Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid xenon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A gamma-ray imaging telescope based on liquid xenon

A liquid-xenon time projection chamber (TPC) is discussed in terms of its utility as an imaging telescope for high energy astrophysics. The concept exploits the efficiency of xenon as an ionization and scintillation medium for imaging astrophysical gamma-ray sources. The design fundamentally follows the approach of an ionization calorimeter functioning as a TPC dedicated to 3D tracking. A schematic diagram of the instrument is presented, and the device measures the ionization signals - resulting from gamma-ray interactions with xenon - on collection electrodes. The liquid xenon instrument permits the identification of the direction of the Compton electron and thereby determines the location of the source. The energy region of 1-30 MeV is covered by the instrument, and source localization is possible for the entire range.

Aprile, Elena↗

Development of liquid xenon detectors for gamma ray astronomy

The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

Aprile, Elena↗

Liquid xenon time projection chamber for gamma rays in the MeV region: Development status

The feasibility of a large volume Liquid Xenon Time Projection Chamber (LXe-TPC) for three dimensional imaging and spectroscopy of cosmic gamma ray sources, was tested with a 3.5 liter prototype. The observation of induction signals produced by MeV gamma rays in liquid xenon is reported, with a good signal-to-noise ratio. The results represent the first experimental demonstration with a liquid xenon ionization chamber of a nondestructive readout of the electron image produced by point-like charges, using a sense wire configuration of the type originally proposed in 1970 by Gatti et al. An energy resolution as good as that previously measured by the millimeter size chambers, was achieved with the large prototype of 4.4 cm drift gap.

Aprile, E.↗

Electron avalanche in liquid xenon

Measurements in liquid Xe are reported of the characteristic function that describes the avalanche, the first Townsend coefficient. An electron avalanche occurs when the drifting electrons attain sufficient kinetic energy from the electric field to cause additional ionization. Data on the avalanche were obtained by studying the pulses in a liquid-filled proportional chamber as a function of applied voltage and anode diameter. The results of the investigation show that the avalanche of free electrons in purified liquid Xe is adequately described by the same formalism used for the avalanche of electrons in gases.

Derenzo, S. E.↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

The polarization sensitivity of the liquid xenon imaging telescope

The properties and the expected performance of a liquid xenon (LXe) gamma ray imaging telescope, optimized for the MeV energy region, are presented. The unique potential of this telescope as a Compton polarimeter is particularly emphasized. Based on Monte Carlo simulations we show that the modulation factor is as high as 40 percent at 1 MeV with a detection efficiency close to 20 percent. These figures of merit combined with the excellent background suppression capability of the three dimensional position sensitive LXe detector yield sensitivity at the three sigma level to polarization fractions as small as a few percent for strong sources, even in a balloon flight.

Aprile, Elena↗

The polarization sensitivity of the liquid xenon imaging telescope

The properties and the expected performance of a liquid xenon (LXe) gamma-ray imaging telescope, optimized for the MeV energy region, are presented. The unique potential of this telescope as a Compton polarimeter is particularly emphasized. Based on Monte Carlo simulations, we show that the modulation factor is as high as 40% at 1 MeV with a detection efficiency close to 20%. These figures of merit, combined with the excellent background suppression capability of the three-dimensional position sensitive LXe detector, yield sensitivity at the 3 sigma level to polarization fractions as small as a few percent for strong sources, even in a balloon flight.

Aprile, E.↗

Development of a high resolution liquid xenon imaging chamber for gamma-ray astronomy

The objective was to develop the technology of liquid xenon (LXe) detectors for spectroscopy and imaging of gamma rays from astrophysical sources emitting in the low to medium energy regime. In particular, the technical challenges and the physical processes relevant to the realization of the LXe detector operated as a Time Projection Chamber (TPC) were addressed and studied. Experimental results were obtained on the following topics: (1) long distance drift of free electrons in LXe (purity); (2) scintillation light yield for electrons and alphas in LXe (triggering); and (3) ionization yield for electrons and gamma rays in LXe (energy resolution). The major results from the investigations are summarized.

Aprile, Elena↗

A liquid xenon radioisotope camera.

A new type of gamma-ray camera is discussed that makes use of electron avalanches in liquid xenon and is currently under development. It is shown that such a radioisotope camera promises many advantages over any other existing gamma-ray cameras. Spatial resolution better than 1 mm and counting rates higher than one million C/sec are possible. An energy resolution of 11% FWHM has recently been achieved with a collimated Hg-203 source using a parallel-plate ionization chamber containing a Frisch grid.

Zaklad, H.↗

A Monte Carlo analysis of the liquid xenon TPC as gamma ray telescope

Extensive Monte Carlo modeling of a coded aperture x ray telescope based on a high resolution liquid xenon TPC has been performed. Results on efficiency, background reduction capability and source flux sensitivity are presented. We discuss in particular the development of a reconstruction algorithm for events with multiple interaction points. From the energy and spatial information, the kinematics of Compton scattering is used to identify and reduce background events, as well as to improve the detector response in the few MeV region. Assuming a spatial resolution of 1 mm RMS and an energy resolution of 4.5 percent FWHM at 1 MeV, the algorithm is capable of reducing by an order of magnitude the background rate expected at balloon altitude, thus significantly improving the telescope sensitivity.

Aprile, E.↗

A High Resolution Liquid Xenon Imaging Telescope for 0.3-10 MeV Gamma Ray Astrophysics: Construction and Initial Balloon Flights

The results achieved with a 3.5 liter liquid xenon time projection chamber (LXe-TPC) prototype during the first year include: the efficiency of detecting the primary scintillation light for event triggering has been measured to be higher than 85%; the charge response has been measured to be stable to within 0.1% for a period of time of about 30 hours; the electron lifetime has been measured to be in excess of 1.3 ms; the energy resolution has been measured to be consistent with previous results obtained with small volume chambers; X-Y gamma ray imaging has been demonstrated with a nondestructive orthogonal wires readout; Monte Carlo simulation results on detection efficiency, expected background count rate at balloon altitude, background reduction algorithms, telescope response to point-like and diffuse sources, and polarization sensitivity calculations; and work on a 10 liter LXe-TPC prototype and gas purification/recovery system.

Aprile, Elena↗

Development of a High Resolution Liquid Xenon Imaging Telescope for Medium Energy Gamma Ray Astrophysics

In the third year of the research project, we have (1) tested a 3.5 liter prototype of the Liquid Xenon Time Projection Chamber, (2) used a prototype having a 4.4 cm drift gap to study the charge and energy resolution response of the 3.5 liter chamber, (3) obtained an energy resolution as good as that previously measured by us using chambers with drift gaps of the order of millimeters, (4) observed the induction signals produced by MeV gamma rays, (4) used the 20 hybrid charge sensitive preamplifiers for a nondestructive readout of the electron image on the induction wires, (5) performed extensive Monte Carlo simulations to obtain results on efficiency, background rejection capability, and source flux sensitivity, and (6) developed a reconstruction algorithm for events with multiple interaction points.

Aprile, Elena↗

The liquid-xenon Compton telescope - A new technique for gamma-ray astronomy

We propose a new technique for gamma-ray astronomy in the difficult but important energy decade from 0.3 to 3.0 MeV. Cosmic gamma rays Compton scatter in a liquid-xenon wire proportional chamber recently developed at Lawrence Berkeley Laboratory (Derenzo, et al., 1972; Muller, et al., 1971) and then are totally absorbed in a second chamber. The energy and position of each interaction is recorded for each gamma ray. This information determines a circle on the celestial sphere which must intersect the source position. A localized source of gamma-rays would show itself as the intersection of many such circles. We expect to locate sources to a fraction of a square degree in a balloon-borne sky survey experiment using an instrument with a one steradian acceptance.

Dauber, P. M.↗

A liquid xenon imaging telescope for gamma ray astrophysics: Design and expected performance

A high resolution telescope for imaging cosmic x ray sources in the MeV region, with an angular resolution better than 0.5 deg is being developed as balloon-borne payload. The instrument consists of a 3-D liquid xenon TPC as x ray detector, coupled with a coded aperture at a distance of 1 meter. A study of the actual source distribution of the 1.809 MeV line from the decay of Al-26 and the 511 keV positron-electron annihilation line is among the scientific objectives, along with a search for new x ray sources. The telescope design parameters and expected minimum flux sensitivity to line and continuum radiation are presented. The unique capablity of the LXe-TPC as a Compton Polarimeter is also discussed.

Aprile, E.↗

A high resolution liquid xenon imaging telescope for 0.3-10 MeV gamma-ray astrophysics: Construction and initial balloon flights

An instrument is described which will provide a direct image of gamma-ray line or continuum sources in the energy range 300 keV to 10 MeV. The use of this instrument to study the celestial distribution of the (exp 26)Al isotope by observing the 1.809 MeV deexcitation gamma-ray line is illustrated. The source location accuracy is 2' or better. The imaging telescope is a liquid xenon time projection chamber coupled with a coded aperture mask (LXe-CAT). This instrument will confirm and extend the COMPTEL observations from the Compton Gamma-Ray Observatory (CGRO) with an improved capability for identifying the actual Galactic source or sources of (exp 26)Al, which are currently not known with certainty. sources currently under consideration include red giants on the asymptotic giant branch (AGB), novae, Type 1b or Type 2 supernovae, Wolf-Rayet stars and cosmic-rays interacting in molecular clouds. The instrument could also identify a local source of the celestial 1.809 MeV gamma-ray line, such as a recent nearby supernova.

Aprile, Elena↗

A study of the scintillation light induced in liquid xenon by electrons and alpha particles

The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.

Aprile, Elena↗