Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lithium vapor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal Response of a Lithium Vapor Divertor to Cyclical Operation

The lithium vapor divertor concept is being developed as a method to achieve detached divertor conditions in a tokamak while minimizing impurity radiation losses from the core plasma. SOLPS-ITER modeling has previously been used to identify some of the geometric constraints and required lithium evaporation rate of a lithium vapor divertor in a medium-sized tokamak during steady-state operation. Here an updated conceptual design based on these operating requirements is introduced and the thermal response of the system is modeled during cyclical operation, consistent with operation in a short-pulse tokamak. Controllability of the temperature of the lithium capillary porous system (CPS) is achieved by adopting a design where there is no line-of-sight for radiation from the plasma to reach the heated CPS surface. Operational strategies to minimize the amount of lithium evaporated between plasma discharges while achieving steady evaporation rates during plasma discharges are discussed and modeled here. The optimal feedforward control strategy demonstrated in this work is to ramp up the temperature of the evaporator as quickly as possible immediately before a plasma discharge and then reduce the heating to match the desired steady-state net evaporation rate just before the plasma discharge begins, allowing the thermal inertia of the system to stabilize the evaporation rate during the first second of the plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of gas injection location on a lithium vapor box divertor in NSTX-U

Abstract The lithium vapor box divertor is a proposed divertor design that will minimize contamination of the upstream plasma in a fusion device, while also ensuring protection of the target. In this design lithium is evaporated near the target by high temperature lithium surfaces, dissipating the plasma heat flux. The lithium vapor box has been predicted via the fluid-kinetic code scrape off layer plasma simulator (SOLPS-ITER) to achieve low ( n L i / n e ∼ 0.05) upstream concentrations of lithium and low target heat fluxes. Here we compare two choices of deuterium gas puff location using SOLPS-ITER, the private flux region (PFR) and the common flux region (CFR), and find significant differences in the contamination level required to reach an acceptable target heat flux (defined here as q tar max ⩽ 10 MW m −2 ). Deuterium gas puffing from the PFR is seen to better reduce upstream lithium contamination. The difference in puffing location is seen to cause changes in the upstream flow of lithium ions. The PFR puff, having better access to the separatrix, can better reduce the upstream-directed flow of lithium near the separatrix which is the primary source of contamination due to a large thermal force in this region. Puffing from the CFR, partially due to inefficacy at reducing separatrix lithium flow, has higher lithium concentration within the plasma. Solutions that reduce the heat flux to below 10 MW m −2 have a range of lithium concentrations between n L i / n e ∼ 0.01–0.12 depending on puff intensity, location, evaporator temperature and recycling at the various plasma facing components. The efficacy of the puffs is tested for sensitivity to deuterium recycling coefficient at the target, evaporators, and main chamber walls. A CFR located puff is found to be more dependent on the recycling coefficients used than a PFR located puff. regardless of the set of recycling coefficients chosen, PFR puffing achieves lower lithium contamination than CFR puffing for a given heat flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of lithium vapor box divertor evaporator location on NSTX-U using SOLPS-ITER

Commercial fusion reactors will be faced with extremely high divertor target heat fluxes that will require mitigation. Simulations of detachment in an NSTX-U scenario projected to have 92 MW/m 2 unmitigated peak target heat flux are presented, which reaches sub-10 MW/m 2 target heat flux using a highly dissipating lithium vapor box divertor design. The lithium vapor box is a detached divertor design which employs lithium vapor evaporation and condensation to contain lithium below the X-point. Previous SOLPS modeling has indicated a lithium vapor box can reduce the heat flux down to 10 MW/m 2 via simultaneous evaporation from the Private Flux Region (PFR) and the Common Flux Region (CFR) sides of the vapor box. It is found here that PFR evaporation has improved access to the separatrix leading to significantly more efficient power dissipation than CFR evaporation. Simulations of target evaporation with an evaporation distribution that is self-consistent with the temperature of a Capillary Porous System with Fast flowing liquid lithium (CPSF) could reach n Li / n e ~ 0.025-0.030 at the Last Closed Flux Surface (LCFS) depending on the liquid metal flow speeds and lithium sputtering yield, while PFR-side evaporation can reach acceptable heat fluxes with n Li / n e ~ 0.038 at the LCFS. However, PFR evaporator performance can be improved if the target is allowed to be hot enough such that it reflects lithium, reaching n Li / n e ~ 0.028 and reducing required lithium evaporation. Ultimately PFR evaporation and target evaporation are found to have similar ability to produce acceptable heat flux solutions with minimal upstream concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variations in lithium vapor cave performance predictions due to radial transport and recycling assumptions

The lithium vapor cave is a detached divertor design that uses a single private flux region baffle to contain a dense cloud of lithium vapor to dissipate heat flux. Plasma flows are created via fuel gas puffing in order to minimize lithium contamination of the main plasma. Significant modeling using the 2D edge code SOLPS-ITER has already been performed, predicting that sufficient target heat flux reductions (q$^{max}_{Target}$ MW m −2 ) with ( $n$ Li /$n$ e ) LCFS < 0.05 is possible in a case with 90 MW m −2 unmitigated heat flux in NSTX-U. Low heat flux and low upstream concentration was found with a variety of combinations of divertor geometries, target recycling coefficients, upstream plasma parameters, lithium evaporation locations and deuterium fueling locations, with variations in performance found for each design choice. However, the most universal uncertainty of SOLPS-ITER simulations has until now remained unaddressed systematically, namely the cross-field anomalous particle and heat diffusivities. This article aims to bound the uncertainty in lithium concentration prediction as a result of the assumed deuterium cross-field transport and recycling. For the simulations presented here, a factor of 2.1 increase in the upstream lithium density prediction across a factor of four decrease to the assumed deuterium radial particle diffusivity is found. This result is compared across different assumed deuterium recycling coefficients, known to reduce with lithium injection. Upstream lithium density is found to vary by a factor of 2.4 across a feasible range of recycling coefficients at similar $n$$^{OMP,sep}_{e}$.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Molecular Simulation of Lithium Carbonate Reactive Vapor–Liquid Equilibria Using a Deep Potential Model

We developed a first-principles machine learning model for the reactive vapor–liquid phase behavior of molten Li 2 CO 3 . The model was trained on ab initio electronic density functional theory data using the Deep Potential (DP) methodology, and its accuracy was evaluated by comparing model predictions of density and viscosity to experimental measurements. Direct coexistence simulations with the DP model over time scales of tens of nanoseconds were used to observe equilibrium dissociation of Li 2 CO 3 into CO 2 residing primarily in the vapor phase and Li 2 O which remains dissolved in the liquid. The simulations covered a range of temperatures, overall system sizes, and vapor-to-liquid volume ratios. Results were analyzed in terms of the observed chemical composition of the liquid and vapor phases, product structure, and CO 2 partial pressures. In addition, we calculated equilibrium constants for the dissociation reaction by assuming ideal-solution behavior for the liquid. As expected on the basis of thermodynamic arguments and prior experiments for this system, the observed partial pressure of CO 2 in the gas phase depends on both the temperature and the ratio of vapor to liquid volumes, while the calculated equilibrium constants only depend on temperature. DP model predictions for the equilibrium constant of the reaction are generally consistent with the available experimental measurements. Furthermore, the present study establishes the validity of the DP methodology for the description of reactive, multiphase equilibria from first principles, with possible applications to many other systems of scientific and technological interest even in the absence of relevant experimental measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spherical tokamak physics research in preparation for the operation of NSTX-U

The National Spherical Torus Experiment Upgrade (NSTX-U) is preparing to resume operation, representing a crucial step toward realizing compact, cost-effective fusion pilot plants. In advance of this, extensive modeling and data analysis have been conducted to advance the physics basis for low-aspect-ratio, high-performance plasma regimes, focusing on three core objectives: confinement and stability, power and particle handling, and steady-state operation. Significant progress has been made in understanding the electron temperature flattening in high-β plasmas, which is shown to be driven by a complex interplay of magnetohydrodynamic instabilities (e.g. non-resonant infernal modes), fast-ion-driven Alfvén eigenmodes, and electron and ion-scale micro-instabilities, particularly Kinetic Ballooning Modes (KBMs), whose destabilization is strongly dependent on parallel magnetic field fluctuations (δB ∥ ). Furthermore, a new gyrokinetic critical pedestal model was developed, accurately predicting pedestal structure by identifying KBMs as the primary stability limit, offering a critical constraint for future high-confinement scenarios. To address the challenge of high heat flux, novel liquid lithium plasma-facing components were modeled. The analysis confirmed that lithium vapor shielding is a self-regulating mechanism for heat mitigation, while also emphasizing that strong main ion parallel flow is essential to minimize core lithium contamination. Finally, progress toward steady-state operation was anchored by developing the required physics basis and control tools. This includes predictive modeling for reversed magnetic shear sustainment, demonstrating that magnetic island-induced bootstrap current reduction is negligible in STs, and advancing real-time control and disruption avoidance capabilities. The development of high-speed surrogate models (e.g. MMMNet) provides computationally efficient tools vital for non-inductive scenario optimization and integrated, low-disruptivity operations planned for NSTX-U.

NSTX-U↗

Chemical Vapor Transformation of Lithium Metal: Mechanism and Enhanced Stability

Constructing a stable solid electrolyte interface (SEI) with high productivity and scalability is essential for the practical application of thin Li metal anodes. Here, in this work, we report a chemical vapor transformation (CVT) strategy in which Li metal is exposed to trimethylaluminum (TMA), inducing a rapid and spontaneous surface reaction that forms a robust, multilayered SEI. In situ quartz crystal microbalance (QCM) and quadrupole mass spectrometry (QMS), combined with ex situ X-ray photoelectron spectroscopy (XPS), UV Raman spectroscopy, and density functional theory (DFT) calculations, reveal that TMA removes the native passivation layer, reacts with Li metal, and drives a coupled bulk-surface transformation involving Li–Al interdiffusion. The resulting SEI exhibits a chemically graded structure consisting of an inner Li–Al alloy and an outer amorphous carbon layer formed via demethylation and ligand-exchange pathways. This modified surface exhibits significantly enhanced stability compared to that of bare Li in electrochemical cycling using liquid and solid-state electrolytes. This work unveils a unique surface-mediated bulk transformation mechanism for lithium metal and establishes CVT as a scalable and fundamentally distinct approach for the interfacial engineering of reactive metals.

Li metal↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

Overview of Liquid-Metal PFC R&D at the University of Illinois Urbana-Champaign

The design and implementation of future flowing liquid-lithium plasma-facing components (LLPFCs) will be dependent on several factors. Of course, one of the most important is the need to be able to deal with high heat fluxes incident on the surface of the LLPFCs, but there are also several other important liquid-metal behaviors that have been identified for their critical impact on the feasibility of a LLPFC. One of these is the ability to constantly wet 100% of the plasma-facing component area and the best way to achieve that. Another key point is knowing and understanding the erosion and corrosion of the surfaces subject to a flowing liquid-lithium system and the ability for hydrogen and helium uptake by the system. The Center for Plasma Material Interactions (CPMI) has been tasked with looking at these various issues. The Mock-up Entry module for EAST device was used to investigate wetting and erosion effects and to design a suitable distribution and collection system with a liquid-lithium loop. The vapor shielding effects of lithium on the surface were also modeled and studied. A model coupling CRANE, an open-source global reaction network solver, and Zapdos, a plasma transport solver, is being developed to better understand the dynamics of the vapor cloud. Experiments on the Magnum-PSI at the Dutch Institute for Fundamental Energy Research have been carried out to study the vapor shielding effect and obtain experimental benchmarks to verify the model. Also, initial experiments using the Hybrid Illinois Device for Research and Applications have been performed to understand the pumping effects of lithium on helium. Experiments with a drop of liquid lithium (~100 mg) into a helium plasma have shown the ability of lithium to take out the cold recycling helium gas as well as hydrogen and oxygen impurity gases. The improvement in plasma performance was significant, and further understanding of this effect will have impacts on how future LLPFCs will be designed. Further investigation into the exact mechanism for helium pumping by lithium needs to be performed in the future. Finally, this paper presents a summary of the results obtained at the CPMI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Removal of Surface Carbonate from Lithium-Ion Battery Cathode Materials via Vapor-Phase Fluorination

Herein, ultrathin metal-fluoride barrier coatings on the surface of lithium-ion battery (LIB) cathodes can improve cycling stability and prevent corrosion by acidic byproducts in the electrolyte. Atomic layer deposition (ALD) is an effective method to deposit ultrathin metal fluoride coatings on LIB cathodes. Although numerous studies have demonstrated the benefit of ALD metal fluoride coatings to LIB performance, comparatively few works have examined the effect of individual ALD precursors on the cathode surface. This paper uses X-ray photoelectron spectroscopy (XPS) measurements to elucidate the surface chemical changes on LIB cathode material surfaces upon exposure to the ALD metal fluoride precursor, hydrogen fluorine pyridine (HFPy). We found a decrease in surface carbonate and an increase in surface fluoride after HFPy exposure suggesting the conversion of lithium carbonate (Li 2 CO 3 ) to lithium fluoride (LiF). This conversion is desirable given that Li 2 CO 3 degrades LIB performance, whereas LiF provides an excellent physio-chemical barrier against chemical attack during cycling. Scanning transmission electron microscopy, X-ray energy dispersive spectroscopy, and XPS measurements following HFPy exposure to Li 2 CO 3 powder revealed the formation of a conformal LiF shell around the Li 2 CO 3 particles. Finally, we confirmed the complete conversion of similar to 7 nm ALD Li 2 CO 3 films on silicon from HFPy exposure using XPS and spectroscopic ellipsometry. The elimination of problematic Li 2 CO 3 from LIB cathode surfaces and conversion into a protective LiF coating via a single precursor vapor treatment may provide a cost-effective method for enhancing LIB performance.

25 ENERGY STORAGE↗