Engineering PapersSearch

SEARCH · Engineering Papers

Results for “low-background experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Review of Neutron Yield from (α, n) Reactions: Data, Methods, and Prospects

Understanding the radiogenic neutron production rate through the (α, n) reaction is crucial in many areas of physics, including dark matter searches, neutrino studies, and nuclear astrophysics. In addition to its relevance for fundamental research, the (α, n) reaction also plays a significant role in nuclear energy technologies, for example by contributing to neutron production in subcritical systems using UO2, as well as in applications such as medical physics. This review examines the current state of (α, n) yield calculations and neutron spectra, describes the computational tools used for their estimation, and discusses the available cross-section data. We discuss the uncertainties affecting (α, n) yield estimations and propose a strategy to enhance their accuracy. Furthermore, this paper discusses and emphasizes the need for new measurements of (α, n) cross-sections for a variety of relevant materials. Such measurements are essential for improving neutron flux predictions, which are crucial for reducing uncertainties in sensitivity estimates for next-generation physics experiments operating in the keV—MeV range.

(α, n)reactions

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

UCNProBe NaI Veto System Characterization and Simulation

This paper presents a summary of my research and technical contributions during a summer internship at Los Alamos National Laboratory, supporting the development of the active veto system for the UCNProBe experiment. UCNProBe aims to perform a state-of-the-art measurement of the free neutron lifetime, requiring low-background conditions facilitated by an array of sodium iodide (NaI) scintillators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the 0νββ decay using a high-pressure $^{136}$Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal $^{222}$Rn activity is found to be (0.95±0.04(stat)±0.09(sys)) Bq/m$^{3}$, while no traces of $^{220}$Rn have been observed. Most of the $^{222}$Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced $^{214}$Bi of (0.97±0.05(stat)±0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0νββ region of interest is evaluated as (7.3±1.5(stat)±0.8(sys))×10$^{−4}$ counts/(keV·kg·yr) after selection of the fully contained events. This background index is reduced to ∼4×10$^{−5}$ counts/(keV·kg·yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.[graphic not available: see fulltext]

Cortes-Parra, C. [Valencia U., IFIC] (ORCID:000000

Radioactivity-in-materials lead for nEXO (Final Scientific Report)

Abstract, introduction, and summary of work completed and products produced by DOE award SC002466. Primary products were six peer-reviewed publications and two PhD theses. This award also supported the operation of an underground HPGe detector and several radioassay measurements: one in a stand alone publication in Phys. Rev. C and the others in an upcoming nEXO radioassay summary paper. The nEXO collaboration aims to demonstrate the Majorana nature of the neutrino by observing the neutrinoless double-beta decay of 136 Xe with a next-generation experiment. The University of Kentucky nEXO group (UKY) operates a world-leading ultra-low-background γ-ray spectrometer as part of the nEXO radioactive background control R&D effort. The nEXO project is a proposed ton-scale neutrinoless double-beta decay experiment. The UKY PI is leading the radioactivity content assessment for all materials required by the nEXO project. As a subset of this task, UKY is also responsible for project-wide management of all low-background γ-ray spectrometry measurements; material assays with these types of instruments, together with ICP-MS, neutron-activation-analysis, and α-spectrometry, are critical to ensuring that the nEXO project can achieve its design sensitivity

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]