Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lithium detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Review of Existing and Emerging Methods for Lithium Detection and Characterization in Li-Ion and Li-Metal Batteries

Whether attempting to eliminate parasitic Li metal plating on graphite (and other Li-ion anodes) or enabling stable, uniform Li metal formation in ‘anode-free’ Li battery configurations, the detection and characterization (morphology, microstructure, chemistry) of Li that cannot be reversibly cycled is essential to understand the behavior and degradation of rechargeable batteries. In this review, various approaches used to detect and characterize the formation of Li in batteries are discussed. Each technique has its unique set of advantages and limitations, and works towards solving only part of the full puzzle of battery degradation. Going forward, multimodal characterization holds the most promise towards addressing two pressing concerns in the implementation of the next generation of batteries in the transportation sector (viz. reducing recharging times and increasing the available capacity per recharge without sacrificing cycle life). Such characterizations involve combining several techniques (experimental- and/or modeling-based) in order to exploit their respective advantages and allow a more comprehensive view of cell degradation and the role of Li metal formation in it. Additionally, it is also discussed which individual techniques, or combinations thereof, can be implemented in real-world battery management systems on-board electric vehicles for early detection of potential battery degradation that would lead to failure.

25 ENERGY STORAGE↗

Sensitivity and reliability of key electrochemical markers for detecting lithium plating during extreme fast charging

Lithium plating is one of the key challenges for enabling extreme fast charging (XFC, ≤10 to 15 min charging at ≥6C) in graphite-based lithium-ion batteries. Significant R&D effort has been focused on how to mitigate Li plating. Parallel effort is also being devoted to developing methods to detect Li plating when and if it happens during fast charging. In that regard, electrochemical (EC) signature-based detection techniques are less resource intensive, more convenient, and more practical from an end-user application perspective. However, a comprehensive understanding of key plating related EC signatures for extreme fast charging is presently unavailable. In particular, there exist distinct issues of unreliability with key plating-related EC signatures—e.g., incremental capacity (dQ.dV -1 ), differential OCV (dOCV.dt -1 ), end of lithiation (EOL) rest voltage—at XFC conditions, and the underlying reasons have not been explored and identified methodically. Using a comprehensive test matrix and XFC conditions with Li/graphite half cells, this article highlights the unreliability issues associated with the EC Li plating diagnostics and explains the underlying root cause. This study finds distinct sensitivity and unreliability issues with plating related dQ.dV -1 , dOCV.dt -1 , and EOL rest voltage signatures with charging rates. Furthermore, the complex interaction between graphite and plated Li that happens through multiple competing mechanisms —Li stripping and chemical intercalation— at different charging rates is at the core of the sensitivity and unreliability issue.

25 ENERGY STORAGE↗

Detecting lithium plating dynamics in a solid-state battery with operando X-ray computed tomography using machine learning

Operando X-ray micro-computed tomography (µCT) provides an opportunity to observe the evolution of Li structures inside pouch cells. Segmentation is an essential step to quantitatively analyzing µCT datasets but is challenging to achieve on operando Li-metal battery datasets due to the low X-ray attenuation of the Li metal and the sheer size of the datasets. Herein, we report a computational approach, batteryNET, to train an Iterative Residual U-Net-based network to detect Li structures. The resulting semantic segmentation shows singular Li-related component changes, addressing diverse morphologies in the dataset. In addition, visualizations of the dead Li are provided, including calculations about the volume and effective thickness of electrodes, deposited Li, and redeposited Li. We also report discoveries about the spatial relationships between these components. The approach focuses on a method for analyzing battery performance, which brings insight that significantly benefits future Li-metal battery design and a semantic segmentation transferrable to other datasets.

25 ENERGY STORAGE↗

Thermal Dynamics and Lithium Plating Detection in High‐Power Li‐Ion Batteries for eVTOL Applications

The rapid electrification of aerial transportation is driving the need for high‐performance Li‐ion batteries that can operate reliably under stringent thermal and safety constraints. The unique mission profile of electric Vertical Take‐off and Landing (eVTOL) aircraft necessitates a focused investigation into the thermal behavior and safety characteristics of these batteries. Here, in this study, operando isothermal microcalorimetry is employed to examine the thermal evolution of Li‐ion batteries under cycling conditions representative of eVTOL operations. These findings reveal that high‐power discharge events—such as those during take‐off and landing—shift the thermal response toward exothermic behavior, in contrast to the typically endothermic response expected under near‐equilibrium cycling conditions. Additionally, the results suggest that advanced electrolyte formulations may help suppress excess heat generation, thereby improving battery safety. Notably, the calorimetric results exhibit a distinct thermal signature associated with lithium plating, offering a potential diagnostic for detecting Li plating during eVTOL operation. Overall, this study demonstrates the utility of isothermal microcalorimetry as a valuable tool for assessing thermal risks in Li‐ion batteries for eVTOL applications, and highlights the importance of targeted design strategies to mitigate safety hazards during high‐power demand scenarios.

Li plating↗

Detection of lithium in the cool halo dwarfs Groombridge 1830 and HD 134439: Implications for internal stellar mixing and cosmology

Lithium abundances in halo stars, when interpreted correctly, hold the key to uncovering the primordial Li abundance Li(sub p). However, whereas standard stellar evolutionary models imply consistency in standard big bang nucleosynthesis (BBN), models with rotationally induced mixing imply a higher Li(sub p), possibly implying an inconsistency in standard BBN. We report here Li detections in two cool halo dwarfs, Gmb 1830 and HD 134439. These are the coolest and lowest Li detections in halo dwarfs to date, and are consistent with the metallicity dependence of Li depletion in published models. If the recent report of a beryllium deficiency in Gmb 1830 represents a real Be depletion, then the rotational models would be favored. We propose tests to reduce critical uncertainties.

Deliyannis, Constantine P.↗

Non-Invasive Electrode Impedance Estimation for Optimized Charge Profile Parameterization of Lithium-Ion Batteries

This work presents a non-invasive method for parameterizing a physically motivated equivalent circuit model of lithium-ion batteries using operando electrochemical impedance spectroscopy and time-domain data. The proposed model consists exclusively of linear circuit elements, enabling computationally efficient simulation and real-time implementation on battery management system chips. By integrating frequency- and time-domain measurements, the model accurately estimates internal states such as the negative electrode potential, achieving a root mean square error of 12.3 mV during fast charging validation. Parameterization requires only rate tests with sinusoidal perturbations at three different ambient temperatures, making the approach experimentally accessible. The model reveals key insights into battery behavior, including rate-dependent overpotentials primarily governed by charge transfer kinetics at the positive electrode, and temperature-dependent impedance contributions from both charge transfer and solid-state diffusion processes. Validation using reference electrodes confirms the model’s ability to detect lithium plating onset and reproduce impedance behavior across a wide range of operating conditions. The approach enables in situ optimization of fast charging profiles and lays the foundation for future extensions incorporating aging effects and plating dynamics.

25 ENERGY STORAGE↗

Detecting onset of lithium plating during fast charging of Li-ion batteries using operando electrochemical impedance spectroscopy

Electrochemical plating of Li metal on the graphite electrode is the key limitation behind slow charging times of Li-ion batteries (LIBs) in electric vehicles (EVs). Currently, electrochemical methods to detect the onset of Li plating while a battery is fast charging are sparse. In this study, we use operando electrochemical impedance spectroscopy to reliably detect the onset of Li plating on graphite electrodes in three-electrode LIBs. An increase in the graphite solid-electrolyte interface (SEI) resistance indicates that Li plating has occurred. By cross-validating with a highly sensitive ex situ chemical titration, we determine that this technique can detect very small amounts of plated Li (<0.6% of the graphite electrode's capacity). We also offer physical explanations for the observed impedance behavior. Finally, we show that this technique can be applied to standard two-electrode LIB systems, making the method an important step toward safely implementing fast charging protocols for LIBs in EVs.

25 ENERGY STORAGE↗

Onboard early detection and mitigation of lithium plating in fast-charging batteries

Fast-charging is considered as one of the most desired features needed for lithium-ion batteries to accelerate the mainstream adoption of electric vehicles. However, current battery charging protocols mainly consist of conservative rate steps to avoid potential hazardous lithium plating and its associated parasitic reactions. A highly sensitive onboard detection method could enable battery fast-charging without reaching the lithium plating regime. Here, we demonstrate a novel differential pressure sensing method to precisely detect the lithium plating event. By measuring the real-time change of cell pressure per unit of charge (dP/dQ) and comparing it with the threshold defined by the maximum of dP/dQ during lithium-ion intercalation into the negative electrode, the onset of lithium plating before its extensive growth can be detected with high precision. In addition, we show that by integrating this differential pressure sensing into the battery management system (BMS), a dynamic self-regulated charging protocol can be realized to effectively extinguish the lithium plating triggered by low temperature (0 °C) while the conventional static charging protocol leads to catastrophic lithium plating at the same condition. We propose that differential pressure sensing could serve as an early nondestructive diagnosis method to guide the development of fast-charging battery technologies.

25 ENERGY STORAGE↗

Nuclear recoil detection with color centers in bulk lithium fluoride

We present initial results on the detection of nuclear recoils in lithium fluoride (LiF) through the fluorescence of color centers created by particle interactions in the crystal lattice. Using light-sheet fluorescence microscopy, we image nuclear recoil tracks from both fast and thermal neutron interactions deep within a cubic-centimeter-scale sample. Automated three-dimensional feature extraction based on machine-learning tools enables the identification and classification of individual events. We observe that the fluorescence response of LiF to gamma irradiation is strongly suppressed, by a factor of 30–50 compared to neutron exposure, demonstrating intrinsic insensitivity to electromagnetic backgrounds. The observed and simulated event characteristics are consistent, including their number, size, and topology. These results establish the feasibility of LiF as a scalable detection medium for rare nuclear-recoil events and constitute a first step toward 10–1000 g scale detectors with single-event sensitivity for applications in reactor-neutrino detection, neutron spectroscopy, and dark matter searches.

Aroujo, G R [University of Zurich]↗

3D Detection of Lithiation and Lithium Plating in Graphite Anodes during Fast Charging

A barrier to the widespread adoption of electric vehicles is enabling fast charging lithium-ion batteries. At normal charging rates, lithium ions intercalate into the graphite electrode. At high charging rates, lithiation is inhomogeneous, and metallic lithium can plate on the graphite particles, reducing capacity and causing safety concerns. We have built a cell for conducting high-resolution in situ X-ray microtomography experiments to quantify three-dimensional lithiation inhomogeneity and lithium plating. Our studies reveal an unexpected correlation between these two phenomena. During fast charging, a layer of mossy lithium metal plates at the graphite electrode–separator interface. The transport bottlenecks resulting from this layer lead to underlithiated graphite particles well-removed from the separator, near the current collector. These underlithiated particles lie directly underneath the mossy lithium, suggesting that lithium plating inhibits further lithiation of the underlying electrode.

25 ENERGY STORAGE↗

Avoiding thermal runaway in lithium-ion batteries using ultrasound detection of early failure mechanisms

Thermal runaway leading to catastrophic failure has slowed the adoption of lithium-ion batteries, highlighting the need for early warning systems. In this work, ultrasound is used to detect physical changes in 0.950 Ah Li-ion battery cells by inducing conditions associated with thermal runaway. Ultrasound signal features are extracted as the batteries are cycled under baseline conditions and subsequently subjected to constant current and voltage overcharges. Two conditions identifying failure are defined: a warning to detect the start of overcharge and an emergency stop (E-stop), to immediately take the battery out of service. Using changes in ultrasound signal features, consistent warning and stopping classifications are applied to all failure experiments. On average, a warning notification was issued after 15% of the overcharge time and an E-stop was triggered after 35% of total overcharge duration before failure. Further testing suggests that it is possible to avoid thermal runaway by reacting to intermediate, warning notifications prior to an immediate E-stop. In other words, not only can detection derived by ultrasound identify battery failure before a catastrophic event, but can also provide early, actionable warnings so that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.

25 ENERGY STORAGE↗

The 2RE J0241-525: A Nearby Post T-Tauri Visual Binary System

We present high spatial resolution X-ray observations, photometry and spectroscopy of the two low mass, active stars proposed as optical counterparts to the extreme ultraviolet source 2RE J0241-525 (equal to EUVE J0241-530). It is confirmed that both stars, which are of types dK7e and dM3e and separated by 22 arcsecs, are sources of soft X-ray emission and exhibit substantial chromospheric activity. Radial velocity measurements indicate that the two components are physically associated and most probably single. The projected equatorial velocities are measured as (75 +/- 3) km/s and (11.7 +/- 0.7) km/s for the hotter and cooler components, respectively, and whilst the hotter component has a relatively high photospheric lithium abundance, log N(Li) equal to 1.5 +/- 0.2, we are unable to detect any lithium in the cooler star. Isochrone fitting to this 'mini-cluster' yields an age of (3-70) Myr and a distance of (19-60) pc. An empirical comparison of the lithium abundances with those for similar stars in young clusters and associations narrows this age range to (5-30) Myr and a corresponding distance of (26-50) pc. We conclude that this object is a nearby post T-Tauri system, but we cannot locate any possible birth site. It appears unlikely that the system can have been ejected from a nearby open cluster in a two or three body encounter.

Jeffries, R. D.↗