High-Performance Thermoelectric Generators for Field Deployments

Thermoelectric power generation is a reliable energy harvesting technique for directly converting heat into electricity. Recent studies have reported the thermal-to-electrical energy conversion efficiency of thermoelectric generators (TEGs) up to 11% under laboratory settings. However, the practical effectiveness of TEGs deployed under real environments is still not more than a few percent. In this study, we provide fundamental insight on the operation of TEGs in realistic environments by illustrating the combinatory effect of thermoelectric material properties, device boundary conditions, and environmental thermal resistivity on TEG performance in conjunction with the module parameters. Using numerical and experimental studies, we demonstrate the existence of a critical heat transfer coefficient that dramatically affects the design and performance of TEGs. Results provide a set of concrete design criteria for developing efficient TEGs that meet the metrics for field deployments. High-performance TEGs demonstrated in this study generated up to 28% higher power and 162% higher power per unit mass of thermoelectric materials as compared to the commercial module deployed for low-grade waste heat recovery. This advancement in understanding the TEG operation will have a transformative impact on the development of scalable thermal energy harvesters and in realizing their practical targets for efficiency, power density, and total output power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Ibuprofen Sodium Dihydrate for Thermochemical Energy Storage

Thermochemical energy storage (TCES) offers a transformative approach to address grid instability by harnessing reversible chemical reactions for efficient heat storage and release. Here, we introduce pharmaceutical organic salt hydrates as a class of materials with exceptional performance for low-grade waste heat recovery. We demonstrate ibuprofen sodium dihydrate (ISD) as an example organic hydrate exhibiting a dehydration temperature range of 60-110 °C and a remarkable dehydration enthalpy of up to 59.5 kJ/mol of water, ideally suited for capturing industrial and residential waste heat. Using rigorous multimodal characterization, including thermogravimetric analysis, differential scanning calorimetry, in-situ FTIR, in-situ PXRD, and NMR, we demonstrate ISD's superior thermal, chemical, and structural stability over 150 hydration-dehydration cycles, achieving an unprecedented cycling efficiency of ~99.9%. Compared to conventional inorganic salt hydrates like strontium chloride hexahydrate and calcium oxalate monohydrate, ISD showcases enhanced durability without deliquescence or pulverization, even under high-humidity conditions. In-situ analyses confirm the transition from ISD to ibuprofen sodium anhydrous (ISA) proceeds with structural reorganization, thereby combining the dehydration mechanism with phase transitions, resulting in higher energy storage capacity. Microstructural analyses reveal that repeated water intercalation and structural transitions aid in creating significant porosity that enhances water transport kinetics, further improving the hydration/dehydration performance. By combining the phase change and chemical dehydration mechanisms, ISD paves the way for designing a new class of organic salt hydrates, offering tunable properties to meet diverse thermal energy storage demands and supporting sustainable grid resilience.

Thangaraj, Kavin C.↗

Building heating and cooling applications thermal energy storage program overview

Thermal energy storage technology and development of building heating and cooling applications in the residential and commercial sectors is outlined. Three elements are identified to undergo an applications assessment, technology development, and demonstration. Emphasis is given to utility load management thermal energy system application where the stress is on the 'customer side of the meter'. Thermal storage subsystems for space conditioning and conservation means of increased thermal mass within the building envelope and by means of low-grade waste heat recovery are covered.

Eissenberg, D. M.↗

Thermomagnetic generators for ultra-low-grade marine thermal energy harvesting

Low-grade thermal gradients in marine environments represent an underexploited energy source for autonomous sensing and monitoring. Converting such small temperature differences into usable electrical power remains a key challenge for ocean-deployed systems. We present a deployable thermomagnetic generator thoroughly characterized for marine-relevant energy harvesting. The device powers an internet-connected sensor and harvests ultra-low temperature differences akin to those at the ocean surface. It draws heat from water and rejects it to ambient air, operating optimally at a temperature difference (ΔT) of ~7.5 °C. Laboratory prototypes generated up to 6.7 mW at ΔT ~ 10 °C with gentle airflow (~1 m s -1 ). A separate controlled wave-tank demonstration validated stable operation and sensor powering under marine-like boundary conditions. Given its voltage and power margins, the generator could sustain multiple sensor nodes. Scalability and material assessments identify modular deployment and non-rare-earth alternatives as pathways toward practical marine energy harvesting and low-grade waste-heat recovery.

16 TIDAL AND WAVE POWER↗

Electric Aircraft Cooling with Bio-Inspired Exergy Management

Future air vehicles will increasingly incorporate electrical powertrains that require very tight system-level integration of power, propulsion, thermal, fault protection, and airframe technologies. This chapter provides an overview of a new category of thermal energy conversion technology and describes the development of the resulting Thermal Recovery Exergy Efficient System, TREES. TREES can be used to enable a fully solid-state integrated thermal and fault management electric aircraft protection system, while synergistically managing and recycling both the low-grade waste heat from electrical components and the high-grade waste heat from engine components. This is achieved with exergy amplification of the powertrain waste heat, a new class of fast flight-weight breakers, a new class of long variable-conductance heat pipes with multiple switchable condensers, a new class of turbofan-integrated heat exchangers, and a gradient-based powertrain system optimizer. This approach is like the human body’s thermal management system in which the heart, arteries, and veins are analogous to the turbofan, acoustic tubes, and heat pipes proposed herein.

Rodger W Dyson↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Closed-loop pressure retarded osmosis draw solutions and their regeneration processes: A review

Pressure-Retarded Osmosis (PRO) is an osmotic process that has been used to harvest energy from salinity gradients using a semi permeable membrane. A comparison between open-loop PRO (OLPRO) and closed-loop PRO (CLPRO) was made regarding their performance and costs. In CLPRO, where the diluted draw solution is re-concentrated in the regeneration system to be reutilized in the process, has recently received an intensive focus as the most viable configuration for a standalone power plant. The choice of the PRO draw solution in CLPRO is crucial to garner a high osmotic pressure as the key for the feasibility of the process. Here, in this review, the draw solutions are critically evaluated in the literature in terms of energy output as well as the method of regeneration used to recirculate them. A set of practical criteria has been suggested to appraise the adequacy of the solution for CLPRO application. It was concluded that NH 3 – CO 2 theoretically can produce 170 W/m 2 of power density. Inorganic draw solutes such as NaCl can generate high power density up to 87 W/m 2 . Organic draw solutes with their remarkably low reverse salt flux (RSF) have promising potential for future application in PRO. Similarly, the regeneration systems of the diluted draw solutions have also been reviewed and discussed. How the energy consumption of the regeneration process affects the feasibility of CLPRO is explained. For the specific case of osmotic heat engines (OHEs), when the energy of the regeneration process is supplied by heat waste, the range of applicability of the heat waste in CLPRO in terms of efficiency is defined and compared to Organic Rankine Cycle (ORC). The results showed that CLPRO has better efficiency than ORC for temperatures T < 80 °C, which makes it a promising process or low-grade heat energy recovery. In addition, a PRO-RO hybrid system coupled with solar power can reduce the net specific energy consumption (SEC) to 0.39 kWh/m 3 . The conditions that regeneration processes should operate under to make PRO viable are discussed in the last section. Overall, the study indicates the key factors for optimizing the performance of CLPRO process.

42 ENGINEERING↗

NASA Thermal Recovery Energy Efficient System (TREES) for Aircraft Exergy Optimization

Future air vehicles will increasingly incorporate electrical powertrains that require very tight integration of power, propulsion, thermal, and airframe technologies. These complex and highly integrated sub-systems present a new exergy utilization and thermo-economics challenge due to the significant and highly distributed low-grade waste heat being produced. One system-wide solution is proposed that utilizes acoustic thermal energy conversion technologies to simultaneously provide thermal management and waste energy recycling for the entire vehicle. This system level solution serves to optimize aircraft exergy utilization.

Dyson, Rodger↗

Thermoacoustic Thermal Management for Electric Aircraft

Electric aircraft research and development is on the rise, necessitating an avant-garde thermal management system to effectively dissipate and reuse the typically wasted low-grade thermal energy generated on electric aircraft. Hence, the Thermal Recovery Exergy Efficient System (TREES) was successfully modeled, designed, built, and tested at NASA Glenn Research Center (NASA GRC) to demonstrate a solution. TREES demonstrates the ability to transport and amplify acoustic energy over various distances, with minimal energy dissipation, while creating a thermoacoustic heat pump that can deliver and absorb thermal energy. The in-house rig is now being utilized as a diagnostics testbed to understand the underlying physics of traveling wave thermoacoustics and to enhance future thermal management technology development.

Thermoacoustics↗

A Modelica Implementation of an Organic Rankine Cycle

Organic Rankine cycle (ORC) systems generate power from low-grade heat sources, such as geothermal sources and industrial waste heat. A key feature is that a working fluid is selected to match the temperature of the source. With the vast pool of candidate working fluids comes the challenge of developing a large number of robust thermodynamic media models. We implemented a subcritical ORC model in Modelica that uses working fluid data records and interpolation schemes in lieu of thermodynamic medium evaluation for energy recovery estimation. This is a component model that can be integrated into a larger energy system model. It does not require detailed thermodynamic, heat transfer, or machine analysis. Our ORC model fills a gap where working fluids are ready to choose or easy to add, and at the same time can be integrated into an energy system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of Two-Phase Dense Fluid Expander for Advanced Cryogenic Air Separation and Low-Grade Heat Recovery

Cryogenic air separation represents the state-of-the-art technology to produce oxygen to feed coal gasification units. Given the maturity of this technology, it is difficult to identify opportunities to improve process efficiency and reduce the cost of the oxygen produced. However, Air Products conducted research and a feasibility investigation into the use of a two-phase (liquid-vapor) dense fluid expander (DFE) to improve the overall efficiency of cryogenic air separation. Demonstration of this novel concept was intended to allow two important process improvements: 1) elimination of the need for the DFE discharge to be single phase 2) expansion of the operating region of expanders in ASU service. Expanding the scope of turboexpander application beyond current application limits and traditional device designs would allow an increase in power recovery, and application of refrigeration and power recovery at new locations in process cycles would also enable the implementation of new process concepts. These new process concepts include power recovery from compression waste heat and refrigeration extraction and power recovery by replacing let-down valves with two-phase DFEs. Considering the maturity of cryogenic air separation, these new process options could represent a step change in power reduction and provide significant savings in operating costs. These new concepts would be particularly well-suited to large-scale oxygen production by cryogenic air separation and would enhance the economics of producing oxygen for use in coal gasification processes. Rotoflow, an Air Products business unit, manufactures dense fluid expanders in Pennsylvania for sites around the world. This project was executed in two phases, which are illustrated in Figure 1 below. Phase 1 consisted of a feasibility investigation of multiple applications of two-phase DFEs. In Phase 2, devices were identified, designed, fabricated and tested to explore the feasibility of commercial applications of DFEs operating in two-phase service. Engineering and testing were performed by personnel in Air Products’ Rotoflow business unit, with coordination with other Air Products business units.

01 COAL, LIGNITE, AND PEAT↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗