ISIS-B spacecraft magnetic tests

Magnetic tests of the ISIS B spacecraft were conducted to determine the various magnetic moments of the spacecraft, evalute its spin and attitude control systems, and calibrate the six onboard magnetometer probes. Test procedures and equipment are described. Techniques for evaluting the data are discussed, and test results are presented. The spacecraft's magnetic characteristics were found to be satisfactory. Proper threshold values for gating the torquing coils were obtained. The onboard magnetometers were satisfactorily calibrated.

Boyle, J. C.↗

UK-4 flight spacecraft magnetic tests

Magnetic tests conducted on the UK-4 spacecraft are discussed. The objectives of the test are: (1) to determine the permanent, induced, and stray magnetic moments of the spacecraft, (2) to assess its magnetic stability, (3) to determine the dipole moment produced by energizing the magnetorquer coil, (4) to measure the despin torque due to eddy current and magnetic hysteresis, and (5) to deperm, compensate, and make other adjustments necessary to achieve satisfactory magnetic characteristics for the spacecraft.

Pruett, W. E.↗

SAS-A spacecraft magnetic tests

Magnetic tests were conducted on the spacecraft for: (1) alignment, compensation, calibration, and bias determination for the spacecraft three-axis vector magnetometer; (2) determination of permanent, induced, and stray magnetic moments of the spacecraft and compensation of permanent magnetic moments by permanent magnets; and (3) evaluation of the spin and attitude control system.

Boyle, J. C.↗

Magnetic testing

Magnetic techniques are described for the nondestructive evaluation of defects in materials. The physical principles, and the magnetic-particle method are discussed along with magnetic-hysteresis measurements and electric current perturbations.

Pasley, R. L.↗

Lunar roving vehicle magnetic tests

The qualification model of the lunar roving vehicle (LRV) was tested in the Spacecraft Magnetic Test Facility (SMTF) at the GSFC Magnetic Test Site. Magnetic field measurements were made, both with the vehicle in its as received state and also subsequent to final deperm treatment. These measurements, together with information supplied to GSFC regarding the magnetic moment of the astronaut's extravehicular mobility units (EMU's) were used to calculate 0.5 nanotesla (gamma) contours around the LRV. The results are tabulated. Magnetic field measurements were also made with various items of LRV equipment operational. No significant changes were noted, except during operation of the vehicle wheels.

Boyle, J. C.↗

UK-4 prototype spacecraft magnetic tests

The spacecraft was tested in a magnetic test facility which uses a 42 ft. diameter coil system to produce a controlled magnetic field of high uniformity over a large central volume. The primary objectives of the tests were: (1) to determine the permanent, induced, and stray magnetic moments of the spacecraft and to assess its magnetic stability; (2) to evaluate the magnetorquer coil system; and (3) to deperm, compensate, and make other adjustments necessary to achieve satisfactory magnetic characteristics for the spacecraft. The test facility and procedures are described together with the results obtained. In addition, the problems encountered during the tests and the significance of the test findings are discussed.

Pruett, W. E.↗

SSA-A spacecraft magnetic tests

In the initial magnetic tests the spacecraft perm moment as received was 43 milliampere-meter squared (pole-cm), which was reduced by deperm treatment to milliampere-meter squared. Facility fluxgate probe bias results indicated Z axis bias at the SSS-A fluxgate magnetometer position to be about one half nanotesla (gamma) after Z axis deperm. The ASCS magnetometers, 01 and 02, were successfully aligned and proper operation of the ASCS system were verified. The spacecraft fluxgate magnetometer was calibrated in both the high and low sensitivity modes after a defective 01 electronics card was replaced. Problems were encountered in the Z axis search coil during calibration and the test was re-scheduled. Final test results indicated that the total perm moment could not be reduced any lower than 35 milliampere-meter squared by deperm treatment. However, the Z axis moment decreased from 22 milliampere-meter squared to 6 milliampere-meter squared after deperm. Correct operation and calibration was verified for all three axes of the spacecraft fluxgate magnetometer and no significant bias was observed during stray field testing. Null and spot calibration of the ASCS magnetometer was completed and the measured spin and attitude coil moments were: 2535 and 9820 milliampere-meter squared respectively.

Roy, T. N.↗

Magnetic Test Performance Capabilities at the Goddard Space Flight Center as Applied to the Global Geospace Science Initiative

Goddard Space Flight Center's (GSFC) Spacecraft Magnetic Test Facility (SMTF) is a historic test facility that has set the standard for all subsequent magnetic test facilities. The SMTF was constructed in the early 1960's for the purpose of simulating geomagnetic and interplanetary magnetic fields. Additionally, the facility provides the capability for measuring spacecraft generated magnetic fields as well as calibrating magnetic attitude control systems and science magnetometers. The SMTF was designed for large, spacecraft level tests and is currently the second largest spherical coil system in the world. The SMTF is a three-axis Braunbek system composed of four coils on each of three orthogonal axes. The largest coils are 12.7 meters (41.6 feet) in diameter. The three-axis Braunbek configuration provides a highly uniform cancellation of the geomagnetic field over the central 1.8 meter (6 foot) diameter primary test volume. Cancellation of the local geomagnetic field is to within +/-0.2 nanotesla with a uniformity of up to 0.001% within the 1.8 meter (6 foot) diameter primary test volume. Artificial magnetic field vectors from 0-60,000 nanotesla can be generated along any axis with a 0.1 nanotesla resolution. Oscillating or rotating field vectors can also be produced about any axis with a frequency of up to 100 radians/second. Since becoming fully operational in July of 1967, the SMTF has been the site of numerous spacecraft magnetics tests. Spacecraft tested at the SMTF include: the Solar Maximum Mission (SMM), Magsat, LANDSAT-D, the Fast Aurora] Snapshot (FAST) Explorer and the Sub-millimeter-Wave-Astronomy Satellite (SWAS) among others. This paper describes the methodology and sequencing used for the Global Geospace Science (GGS) initiative magnetic testing program in the Goddard Space Flight Center's SMTF. The GGS initiative provides an exemplary model of a strict and comprehensive magnetic control program.

Mitchell, Darryl R.↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote earth field sensing magnetometer and servo control building; and a remote power control and instrumentation building. The inner coils are 42-foot in diameter and a 10-foot by 10-foot opening through the outer coils accommodates spacecraft access to the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions ground testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground-testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

Design of the cryostat for High Field Vertical Magnet Testing Facility at Fermilab

High Field Vertical Magnet Test Facility (HFVMTF) is a joint project between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). Its construction is currently under way at Fermi National Accelerator Laboratory (Fermilab). As a part of the project a new double bath superfluid helium cryostat has been designed. The cryostat can accommodate magnets with up to 20 tonne weight and 1.3 m diameter. This paper discusses challenges and solutions for cryostat, lambda plate and heat exchanger design, and presents results of performance analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗