Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loss measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

757 Path Loss Measurements

Path Loss Measurements were obtained on three (3) GPS equipped 757 aircraft. Systems measured were Marker Beacon, LOC, VOR, VHF (3), Glide Slope, ATC (2), DME (2), TCAS, and GPS. This data will provide the basis for assessing the EMI (Electromagnetic Interference) safety margins of comm/nav (communication and navigation) systems to portable electronic device emissions. These Portable Electronic Devices (PEDs) include all devices operated in or around the aircraft by crews, passengers, servicing personnel, as well as the general public in the airport terminals. EMI assessment capability is an important step in determining if one system-wide PED EMI policy is appropriate. This data may also be used comparatively with theoretical analysis and computer modeling data sponsored by NASA Langley Research Center and others.

Horton, Kent↗

Measured losses in superconductor magnets for 60-Hertz ac operation.

Results of an experimental study of electrical losses in superconductor magnets. Preliminary 60-Hz ac loss data are presented for coils constructed of Nb3Sn ribbon, Nb-Ti cable, and multifilament Nb-Ti. Losses have been measured for different size coils up to approximately 20 cm in diameter. Of the conductor types tested, Nb3Sn ribbon has the lowest losses for ac operation. In Nb3Sn-ribbon coils of different sizes, the loss per unit length of conductor is shown to decrease with a decrease in the rate of change of current and to increase, in general, with increase in coil size. An important aspect of the study is the high degree of repeatability of the data.

Hamlet, I. L.↗

Antenna and radome loss measurements for MFMR and PMIS with appendix on MFMR/PMIS computer programs

The NMSU/PSL radiometer antenna calibration facility is described, and the antenna and radome loss measurements made on the passive microwave imaging system and the multifrequency microwave radiometer are summarized. Antenna/radome data reduction techniques, estimation of sky brightness temperatures, and bucket performance tests are presented along with radiometer computer programs.

Carver, K. R.↗

Precision bone and muscle loss measurements by advanced, multiple projection DEXA (AMPDXA) techniques for spaceflight applications

An advanced, multiple projection, dual energy x-ray absorptiometry (AMPDXA) scanner system is under development. The AMPDXA is designed to make precision bone and muscle loss measurements necessary to determine the deleterious effects of microgravity on astronauts as well as develop countermeasures to stem their bone and muscle loss. To date, a full size test system has been developed to verify principles and the results of computer simulations. Results indicate that accurate predictions of bone mechanical properties can be determined from as few as three projections, while more projections are needed for a complete, three-dimensional reconstruction. c 2001. Elsevier Science Ltd. All rights reserved.

NASA Discipline Life Sciences Technologies↗

Automated Transmission Loss Measurement in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center

A technique to measure the radiated acoustic intensity and transmission loss of panels is documented in this paper. This facility has been upgraded to include a test fixture that scans the acoustic intensity radiated from a panel on the anechoic receiving room side of the transmission loss window. The acoustic intensity incident on the panel from the reverberant side of the transmission loss window is estimated from measurements made using six stationary microphones in the reverberant source room. From the measured incident and radiated intensity, the sound power transmission loss is calculated. The setup of the facility and data acquisition system are documented. A transmission loss estimate of a typical panel is shown. The measurement-to-measurement and setup-to-setup repeatability of the transmission loss estimate are assessed. Conclusions are drawn about the ability to measure changes in transmission loss due to changes in panel construction.

Klos, J.↗

Radiative Heat Loss Measurements During Microgravity Droplet Combustion in a Slow Convective Flow

Radiative heat loss from burning droplets in a slow convective flow under microgravity conditions is measured using a broad-band (0.6 to 40 microns) radiometer. In addition, backlit images of the droplet as well as color images of the flame were obtained using CCD cameras to estimate the burning rates and the flame dimensions, respectively. Tests were carried out in air at atmospheric pressure using n-heptane and methanol fuels with imposed forced flow velocities varied from 0 to 10 centimeters per second and initial droplet diameters varied from 1 to 3 millimeters. Slow convective flows were generated using three different experimental configurations in three different facilities in preparation for the proposed International Space Station droplet experiments. In the 2.2 Second Drop-Tower Facility a droplet supported on the leading edge of a quartz fiber is placed within a flow tunnel supplied by compressed air. In the Zero-Gravity Facility (five-second drop tower) a tethered droplet is translated in a quiescent ambient atmosphere to establish a uniform flow field around the droplet. In the KC 135 aircraft an electric fan was used to draw a uniform flow past a tethered droplet. Experimental results show that the burn rate increases and the overall flame size decreases with increases in forced-flow velocities over the range of flow velocities and droplet sizes tested. The total radiative heat loss rate, Q(sub r), decreases as the imposed flow velocity increases with the spherically symmetric combustion having the highest values. These observations are in contrast to the trends observed for gas-jet flames in microgravity, but consistent with the observations during flame spread over solid fuels where the burning rate is coupled to the forced flow as here.

Hicks, Michael C.↗

Accurate Insertion Loss Measurements of the Juno Patch Array Antennas

This paper describes two independent methods for estimating the insertion loss of patch array antennas that were developed for the Juno Microwave Radiometer instrument. One method is based principally on pattern measurements while the other method is based solely on network analyzer measurements. The methods are accurate to within 0.1 dB for the measured antennas and show good agreement (to within 0.1dB) of separate radiometric measurements.

insertion loss↗

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗

Small Aircraft RF Interference Path Loss Measurements

Interference to aircraft radio receivers is an increasing concern as more portable electronic devices are allowed onboard. Interference signals are attenuated as they propagate from inside the cabin to aircraft radio antennas mounted on the outside of the aircraft. The attenuation level is referred to as the interference path loss (IPL) value. Significant published IPL data exists for transport and regional category airplanes. This report fills a void by providing data for small business/corporate and general aviation aircraft. In this effort, IPL measurements are performed on ten small aircraft of different designs and manufacturers. Multiple radio systems are addressed. Along with the typical worst-case coupling values, statistical distributions are also reported that could lead to more meaningful interference risk assessment.

Nguyen, Truong X.↗

Chromosomal mutations and chromosome loss measured in a new human-hamster hybrid cell line, ALC: studies with colcemid, ultraviolet irradiation, and 137Cs gamma-rays

Small mutations, megabase deletions, and aneuploidy are involved in carcinogenesis and genetic defects, so it is important to be able to quantify these mutations and understand mechanisms of their creation. We have previously quantified a spectrum of mutations, including megabase deletions, in human chromosome 11, the sole human chromosome in a hamster-human hybrid cell line AL. S1- mutants have lost expression of a human cell surface antigen, S1, which is encoded by the M1C1 gene at 11p13 so that mutants can be detected via a complement-mediated cytotoxicity assay in which S1+ cells are killed and S1- cells survive. But loss of genes located on the tip of the short arm of 11 (11p15.5) is lethal to the AL hybrid, so that mutants that have lost the entire chromosome 11 die and escape detection. To circumvent this, we fused AL with Chinese hamster ovary (CHO) cells to produce a new hybrid, ALC, in which the requirement for maintaining 11p15.5 is relieved, allowing us to detect mutations events involving loss of 11p15.5. We evaluated the usefulness of this hybrid by conducting mutagenesis studies with colcemid, 137Cs gamma-radiation and UV 254 nm light. Colcemid induced 1000 more S1- mutants per unit dose in ALC than in AL; the increase for UV 254 nm light was only two-fold; and the increase for 137Cs gamma-rays was 12-fold. The increase in S1- mutant fraction in ALC cells treated with colcemid and 137Cs gamma-rays were largely due to chromosome loss and 11p deletions often containing a breakpoint within the centromeric region.

NASA Discipline Radiation Health↗

Acoustic Directivity and Insertion Loss Measurements of Advanced Liners Installed the Inlet of the DGEN Aeropropulsion Research Turbofan

The NASA Glenn Research Center’s DGEN Aeropropulsion Research Turbofan (DART) is based on the Price Induction DGEN380—a small, ~500-lbf thrust class, high-bypass, geared-turbofan engine with a separate flow nozzle. The general characteristics of the DART make it an ideal candidate for utilization as a test bed for engine aeroacoustic research in a relevant performance environment. The DART was used to document the efficacy of acoustic liners installed in the inlet of the DGEN380. An advanced multi-degree-of-freedom liner (MDOF) was designed and tested, along with a traditional single-degree-of- freedom liner (SDOF), and those results compared to a hard-wall baseline inlet. Farfield acoustic data were acquired from an external array, evaluated, and reported here-in terms of overall, broadband, and tonal components of the insertion loss.

Noise Reduction↗

A comparison between numerically modelled and experimentally measured loss mechanisms in wave rotors

A numerical model has been developed which is capable of predicting the performance of a wave rotor (pressure exchanger) of specified geometry over a wide range of operating conditions. The model can account for the major loss mechanisms of leakage from the tube ends, fluid viscosity, heat transfer to the tube wails, finite tube opening time, shock waves, and non-uniform port flows. It is a one dimensional flow model which follows a single tube as it rotates past the various stationary ports. Since the model is relatively simple (i.e., one dimensional) it uses little computer time. This makes it suitable for design as well as analytical purposes. This paper will present a brief description of the model then discuss a comparison between the model predictions and several wave rotor experiments.

Paxson, Daniel E.↗