Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dissolved oxygen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Eddy-Mediated Turbulent Mixing of Oxygen in the Equatorial Pacific

In the tropical Pacific, weak ventilation and intense microbial respiration at depth give rise to a low dissolved oxygen (O 2 ) environment that is thought to be ventilated primarily by the equatorial current system (ECS). The role of mesoscale eddies and vertical mixing as potential pathways of O 2 supply in this region, however, remains poorly known due to sparse observations and coarse model resolution. Using an eddy resolving simulation of ocean circulation and biogeochemistry, we assess the contribution of these processes to the O 2 budget balance and find that vertical mixing of O 2 , which is modulated by the surface wind speed and the vertical shear of the eddying currents, contributes substantially to the replenishment of O 2 in the upper equatorial Pacific thermocline, complementing the advective supply of O 2 by the ECS and meridional circulation at depth. These transport processes vary seasonally in conjunction with the wind: mixing of O 2 into the upper thermocline is strongest during boreal summer and fall when the vertical shear and eddy kinetic energy are intensified. The relationship between eddy activity and the downward mixing of O 2 arises from the modulation of equatorial turbulence by Tropical Instability Waves via their impacts on the vertical shear. This interaction of processes across scales sustains a local pathway of O 2 delivery into the equatorial Pacific interior and highlights the need for adequate observations and models of turbulent mixing and mesoscale processes for understanding and predicting the fate of the tropical Pacific O 2 content in a warmer and more stratified ocean.

Eddy-Mediated↗

Module for Oxygenating Water without Generating Bubbles

A module that dissolves oxygen in water at concentrations approaching saturation, without generating bubbles of oxygen gas, has been developed as a prototype of improved oxygenators for water-disinfection and water-purification systems that utilize photocatalyzed redox reactions. Depending on the specific nature of a water-treatment system, it is desirable to prevent the formation of bubbles for one or more reasons: (1) Bubbles can remove some organic contaminants from the liquid phase to the gas phase, thereby introducing a gas-treatment problem that complicates the overall water-treatment problem; and/or (2) in some systems (e.g., those that must function in microgravity or in any orientation in normal Earth gravity), bubbles can interfere with the flow of the liquid phase. The present oxygenation module (see Figure 1) is a modified version of a commercial module that contains >100 hollow polypropylene fibers with a nominal pore size of 0.05 m and a total surface area of 0.5 m2. The module was originally designed for oxygenation in a bioreactor, with no water flowing around or inside the tubes. The modification, made to enable the use of the module to oxygenate flowing water, consisted mainly in the encapsulation of the fibers in a tube of Tygon polyvinyl chloride (PVC) with an inside diameter of 1 in. (approx.=25 mm). In operation, water is pumped along the insides of the hollow fibers and oxygen gas is supplied to the space outside the hollow tubes inside the PVC tube. In tests, the pressure drops of water and oxygen in the module were found to be close to zero at water-flow rates ranging up to 320 mL/min and oxygen-flow rates up to 27 mL/min. Under all test conditions, no bubbles were observed at the water outlet. In some tests, flow rates were chosen to obtain dissolved-oxygen concentrations between 25 and 31 parts per million (ppm) . approaching the saturation level of approx.=35 ppm at a temperature of 20 C and pressure of 1 atm (approx.=0.1 MPa). As one would expect, it was observed that the time needed to bring a flow of water from an initial low dissolved-oxygen concentration (e.g., 5 ppm) to a steady high dissolved-oxygen concentration at or near the saturation level depends on the rates of flow of both oxygen and water, among other things. Figure 2 shows the results of an experiment in which a greater flow of oxygen was used during the first few tens of minutes to bring the concentration up to approx.=25 ppm, then a lesser flow was used to maintain the concentration.

Gonzalez-Martin, Anuncia↗

Chemical Signatures Associated with the Freshening of Northern Atlantic Waters Between 1972 and 1981

Further insight into the possible causes of the freshening of deep water in the northern Atlantic between the GEOSECS survey (1972) and the TTO survey (1981) is provided by measurements of dissolved silica and dissolved oxygen. As all the northern end member waters are low in dissolved silica content and high in dissolved oxygen content, the message carried by these chemical properties of silica has to do with the extent to which the waters in the northern Atlantic have mixed with the high silica content waters of Antarctic origin. A change in the degree and pattern of this intrusion is noted between the GEOSECS and TTO surveys.

Broecker, W. S.↗

Do it yourself remote sensing: Generating an inexpensive, high tech, real science lake mapping project for the classroom

The utilization of modest equipment and software revealed bottom contours and water column conditions of a dynamic water body. Classroom discussions of field techniques and equipment capabilities followed by exercises with the data sets in cause-and-effect analysis all contributed to participatory education in the process of science. This project is presented as a case study of the value of engaging secondary and collegiate level students in planning, executing and appraising a real world investigation which they can directly relate to. A 1 km wide bay, experiencing marsh inflow, along an 8 km long lake situated 120 km north of Ottawa, Canada, on the glaciated Canadian Precambrian Shield was mapped in midsummer for submerged topography, bottom composition, temperature profile, turbudity, dissolved oxygen and biota distribution. Low level aerial photographs scanned into image processing software are permitting spatial classification of bottom variations in biology and geology. Instrumentation consisted of a portable sport fishing SONAR depth finder, an electronic lead line multiprobe with photocell, thermistor and dissolved oxygen sensors, a selective depth water sampler, portable pH meter, an underwater camera mounted on a home-made platform with a bottom-contact trigger and a disposable underwater camera for shallow survey work. Sampling transects were referenced using a Brunton hand transit triangulating several shore markers.

Metzger, Stephen M.↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2023 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. Last year’s paper reported a fault condition termed “electrode bridging,” in which silver deposits on interelectrode wetted materials, eventually bridging the electrode gap and providing an alternate conduction pathway that diminishes the silver output of the reactor. Since then, two strategies have been developed that prevent this fault from occurring: 1) increasing the frequency of polarity reversal and 2) separating the active surface of the electrode from the interelectrode wetted material. These strategies were tested independently, and in both cases, the reactor performed as expected with no occurrence of bridging for at least one crew-year equivalent of cumulative operation. Additional tests were conducted at varying levels of influent dissolved oxygen to better understand the nature of the cathode reaction and its impact on reactor performance. Results indicate that the primary cathode reaction is the reduction of dissolved oxygen, which could imply a dependence of reactor performance on dissolved oxygen concentration. However, it was found that at the typical oxygen concentrations anticipated for spacecraft processed water, the impact on silver electrolysis performance was negligible. Finally, multiphysics modelling of the reactor fluid mechanics and electrochemistry was undertaken to provide the capability to optimize the design of a future reactor prototype.

silver electrolysis↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2023 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. Last year’s paper reported a fault condition termed “electrode bridging,” in which silver deposits on interelectrode wetted materials, eventually bridging the electrode gap and providing an alternate conduction pathway that diminishes the silver output of the reactor. Since then, two strategies have been developed that prevent this fault from occurring: 1) increasing the frequency of polarity reversal and 2) separating the active surface of the electrode from the interelectrode wetted material. These strategies were tested independently, and in both cases, the reactor performed as expected with no occurrence of bridging for at least one crew-year equivalent of cumulative operation. Additional tests were conducted at varying levels of influent dissolved oxygen to better understand the nature of the cathode reaction and its impact on reactor performance. Results indicate that the primary cathode reaction is the reduction of dissolved oxygen, which could imply a dependence of reactor performance on dissolved oxygen concentration. However, it was found that at the typical oxygen concentrations anticipated for spacecraft processed water, the impact on silver electrolysis performance was negligible. Finally, multiphysics modelling of the reactor fluid mechanics and electrochemistry was undertaken to provide the capability to optimize the design of a future reactor prototype.

silver electrolysis↗

Aquatic sources and sinks for nitrous oxide

Data are presented which suggest the complexity of the aquatic nitrogen cycle as it affects N2O. The data are from studies made in the central and south-east tropical regions of the Pacific Ocean and in Chesapeake Bay. The data indicate that oxidation of ammonium and amino nitrogen and nitrification form the principle source for marine N2O. It is estimated that the yearly global yield for oceanic N2O is less than about 10 to the 7th power tons. The consumption of atmospheric N2O by the open ocean has not been evidenced, although data from the south-east tropical Pacific and Chesapeake Bay show the consumption of dissolved N2O in low-oxygen conditions. Preliminary observations have also indicated the consumption of atmospheric N2O by aquatic systems such as freshwater pond and a tidal saltmarsh.

Elkins, J. W.↗

Canaveral National Seashore Water Quality and Aquatic Resource Inventory

Mosquito Lagoon is a shallow, bar-built estuary located on the east central Florida Coast, primarily within the KSC boundary. The lagoon and watershed cover approximately 327 sq km (79422 acres) .The Lagoon occupies 159 sq km (37853 acres). Water depths average approximately 1m. The lagoon volume is approximately 1.6 x 10(exp 8)cu m. Water quality in Mosquito Lagoon is good. Salinity data typically range between 20 ppt and 35 ppt. The lowest value recorded was 4.5 ppt and the highest value was 37 ppt. Water temperatures fluctuate 2 - 3 C over a 24 h period. Cold front passage can rapidly alter water temperatures by 5 - 10 C or more in a short period of time. The highest temperature was 33.4 C and the lowest temperature was 8.8 C after a winter storm. Dissolved oxygen concentrations ranged from a low of 0.4 mg/l to a high of 15.3 mg/l. Extended periods of measurements below the Florida Department of Environmental Protection criteria of 4.0 mg/l were observed in fall and spring months suggesting high system respiration and oxygen demand. Metals such as antimony, arsenic, molybdenum and mercury were report as below detection limits for all samples. Cadmium, copper, chromium, silver, and zinc were found to be periodically above the Florida Department of Environmental Protection criteria for Class II and Class III surface waters.

Hall, C. R.↗

The effect of oxygen fugacity on the solubility of carbon-oxygen fluids in basaltic melt

The solubility of CO2-CO fluids in a midocean ridge basalt have been measured at 1200 C, 500-1500 bar, and oxygen fugacities between NNO and NNO-4. In agreement with results of previous studies, the results reported here imply that, at least at low pressures, CO2 dissolves in basaltic melt only in the form of carbonate groups. The dissolution reaction is heterogeneous, with CO2 molecules in the fluid reacting directly with reactive oxygens in the melt to produce CO3(2-). CO, on the other hand, is insoluble, dissolving neither as carbon, molecular CO, nor CO3(2-). It is shown that, for a given pressure and temperature, the concentration of dissolved carbon-bearing species in basaltic melt in equilibrium with a carbon-oxygen fluid is proportional to the mole fraction of CO2 in the fluid, which is a function of fO2. At low pressures CO2 solubility is a linear function of CO2 fugacity at constant temperatures.

Pawley, Alison R.↗

Measurement and Control of Oxygen Partial Pressure in an Electrostatic Levitator

Recently the NASA Marshall Space Flight Center electrostatic levitation (ESL) laboratory has been upgraded to include an oxygen control system. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, at elevated temperatures, theoretically in the range from 10(exp -36) to 10(exp 0) bar. The role of active surface agents in liquid metals is fairly well known; however, published surface tension data typically has large scatter, which has been hypothesized to be caused by the presence of oxygen. The surface tension of metals is affected by even a small amount of adsorption of oxygen. It has even been shown that oxygen partial pressures may need to be as low as 10(exp -24) bar to avoid oxidation. While electrostatic levitation is done under high vacuum, oxide films or dissolved oxygen may have significant effects on materials properties, such as surface tension and viscosity. Therefore, the ability to measure and control the oxygen partial pressure within the chamber is highly desirable. The oxygen control system installed at MSFC contains a potentiometric sensor, which measures the oxygen partial pressure, and an oxygen ion pump. In the pump, a pulse-width modulated electric current is applied to yttrium-stabilized zirconia, resulting in oxygen transfer into or out of the system. Also part of the system is a control unit, which consists of temperature controllers for the sensor and pump, PID-based current loop for the ion pump, and a control algorithm. This system can be used to study the effects of oxygen on the thermophysical properties of metals, ceramics, glasses, and alloys. It can also be used to provide more accurate measurements by processing the samples at very low oxygen partial pressures. The oxygen control system will be explained in more detail and an overview of its use and limitations in an electrostatic levitator will be described. Some preliminary measurements have been made, and the results to date will be provided.

SanSoucie, Michael P.↗

Cavitating Jet Method and System for Oxygenation of Liquids

Reclamation and re-use of water is critical for space-based life support systems. A number of functions must be performed by any such system including removal of various contaminants and oxygenation. For long-duration space missions, this must be done with a compact, reliable system that requires little or no use of expendables and minimal power. DynaJets cavitating jets can oxidize selected organic compounds with much greater energy efficiency than ultrasonic devices typically used in sonochemistry. The focus of this work was to develop cavitating jets to simultaneously accomplish the functions of oxygenation and removal of contaminants of importance to space-structured water reclamation systems. The innovation is a method to increase the concentration of dissolved oxygen or other gasses in a liquid. It utilizes a particular form of novel cavitating jet operating at low to moderate pressures to achieve a high-efficiency means of transporting and mixing the gas into the liquid. When such a jet is utilized to simultaneously oxygenate the liquid and to oxidize organic compounds within the liquid, such as those in waste water, the rates of contaminant removal are increased. The invention is directed toward an increase in the dissolved gas content of a liquid, in general, and the dissolved oxygen content of a liquid in particular.

Chahine, Georges L.↗

Replication of the Apparent Excess Heat Effect in a Light Water-Potassium Carbonate-Nickel Electrolytic Cell

Replication of experiments claiming to demonstrate excess heat production in light water-Ni-K2CO3 electrolytic cells was found to produce an apparent excess heat of 11 W maximum, for 60 W electrical power into the cell. Power gains range from 1.06 to 1.68. The cell was operated at four different dc current levels plus one pulsed current run at 1 Hz, 10% duty cycle. The 28 liter cell used in these verification tests was on loan from a private corporation whose own tests with similar cells are documented to produce 50 W steady excess heat for a continuous period exceeding hundreds of days. The apparent excess heat can not be readily explained either in terms of nonlinearity of the cell's thermal conductance at a low temperature differential or by thermoelectric heat pumping. However, the present data do admit efficient recombination of dissolved hydrogen-oxygen as an ordinary explanation. Calorimetry methods and heat balance calculations for the verification tests are described. Considering the large magnitude of benefit if this effect is found to be a genuine new energy source, a more thorough investigation of evolved heat in the nickel-hydrogen system in both electrolytic and gaseous loading cells remains warranted.

Niedra, Janis M.↗

Iron and sulfur in the pre-biologic ocean

Tentative geochemical cycles for the pre-biologic Earth are developed by comparing the relative fluxes of oxygen, dissolved iron, and sulfide to the atmosphere and ocean. The flux of iron is found to exceed both the oxygen and the sulfide fluxes. Because of the insolubility of iron oxides and sulfides the implication is that dissolved iron was fairly abundant and that oxygen and sulfide were rare in the atmosphere and ocean. Sulfate, produced by the oxidation of volcanogenic sulfur gases, was the most abundant sulfur species in the ocean, but its concentration was low by modern standards because of the absence of the river-borne flux of dissolved sulfate produced by oxidative weathering of the continents. These findings are consistent with the geologic record of the isotopic composition of sedimentary sulfates and sulfides. Except in restricted environments, the sulfur metabolism of the earliest organisms probably involved oxidized sulfur species not sulfide.

Review↗

Indicators of Climate Change Impacts on the Water Cycle and Water Management

Managing water is a top social and economic responsibility and is expected to become even more critical as climate change, in addition to other human activities, alters water availability and quality. Robust indicators reflecting the effects of climate change on the U.S. and global water cycles are needed in order to appropriately manage water resources. Here, we describe a suite of seventeen water cycle and management indicators, which are based on synthesis of available datasets. These indicators include: average and heavy precipitation, standardized precipitation index, annual, 7-day low and 3-day high streamflow volume, streamflow timing, snow cover, snow water equivalent, groundwater level, lake water temperature, stream water temperature, dissolved oxygen, salinity, Palmer Drought Severity Index, water withdrawals and water use. We also identify three indicators that could be included in the suite of water cycle and management indicators with some additional, directed work: snowfall, evapotranspiration and soil moisture. Our conceptual framework focuses on known water cycle changes in addition to potential effects on management, and addresses water quantity and quality, as well as water use and related interactions with freshwater ecosystems, societal impacts, and management. Water cycle indicators are organized into three categories: (1) hydrologic processes, (2) water quality processes, and (3) water quality and quantity impacts. Indicators described here are recommended to serve as critical references for periodic climate assessments. As such, these indicators support analyses of the effects of global change on the natural environment, agriculture, energy, and water resources, among other sectors. Additionally, we identify research gaps and needs that can be addressed to advance the development of future indicators.

Christa D Peters-Lidard↗

Holographic particle detection

The feasibility was studied of developing a novel particle track detector based on the detection of 1p-1s emission radiation from electron bubbles in liquid helium. The principles, design, construction, and initial testing of the detection system have been described in previous reports. The main obstacle encountered was the construction of the liquid-helium tight infrared windows. Despite numerous efforts in testing and redesigning the windows, the problem of window leakage at low temperature persisted. Due to limited time and resources, attention was switched to investigating the possibility of using room-temperature liquid as the detection medium. A possible mechanism was the detection of de-excitation radiation emitted from localized electrons in common liquids where electrons exhibit low mobilities, as suggested in the previous report. The purity of the liquid is critical in this method as the dissolved impurities (such as oxygen), even in trace amounts, will act as scavengers of electrons. Another mechanism is discussed whereby the formation of the superoxide ions by electron scavenging behavior of dissolved oxygen is exploited to detect the track of ionizing particles. An experiment to measure the ionization current produced in a liquid by a pulsed X-ray beam in order to study propertiies of the ions is also reported.

Bowen, Theodore↗

Flexible Microsensor Array for the Root Zone Monitoring of Porous Tube Plant Growth System

Control of oxygen and water in the root zone is vital to support plant growth in the microgravity environment. The ability to control these sometimes opposing parameters in the root zone is dependent upon the availability of sensors to detect these elements and provide feedback for control systems. In the present study we demonstrate the feasibility of using microsensor arrays on a flexible substrate for dissolved oxygen detection, and a 4-point impedance microprobe for surface wetness detection on the surface of a porous tube (PT) nutrient delivery system. The oxygen microsensor reported surface oxygen concentrations that correlated with the oxygen concentrations of the solution inside the PT when operated at positive pressures. At negative pressures the microsensor shows convergence to zero saturation (2.2 micro mol/L) values due to inadequate water film formation on porous tube surface. The 4-point microprobe is useful as a wetness detector as it provides a clear differentiation between dry and wet surfaces. The unique features of the dissolved oxygen microsensor array and 4-point microprobe include small and simple design, flexibility and multipoint sensing. The demonstrated technology is anticipated to provide low cost, and highly reliable sensor feedback monitoring plant growth nutrient delivery system in both terrestrial and microgravity environments.

Sathyan, Sandeep↗

The effects of atomic oxygen on polymeric materials

At the altitudes of low-earth orbit (LEO), atomic oxygen (AO) is the most abundant chemical species. This strong oxidizing agent reacts with virtually any organic material that is not already fully oxidized. Erosion by AO can be extensive and jeopardizes any protective coatings, thermal blankets, adhesives, and structural composites exposed on the exterior of satellites in LEO. Researchers prepared and tested organic materials for their susceptibility to AO using a commercial plasma asher which approximately simulates the oxygen effects in LEO. Experiments were performed on a polyimide, a polysulfone, and two epoxy adhesives into which low molecular-weight additives have been dissolved. Incorporated in the molecular structure of these additives are elements such as silicon whose nonvolatile oxides, which are formed on exposure to AO, remain as a coating on the surface to create a barrier between the remainder of the organic material and the AO. We find that the additives protect the materials, but the low solubility of some limit their utility. Concurrent studies are underway to measure the effect of the additives on the thermal expansion coefficients of the materials. Tows of aramid fibers, which are important components in the proposed tether satellite systems, have been eroded in the asher. The results which show that the square root of the mass remaining decreases linearly with the time of exposure (see the figure) are consistent with a constant rate of surface erosion. The tensile strength of these eroded tows decreases with time of exposure also; additional measurements are in progress.

Orwoll, Robert A.↗

Electrochemical, H2O2-Boosted Catalytic Oxidation System

An improved water-sterilizing aqueous-phase catalytic oxidation system (APCOS) is based partly on the electrochemical generation of hydrogen peroxide (H2O2). This H2O2-boosted system offers significant improvements over prior dissolved-oxygen water-sterilizing systems in the way in which it increases oxidation capabilities, supplies H2O2 when needed, reduces the total organic carbon (TOC) content of treated water to a low level, consumes less energy than prior systems do, reduces the risk of contamination, and costs less to operate. This system was developed as a variant of part of an improved waste-management subsystem of the life-support system of a spacecraft. Going beyond its original intended purpose, it offers the advantage of being able to produce H2O2 on demand for surface sterilization and/or decontamination: this is a major advantage inasmuch as the benign byproducts of this H2O2 system, unlike those of systems that utilize other chemical sterilants, place no additional burden of containment control on other spacecraft air- or water-reclamation systems.

Akse, James R.↗