Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetic probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Magnetic probe diagnostics of nonlinear standing waves and bulk ohmic electron power absorption in capacitive discharges

It is recognized that standing wave effects appearing in large-area, very-high-frequency capacitively coupled plasma (CCP) reactors cause center-high plasma non-uniformity. Using a high-frequency magnetic probe, we present a direct experimental diagnostic of the nonlinear standing waves and bulk ohmic electron power absorption dynamics in low pressure CCP discharges for different driving frequencies of 13.56, 30, and 60 MHz. The design, principle, calibration, and validation of the probe are described in detail. Spatial structures of the harmonics of the magnetic field, determined by the magnetic probe, were used to calculate the distributions of the harmonic current and the corresponding ohmic electron power deposition, providing insights into the behavior of nonlinear harmonics. At a low driving frequency, i.e. 13.56 MHz, no remarkable nonlinear standing waves were identified and the bulk ohmic electron power absorption was observed to be negligible. Here, the harmonic magnetic field/current was found to increase dramatically with the driving frequency, due to decreased sheath reactance and more remarkable nonlinear standing waves at a higher driving frequency, leading to the enhancements of the ohmic heating and the plasma density in the bulk, specifically at the electrode center. At a high driving frequency, i.e. 60 MHz, the high-order harmonic current density and the corresponding ohmic electron power absorption exhibited a similar node structure, with the main peak on axis, and one or more minor peaks between the electrode center and the edge, contributing to the center-high profile of the plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Speed Active Integrators for Magnetic Probes

This report discusses a low cost, easy to develop instrument to measure magnetic fields in pulsed solenoids used for the MagNIF pulse power system. The instrument is designed to integrate voltage signals from custom B-dot probes made from PCB inductor chips. The instrument is battery powered with ± 9V rails. Acceptable B-dot probe inputs range from mV to 20V with frequencies up to 4MHz. Details of the circuit design and practical considerations for working with high speed signals are discussed.

42 ENGINEERING↗

Revealing the effect of LiOH on forming a SEI using a Co magnetic “probe”

The solid-electrolyte-interphase (SEI) plays a critical role in lithium-ion batteries (LIBs) because of its important influence on electrochemical performance, such as cycle stability, coulombic efficiency, etc. Although LiOH has been recognized as a key component of the SEI, its influence on the SEI and electrochemical performance has not been well clarified due to the difficulty in precisely controlling the LiOH content and characterize the detailed interface reactions. Here, a gradual change of LiOH content is realized by different reduction schemes among Co(OH) 2 , CoOOH and CoO. With reduced Co nanoparticles as magnetic “probes”, SEI characterization is achieved by operando magnetometry. By combining comprehensive characterization and theoretical calculations, it is verified that LiOH leads to a composition transformation from lithium ethylene di-carbonate (LEDC) to lithium ethylene mono-carbonate (LEMC) in the SEI and ultimately results in capacity decay. This work unfolds the detailed SEI reaction scenario involving LiOH, provides new insights into the influence of SEI composition, and has value for the co-development between the electrode materials and electrolyte.

25 ENERGY STORAGE↗

Spinning Hall Probe magnetic compass

In a large range of physics and space experiments, the direction of the magnetic field needs to be determined with an accuracy on the level of one milli radian or better. We have proposed a new type of magnetic compass - a rotation-based one, which provides an alternating signal from the Hall probe proportional to the value of the magnetic field transverse to the axis of rotation. The spinning Hall probe device has been realized. Alignment of the spinning axis for a minimum (zero) value of the signal allows us to find the direction of the magnetic field. The device does not require calibration and is free of any drift problems. The measurement of the rotation axis direction was accomplished by means of a laser and a flat mirror attached to the rotor. The constructed prototype achieved an accuracy for the magnetic field direction in the experiment with the polarized He-3 target on the level of one milli radian.

Wojtsekhowski, Bogdan↗

Probing magnetic configuration-mediated topological phases via high harmonic generation in MnBi 2 Te 4

Compared to a space group, a magnetic space group is much more complex, as both magnetic structure and magnetic moment direction can change the original symmetries of materials. The interplay between space symmetry and magnetism can generate versatile novel quantum states. However, detecting these topological phases experimentally, achieved through manipulating the magnetic configuration, has been restricted. It is mainly because the intrinsic link between the theory and the available experimental technique remains elusive. Here, we show that high harmonic generation (HHG) can identify these topological quantum states. In this work, we use rhombohedral MnBi 2 Te 4 film as an example, and analyze the symmetry-dependent harmonic order and signal by combining first-principles calculations and time-dependent Liouville equation numerical computations. Our results provide a fundamental basis for using HHG to study the topological quantum phases mediated by various magnetic configurations that can be easily realized by applying an external magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast electron microscopy for probing magnetic dynamics

Abstract The spatial features of ultrafast changes in magnetic textures carry detailed information on microscopic couplings and energy transport mechanisms. Electrons excel in imaging such picosecond or shorter processes at nanometer length scales. We review the range of physical interactions that produce ultrafast magnetic contrast with electrons, and specifically highlight the recent emergence of ultrafast Lorentz transmission electron microscopy. From the fundamental processes involved in demagnetization at extremely short timescales to skyrmion-based devices, we show that ultrafast electron imaging will be a vital tool in solving pressing problems in magnetism and magnetic materials where nanoscale inhomogeneity, microscopic field measurement, non-equilibrium behavior or dynamics are involved. Graphic abstract

36 MATERIALS SCIENCE↗

Electrical readout of topological spin order in ultrathin insulators with small magnetization

Probing magnetic order in insulators with small magnetization is particularly challenging in the ultrathin limit, where magnetometry and diffraction lose sensitivity. Here, in this study, we show that topological spin order with vanishingly small magnetization can be electrically detected through an interfacial topological Hall effect in heavy-metal/magnetic-insulator heterostructures. Using Pt coupled to the canted antiferromagnetic insulator hexagonal LuFe⁢O 3 (h-LuFe⁢O 3 ) we observe an unusually large and robust Hall response arising from the transfer of real-space spin topology across the interface via magnetic proximity effect (MPE). This interfacial signal enables detection of magnetic order in h-LuFe⁢O 3 with an extremely small net magnetization (0.025 𝜇 B /Fe), corresponding to Hall-conductivity-magnetization ratio ≈ 2 V −1 , which is one to two orders of magnitude large than other MPE-induced Hall effects and anomalous Hall effects of conducting magnets. This high sensitivity allows detection of magnetic order in h-LuFe⁢O 3 down to a thickness of only 1.5 unit cells. Our results establish an interfacial Hall-based approach for electrically probing topological spin structures in ultrathin insulators and the related interfaces, enabling access to magnetic order in regimes where conventional probes fail.

Topological Hall Effect↗

Magnetic anisotropy in uranium monosulfide probed by magnetic torque measurements

We have studied the magnetic torque in uranium monosulfide (US) single crystals to explore the magnetic anisotropy in this material. Uranium monosulfide crystallizes in a cubic, NaCl-type of crystal structure and exhibits the largest magnetocrystalline anisotropy observed in cubic systems. By performing detailed torque measurements we observe a strongly anisotropic behavior in the paramagnetic phase due to crystal defects and quadrupolar pair interactions. Our studies also confirm the presence of a large anisotropy in the ferromagnetic state of the US system with the <100>, <111>, and <110> directions being the hard, easy, and intermediate axes, respectively. Furthermore, the anisotropy in the paramagnetic phase shows similar characteristics to the anisotropy observed in the ferromagnetic phase, as characterized by second and fourth rank susceptibility terms. The similarity of the anisotropic behaviors in paramagnetic and ferromagnetic phases is the consequence of strong magnetoelastic properties in this system, which possibly lead to the rhombohedral structural distortion, not only in the ferromagnetic phase but also in the paramagnetic phase (induced by applied magnetic field).

36 MATERIALS SCIENCE↗

Spinon excitations and spin correlations in the one-dimensional quantum magnet β -VOSO 4 probed by Raman spectroscopy

Fractionalized excitations such as spinons and anyons have emerged as a central theme in condensed matter physics with broad implications for superconductivity, quantum statistics, and quantum computation. The nearly ideal one-dimensional S = 1/2 system β-VOSO 4 without long-range order down to 85 mK provides a promising platform to experimentally explore such fractionalized excitations. Here, we employ Raman spectroscopy to probe magnetic excitations and the evolution of spin correlations in β-VOSO 4 . Spinon signatures are found along the chain direction, evidenced by a broad, gapless scattering continuum at low temperatures. The temperature dependence of the spinon spectral weight aligns considerably with numerical density matrix renormalization group calculations. By comparing the experimental spinon spectral weight with calculated results and evaluating the associated quantum Fisher information (QFI) therefrom, we observe a steep increase in QFI upon cooling, indicating rapidly growing correlation lengths. Our study showcases QFI as a probe of spin correlations in quantum magnets.

Wulferding, Dirk [Sejong Univ., Seoul (Korea, Repu↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Design and development of the magnetic diagnostic systems for the first operational phase of the SMART tokamak

A set of magnetic diagnostics has been designed, manufactured, and calibrated for the first operational phase of the small aspect ratio tokamak. The sensor suite comprises of Rogowski coils; 2D magnetic probes; and poloidal, saddle, and diamagnetic flux loops. Here, a set of continuous Rogowski coils has been manufactured for the measurement of plasma current and induced eddy currents in conductive elements. A set of flux loops and magnetic probes will be used as input for the reconstruction of the magnetohydrodynamic equilibrium. The quantity and position of these sensors have been verified to be sufficient with synthetic equilibrium reconstructions using the equilibrium fitting code and baseline scenarios computed with the Fiesta code. These sensors will also be used as input for the real-time control system, and magnetic probes will be used for the detection of plasma instabilities. The calibration procedure for the magnetic probes is described, and the results are shown. The signal conditioning and data acquisition systems are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

An eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the EAST tokamak in order to study the n|| evolution of lower hybrid waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n|| up to n|| =5 for 4.6GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency (IF) stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n|| of the LH wave in the scrape-off layer (SOL) has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n|| of the lower hybrid waves is about 2.1, corresponding to the main peak 2.04 of the launched n|| spectrum. The n|| deduced by the least square linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n||.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

In this study, an eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the Experimental Advanced Superconducting Tokamak (EAST) in order to study the n ∥ evolution of LH waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n ∥ up to n ∥ = 5 for 4.6 GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n ∥ of the LH wave in the scrape-off layer has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n ∥ of the LH waves is about 2.1, corresponding to the main peak 2.04 of the launched n ∥ spectrum. n ∥ deduced by the least-squares linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system, a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n ∥ .

47 OTHER INSTRUMENTATION↗

Quantum Enhanced Probes of Magnetic Circular Dichroism

Magneto-optical microscopies, including optical measurements of magnetic circular dichroism, are increasingly ubiquitous tools for probing spin-orbit coupling, charge-carrier g-factors, and chiral excitations in matter, but the minimum detectable signal in classical magnetic circular dichroism measurements is fundamentally limited by the shot-noise limit of the optical readout field. Here, a two-mode squeezed light source is used to improve the minimum detectable signal in magnetic circular dichroism measurements by 3 decibels compared with state-of-the-art classical measurements, even with relatively lossy samples like terbium gallium garnet. Furthermore, these results provide a framework for new quantum-enhanced magneto-optical microscopies that are particularly critical for environmentally sensitive materials and for low temperature measurements where increased optical power can introduce unacceptable thermal perturbations.

42 ENGINEERING↗

Development of high-performance long-pulse discharge in KSTAR

High-performance long-pulse plasma operation is essential for producing economically viable fusion energy in tokamak devices. To achieve such discharges in KSTAR, firstly, the rapid increase in the temperature of plasma-facing components was mitigated. The temperature increase of the poloidal limiter, especially, was associated with beam-driven fast ion orbit loss and the discrepancy of the equilibrium reconstructed with heated magnetic probes of signal drift. The fast ions lost to the poloidal limiter were reduced by optimizing the plasma shape and the composition of neutral beam injection (NBI). This nonlinear signal drift was successfully reduced by a new thermal shielding protector on the magnetic probes. Secondly, a lower loop voltage approach was implemented to reduce a poloidal flux consumption rate. A plasma current of 400 kA and a line-averaged electron density of ~2.0 × 10 19 m –3 were chosen by considering the L–H power threshold, fast ion orbit loss, and beam shine-through power loss for low loop voltage in KSTAR. In addition, the application of electron cyclotron heating also helped maintain the plasma with low loop voltage (~25 mV) by enhancing the NBI-driven current and achieving a high poloidal beta (β P ) state. KSTAR has achieved a long pulse (~90 s) operation with the high performance of β P $\leqslant$ 2.7, thermal energy confinement enhancement factor (H 98y2 ) ~ 1.1, and fraction of non-inductive current (f NI ) $\leqslant$ 0.96. Still, gradual degradation of the plasma performance has been observed over time in the discharges. In one of the long-pulse discharges, β P reduced by ~18% over the time of ~8τ R (current relaxation time, τ R ~5 s) and ~1067τ E,th (thermal energy confinement time, τ E,th ~45 ms). The degradation may be closely associated with weak, yet growing, and persistent toroidal Alfvén eigenmodes and their effect on fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axial proton probing of magnetic and electric fields inside laser-driven coils

In a laser-driven coil, a laser is used to eject electrons from a plate, which then draws a current through a loop. Diagnosing the field strength, geometry, and conditions within these loops has been one of the primary difficulties in fielding this type of target. In this paper, the diagnostic technique of axial proton probing with a mesh fiducial of a laser-driven coil is demonstrated. Multiple coil types were driven by a 1 ns, 1.25 kJ long pulse beam and probed several times. Here, this technique provides significantly more information than transverse probing on electric- and magnetic-field strength in the region of interest and shows in our experiment complex, non-uniform current path structures and charge distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗