Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solving Unit Commitment Problems with Demand Responsive Loads

This work focuses on using variations of the Frank-Wolfe (FW) algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the IEEE Reliability Test System that the timeseries of demand responsive load decisions obtained through our approach are near optimal and describe how large-scale parallel implementations of our approach can be highly computationally efficient.

demand response↗

Assessment of Optimal Flexibility in Ensemble of Frequency Responsive Loads

Potential of electrical loads in providing grid ancillary services is often limited due to the uncertainties associated with the load behavior. A knowledge of the expected uncertainties with a load control program would invariably yield to better informed control policies, opening up the possibility of extracting the maximal load control potential without affecting grid operations. In the context of frequency responsive load control, a probabilistic uncertainty analysis framework is presented to quantify the expected error between the target and actual load response, under uncertainties in the load dynamics. A closed-form expression of an optimal demand flexibility, minimizing the expected error in actual and committed flexibility, is provided. Analytical results are validated through Monte Carlo simulations of ensembles of electric water heaters.

Kundu, Soumya↗

Solving Unit Commitment Problems with Demand Responsive Loads: Preprint

This paper focuses on using variations of the Frank-Wolfe algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the RTS-GMLC test system that the time series of demand responsive load decisions obtained through our approach are near optimal and provide details regarding how large scale parallel implementations of our approach can be highly computationally efficient.

demand response↗

Evaluating the Impact of Price-Responsive Load on Power Systems Using Integrated T&D Simulation: Preprint

This paper explores the advantages and challenges of simulating price-responsive load (PRL) interactions with large-scale power systems using integrated transmission and distribution (T&D) models. This analysis uses the Integrated Grid Modeling System (IGMS) software to capture 'ISO-to-appliance' simulations using a synthetic T&D model built on the PJM 5 Bus transmission network with multiple full-scale taxonomy feeders that include physics-based models of thousands of PRLs. The results show substantial differences in the impacts of PRLs between integrated T&D and transmission-only (T-only) models. Similarly differences are observed between the price response of individual distribution feeders and the corresponding transmission bus in the integrated T&D simulations, which cannot be captured in T-only simulations. Experiments include both traditional price responsive load reductions and price-driven load increases during low net demand periods driven by high daytime generation from distributed generation-based photovoltaics (DGPV).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load responsive multilayer insulation performance testing

Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

42 ENGINEERING↗

Nonsteady Load Responses to Daytime Atmospheric Turbulence Eddies on the DOE 1.5 MW Wind Turbine at NREL

Field data collected from the NREL/GE 1.5MW wind turbine (WT) and met tower (MetT) at the NREL Wind Technology Center near Boulder, CO June-October 2018 were analyzed to quantify the impacts of turbulence eddies on the load responses measured from sensors on the main shaft, blade and tower. The passage of individual mountain-generated eddies from the met tower to the WT were critically determined by correlating the optimal time shifts in signal between MetT and nacelle anemometers with mean advection time. Loading responses from mountain eddy passage were compared with atmospheric eddies from the north/south, unimpeded by the mountains, and found to be similar. Whereas time variations in torque were highly correlated with time changes in horizontal eddy velocity, the out-of-plane bending moments on the main shaft (directly forcing the main bearing) were uncorrelated with horizontal eddy velocity. This result is consistent with a previous LES study indicating that the main bearing is forced by asymmetrical interactions between the WT rotor and turbulence eddies, while power fluctuations respond primarily to advective eddy velocity. Surprisingly, the nacelle anemometer produced statistics very similar to the MetT.

ENGINEERING,WIND ENERGY↗

Nonsteady Load Responses of Wind Turbines to Atmospheric and Mountain-Generated Turbulence Eddies, With Impacts on the Main Bearing: A Validation Study

Previous computational and field experiments identify three characteristic time scales in the aerodynamic responses of utility-scale wind turbine loads to atmospheric boundary layer (ABL) turbulence: a 30-90 second time scale for the passage of high/low speed "streaks" through the rotor plane, the blade and rotor rotation time scales (approximately 1 to 5 seconds), and a sub-second time scale created by blade rotation through gradients within eddy coherent structure. In the current study we compare aerodynamic load responses from daytime ABL turbulence quantified with large-eddy simulation and a actuator line model of the NREL 5 MW wind turbine with analysis of field data from the NREL/GE 1.5 MW wind turbine 5 kilometers east of the Rocky Mountain Front Range in Colorado. In addition, we contrast the responses to the passage of the mountain-generated eddies embedded within the westerly winds with the ABL eddies embedded within northerly/southerly winds. These analyses are in context with the nonsteady forcing of the main bearing by the aerodynamic generation of nontorque bending moments on the main shaft. Potentially relevant to main bearing failure mechanisms, both computational and field data show that the magnitudes of turbulence-generated nontorque bending moments, that we show generate nonsteady force on the main bearing, are of order, and often larger than, torque (which underlies power). However, the temporal variations in these two responses are uncorrelated, implying that the aerodynamic mechanisms that drive power and main bearing response are fundamentally different. We find this to be the case in the field with both mountain-generated eddies (westerly winds) and ABL-generated eddies (northerly/southerly winds). Whereas the time and length scales are comparable, the mountain eddies were somewhat more energetic than the northerly/southerly ABL eddies. Interestingly, however, the fluctuations in nontorque bending moment that force the main bearing were found to be stronger when forced by the ABL eddies than the mountain eddies. The field studies validate the key results from the computational study and show even stronger response in the nontorque bending moment than in the computer simulations. In all cases, the torque and nontorque bending moments are temporally uncorrelated, torque and power are driven by time variations in rotor-averaged horizontal wind velocity and nontorque bending moments are driven by time changes in the degree of nonuniformity in the distribution of velocity over the rotor plane. Thus the results generalize the mechanisms underlying nonsteady aerodynamic forcing to classes of turbulence eddy types with strength of order or stronger than ABL eddies with transverse scale of order the wind turbine rotor. These include atmospheric turbulence eddies, topography-generated turbulence eddies and, by extension, impacts of turbine-wake-scale turbulence eddies on downstream wind turbine rotors.

17 WIND ENERGY↗

Frequency threshold determination for frequency-responsive load controllers

Systems, methods, and computer media for managing frequency response in a power grid are provided herein. Individual grid-connected electrical devices can be turned on and/or off by corresponding frequency-responsive load controllers when frequency deviations beyond a threshold are detected. Each controller selects, for the corresponding electrical device, a frequency threshold from available frequencies in a frequency range. If the selected frequency falls within a deadband frequency range, then the controller sets the frequency threshold to a frequency outside of the deadband (e.g., to a closest available frequency outside of the deadband). On a system-wide level, this approximates a uniform distribution of frequency thresholds over the entire frequency range, including the deadband, and achieves the proper power-to-frequency relationship for grid stability. A supervisory coordinator can determine the frequency range from which a frequency threshold is selected based on aggregated power information for devices and controllers throughout the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonsteady Load Responses to Mountain-Generated Turbulence Eddies on the DOE 1.5 MW Wind Turbine at the National Wind Technology Center

Field data collected from the NREL/GE 1.5MW wind turbine and met tower at the NREL Wind Technology Center near Boulder, Colorado from June-October 2018 were analyzed to quantify the impacts of turbulence eddies on the load responses measured from sensors on the main shaft, blade and tower. The passage of individual mountain-generated eddies from the met tower to the wind turbine were critically determined by correlating the optimal time shifts in signal between met tower and nacelle anemometers with mean advection time. Loading responses from mountain eddy passage were compared with atmospheric eddies from the north/south, unimpeded by the mountains, and found to be similar. Whereas time variations in torque were highly correlated with time changes in horizontal eddy velocity, the out-of-plane bending moments on the main shaft (directly forcing the main bearing) were uncorrelated with horizontal eddy velocity. This result is consistent with a previous LES study indicating that the main bearing is forced by asymmetrical interactions between the rotor and turbulence eddies, while power fluctuations respond primarily to advective eddy velocity. Surprisingly, the nacelle anemometer produced statistics very similar to the met tower.

ENGINEERING,WIND ENERGY↗

Sparse Control Synthesis for Uncertain Responsive Loads With Stochastic Stability Guarantees

In this report, recent studies have demonstrated the potential of flexible loads in providing frequency response services, predominantly due to their availability and cost-effectiveness. However, uncertainty and variability in various weather-related and end-use behavioral factors often impact the reliability of demand-side control performance. This work addresses this problem with the design of a demand-side control to achieve frequency response under load uncertainties. Our approach involves modeling the load uncertainties via stochastic processes that appear as both multiplicative and additive in the power system dynamics. Recently developed mean square exponential stability (MSES) results for continuous-time linear stochastic systems are applied to pose the control synthesis problem which results in an LMI-based optimization problem. Additional costs and constraints are added to the LMI-based controller synthesis to ensure MSES, improve closed-loop transient performance, maximize tolerable uncertainties, and promote sparsity in the controller. Additionally, the fundamental limitations between the tolerable uncertainties and control efforts while ensuring MSES are discussed. Further, the control synthesis problem for the case of the full-state measurement is generalized to the case of partial-state measurements. The proposed control synthesis is illustrated on an IEEE 39 bus system with rigorous studies to demonstrate the role of sparsity, closed-loop transient performance, tolerable uncertainties, and control efforts while ensuring MSES and achieving frequency response.

42 ENGINEERING↗

Evaluating the Impact of Price-Responsive Load on Power Systems Using Integrated T&D Simulation

This paper explores the differences between simulating price-responsive load (PRL) interactions with power systems using integrated transmission and distribution (T&D) models and transmission-only (T-only) models. This analysis uses the Integrated Grid Modeling System (IGMS) software to capture 'ISO-to-appliance' simulations using a synthetic T&D model built on the PJM 5-Bus transmission network with multiple full-scale taxonomy feeders that include physics-based models of thousands of customers and PRLs. The results show important differences in the impacts of PRLs between integrated T&D and T-only models. Experiments with the synthetic integrated T&D dataset demonstrated that integrated T&D simulation revealed notably larger differences between the PRL and no-PRL cases for load, and prices compared to T-only simulation. Similarly, differences are observed between the price response of individual buildings and distribution feeders and the corresponding transmission bus in the integrated T&D simulations, which are difficult to capture in traditional T-only simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discrete sensing and actuation in a simulation model of frequency responsive loads

Loads acting autonomously on a local frequency signal can improve the response of a power system to sudden changes in supply, demand, or both. In this paper we address the use of load for regulating frequency by using feedback control. We extend prior research that focused on continuous proportional control, whereby one assumes that the load responds instantaneously, continuously, and in direct proportion to the changing frequency. However, sensors employed in any practical system have a finite sensitivity which introduces quantization effects into the control. As a result, a critical factor in the design of such a control is the relationship between the sensitivity of the sensor and the gain of the actuator. To study this issue, our model is constructed in two parts. The continuous dynamics of the power system is coupled to discrete event models of the sensors by state events that describe the detection points available to them. The quantized signals from the sensors are transformed by the actuators into discrete changes of load which, in turn, change the frequency and thereby complete the control loop. We illustrate the model with a scenario that involves a sudden, unanticipated change in load and the combined response of the control and power system to recover from the event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilizing grid–supportive load response to shape resilient frequency control of the power grid

The increasing penetration of renewable energy sources and the retirement of conventional generation units have decreased system inertia, making power systems more vulnerable to resilience and stability issues. To address this problem, this paper proposes a novel approach using grid-supportive loads (GSLs) to provide a fast and concise primary frequency response and a deep deterministic policy gradient agent-based secondary controller to restore the system frequency to the nominal value. The proposed method is evaluated on the single-area and multi-area test systems. The simulation results demonstrate that using GSLs enhances the power system's stability and resilience. Compared to conventional controllers, the frequency nadir is improved with GSLs. Additionally, the proposed method effectively enhances resilience even with high penetration. These findings indicate that the proposed approach can improve the resilience and stability of power systems and provide a promising solution for future power systems. The results of this study underscore the importance of utilizing innovative approaches to enhance the stability and resilience of power systems in the context of high penetration of renewable energy sources and the retirement of conventional generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Loads Response That is Due to Wake Steering on a Pair of Utility-Scale Wind Turbines

The goal of this report is to present the resulting turbine loads of a full-scale wind turbine wake steering field campaign. In this experiment, wake steering controls were applied to an upwind turbine (T2) and the downwind turbine (T3) was instrumented to measure mechanical loads. The test subjects (T2 & T3) were GE 1.5SLE CWE turbines located on a wind farm with a prevailing wind direction coming from the northwest. The data collection strategy involved toggling the wake steering controls of T2 between on and off. This resulted in two databases (baseline and wake steered) with similar turbulence intensities. Valid data was extracted and processed. The analysis involved scaling data to engineering units, applying coordinate transformations where applicable, calculating 10-minutes statistics, and calculating damage equivalent loads (DELs) to assess fatigue. Figures are shown as statistics and DELs binned by wind speed with supplemental scatter plots provided in the appendices. Results between the baseline and wake steered databases were compared. Overall, the binned statistics showed minimal differences in loading between the two cases. However, the DELs of the wake steered case were observed to be consistently smaller than the baseline for most of the turbine components. A potential for future work was recognized based on the findings of this report. Some areas of further study include an analysis for more granular loads sensitivity to different yaw offset angles and rotor wake overlap, an in-depth comparison of loads between the upwind and downwind turbines, and further fatigue analysis to quantify differences observed in this experiment.

17 WIND ENERGY↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids with Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗