Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of local cooling on sweating rate and cold sensation

Subjects resting in a 39 C environment were stimulated in different skin regions with a water-cooled thermode. Results indicate that cooling different body regions produces generally equivalent decreases in sweating rate and increases in cold sensation, with the forehead showing a much greater sensitivity per unit area and temperature decrease than other areas. The high thermal sensitivity of the face may have evolved when it was the thinnest-furred area of the body; today's clothing habits have reestablished the importance of the face in the regulation of body temperature.

Crawshaw, L. I.↗

Localized cooling of electronic components

Board-mounted electronic components are cooled quickly and conveniently for troubleshooting with aid of device that produces cold jet of dry oxygen. It can cool nonflat and hard-to-reach components.

Source record↗

Ayres' bifurcated solar model

The assumptions of Ayres' model of the upper solar atmosphere are examined. It is found that the bistable character of his model is postulated - through the assumptions concerning the opacity sources and the effect of mechanical waves, which are allowed to destroy the CO molecules but not to heat the gas. The neglect of cooling by metal lines is based on their reduced local cooling rate, but it ignores the increased depth over which this cooling occurs. Thus, the bifurcated model of the upper solar atmosphere consists of two models, one cold at the temperature minimum, with a kinetic temperature of 2900 K, and the other hot, with a temperature of 4900 K.

Kalkofen, W.↗

A numerical investigation of severe thunderstorm gust fronts

A numerical model was developed to simulate the evolution and structure of severe thunderstorm gust fronts. The model is a non-hydrostatic, fine resolution, cross-sectional primitive equation model. Two-dimensional horizontal and vertical equations of motion, the continuity equation, and the thermodynamic energy equation were utilized. It was shown that two dominant factors influencing gust front configuration are surface friction and the solenoidal field coincident with the front. It is suggested that solenoidal accelerations oppose the deceleration of surface friction. After a downdraft is initiated in the model, these opposing tendencies soon reach a balance and the gust front achieves a quasi-steady configuration. Thus, the experiments indicate that surface friction does not induce a cycle of front formation and collapse. In addition, the effect of evaporative cooling in producing a vigorous downdraft was parameterized by a local cooling function. Greater cooling in the downdraft results in a more intense gust front that exhibits stronger wind maximums and greater shears. The ambient air stability was shown to be an important factor influencing the depth of the cold outflow.

Mitchell, K. E.↗

Inverse Compton Cooling in the Coronae of Simulated Black Hole Accretion Flows

We present a formulation for a local cooling function to be employed in the diffuse, hot corona region of 3D GRMHD simulations of accreting black holes. This new cooling function calculates the cooling rate due to inverse Compton scattering by considering the relevant microphysics in each cell in the corona and approximating the radiation energy density and Compton temperature there by integrating over the thermal seed photon flux from the disk surface. The method either assumes ion and electron tem- peratures are equal (1T), or calculates them separately (2T) using an instantaneous equilibrium approach predicated on the actual relevant rate equations (Coulomb and Compton). The method is shown to be consistent with a more detailed ray-tracing calculation where the bulk of the cooling occurs, but is substantially less costly to per- form. As an example, we apply these methods to a harm3d simulation of a 10M⊙, non-spinning black hole, accreting at nominally 1% the Eddington value. Both 1T and 2T approaches lead to increased radiative efficiency and a larger fraction of total cooling in the corona as compared to the original target-temperature cooling function used by harm3d, especially in the 1T case. Time-averaged post-processing reveals that the continuum spectral observations predicted from these simulations are qualitatively similar to actual X-ray binary data, especially so for the 1T approach which yields a harder power-law component (Γ = 2.25) compared to the 2T version (Γ = 2.53).

Brooks E. Kinch↗

The X-ray Spectrum of the North Polar Spur

An analysis is presented of the soft X-ray background spectrum measured by the EPIC MOS cameras on XMM-Newton in three observations targeted on the North Polar Spur (NPS). Three distinct Galactic plasma components are identified, a cool Local Hot Bubble (LHB) component, T(sub lo) approx. 0.1 keV, a cool Galactic Halo component at a similar temperature and a hotter component, T(sub hi) approx. 0.26 keV, associated with the NPS itself. Using the new data in combination with the Rosat All-Sky Survey count rates measured in the 0.1-0.4 keV band, we estimate the emission measure of the LHB material to be 0.0040-0.0052 cm(exp -6) pc, which implies an electron density of 0.008-0.011 cm(exp -3) and pressure of approx. 22000 cm(exp -3) K. The halo and NPS components lie behind at least 50% of the line-of-sight cold gas for which the total Galactic column density is in the range (2 - 8) x 10(exp 20) cm(exp -2). Modelling the X-ray emitting superbubble as a sphere at distance 210 pc, radius 140 pc and center l(sub II) = 352 deg, b(sub II) = 15 deg, the implied electron density in the NPS is approx. 0.03 cm(exp -3) with pressure approx. 150000 cm(exp -3) K. The observed spectral line complexes from OVII, OVIII, FeXVII, NeIX, NeX and MgXI provide constraints on the composition of the plasma. The hot component in the NPS is depleted in oxygen, neon and, to some extent, magnesium and iron. Assuming the effective line of sight across the halo emission is 1 kpc, the electron density in the halo is 0.007-0.011 cm(exp -3) and the pressure is approx. 16500 cm(exp -3) K, conditions very similar to those in the LHB.

Willingale, Richard↗

Steady state cooling flow models with gas loss for normal elliptical galaxies

A grid of cooling flow models for the hot gas in normal elliptical galaxies is calculated, including the loss of gas due to inhomogeneous cooling. The loss process is modeled as a distributed sink for the gas with the rate of loss being proportional to the local cooling rate. The cooling flow models with gas loss have smaller sonic radii, smaller inflow rates in their central regions, lower densities, and higher temperatures than homogeneous models. The reduction in the amount of hot gas flowing into the center of the models brings the models into much better agreement with the observed X-ray surface brightness profiles of elliptical galaxies. However, there is a large dispersion in the observed X-ray luminosities of ellipticals, and this cannot be explained by variations in the efficiency of gas loss. The gas-loss models have X-ray surface brightness profiles which are much less centrally peaked than the no-gas-loss models.

Sarazin, Craig L.↗

The effect of snow cover on the climate

Large-scale snow cover anomalies are thought to cause significant changes in the diabatic heating of the earth's surface in such a way as to produce substantial local cooling in the surface temperatures. This theory was tested using the GISS 3D GCM (General Circulation Model). The results of the GCM experiment showed that snow cover caused only a short term local decrease in the surface temperature. In the surface energy budget, reduction in absorbed shortwave radiation and the increased latent heat sink of melting snow contributed to lower temperatures. However, all the remaining heating terms contribute to increasing the net heating over a snow covered surface. The results emphasize the negative feedback which limits the impact of snow cover anomalies over longer time scales.

Cohen, Judah↗

Mergers, cooling flows, and evaporation

Mergers (the capture of cold gas, especially) can have a profound influence on the hot coronal gas of early-type galaxies and clusters, potentially inducing symptoms hitherto attributed to a cooling flow, if thermal conduction is operative in the coronal plasma. Heat can be conducted from the hot phase into the cold phase, simultaneously ionizing the cold gas to make optical filaments, while locally cooling the coronal gas to mimic a cooling-flow. If there is heat conduction, though, there is no standard cooling-flow since radiative losses are balanced by conduction and not mass deposition. Amongst the strongest observational support for the existence of cooling-flows is the presence of intermediate temperature gas with x-ray emission-line strengths in agreement with cooling-flow models. Here, x-ray line strengths are calculated for this alternative model, in which mergers are responsible for the observed optical and x-ray properties. Since gas around 10(exp 4) K is thermally stable, the cold cloud need not necessarily evaporate and hydrostatic solutions exist. Good agreement with the x-ray data is obtained. The relative strengths of intermediate temperature x-ray emission lines are in significantly better agreement with a simple conduction model than with published cooling-flow models. The good agreement of the conduction model with optical, infrared and x-ray data indicates that significantly more theoretical effort into this type of solution would be profitable.

Sparks, W. B.↗

Mitigating Climate Change with Earth Orbital Sunshades

An array of rotating sunshades based on emerging solar sail technology will be deployed in a novel Earth orbit to provide near-continuous partial shading of the Earth, reducing the heat input to the atmosphere by blocking a small percentage of the incoming sunlight, and mitigating local weather effects of anticipated climate change over the next century. The technology will provide local cooling relief during extreme heat events (and heating relief during extreme cold events) thereby saving human lives, agriculture, livestock, water and energy needs. A synthesis of the solar sail design, the sails' operational modes, and the selected orbit combine to provide local weather modification.

Coverstone, Victoria↗

Failure Investigation of an Intra-Manifold Explosion in a Horizontally-Mounted 870 lbf Reaction Control Thruster

In June 2010, an 870 lbf Space Shuttle Orbiter Reaction Control System Primary Thruster experienced an unintended shutdown during a test being performed at the NASA White Sands Test Facility. Subsequent removal and inspection of the thruster revealed permanent deformation and misalignment of the thruster valve mounting plate. Destructive evaluation determined that after three nominal firing sequences, the thruster had experienced an energetic event within the fuel (monomethylhydrazine) manifold at the start of the fourth firing sequence. The current understanding of the phenomenon of intra-manifold explosions in hypergolic bipropellant thrusters is documented in literature where it is colloquially referred to as a ZOT. The typical ZOT scenario involves operation of a thruster in a gravitational field with environmental pressures above the triple point pressure of the propellants. Post-firing, when the thruster valves are commanded closed, there remains a residual quantity of propellant in both the fuel and oxidizer (nitrogen tetroxide) injector manifolds known as the "dribble volume". In an ambient ground test configuration, these propellant volumes will drain from the injector manifolds but are impeded by the local atmospheric pressure. The evacuation of propellants from the thruster injector manifolds relies on the fluids vapor pressure to expel the liquid. The higher vapor pressure oxidizer will evacuate from the manifold before the lower vapor pressure fuel. The localized cooling resulting from the oxidizer boiling during manifold draining can result in fuel vapor migration and condensation in the oxidizer passage. The liquid fuel will then react with the oxidizer that enters the manifold during the next firing and may produce a localized high pressure reaction or explosion within the confines of the oxidizer injector manifold. The typical ZOT scenario was considered during this failure investigation, but was ultimately ruled out as a cause of the explosion. Converse to the typical ZOT failure mechanism, the failure of this particular thruster was determined to be the result of liquid oxidizer being present within the fuel manifold.

Durning, Joseph G., III↗

Self-irradiated cooling condensations - The source of the optical line emission from cooling flows

The optical filaments seen at the centers of clusters of galaxies, which cannot be explained by standard photoionization or shock models, can be straightforwardly interpreted as self-irradiated cooling condensations. Fully developed (about 10,000 K) condensations embedded in thermally unstable 10 million K gas will be bathed in a powerful EUV/soft X-ray flux emanating from the surrounding condensing regions. The present models of the condensation/irradiation process give line ratios and luminosities similar to those observed. Because it is assumed that the condensations arise from linear perturbations, which grow significantly only when the local cooling time is less than the free-fall time, condensing regions of the type modeled here should arise only in cooling flows of central pressure less than about 1 billion ergs/cu cm and should extend only over the inner regions of the cluster.

Voit, G. Mark↗

Yonkers Urban Development: Utilizing NASA Earth Observations to Identify Environmental and Social Drivers of Urban Heat Vulnerability and Model Urban Cooling Interventions in Yonkers, New York

The City of Yonkers, New York, is located directly north of the Bronx in Westchester County and currently hosts a population of nearly 200,000. In response to increasing hot-weather episodes, the risk of heat-related illnesses and mortality is disproportionately affecting neighborhoods in Yonkers historically subjected to race-based housing segregation. NASA DEVELOP collaborated with Groundwork Hudson Valley to determine regions within Yonkers that are experiencing the most intense urban heat island effects, identify and rank sociodemographic and environmental determinants of increasing community-level vulnerability, map these vulnerabilities as a combined vulnerability index, complete a proximity analysis of walkability to local cooling centers and health facility locations, and model potential cooling strategies. The study area consisted of Yonkers, NY and the analyses used data from 2015-2020 (June through August). The project utilized NASA Earth observation products including Landsat 4 and 5 Thematic Mapper (TM), Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), Terra Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). We assessed the benefits of different heat-mitigation scenarios by utilizing the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model. Results from these analyses can be used by Groundwork Hudson Valley, supporting the New York State’s Climate Safe Communities Certifiable Planning Actions, expanding knowledge on the relationship between historic redlining and environmental equity, and informing their Climate Safe Neighborhoods initiative to identify and prioritize mitigation efforts to abate the worst impacts of extreme heat.

Jillian Walechka↗

Transient radiative cooling of an absorbing and scattering cylinder - A separable solution

A cylindrical region filled with absorbing-emitting material is cooled by radiation to surroundings at a much lower temperature. A solution is found showing that, for each set of parameters, the transient radial temperature distribution reaches a fixed shape, although the temperatures are decreasing with time. This 'fully developed' transient region is characterized by having a constant emittance based on instantaneous values of the cylinder heat loss and mean temperature. This emittance depends only on the optical radius of the cylinder and the scattering albedo. The emittance is lower than that for a cylinder at uniform temperature. This arises from the larger local cooling and, hence, reduced temperatures of the outer layers of the cylinder. An examination of this transient emittance provides the ranges of parameters within which the simplification can be made that the cylinder has uniform radial temperature distribution throughout the cooling process.

Siegel, Robert↗

The Yearly Variation in Fall-Winter Arctic Winter Vortex Descent

Using the change in HALOE methane profiles from early September to late March, we have estimated the minimum amount of diabatic descent within the polar which takes place during Arctic winter. The year to year variations are a result in the year to year variations in stratospheric wave activity which (1) modify the temperature of the vortex and thus the cooling rate; (2) reduce the apparent descent by mixing high amounts of methane into the vortex. The peak descent amounts from HALOE methane vary from l0km -14km near the arrival altitude of 25 km. Using a diabatic trajectory calculation, we compare forward and backward trajectories over the course of the winter using UKMO assimilated stratospheric data. The forward calculation agrees fairly well with the observed descent. The backward calculation appears to be unable to produce the observed amount of descent, but this is only an apparent effect due to the density decrease in parcels with altitude. Finally we show the results for unmixed descent experiments - where the parcels are fixed in latitude and longitude and allowed to descend based on the local cooling rate. Unmixed descent is found to always exceed mixed descent, because when normal parcel motion is included, the path average cooling is always less than the cooling at a fixed polar point.

Schoeberl, Mark R.↗

Simulation of a steady-state integrated human thermal system.

The mathematical model of an integrated human thermal system is formulated. The system consists of an external thermal regulation device on the human body. The purpose of the device (a network of cooling tubes held in contact with the surface of the skin) is to maintain the human body in a state of thermoneutrality. The device is controlled by varying the inlet coolant temperature and coolant mass flow rate. The differential equations of the model are approximated by a set of algebraic equations which result from the application of the explicit forward finite difference method to the differential equations. The integrated human thermal system is simulated for a variety of combinations of the inlet coolant temperature, coolant mass flow rate, and metabolic rates. Two specific cases are considered: (1) the external thermal regulation device is placed only on the head and (2) the devices are placed on the head and the torso. The results of the simulation indicate that when the human body is exposed to hot environment, thermoneutrality can be attained by localized cooling if the operating variables of the external regulation device(s) are properly controlled.

Hsu, F. T.↗

A numerical investigation of the severe thunderstorm gust front

The structure of the thunderstorm gust front is investigated by a nonhydrostatic, two-dimensional (x,z) numerical model. In the model, which is dry, the production of negatively buoyant air by evaporation is parameterized via an externally imposed, local-cooling function. This parameterization sustains a steady cold downdraft, which drives the surface outflow and associated gust front. It is shown that two dominant factors influencing gust front structure in the vertical plane are the solenoidal field coincident with the front and surface friction, modeled by means of a simple bulk aerodynamic drag formulation. The circulation theorem is invoked to illustrate how solenoidal accelerations oppose the deceleration by surface friction. After the onset of a downdraft in the model, these opposing tendencies soon reach a balance. Thus, following a brief transient stage, the model gust front exhibits a persistent configuration as it propagates rapidly forward. The essential features of this configuration are examined and compared with both tower observations of gust fronts and laboratory models of gravity currents.

Mitchell, K. E.↗

Some recent coronal line observations of supernova remnants

Observations of optical coronal lines from the supernova remnants Puppis A and N 49 in the Large Magellanic Cloud carried out at Cerro Tololo and the Anglo-Australian Observatory are reported. The eastern section of Puppis A was searched for forbidden Fe X and Fe XIV emissions in order to confirm the previous detection of a lower temperature component of the X-ray source. Strong forbidden Fe XIV emission was detected in one region consistent with the position of the previously observed soft X-ray component, implying a cool localized component, possibly a relatively dense interstellar cloud interacting with the expanding shock front, superimposed on a more extended hotter region. The spectrum of N 49 showed a broad feature at 5303 A, identified with the forbidden Fe XIV line. Predictions of X-ray fluxes assuming a temperature of 2 x 10 to the 6th K and a density behind the shock front of 4/cu cm for hydrogen densities of zero and 10 to the 21st/sq cm lead to the suggestion that X-ray observations of N 49 may prove worthwhile.

Zarnecki, J. C.↗