Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Biota Modeling in EPA’s Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level tools that set forth Environmental Protection Agency’s (EPA) recommended approaches, based upon currently available information with respect to risk assessment, for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has a residential gardening scenario and subsistence farmer exposure scenarios that require modeling of the transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC exposure scenarios. Recent improvements have been made in the biota modeling for these calculators, including newly derived biota intake rates, more comprehensive soil mass loading factors (MLFs), and more comprehensive soil to tissue transfer factors (TFs) for animals and soil to plant transfer factors (BV’s). New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

54 ENVIRONMENTAL SCIENCES↗

Biota Modeling in EPA’s Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level risk assessment tools that set forth the Environmental Protection Agency’s (EPA) recommended approaches and currently available risk assessment guidance for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The environmental screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has residential gardening and subsistence farmer exposure scenarios that model transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC calculators. Recent improvements in the biota modeling for these calculators include newly derived biota intake rates, enhanced soil mass loading factors (MLFs), and more comprehensive soil to plant transfer factors (BV’s) and soil to tissue transfer factors (TFs) for animals. New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

54 ENVIRONMENTAL SCIENCES↗

A load factor formula

The ultimate test of a load factor formula is experience. The chief advantages of a semi rational formula over arbitrary factors are that it fairs in between points of experience and it differentiates according to variables within a type. Structural failure of an airplane apparently safe according to the formula would call for a specific change in the formula. The best class of airplanes with which to check a load factor formula seems to be those which have experienced structural failure. Table I comprises a list of the airplanes which have experienced failure in flight traceable to the wing structure. The load factor by formula is observed to be greater than the designed strength in each case, without a single exception. Table II comprises the load factor by formula with the designed strength of a number of well-known service types. The formula indicates that by far the majority of these have ample structural strength. One case considered here in deriving a suitable formula is that of a heavy load carrier of large size and practically no reserve power.

Miller, Roy G↗

Instantaneous mesh load factor ( K γ ) measurements in a wind turbine gearbox using fiber-optic strain sensors

The mesh load factor, K γ , describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K γ is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.

17 WIND ENERGY↗

SAGAbg. I. A Near-unity Mass-loading Factor in Low-mass Galaxies via Their Low-redshift Evolution in Stellar Mass, Oxygen Abundance, and Star Formation Rate

Measuring the relation between star formation and galactic winds is observationally difficult. In this work we make an indirect measurement of the mass-loading factor (the ratio between the mass outflow rate and star formation rate) in low-mass galaxies using a differential approach to modeling the low-redshift evolution of the star-forming main sequence and mass–metallicity relation. We use Satellites Around Galactic Analogs (SAGA) background galaxies, i.e., spectra observed by the SAGA Survey that are not associated with the main SAGA host galaxies, to construct a sample of 11,925 spectroscopically confirmed low-mass galaxies from 0.01 ≲ z ≤ 0.21 and measure auroral line metallicities for 120 galaxies. The crux of the method is to use the lowest-redshift galaxies as the boundary condition of our model, and to infer a mass-loading factor for the sample by comparing the expected evolution of the low-redshift reference sample in stellar mass, gas-phase metallicity, and star formation rate against the observed properties of the sample at higher redshift. We infer a mass-loading factor of η m = $0.92^{+1.76}_{-0.74}$, which is in line with direct measurements of the mass-loading factor from the literature despite the drastically different sets of assumptions needed for each approach. While our estimate of the mass-loading factor is in good agreement with recent galaxy simulations that focus on resolving the dynamics of the interstellar medium, it is smaller by over an order of magnitude than the mass-loading factor produced by many contemporary cosmological simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Nailing the Peak: City-Scale, Building-Specific Load Factor and Contribution to a Utility’s Hour of Critical Generation

Maintaining electrical generation assets to meet peak demand increases the cost of providing electricity to a country’s buildings and insufficient assets can result in power outages. In order to keep reliable electricity costs low for consumers and demand charges low for utilities, there exist markets and financial incentives for limiting consumption during peak demand.The team has partnered with an electrical distributor servicing a 1,390 km2 area and 178,368 buildings with the aim of using urban-scale building energy modelling to inform business decisions necessary for the operation of their electric grid. A suite of software has been developed that allows the scalable creation of a “digital twin” for all buildings in the utility’s service area. This virtual utility area is analysed for targeted deployment of new technologies or policies to assess building-specific savings, effects on critically-loaded grid infrastructure (e.g. feeders, substations), and aggregated impact to utility-scale operations.This work leverages 15-minute data from each building to compare actual and simulated monthly peak-hour demand and assessment of the load factor for each building. Findings include market characterization via clustering of relative energy use profiles for ~180,000 buildings as well as simulation-informed savings opportunities indicating residential load factors of 0.17, commercial load factors of 0.2-0.4 depending on year of construction, and general load factors of 0.16-0.5 depending on building type.

New, Joshua↗

Load Factor and Unserved Energy Webinar

This presentation consists of slides from a webinar given on October 25, 2019. The slides give an overview of load factor forecasting and how it can be incorporated into energy and power demand forecasts, with a special eye towards accounting for unserved energy. It includes case studies from other countries, highlighting how load factor is used in their individual load forecasts. The slides then review and compare various load forecasts for Pakistan's electricity grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A piloted simulation investigation of the normal load factor and longitudinal thrust required for air-to-air acquisition and tracking

A piloted simulation study was performed by the U.S. Army Aeroflighydynamics Directorate to develop insight into the maneuverability requirements for aggressive helicopter maneuvering tasks such as air-to-air combat. Both a conventional helicopter and a helicopter with auxiliary thrust were examined. The aircraft parameters of interest were the normal and longitudinal load factor envelopes. Of particular interest were the mission performance and handling qualities tradeoffs with the parameters of interest. Two air-to-air acquisition and tracking tasks and a return-to-cover task were performed to assess mission performance. Results indicate that without auxiliary thrust, the ownship normal load factor capability needs to match that of the adversary in order to provide satisfactory handling qualities. Auxiliary thrust provides significant handling qualities advantages and can be substituted to some extent for normal load factor capability. Auxiliary thrust levels as low as 0.2 thrust/weight can provide significant handling qualities advantages.

Whalley, Matthew S.↗

Calculated Normal Load Factors on Light Airplanes Traversing the Trailing Vortices of Heavy Transport Airplanes

Results are presented of normal-load-factor calculations made for a lightnormal-category airplane and a light transport-category airplane traversing the trailing vortices generated by each of three heavy transport airplanes. With each light airplane, the normal load factors were determined for several penetration paths lying i n a plane perpendicular to the trailing vortices and for three center-of-gravity locations and velocities. Also determined for the light normal-category airplane were the elevator deflections required to maintain 1 g flight and the vertical displacements of the airplane from the prescribed penetration paths while transversing the vortices.

McGowan, William A.↗

Cold-air investigation of first stage of 4-1/2-stage, fan drive turbine with average stage-loading factor of 4.66

The design procedure and the development of the blading geometry for the 4 and 1/2 stage turbine are discussed. Results obtained with the first stage, operated as a single stage turbine, are presented. A free vortex design meets the design requirements without incurring problems such as excessive turning, negative reaction, or high Mach number. Cold air tests of the single stage turbine showed that the turbine developed design work (stage loading factor of 5.26) at an efficiency of 0.86, which was the efficiency predicted by a reference method. The mass flow at this condition was 0.88, which occurred at design speed and a pressure ratio of 1.407, corresponding to a stage loading factor of 4.35. The efficiency at this condition was 0.003 higher than that predicted by the reference method.

Whitney, W. J.↗

Experimental investigation of a 4 and 1/2 stage turbine with very high stage loading factor. 2: Turbine performance

The experimental test program results of a 4 1/2-stage turbine with a very high stage loading factor are presented. A four-stage turbine was tested with and without outlet turning vanes. The 4 1/2-stage turbine achieved a design point total-to-total efficiency of 0.853. The outlet turning vane design point performance was 0.4 percent of the overall 4 1/2-stage turbine efficiency. Tests were conducted at various levels of Reynolds number and indicated decreases in turbine efficiency and equivalent weight flow with decreasing Reynolds number.

Walker, N. D.↗

Cold-air investigation of a 4 1/2 stage turbine with stage-loading factor of 4.66 and high specific work output. 2: Stage group performance

The stage group performance of a 4 1/2 stage turbine with an average stage loading factor of 4.66 and high specific work output was determined in cold air at design equivalent speed. The four stage turbine configuration produced design equivalent work output with an efficiency of 0.856; a barely discernible difference from the 0.855 obtained for the complete 4 1/2 stage turbine in a previous investigation. The turbine was designed and the procedure embodied the following design features: (1) controlled vortex flow, (2) tailored radial work distribution, and (3) control of the location of the boundary-layer transition point on the airfoil suction surface. The efficiency forecast for the 4 1/2 stage turbine was 0.886, and the value predicted using a reference method was 0.862. The stage group performance results were used to determine the individual stage efficiencies for the condition at which design 4 1/2 stage work output was obtained. The efficiencies of stages one and four were about 0.020 lower than the predicted value, that of stage two was 0.014 lower, and that of stage three was about equal to the predicted value. Thus all the stages operated reasonably close to their expected performance levels, and the overall (4 1/2 stage) performance was not degraded by any particularly inefficient component.

Whitney, W. J.↗

Preliminary Study of Applied Load Factors in Bumpy Air

Theoretical relations involved in the study are reviewed to furnish a basis upon which experimental data can be properly analyzed. The structure of the atmosphere in relation to the load-factor problem is briefly discussed, and the acceleration data obtained on a number of flights with various airplanes are presented and analyzed to the extent that the results are applicable to n=any airplane.

Rhode, Richard V↗

Recruitment of the cohesin loading factor NIPBL to DNA double-strand breaks depends on MDC1, RNF168 and HP1{gamma} in human cells

Highlights: {yields} NIPBL is recruited to DSBs. {yields} Localization of NIPBL to DSBs is regulated by MDC1 and RNF168. {yields} HP1{gamma} is required for NIPBL accumulation at DSBs. -- Abstract: The cohesin loading factor NIPBL is required for cohesin to associate with chromosomes and plays a role in DNA double-strand break (DSB) repair. Although the NIPBL homolog Scc2 is recruited to an enzymatically generated DSB and promotes cohesin-dependent DSB repair in yeast, the mechanism of the recruitment remains poorly understood. Here we show that the human NIPBL is recruited to the sites of DNA damage generated by micro-irradiation as well as to the sites of DSBs induced by homing endonuclease, I-PpoI. The recruitment of NIPBL was impaired by RNAi-mediated knockdown of MDC1 or RNF168, both of which also accumulate at DSBs. We also show that the recruitment of NIPBL to the sites of DNA damage is mediated by its C-terminal region containing HEAT repeats and Heterochromatin protein 1 (HP1) interacting motif. Furthermore, NIPBL accumulation at damaged sites was also compromised by HP1{gamma} depletion. Taken together, our study reveals that human NIPBL is a novel protein recruited to DSB sites, and the recruitment is controlled by MDC1, RNF168 and HP1{gamma}.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗