Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetic equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Spaceflight Magnetic Bearing Equipped Optical Chopper with Six-Axis Active Control

This paper describes the development of an ETU (Engineering Test Unit) rotary optical chopper with magnetic bearings. An ETU is required to be both flight-like, nearly identical to a flight unit without the need for material certifications, and demonstrate structural and performance integrity. A prototype breadboard design previously demonstrated the feasibility of meeting flight performance requirements using magnetic bearings. The chopper mechanism is a critical component of the High Resolution Dynamics Limb Sounder (HIRDLS) which will be flown on EOS-CHEM (Earth Observing System-Chemistry). Particularly noteworthy are the science requirements which demand high precision positioning and minimal power consumption along with full redundancy of coils and sensors in a miniature, lightweight package. The magnetic bearings are unique in their pole design to minimize parasitic losses and utilize collocated optical sensing. The motor is of an unusual disk-type ironless stator design. The ETU design has evolved from the breadboard design. A number of improvements have been incorporated into the ETU design. Active thrust control has been added along with changes to improve sensor stability, motor efficiency, and touchdown and launch survivability. It was necessary to do all this while simultaneously reducing the mechanism volume. Flight-like electronics utilize a DSP (Digital Signal Processor) and contain all sensor electronics and drivers on a single five inch by nine inch circuit board. Performance test results are reported including magnetic bearing and motor rotational losses.

Blumenstock, Kenneth A.↗

A Spaceflight Magnetic Bearing Equipped Optical Chopper with Six-Axis Active Control

This paper describes the development of an ETU (Engineering Test Unit) rotary optical chopper with magnetic bearings. An ETU is required to be both flight-like, nearly identical to a flight unit without the need for material certifications, and demonstrate structural and performance integrity. A prototype breadboard design previously demonstrated the feasibility of meeting flight performance requirements using magnetic bearings. The chopper mechanism is a critical component of the High Resolution Dynamics Limb Sounder (HIRDLS) which will be flown on EOS-CHEM (Earth Observing System-Chemistry). Particularly noteworthy are the science requirements which demand high precision positioning and minimal power consumption along with full redundancy of coils and sensors in a miniature, lightweight package. The magnetic bearings are unique in their pole design to minimize parasitic losses and utilize collocated optical sensing. The motor is of an unusual disk-type ironless stator design. The ETU design has evolved from the breadboard design. A number of improvements have been incorporated into the ETU design. Active thrust control has been added along with changes to improve sensor stability, motor efficiency, and touchdown and launch survivability. It was necessary to do all this while simultaneously reducing the mechanism volume. Flight-like electronics utilize a DSP (Digital Signal Processor) and contain all sensor electronics and drivers on a single five inch by nine inch circuit board. Performance test results are reported including magnetic bearing and motor rotational losses.

Blumenstock, K. A.↗

A Spaceflight Magnetic Bearing Equipped Optical Chopper with Six-Axis Active Control

This paper describes the development of an ETU (Engineering Test Unit) rotary optical chopper with magnetic bearings. An ETU is required to be both flight-like, nearly identical to a flight unit without the need for material certifications, and demonstrate structural and performance integrity. A prototype breadboard design previously demonstrated the feasibility of meeting flight performance requirements using magnetic bearings. The chopper mechanism is a critical component of the High Resolution Dynamics Limb Sounder (HIRDLS) which will be flown on EOS-CHEM (Earth Observing System-Chemistry). Particularly noteworthy are the science requirements which demand high precision positioning and minimal power consumption along with full redundancy of coils and sensors in a miniature, lightweight package. The magnetic bearings are unique in their pole design to minimize parasitic losses and utilize collocated optical sensing. The motor is of an unusual disk-type ironless stator design. The ETU design has evolved from the breadboard design. A number of improvements have been incorporated into the ETU design. Active thrust control has been added along with changes to improve sensor stability, motor efficiency, and touchdown and launch survivability. It was necessary to do all this while simultaneously reducing the mechanism volume. Flight-like electronics utilize a DSP (Digital Signal Processor) and contain all sensor electronics and drivers on a single five inch by nine inch circuit board. Performance test results are reported including magnetic bearing and motor rotational losses.

Blumenstock, Kenneth A.↗

A physically unclonable function using NV diamond magnetometry and micromagnet arrays

A physically unclonable function (PUF) is an embedded hardware security measure that provides protection against counterfeiting. In this article, we present our work on using an array of randomly magnetized micrometer-sized ferromagnetic bars (micromagnets) as a PUF. We employ a 4μm thick surface layer of nitrogen-vacancy (NV) centers in diamond to image the magnetic field from each micromagnet in the array, after which we extract the magnetic polarity of each micromagnet using image analysis techniques. Finally, after evaluating the randomness of the micromagnet array PUF and the sensitivity of the NV readout, we conclude by discussing the possible future enhancements for improved security and magnetic readout.

Electromagnetism↗

Critical phenomena of the layered ferrimagnet Mn 3 Si 2 Te 6 following proton irradiation

The critical phenomena and magnetic entropy of the quasi-2D ferrimagnetic crystal, Mn 3 Si 2 Te 6 (MST), is analyzed along the easy axis (H || ab) as a function of proton irradiance. The critical exponents β and γ do not fall into any particular universality class upon proton irradiation. However, for pristine and irradiated samples, the critical exponents lie closer to mean field-like interactions; therefore, long-range interactions are presumed to be sustained in MST. The effective spatial dimensionality reveals that MST remains at d =3 under proton irradiation, whereas spin dimensionality transitions from an initial n =1 to n =2 and n =3 for 1 × 10 15 and 5 × 10 15 H + /cm 2 , indicating XY and Heisenberg interactions, respectively. The spin correlation function reveals an increase in magnetic correlations at 5 × 10 15 H + /cm 2 . Maximum change in magnetic entropy at 3 T is the largest for 5 × 10 15 H + /cm 2 at 2.45 J/kg K, in comparison to 1.60 J/kg K for pristine MST. These results intriguingly align with previous findings on MST where magnetization increased by ~50% at 5 × 10 15 H + /cm 2 , in comparison to its pristine counterpart [Martinez et al., Appl. Phys. Lett. 116, 172404 (2020)]. Magnetic entropy derived from heat capacity analysis shows no large deviations across the proton irradiated samples suggesting that the antiferromagnetic (AFM) coupling between the Mn sites is stable even after proton irradiation. This implies that magnetization is enhanced through a strengthening of the super-exchange interaction between Mn atoms mediated through Te rather than a weakening of the AFM component.

2D materials↗

Magnetic field sensors for detection of trapped flux in superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are fundamental building block of modern particle accelerators. They operate at liquid helium temperatures 2-4 K to achieve very high quality factors 1e10-1e11. Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors and the fundamental components of such diagnostic tool are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors and flux-gate magnetometers with respect to their sensitivity and capability to detect localized, low magnetic flux amplitudes, of the order of few tens of magnetic flux quantum at liquid helium temperature. Although Hall probes have the lowest magnetic field sensitivity (~96$ nV$/microT at 2 K), their physical dimensions are such that they have the ability to detect the lowest number of trapped vortices among the three type of sensors. Hall probes and anisotropic magnetoresistive sensors have been selected to be used in a setup to map regions of trapped flux on the surface of a single-cell SRF cavity.

47 OTHER INSTRUMENTATION↗

Diagnosing magnetic fields in cylindrical implosions with oblique proton radiography

Two experiments at the OMEGA Laser System used oblique proton radiography to measure magnetic fields in cylindrical implosions with and without an applied axial magnetic field. Although the goal of both experiments was to measure the magnitude of the compressed axial magnetic field in the core of the implosion, this field was obfuscated by two features in the coronal plasma produced by the compression beams: an azimuthal self-generated magnetic field and small length scale, high-amplitude structures attributed to collisionless effects. In order to understand these features, synthetic radiographs are generated using fields produced by 3D HYDRA simulations. These synthetic radiographs reproduce the features of the experimental radiographs with the exception of the small-scale structures. A direct inversion algorithm is successfully applied to a synthetic radiograph but is only partially able to invert the experimental radiographs in part because some protons are blocked by the field coils. The origins of the radiograph features and their dependence on various experimental parameters are explored. Furthermore, the results of this analysis should inform future measurements of compressed axial magnetic fields in cylindrical implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Element-specific first order reversal curves measured by magnetic transmission x-ray microscopy

The first-order reversal curve (FORC) method is a macroscopic measurement technique that can be used to extract quantitative and microscopic properties of hysteretic systems. Using magnetic transmission x-ray microscopy (MTXM), local element-specific FORC measurements are performed on a 20 nm thick film of CoTb. The FORCs measured with microscopy reveal a step-by-step domain evolution under the magnetic field cycling protocol and provide a direct visualization of the mechanistic interpretation of FORC diagrams. They are compared with magnetometry FORCs and show good quantitative agreement. Furthermore, the high spatial resolution and element-specific sensitivity of MTXM provide new capabilities to measure FORCs in small regions or specific phases within multicomponent systems, including buried layers in heterostructures. The ability to perform FORCs on very small features is demonstrated with the MTXM-FORC measurement of a rectangular microstructure with vortex-like Landau structures. This work demonstrates the confluence of two uniquely powerful techniques to achieve quantitative insight into nanoscale magnetic behavior.

36 MATERIALS SCIENCE↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

Inverse aspect-ratio expanded tokamak equilibria

Following Greene et al. [Phys. Fluids 14, 671 (1971)] and Connor et al. [Phys. Plasmas 31, 577 (1988); Plasma Phys. Control. Fusion 34, 161 (1992); and Nucl. Fusion 33, 1533 (1993)], the Grad-Shafranov equation for an axisymmetric tokamak plasma equilibrium is solved via an expansion in the, supposedly small, inverse aspect-ratio of the plasma, ϵ. The displacements of equilibrium magnetic flux-surfaces due to plasma shaping are assumed to be $\mathcal{O}$(ϵ) smaller than the minor radii of the surfaces, but no other restriction is placed on the nature of the shaping. The solution of the Grad-Shafranov equation is matched to a vacuum solution that extends to infinity, and consists of an expansion in toroidal functions. The external poloidal magnetic field generated by a finite set of discrete external poloidal magnetic field-coils is calculated, and incorporated into the toroidal function expansion. In this manner, the shape of a large aspect-ratio tokamak plasma is directly related to the currents flowing in the external poloidal field-coils. Finally, a pedestal in the plasma pressure, and the associated spike in the bootstrap current, are incorporated into the model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic bearing and motor

A magnetic bearing for passively suspending a rotatable element subjected to axial and radial thrust forces is disclosed. The magnetic bearing employs a taut wire stretched along the longitudinal axis of the bearing between opposed end pieces and an intermediate magnetic section. The intermediate section is segmented to provide oppositely directed magnetic flux paths between the end pieces and may include either an axially polarized magnets interposed between the segments. The end pieces, separated from the intermediate section by air gaps, control distribution of magnetic flux between the intermediate section segments. Coaxial alignment of the end pieces with the intermediate section minimizes magnetic reluctance in the flux paths endowing the bearing with self-centering characteristics when subjected to radial loads. In an alternative embodiment, pairs of oppositely wound armature coils are concentrically interposed between segments of the intermediate section in concentric arcs adjacent to radially polarized magnets to equip a magnetic bearing as a torsion drive motor. The magnetic suspension bearing disclosed provides long term reliability without maintenance with application to long term space missions such as the VISSR/VAS scanning mirror instrument in the GOES program.

Studer, P. A.↗

Broadband NMR relaxometry of electrolytes for energy storage

An increasing use of the fast field cycling nuclear magnetic resonance relaxometry technique to investigate dynamics in electrolytes for energy storage has been evidenced during the last decade. Therefore, this review article describes some of the research carried out on electrolytes during the last ten years using this technique. These studies include various types of liquid electrolytes, such as ionic liquids and deep eutectic solvents, semi-solid-state electrolytes, in particular ionogels and polymer gels, and solid electrolytes such as glasses, glass ceramics and polymers. Here, an extended description of the different models used to explain the relaxation rate profiles is presented throughout this article.

25 ENERGY STORAGE↗

Hinged, Magnetic Holder For Radiographic Film

Hinged holder equipped with magnets enables positive, accurate, and repeatable placement and orientation of radiographic film at hidden and otherwise inaccessible location. Made from simple, readily available parts. Film and holder inserted in end of duct and pulled along by magnets on outside. Holder removed by reversing sequence of motions.

Pierce, Darryl E.↗

Method of reducing time base error in digital magnetic recorders

Apparatus reduces Time Base Error /TBE/ in the playback of digital data from magnetic recording equipment. The apparatus uses a magnet which employs a servo position control of the tape by which the playback data clock is phase locked with a fixed frequency reference signal.

Moore, J. M.↗

Magnetic bearing turbomachinery case histories and applications for space related equipment

The concept of magnetic levitation is not a new one and can be easily traced back to the 1800's. It is only recently, however, that the congruous technologies of electronic control systems, power electronics, and magnetic materials have begun to merge to make the magnetic suspension device a viable product. A brief overview of an active magnetic bearing technology is provided. Case histories of various turbomachinery in North America presently operating on magnetic bearings are reviewed. Finally, projections are made as to the space related machinery that may be benefited by incorporating magnetic bearings into the equipment design.

Weise, David A.↗

Facility Measures Magnetic Fields

Partly automated facility measures and computes steady near magnetic field produced by object. Designed to determine magnetic fields of equipment to be installed on spacecraft including sensitive magnetometers, with view toward application of compensating fields to reduce interfernece with spacecraft-magnetometer readings. Because of its convenient operating features and sensitivity of its measurements, facility serves as prototype for similar facilities devoted to magnetic characterization of medical equipment, magnets for high-energy particle accelerators, and magnetic materials.

Honess, Shawn B.↗

Improved Voice-Coil Actuators Have Lower Copper Losses

Improved design concept for electromagnetic linear-motion actuators of loudspeaker-voice-coil type reduces both copper losses (dissipation of power in electrical resistances of windings) and magnetic interference with other equipment. Includes closed magnetic circuit, which suppresses fringing flux. Pr/Fe/B permanent magnets yield better performance at lower temperatures. Intended for use where power supplies limited, heating must be minimized, and/or adequate performance at temperatures far below ambient required.

Simizu, Satoru↗