Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low-level laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Mammalian complex III heme dynamics studied with pump-probe spectroscopy and red light illuminations

The electronic or molecular mechanisms which initiate photobiomodulation (PBM) in cells are not yet fully understood. Porcine complex III (C-III) of the electron transport chain was characterized with transient absorption spectroscopy (TAS). Then we applied our recently developed continuous wave laser coupled TAS procedure (CW-TAS) to investigate the effect of red light irradiances on the heme dynamics of C-III in its c 1 reduced state. The time constants associated with the axial ligand photodissociation were found to be 3.3 ± 0.3 ps for the oxidized state and 4.9 ± 0.4 ps for the c 1 reduced state. The analysis of the CW-TAS procedure yielded no significant changes in the C-III heme dynamics. We rule out the possibility of 635 nm CW light at 4.7 mW/cm 2 inducing a PBM effect on the heme dynamic of C-III, specifically with the photodissociation of its axial ligand.

59 BASIC BIOLOGICAL SCIENCES↗

Transient absorption spectroscopy to explore cellular pathways to photobiomodulation

Photobiomodulation (PBM) describes the use of low irradiance light in the red to near-infrared wavelength range to stimulate biological effects in tissue, and many biological and spectroscopic techniques are used to study PBM. However, these techniques focus on the products or downstream effects rather than the electronic transitions that initiate the PBM processes. This study presents a novel approach to studying low irradiance light exposures on individual proteins and/or protein complexes by combining a continuous wave (CW) laser diode with femtosecond transient absorption spectroscopy (TAS), coined here as CW-TAS, and tests the system on reduced cytochrome c (Cyt c) for proof of principle. TAS was conducted using a 532-nm excitation pump beam and a 350-600 nm supercontinuum probe. In this work, CW laser diodes with wavelengths of 450 nm, 635 nm, and 808 nm were interchangeably fiber coupled into the HELIOS Fire. Samples of Cyt c were tested by TAS using a pump power of 15 µW, both with and without CW exposure. CW exposures were carried out with irradiances of 1.60 and 3.20 mW/cm 2 , except for 808 nm, which was only tested at 1.60 mW/cm 2 . Both kinetic and global analyses were performed on the TAS data and the time constants for sets with and without CW exposures were compared. The TAS data for Cyt c with the full dosage of CW exposures did not alter the TAS data distinguishably from the control data. No new electronic transient signals were observed beyond the background when testing Cyt c with the CW exposures. Kinetic analysis confirmed that existing transients did not deviate beyond uncertainty. Global time constants for Cyt c were calculated to be 0.25 ± 0.03 ps and 5.1 ± 0.3 ps for the control study, and the time constants for the CW exposed Cyt c were not significantly different. This study concludes that CW irradiation, at doses delivered, does not alter the transient absorption data of Cyt c. The CW-TAS method provides a new tool for studying PBM effects in other proteins and protein complexes, such as Complex IV, in future studies.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Multi phenomena melt pool sensor data fusion for enhanced process monitoring of laser powder bed fusion additive manufacturing

Finding actionable trends in laser-based metal additive manufacturing process monitoring data is challenging owing to the diversity and complexity of the underlying physical interactions. A single monitoring solution that captures a particular process phenomenon, such as a photodiode that tracks melt pool intensity, is not alone capable of evaluating process stability or detecting flaw formation with sufficient precision for routine application in industry. In this work, to improve flaw detection performance, we adopted a data fusion approach that captures multiple process phenomena. To demonstrate this, we acquired data from laser powder bed fusion (LPBF) builds of cylindrical specimens produced with different laser spot sizes, emulating defocusing due to process faults such as thermal lensing. The resulting specimens had porosity of varying types and severity, quantified by post-build non-destructive X-ray computed tomography, Archimedes density measurements, and destructive metallographic characterization. During the build, the melt pool state was monitored with two coaxial high-speed video cameras and a temperature field imaging system. Physically intuitive low-level melt pool signatures, such as melt pool temperature, shape and size, and spatter intensity were extracted from this high-dimensional, image-based sensor data. These process signatures were subsequently used as input features in relatively simple machine learning models, such as a support vector machine, which were trained to detect laser defocusing, and in addition, predict porosity type and severity. The results show that the data fusion approach significantly enhanced system performance by reducing the overall false positive rate from ~ 0.1 to ~ 0.001 without sacrificing the true positive rate (~0.90). These results were at par with a black-box, deep machine learning approach (convolutional neural network).

36 MATERIALS SCIENCE↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A comparative study of multimodal data fusion strategies for planetary spectroscopy

Integrating heterogeneous data sources can improve scientific inference when different modalities capture complementary information, but doing so is challenging in high-dimensional, small-sample settings. In spectroscopy for planetary exploration, Laser-Induced Breakdown Spectroscopy (LIBS), Raman Spectroscopy (Raman), Visible Infrared Spectroscopy (VISIR), and Mid-Infrared Spectroscopy (MIR) each examine different aspects of composition and mineralogy, raising fundamental questions about when and how data fusion improves predictive performance. Using a Mars-relevant set of geologic standards with measurements from all four modalities, we present a rigorous systematic evaluation of four data fusion strategies: low-level (data) fusion, mid-level (feature) fusion, high-level (decision) fusion, and residual-boosting (sequential) fusion. We assess performance in predicting oxide composition via nested cross-validation and corrected significance testing to evaluate whether data fusion improves upon single-modality baselines. We show that data fusion does not uniformly improve accuracy, and that observed gains are modest, oxide-dependent, and sensitive to modality and model structure. To move beyond aggregate accuracy metrics, we use model coefficients, permutation importance, and residual gain analysis to examine how the fusion models weight individual modalities and to identify patterns of apparent complementarity or redundancy. Though focused on spectroscopy for planetary exploration, our framework for data fusion evaluation and interpretation extends to other scientific domains with heterogeneous and scarce data and provides a principled approach evaluating data fusion strategies, interpreting modality contributions, and understanding tradeoffs among data fusion strategies.

97 MATHEMATICS AND COMPUTING↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Evaluation of Material Balance Approaches for Hanford Direct-Feed Low Activity Waste Processing - 20022

The Hanford Site has accumulated millions of gallons of tank waste from reprocessing spent fuel to recover plutonium, uranium, cesium, and strontium. The supernatant from the accumulated tank waste will be treated using a Direct Feed Low-Activity Waste approach. The supernatant will be treated to remove solids and cesium in the Tank-Side Cesium Removal process in the Hanford tank farm, then vitrified in a semi-batch process in the Hanford Waste Treatment and Immobilization Plant (WTP). Currently, each batch of feed is sampled at three locations prior to being fed to the melter: the feed qualification tank in the Hanford tank farm as well as the concentrate receipt vessel (CRV) and melter feed preparation vessel (MFPV) in the WTP. The feed qualification sample is taken from a large batch of accumulated feed, only two to three samples are expected each year. Approximately 275 samples from the CRVs and 1100 samples from the MFPV are expected each year. An evaluation was performed to determine if a material balance based on the feed qualification sample could replace most of the sampling in the CRVs and MFPVs. The evaluation consisted of three elements: (1) determination of the practicality of using a material balance to estimate the stream composition of the CRV and MFPV contents, (2) evaluation of whether the material balance could be automated using the existing process control system, and (3) determination of the uncertainty in glass composition using the material balance approach. It is assumed that periodic sampling at the CRV and MFPV would be performed periodically to re-baseline the material balance, evaluations are in progress to determine the frequency of this periodic sampling. Process sample locations downstream of the melter were reviewed as well, but the partitioning of semi-volatile species in the melter was determined to preclude extending the material balance approach past the melter. It was determined that replacement of the CRV sample location was feasible and did not increase process uncertainty or significantly impact waste loading. Replacement of the MFPV sample was also determined to be feasible, but that measurement of the glass former chemical addition may be needed prior to addition of these chemicals to the MFPV. This measurement could be performed by an in situ laser-induced breakdown spectroscopy (LIBS) system. Limited tests were performed to evaluate LIBS for direct measurements of the low-activity waste melter feed. The use of a material balance would eliminate over 1200 samples each year if only 10% of the CRV and MFPV batches are sampled and could likely allow the WTP laboratory to operate on days only versus 24/7 operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗