Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “luminaires”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heat sink for luminaire and luminaire arrangements having a heat sink

A heat sink for a luminaire includes a central portion having a top surface and a bottom surface. The bottom surface is adapted to receive a lighting arrangement. The heat sink further includes a plurality of arms configured to dissipate heat generated by the lighting arrangement. The plurality of arms extend radially outward from the central portion. Each one of the plurality of arms is substantially arcuate between a proximal end and a distal end.

Trublowski, John↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing multichannel luminaire control using a color efficient matrix

The described embodiments relate to multichannel luminaires (102, 212, 404) that employ a color coefficient matrix (CCM) that can be used to adjust an operation of the multichannel luminaires according to their contribution of light to an area (112, 402). The CCM can be generated based on images captured within the area and/or a software simulation that approximates the contribution of light from the multichannel luminaires to the area. Once the CCM has been generated, the CCM can be used to compensate control signals to each multichannel luminaire in order to provide more accurate color rendering and uniform light distribution. Furthermore, feedback from embedded sensors (206) in the multichannel luminaires and/or sensors (116, 208, 210, 418) in the area can provide further basis for compensating control signals according to the qualities of the natural and artificial light entering the area, and the effects of different surfaces (128) on the light.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adjustable-beam luminaires

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Adjustable-beam luminaires with automatic beam controller

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Adjustable-beam luminaire

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Adjustable-beam luminaires

A luminaire for providing configurable static lighting or dynamically-adjustable lighting. The luminaire uses an array of focusing elements that act on light provided via a corresponding array of sources or via an edge-lit lightguide. Designs are provided for adjusting the number of distinct beams produced by the luminaire, as well as the angular width, angular profile, and pointing angle of the beams. Designs are also provided for systems utilizing the adjustable luminaires in various applications.

Gladden, Christopher↗

Additively Manufactured Solid-State Luminaire

This project addresses several key barriers to wide-spread adoption of additive manufacturing (AM) technology as applied to solid state lighting luminaires. The solution will utilize cutting edge AM approaches for integrating structure with thermal management solutions, electronic functionality, and optics. The research team (Eaton, Lighting Research Center (LRC) at Rensselaer Polytechnic Institute, Xerox Research Centre of Canada (XRCC)) utilize their AM and lighting expertise to investigate breakthrough manufacturing approaches that will significantly reduce cost, eliminate manufacturing process waste, and improve luminaire efficacy. The team has identified critical areas of research and proposed novel technical approaches to achieve these goals. Key areas of focus in Budget Period 1 (BP1) of the project quantified the impact of applying AM methodologies to the main, discrete subsystem components (Heat Sink, Housing, Optics, Electronics). Budget Period 2 (BP2) research explored similar impact on a fully integrated, AM modular luminaire concept. Final Achievement of the Target Metrics for the project are as follows: Material Reduction: achieved > 57.45% (target is 50%) Manufacturing Process: achieved > 51% reduction (target is 50%) Application Efficacy: achieved 126 lm/W (target is 130 lm/W) First Cost vs Baseline: demonstrated 49% improvement in project timing, 59% improvement in man hour savings and 89% worse BOM costs (due to deficiencies in current “state of the art” equipment). The BOM costs improve to 53% savings if state of the art processes and equipment could have been used.

3D Printing↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Composite luminaire

A luminaire includes a core made up of a first material and an LED lighting arrangement mounted to the core. The luminaire further includes a housing made up of a second material. The second material is different from the first material. The housing including a recess in which the core is received. The housing further includes a finned part.

Santiago Baerga, Jeremy M.↗

A Case Study of Luminaire-Level Lighting Control: Lighting the Northwest Energy Efficiency Alliance (NEEA) Office in Portland, OR

What happens when advanced lighting and control systems are installed in the real world? Are the advantages and energy savings realized? By observing the design, installation, commissioning, and ongoing use of connected lighting systems in real-world settings, it is possible to identify the strengths, challenges, and points of human-technology interaction that may be new or unfamiliar to those responsible for implementing or maintaining the lighting system. Ultimately, understanding and experiencing each stakeholder’s interaction with the technology can allow the research team to synthesize feedback for manufacturers, improve industry understanding of the technology, and increase adoption. The Northwest Energy Efficiency Alliance (NEEA) office in Portland, OR, is a single-floor installation that puts tunable-white, interoperability, and luminaire-level advanced control capabilities to the test. Compared to simpler, “out-of-the-box” systems that minimize field-adjustable settings, the system utilized in this space allowed for granular field adjustments which required the system specifier, client, and programming agent to make additional decisions regarding system operation while the system was being programmed. This report communicates the observational findings from the installation, programming, and ongoing operation of an advanced office LLLC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Luminaire Design and Local Manufacturing for Highly Efficient, Customized Lighting Solutions

In response to the growing demand for tailorable and energy-efficient lighting solutions, Eaton and partners Synopsys and Rensselaer Polytechnical Institute were funded to develop an automated luminaire design method that was capable of achieving best in class efficiency while being locally manufactured at an affordable cost. This program was broken into four key technology areas, automated optics design, additively manufactured optical material characterization, printed electronics, and additively manufactured mechanical components.

99 GENERAL AND MISCELLANEOUS↗

Examining Perceptual Luminance Uniformity of Simulated Luminaire Patterns

Luminaire luminance uniformity is an important aspect that can affect perceived lighting quality, discomfort glare, and efficacy. While several metrics have been proposed to characterize luminance uniformity, previous studies have shown that current metrics such as Max:Min or Avg:Min luminance ratios can be insensitive to important differences in luminance gradient that may affect perceived uniformity. In an attempt to resolve this issue, previous studies incorporated a contrast sensitivity function for the human eye based on spatial frequency, such as in the UHVS metric; however, this metric has not been comprehensively studied in relation to perceived uniformity ratings. The study presented in this paper aimed to examine the relationship between the UHVS metric and perceived uniformity ratings. Specifically, the study used a web-based questionnaire that presented simulated luminance patterns and asked participants to assess uniformity using a two-alternative forced-choice procedure. Responses were collected and analyzed from 94 participants. The results showed a significant correlation and relationship between the UHVS metric and perceived uniformity. However, comparisons between patterns that had similar UHVS and between patterns that had larger differences in UHVS did not yield consistent results. These results suggest that the UHVS metric might be used for general guidance but may warrant further studies to better understand its sensitivity and improve its alignment with perceived uniformity ratings.

Abboushi, Belal K.↗

Round 3 Update of Stress Testing Results for Organic Light-Emitting Diode Panels and Luminaires

Organic light-emitting diode (OLED) sources are a potential solid-state lighting technology for use in indoor lighting applications. Some of the advantages offered by OLEDs include thin profiles, low glare, diffuse lighting, and unique form factors. The U.S. Department of Energy (DOE) has released six technical reports focused on OLED technologies to provide information and analysis to the lighting industry. These reports include the evaluation of two different field deployment sites, a market analysis, a tear-down analysis, and two independent assessments of the performance of select commercially available OLED products. This report builds on earlier DOE efforts with OLED technology by updating information about previously benchmarked commercial OLED products. Specifically, this report provides updated findings about the robustness and reliability of commercial OLED products.

42 ENGINEERING↗