF device. The plasma is formed by coaxial helicity injection in the General Fusion device. Immediately after formation, the plasma has a diverted tokamak configuration with a single null. As the wall moves inwards, the plasma is repelled from the conducting surface and driven inwards by currents induced by its magnetic field in the liquid metal wall. As the liquid metal closes (or bridges) the opening of the coaxial plasma injector, the magnetic field topology alters to remove the null. Due to this, the plasma moves from a diverted to a wall-limited configuration. The liquid metal liner continues to close in and change shape, reducing in radius by a factor of ten at the peak of plasma compression. A model of the MTF plasma must be able to handle this continually varying geometry, and to be predictive, it must faithfully include the real imperfections arising in the process. In this project, we pursued a Monte Carlo approach to closures for MHD by computing kinetic electron trajectories in an MHD plasma background from simulations of GF devices. This requires enhancing the capabilities of the KORC-T code for running large ensembles of kinetic trajectories by porting it to GPU architectures and enabling workflows for large ensembles on OLCF machines. With these capabilities, it is possible to produce a large library of kinetic calculations of electron orbits evolving in plasma configurations spanning the magnetic configurations and plasma density profiles, including non-axisymmetry, arising in the General Fusion’s existing PI3 spherical tokamak device. Using ensembles will capture particles passing a single point in space in a given magnetic configuration, and the entire dataset will cover a range of global magnetic field geometries. By sampling around many starting points, this dataset will capture the spatial dependence of the plasma parameters. From this large dataset, it is possible to produce a reduced model for the kinetic effects not captured in MHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of strong fields with subcritical density plasmas to study the phase transitions of magnetized warm dense matter

Warm dense matter (WDM) is a regime where Fermi degenerate electrons play an important role in the macroscopic properties of a material. Recent experiments have brought us closer to understanding unmagnetized processes in WDM, but magnetized WDM remains unexplored because kilotesla magnetic fields are required. Although there are examples of field compression generating such fields by imploding pre-magnetized targets, these existing methods give no independent control over the parameters of the magnetized plasma and result in limited laser access for sample creation and diagnosis. In this paper, numerical simulations show that kilotesla magnetic fields can be obtained by shining laser beams onto the inner surface of a cylindrical target, rather than on the outer surface. This approach relies on field compression by a low-density, high-temperature plasma, rather than a high-density, low-temperature plasma, used in the more conventional approach. With this novel configuration, the region of peak magnetic field is mostly free of plasma, hence, other beams can reach a sample placed in the region of the peak field to form WDM and diagnose it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature trends and correlation between SQUID superparamagnetic relaxometry and dc-magnetization on model iron-oxide nanoparticles

Structural properties of iron-oxide nanoparticles deeply affect their magnetic performance in many applications such as with superparamagnetic relaxometry, when employed as cell-targeted magnetic nanoparticles for in vivo diagnostics. In this work, we present a detailed characterization of model nanoparticles for this application, with an average size of ~25 nm and a narrow size dispersion (σ < 7%). Considering the intrinsic structural properties of these model nanoparticles, the study of temperature dependence and correlation between dc-magnetization and superconducting quantum interference detector-relaxometry are discussed based on known theoretical predictions and computer simulations of the magnetic dipole moment and characteristic decay constants. Furthermore, computer simulations provide support in clarifying how important the overall collective magnetization is affected by particle size dispersion, which has a direct role on sustaining the magnetic relaxation signal in the temperature range required in preclinical and clinical settings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stability of perpendicular magnetohydrodynamic shocks in materials with ideal and nonideal equations of state

Magnetized target fusion approach to inertial confinement fusion involves the formation of strong shocks that travel along a magnetized plasma. Shocks, which play a dominant role in thermalizing the upstream kinetic energy generated in the implosion stage, are seldom free from perturbations, and they wrinkle in response to upstream or downstream disturbances. In Z-pinch experiments, significant plasma instability mitigation was observed with pre-embedded axial magnetic fields. To isolate effects, in this work we theoretically study the impact of perpendicular magnetic fields on the planar shock dynamics for different equations of state. For fast magnetosonic shocks in ideal gases, it was found that the magnetic field amplifies the intensity of the perturbations when $\gamma$ > 2 or it weakens them when $\gamma$ < 2. Weak shocks have been found to be stable regardless of the magnetic plasma intensity and gas compressibility; however, for sufficiently strong shocks the magnetic fields can promote a neutral stability/SAE at the shock if the adiabatic index is higher than 1 + $\sqrt{2}$. Finally, results have been validated with numerical simulations performed with the FLASH code.

36 MATERIALS SCIENCE↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Searching for axion dark matter with array-scalable single magnon detectors

We introduce an array-scalable, magnon-based detector to search for the spin-dependent interactions of electron-coupled axion dark matter with mass in the 1−100 μ⁢eV range. These axions can excite single magnons in magnetic targets, such as yttrium iron garnet (YIG) spheres, which are subsequently sensed by the detector. In our concept, this sensing is implemented by coupling the magnons in the YIG spheres to magnetic-field-resilient single-electron charge-qubits, whose state is then interrogated with a quantum nondemolition measurement. Using standard superconducting fabrication techniques, it is possible to integrate many YIG sphere-qubit sensors, forming a large detector array. We outline the detector design and operation for our concept, and determine its sensitivity to axion dark matter. We find that using available technology can already exceed the sensitivity of previous ferromagnetic haloscopes, and further improvements in performance would search for electron-coupled axion dark matter in unexplored parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergent Magnetism with Continuous Control in the Ultrahigh-Conductivity Layered Oxide PdCoO 2

The current challenge to realizing continuously tunable magnetism lies in our inability to systematically change properties, such as valence, spin, and orbital degrees of freedom, as well as crystallographic geometry. Here, we demonstrate that ferromagnetism can be externally turned on with the application of low-energy helium implantation and can be subsequently erased and returned to the pristine state via annealing. We find that this high level of continuous control is made possible by targeting magnetic metastability in the ultrahigh-conductivity, nonmagnetic layered oxide PdCoO 2 where local lattice distortions generated by helium implantation induce the emergence of a net moment on the surrounding transition metal octahedral sites. These highly localized moments communicate through the itinerant metal states, which trigger the onset of percolated long-range ferromagnetism. The ability to continuously tune competing interactions enables tailoring precise magnetic and magnetotransport responses in an ultrahigh-conductivity film and will be critical to applications across spintronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗