Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetic devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Magnetic Device Design and Evaluation Capabilities at JPL

This viewgraph presentation describes the magnetic device design and evaluation capabilities at the Center for Space Microelectronics Technology at the Jet Propulsion Laboratory. The capabilities start with supercomputers for design and simulation. Circuits can be examined via electrical flow and microscopic examination. These capabilities are useful for developing new devices, particularly for space applications.

microelectronics chip testing magnetic devices↗

Magnetic display devices

Magnetic display devices covering magneto-optical displays, magnetic-electrostatic technique combinations and ferromagnetography

Sinnott, R. C.↗

Simple Magnetic Device Indicates Thickness Of Alloy 903

Handheld device called "ferrite indicator" orginally designed for use in determining ferrite content of specimen of steel. Placed in contact with specimen and functions by indicating whether magnet attracted more strongly to specimen or to calibrated reference sample. Relative strength of attraction shows whether alloy overlay thinner than allowable.

Long, Pin Jeng↗

Tunable Magnetic Resonance in Microwave Spintronics Devices

Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

Microwave Detectors↗

Tunable Magnetic Resonance in Microwave Spintronics Devices

Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe-based tunable microwave spintronics devices, which is 10X higher than conventional methods.

Microwave Detectors↗

Overview of magnetic bearing control and linearization approaches for annular magnetically suspended devices

An overview of magnetic bearing control and linearization approaches which have been considered for annular magnetically suspended devices is presented. These devices include the Annular Momentum Control Device and the Annular Suspension and Pointing System. Two approaches were investigated for controlling the magnetic actuator. One approach involves controlling the upper and lower electromagnets differentially about a bias flux. The bias flux can either be supplied by permanent magnets in the magnetic circuit or by bias currents. In the other approach, either the upper electromagnet or the lower electromagnet is controlled depending on the direction of force required. One advantage of the bias flux is that for small gap perturbations about a fixed operating point, the force-current characteristic is linear. Linearization approaches investigated for individual element control include an analog solution of the nonlinear electromagnet force equation and a microprocessor-based table lookup method.

Groom, N. J.↗

Elastomeric actuator devices for magnetic resonance imaging

The present invention is directed to devices and systems used in magnetic imaging environments that include an actuator device having an elastomeric dielectric film with at least two electrodes, and a frame attached to the actuator device. The frame can have a plurality of configurations including, such as, for example, at least two members that can be, but not limited to, curved beams, rods, plates, or parallel beams. These rigid members can be coupled to flexible members such as, for example, links wherein the frame provides an elastic restoring force. The frame preferably provides a linear actuation force characteristic over a displacement range. The linear actuation force characteristic is defined as .+-.20% and preferably 10% over a displacement range. The actuator further includes a passive element disposed between the flexible members to tune a stiffness characteristic of the actuator. The passive element can be a bi-stable element. The preferred embodiment actuator includes one or more layers of the elastomeric film integrated into the frame. The elastomeric film can be made of many elastomeric materials such as, for example, but not limited to, acrylic, silicone and latex.

Dubowsky, Steven↗

Measurement of irregularities in angular velocities of rotating assemblies in memory devices on magnetic carriers

Problems in measurement of irregularities in angular velocity of rotating assemblies in memory devices with rigid and flexible magnetic data carriers are discussed. A device and method for determination of change in angular velocities in various frequency and rotation rate ranges are examined. A schematic diagram of a photoelectric sensor for recording the signal pulses is provided. Mathematical models are developed to show the amount of error which can result from misalignment of the test equipment.

Virakas, G. I.↗

Measurements of Beam Coupling in the Marshall Magnetic Mirror Device

Experimental investigations of the coupling of an electron beam into a magnetically confined plasma have been undertaken at the Marshall Space Flight Center using the Marshall Magnetic Mirror (M3) system. The M3 system is composed of the following: two magnet coils; a cylindrical vacuum vessel; microwave source; and electron beam source. The magnet coils, which form the magnetic mirror, have an inner diameter of 25.4 cm and an outer diameter of 50.8 cm. The coils are composed of 9 coil segments with 33 turns in each segment. Each coil segment is connected in series. To create the target plasma, a 2 kW microwave source (2.45 gHz) is coupled into the vacuum chamber via waveguide. The electron beam source is a hollow cathode device created by the EPL Corporation. The hollow cathode is capable of producing a 50 amp beam with a pulse length of 1 second. It is also capable of continuous operation at 5 amps. The hollow cathode is mounted on one end of the cylindrical vacuum vessel 24 cm outside of a magnet coil. A current sensor is placed in the hollow cathode keeper bias circuit to measure emission current.

Schneider, T. A.↗

Superconducting magnets and devices for space vehicles and experiments

Superconductivity research has been oriented toward those problems that tend to restrict the greater application of superconducting devices in space research and technology. These include magnetic problems of high field magnets, increasing operating temperatures, and development of useful competitive superconducting instruments.

Urban, E. W.↗

Finite element modelling of non-linear magnetic circuits using Cosmic NASTRAN

The general purpose Finite Element Program COSMIC NASTRAN currently has the ability to model magnetic circuits with constant permeablilities. An approach was developed which, through small modifications to the program, allows modelling of non-linear magnetic devices including soft magnetic materials, permanent magnets and coils. Use of the NASTRAN code resulted in output which can be used for subsequent mechanical analysis using a variation of the same computer model. Test problems were found to produce theoretically verifiable results.

Sheerer, T. J.↗

Investigation of fluctuations in angular velocity in magnetic memory devices

The fluctuations in the angular velocity of individual assemblies of a precision mechanical system were analyzed. The system was composed of an electric motor and a magnetic drum which were connected by a flexible coupling. A dynamic model was constructed which took into account the absence of torsion in the rigid shafts of the electric motor drive rotor and the magnetic drum. The motion was described by Lagrange differential equations of the second kind. Curves are developed to show the nature of amplitude fluctuation of the magnetic drum angular velocity at a specific excitation frequency. Additional curves show the amplitudes of fluctuation of the magnetic drum angular velocity compared to the quantity of damping at specific frequencies.

Meshkis, Y. A.↗

High Curie temperature drive layer materials for ion-implanted magnetic bubble devices

Ion implantation of bubble garnets can lower the Curie temperature by 70 C or more, thus limiting high temperature operation of devices with ion-implanted propagation patterns. Therefore, double-layer materials were made with a conventional 2-micron bubble storage layer capped by an ion-implantable drive layer of high Curie temperature, high magnetostriction material. Contiguous disk test patterns were implanted with varying doses of a typical triple implant. Quality of propagation was judged by quasistatic tests on 8-micron period major and minor loops. Variations of magnetization, uniaxial anisotropy, implant dose, and magnetostriction were investigated to ensure optimum flux matching, good charged wall coupling, and wide operating margins. The most successful drive layer compositions were in the systems (SmDyLuCa)3(FeSi)5O12 and (BiGdTmCa)3(FeSi)5O12 and had Curie temperatures 25-44 C higher than the storage layers.

Fratello, V. J.↗

Six micrometer period wide-gap permalloy magnetic bubble devices

This report describes the progress made toward the goal of developing a 1 Mbit bubble memory chip, based on a 6 micron period wide-gap permalloy technology. Characterization of the functions showed that the guard-rail, generator, swap, write-line, read-line and after several revisions, the replicator and the expander-detector performed acceptably in preliminary testing. Several investigations were initiated to solve the problem of low minor loop yield. A dual-spacing process, which allows the minor loop propagation elements to be more tightly coupled to the garnet film was developed. Several new propagate structures, intended to be more tolerant of small defects were also conceived.

Chirovsky, L. M. F.↗