Modeling and Control of Cascaded Bridgeless Multilevel Rectifier Under Unbalanced Load Conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality.The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to achieve unity power factor using fully controlled hbridge cells. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. A novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization and power factor correction under unbalanced load conditions. Simulation and experimental results validate the models and control method.

Cascaded Bridgeless Rectifier, Power factor analys↗

Ducted Fuel Injection Provides Consistently Lower Soot Emissions in Sweep to Full-Load Conditions

Earlier studies have proven how ducted fuel injection (DFI) substantially reduces soot for low- and mid-load conditions in heavy-duty engines, without significant adverse effects on other emissions. Nevertheless, no comprehensive DFI study exists showing soot reductions at high- and full-load conditions. This study investigated DFI in a single-cylinder, 1.7-L, optical engine from low- to full-load conditions with a low-net-carbon fuel consisting of 80% renewable diesel and 20% biodiesel. Over the tested load range, DFI reduced engine-out soot by 38.1–63.1% compared to conventional diesel combustion (CDC). This soot reduction occurred without significant detrimental effects on other emission types. Thus, DFI reduced the severity of the soot–NO x tradeoff at all tested conditions. While DFI delivered considerable soot reductions in thepresent study, previous DFI studies at low- and mid-load conditions delivered larger soot reductions (>90%) compared to CDC operation at the same conditions. Therefore, the DFI configuration used here has been deemed nonoptimal (in terms of parameters such as the injector-spray and piston geometries), and several improvements are recommended for future studies with high-load DFI. Further, these improvements include employing better spray-duct alignment, a deeper piston bowl with a smaller injector umbrella angle, and a fuel injector that opens and closes faster. The study also suggests future research to make DFI ready for commercialization, such as metal-engine tests to ensure desirable DFI performance over an engine’s complete speed/load map. Overall, this study supports the continued development and commercialization of DFI to meet upcoming emissions regulations for heavy-duty vehicles. Specifically, multicylinder engine experiments and CFD simulations should be utilized to optimize the performance and clarify the full potential of DFI.

33 ADVANCED PROPULSION SYSTEMS↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A Device Under Test (DUT) is excited with a multispectral excitation signal for an excitation time period while the DUT is under a load condition from a load operably coupled to the DUT. A response of the DUT is sampled over a sample time period. The sample time period is configured such that it includes an in-band interval during the excitation time period and one or more out-of-band intervals outside of the in-band interval. A response of the DUT to the load condition during the in-band interval is estimated by analyzing samples of the response from the one or more out-of-band intervals. Adjusted samples are computed by subtracting the estimated load response during the in-band interval from the samples from the in-band interval. An impedance of the DUT is estimated by analyzing the adjusted samples.

Christophersen, Jon P.↗

Comparing Interaction Graphs on Cascading Outages under Different Loading Conditions

Interaction graphs on cascading outages of power systems provide valuable insights into how cascading outages evolve and propagate, and which components and links are critical to the propagation of cascading outages, enabling further development of mitigation strategies to support decision-making. However, the sensitivity of the interaction graph’s topology to the system’s loading condition has not been studied sufficiently. This paper compared interaction graphs under various loading conditions on the Northeastern Power Coordinating Council 140-bus system, and discovers the strong relationships between the graph topology, the cascade size distribution, and the load condition. Accordingly, three representative interaction graphs are constructed and illustrated.

Guo, Zhenping↗

Rotor Magnet Fault Analysis in Permanent Magnet AC Machines Under Load Conditions - All Electric Transportation Systems

This paper studies the performance of a Permanent Magnet (PM) alternating-current (AC) machine when subjected to faults under load conditions. The effect of varying load torques, and unbalances are found to be potential causes of rotor faults, inducing physical magnet defects or broken rotor-PMs. The consequent and immediate impact on the machine quantities is observed through anomalous change in torque-speed characteristics and other vital signatures such as machine back-EMF/flux and motor current signatures (MCS). The present research study develops and illustrates a method to diagnose physical magnet defects (fault) in PMAC machines by estimating the machine torque/back-EMF constant, Ke. The constant Ke is a measure of magnet strength exhibiting the health of rotor PMs, indicative of faults. Advanced research studies and investigations are carried out to establish motor approximations and signature-based analysis as significant viable tools for diagnosing machine faults even under load conditions.

alternating current↗

Performance Analysis of Li-ion Battery Under Various Thermal and Load Conditions

In the recent years, with the rapid advancements made in the technologies of electric and hybrid electric vehicles, selecting suitable batteries has become a major factor. Among the batteries currently used for these types of vehicles, the lithium-ion battery leads the race. Apart from that, the energy gained from regenerative braking in locomotives and vehicles can be stored in batteries for later use for propulsion thus improving the fuel consumption and efficiency. But batteries can be subjected to a wide range of temperatures depending upon the operating conditions. Thus, a thorough knowledge of the battery performance over a wide range of temperatures and different load conditions is necessary for their successful employment in future technologies. In this context, this study aims to experimentally analyze the performance of Li-ion batteries by monitoring the charge–discharge rates, efficiencies, and energy storage capabilities under different environmental and load conditions. Sensors and thermal imaging camera were used to track the environment and battery temperatures, whereas the charge–discharge characteristics were analyzed using CADEX analyzer. The results show that the battery performance is inversely proportional to charge–discharge rates. This is because, at higher charge–discharge rates, the polarization losses increase thus increasing internal heat generation and battery temperature. Also, based on the efficiency and energy storage ability, the optimum performing conditions of the Li-ion battery are 30–40 °C (temperature) and 0.5 C (C-rate).

25 ENERGY STORAGE↗

Mechanical Modeling and Testing of Pouch Cells under Various Loading Conditions

Understanding the mechanical behaviors of batteries is critical to improve battery safety since mechanical failure may directly lead to short-circuits. Nevertheless, mechanical modeling of batteries is challenging since a cell usually contains multiple thin layers with drastically different material properties, and they exhibit different responses under different loading conditions. In this work, we developed a mechanical model for a large-format pouch cell, where the cell is represented by thick shell elements that are not only computationally efficient but also account for different thickness and material properties of individual components. Moreover, the mechanical properties of active materials in electrodes are described by a continuous surface cap model that can capture both compaction and shear deformation modes and can include strain rate effect and damage. Furthermore, to evaluate the model capabilities, we conducted abuse tests under various loading conditions (quasi-static compression, shear and impact). It is shown that the model prediction of load-displacement relationship and failure condition agree with experimental results, which demonstrates that the developed model can capture the mechanical behaviors of a cell in different abuse events. Details of element formulation, material parameters evaluation and test setup are presented. Capabilities, limitations and future directions of model development are also discussed.

25 ENERGY STORAGE↗

A Deterministic and Probabilistic Framework for Forecasting of Time-Series Damage States and Associated End-of-lIfe of a Pressurizer Water Reactor Surge Line under Design-Basis and Grid-Load-Following Loading Conditions

Argonne National Laboratory in support of the Department of Energy’s Light Water Reactor Sustainability (LWRS) program. The present semi-annual report covers the period between May 2018 and September 2018. In this report, we present the work performed to further improve the capability for structural integrity prediction. Part of this work focused on validating a computational fluid dynamics model for modeling thermal stratification. We also present finite element (FE) model based thermal-mechanical stress analysis of a pressurized water reactor (PWR) surge line under grid-load-following loading condition. In addition, we present work related to end-of-life prediction of a PWR surge line based on ASME code and NUREG-6909 deterministic approaches under design-basis and grid-load-following conditions. Our research in this report period also majorly involved with the development of a strategy for probabilistic fatigue life estimation. First, we applied a Weibull probabilistic modeling approach based on end-of-life fatigue data (traditional S~N data under in-air and PWR water conditions) to estimate the probabilistic life for a given strain amplitude. Second, we developed a data analytics based Markov-Chain-Monte-Carlo (MCMC) model for probabilistic modeling of time-series fatigue damage states and the associated probabilistic end-of-life of a component. Unlike the Weibull type approach, the MCMC type may not require a large number of fatigue tests for estimating the end-of-life for given loading and environmental conditions. We demonstrated the use of this framework through symmetric fatigue tests (stress- or strain-ontrolled tests either under in-air or PWR-water conditions) obtained from our earlier experiments. The MCMC model can use base time-series data either obtained from a model or fatigue experiment. Since experimental data are typically more accurate than model-calculated data, we used experiment-based time-series data to demonstrate the MCMC framework. However, when performing a complex experiment is not possible (due to time and costs involved), a model-based approach can be used to generate the time-series data. Similar model-based data are presented in our earlier report (e.g. for cyclic hardening damage states of a PWR surge line under constant amplitude and design-basis loading [1]). However, for the MCMC work in this report, we used experiment-based time-series damage states obtained from fatigue experiments under design-basis and grid-load-following loading conditions. The experimental loading inputs were based on thermal-mechanical FE model results of a typical PWR surge line. Then, we used the experimental time-series damage state data for forecasting the probabilistic time-series damage states and end-of-life of the PWR surge line. Based on this MCMC modeling strategy, and with the assumed loading, environment and thermal-mechanical boundary conditions, we have estimated that a 316SS-pure base metal PWR surge line would survive at least 159 years with zero failure probability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coupled Aero-Hydro-Mechanical Hybrid Simulation Testing of Offshore Wind Turbines Subjected to Operational and Extreme Loading Conditions

Understanding the response of the Offshore Wind Turbine (OWT) subjected to realistic applied loads requires modeling the whole structure including its soil-foundation system. This requires unique and innovative testing facilities. OWT systems experience cyclic and dynamic loading due to wind, wave, current, rotor vibrations (i.e., 1P load) and vibrations caused by the blade shadowing effects (2P/3P loads). These loads are complicated in nature and have varying amplitudes, frequencies, and directions. Investigating the response of the entire OWT system including the soil-foundation system under these complex loading conditions, requires: (1) full understanding of the loading characteristics including: the power take-off mechanical load (1P and 3P), and areo- and hydrodynamic loads that the OWT system is subjected to; (2) testing facility with unique multidirectional loading capabilities that allows for simultaneous application of realistic wind, wave and machine loads, axial gravity loads, and induced overturning moments; and (3) unique and cost-effective testing techniques that allow for accurate analysis of the overall response of the OWT system under realistic conditions such as: Real-Time Hybrid Simulation (RTHS).

17 WIND ENERGY↗

Effect of Domain Size, Boundary, and Loading Conditions on Mechanical Properties of Amorphous Silica: A Reactive Molecular Dynamics Study

Mechanical properties are very important when choosing a material for a specific application. They help to determine the range of usefulness of a material, establish the service life, and classify and identify materials. The size effect on mechanical properties has been well established numerically and experimentally. However, the role of the size effect combined with boundary and loading conditions on mechanical properties remains unknown. In this paper, by using molecular dynamics (MD) simulations with the state-of-the-art ReaxFF force field, we study mechanical properties of amorphous silica (e.g., Young’s modulus, Poisson’s ratio) as a function of domain size, full-/semi-periodic boundary condition, and tensile/compressive loading. We found that the domain-size effect on Young’s modulus and Poisson’s ratio is much more significant in semi-periodic domains compared to full-periodic domains. The results, for the first time, revealed the bimodular and anisotropic nature of amorphous silica at the atomic level. We also defined a “safe zone” regarding the domain size, where the bulk properties of amorphous silica can be reproducible, while the computational cost and accuracy are in balance.

bimodular materials↗

Mechanical Response of Additively Manufactured Stainless Steel 304L Across a Wide Range of Loading Conditions

The mechanical response of additively manufactured (AM) stainless steel 304L has been investigated across a broad range of loading conditions, covering 11 decades of strain rate, and compared with the behaviors of traditional ingot-derived (wrought) material. In general, the AM material exhibits a greater strength and reduced ductility compared with the baseline wrought form. These differences are consistently found from quasi-static and high strain rate tests. A detailed investigation of the microstructure, the defect structure, the phase, and the composition of both forms reveals differences that may contribute to the differing mechanical behaviors. Compared with the baseline wrought material, dense AM stainless steel 304L has a more complex grain structure with substantial sub-structure, a fine dispersion of ferrite, increased dislocation density, oxide dispersions and larger amounts of nitrogen. In-situ neutron diffraction studies conducted during quasi-static loading suggest that the increased strength of AM material is due to its initially greater dislocation density. The flow strength of both forms is correlated with dislocation density through a square root dependence akin to a Taylor-like relationship. Neutron diffraction measurements of lattice strains also correlate with a crystal plasticity finite element simulations of the tensile test. Other simulations predict a significant degree of elastic and plastic anisotropy due to crystallographic texture. Hopkinson tests at higher strain rates $\dot{ε}$ = 500 and 2500 s -1 ) also show a greater strength for AM stainless steel 304L; although, the differences compared with wrought are reduced at higher strain rates. Gas gun impact tests, including reverse ballistic, forward ballistic and spall tests, consistently reveal a larger dynamic strength in the AM material. The Hugoniot Elastic Limit (HEL) of AM SS 304L exceeds that of wrought material although considerable variability is observed with the AM material. Forward ballistic testing demonstrates spall strengths of AM material (3.27 -- 3.91 GPa) that exceed that of the wrought material (2.63 -- 2.88 GPa). The Hugoniot equation-of-state for AM samples matches archived data for this metal alloy.

36 MATERIALS SCIENCE↗

Predicting ductility of Mg/SiCp nanocomposite under multiaxial loading conditions based on unit cell modeling

This article presents an investigation on the ductility of Mg/SiCp under nine different multiaxial loading conditions based on a unit cell (or called representative volumetric element, RVE) finite element model. The constitutive relationship of magnesium matrix is characterized by a model combined Lode angle dependent plasticity model with the CPB06 plasticity model, which is able to describe the tension-compression asymmetry in magnesium matrix. The debonding of the matrix-particle interface and matrix fracture are considered by the modified Mohr-Coulomb (MMC) fracture model. Simulation results show that the interface debonding and subsequent matrix fracture are responsible for the ductility and fracture of nanocomposite. The computational results with parametric studies are compared and well correlated with experimental data, and it finally gives a stress-based full fracture locus of Mg/SiCp nanocomposite.

42 ENGINEERING↗

Mechanical response of HFIR-irradiated M5FRAMATOME cladding under simple and complex loading conditions

This study investigates the mechanical behavior of High Flux Isotope Reactor (HFIR) irradiated M5FRAMATOME cladding under simple and complex loading conditions through axial tensile and reversible cyclic bending. Axial tension specimens were pre-machined prior to HFIR irradiation while cyclic bend specimens were inserted as intact tubes. Tests articles were neutron-irradiated to 4 and 16 dpa, and specimens were tested at ORNL's hotcell facilities. The axial tension tests were conducted under constant displacement control, and the reversible cyclic bend tests were performed using ORNL's Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) apparatus. Results showed that mechanical response of Cr-coated and uncoated M5FRAMATOME cladding were similar and independent of irradiation dose for axial tension tests, while Cr-coated specimens’ reversible cyclic bend behavior differed from uncoated counterparts. For all tests, irradiation temperature showed a significant impact on the mechanical behavior. Below 280°C, all axial tensile specimens whether coated or not behaved similarly. Above 280°C, YS and UTS showed decrease with increasing irradiation temperature. A similar behavior was also observed in cyclic bend tests as well. The mechanical damage during cyclic bend tests was linked to damage accumulation in unirradiated Cr-coated zircaloy-4 specimens, and the effect of irradiation temperature was related to changing characteristics of defect mobility during high temperature irradiation.

Cinbiz, Nedim [ORNL] (ORCID:0000000346268515)↗

In-situ effect in cross-ply laminates under various loading conditions analyzed with hybrid macro/micro-scale computational models

In this article, multi-scale finite element analyses based on three-dimensional (3D) hybrid macro/micro-scale computational models subjected to various loading conditions are carried out to examine the in-situ effect imposed by the neighboring plies on the failure initiation and propagation of cross-ply laminates. A detailed comparative study on crack suppression mechanisms due to the effect of embedded laminar thickness and adjacent ply orientation is presented. Furthermore, we compare the results of in-situ transverse failure strain and strength between the computational models and analytical predictions. Good agreements are generally observed, indicating the constructed computational models are highly accurate to quantify the in-situ effect. Subsequently, empirical formulas for calculating the in-situ strengths as a function of embedded ply thickness and different ply angle between embedded and adjacent plies are developed, during which several material parameters are obtained using a reverse fitting method. Finally, a new set of failure criteria for σ 22 -τ 12 , σ 22 -τ 23 , and σ 11 -τ 12 accounting for the in-situ strengths are proposed to predict laminated composites failure under multi-axial stress states. This study demonstrates an effective and efficient computational technique towards the accurate prediction of the failure behaviors and strengths of cross-ply laminates by including the in-situ effects.

36 MATERIALS SCIENCE↗

A Novel LCC-CLCC Resonant Tuning Network for Light-Load Conditions in Wireless Power Transfer Systems

In wireless power transfer (WPT) systems, voltage and current distortions are observed at the vehicle side rectifier when power flow is from grid to vehicle (G2V) under light load conditions. These distortions can increase switching losses and decrease the overall efficiency of the WPT system. To address this issue, this paper proposes adding a higher value inductor in series with the original LCC tuning network at the vehicle side. However, increasing the series inductance causes the input impedance and phase angle to move away from the resonant frequency. To solve this problem, a capacitor is added in series to tune out the difference between the original and modified inductor values. This series tuning capacitor also improves the power factor and brings the input impedance and phase angle back to the resonant frequency. The traditional LCC-LCC and proposed LCC-CLCC WPT systems are compared and analyzed analytically, and simulated in a MATLAB/Simulink environment to verify parameters such as efficiency and power transfer capacity. An experimental prototype is implemented and compared with the simulation. The obtained results confirm the validity of the proposed method.

Harave, Sudarshan↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extraction of Nitric Acid and Uranium with DEHiBA under High Loading Conditions

We report the mechanism by which high concentrations (1.5 M in n-dodecane) of N,N-di-2-ethylhexylisobutyramide (DEHiBA) extracts HNO 3 and UO 2 (NO 3 ) 2 is under examination. Most prior studies have examined the extractant and the mechanism at a concentration of 1.0 M in n-dodecane, however under the higher loading conditions that can be achieved by a higher concentration of extractant this mechanism could change. Increased extraction of both nitric acid and uranium is observed with an increased concentration of DEHiBA. The mechanisms are examined by thermodynamic modeling of distribution ratios, 15 N NMR, and FTIR spectroscopy coupled with Principal Component Analysis (PCA). Speciation diagrams produced through thermodynamic modeling have been qualitatively reproduced through PCA of the FTIR spectra. The predominant extracted species of HNO 3 (DEHiBA), HNO 3 (DEHiBA) 2 , and UO 2 (NO 3 ) 2 (DEHiBA) 2 are in good agreement with prior literature reports for 1.0 M DEHiBA systems. Evidence for an additional species of either UO 2 (NO 3 ) 2 (DEHiBA) or UO 2 (NO 3 ) 2 (DEHiBA) 2 (HNO 3 ) also contributing to the extraction of uranium species is given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and control of cascaded bridgeless multilevel rectifier under unbalanced load conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality. The complete design process of the proposed converter is developed step by step in order to meet all the desired objectives. The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to mathematically derive requirements for the number of partially controlled and fully controlled H-bridges in the proposed H-bridge converter. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. After exploring various well-established control methods, a novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization, power factor correction, and elimination of zero crossing current distortion under both balanced and unbalanced load conditions. The converter can also be used for reactive power compensation in a grid tied power system if a sufficient number of fully controlled H-bridge modules are included. Processor-In-the-Loop (PIL) simulation has been the utilized to validate the performance of discrete control structure. Simulation and experimental results validate the models and control method.

24 POWER TRANSMISSION AND DISTRIBUTION↗