Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid xenon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

UA'(1): The search for low-mass dark matter in liquid xenon / Infrared Light for Liquid Xenon TPCs

Liquid xenon-based time projection chambers are used in a variety of applications spanning from the search for dark matter or signals from coherent neutrino-nucleus scattering, to detectors used in medicine and for nuclear non-proliferation. Extending the useful energy range of these detectors down to lower energies will prove extremely useful for such applications. However, various sources of single- and few-electron backgrounds limit the utility of experiments such as LZ and XENONnT to searches of lighter dark matter articles in the MeV mass range. These same backgrounds also limit their utility to measure signals from coherent neutrino-nucleus scattering of solar boron-8 neutrinos and Galactic supernovae. This research worked on multiple mitigation strategies to reduce these backgrounds, through improved xenon purity, infrared irradiation, and an improved theoretical understanding. Multiple dedicated liquid xenon setups were built to execute those tests, and data was successfully taken. Liquid xenon purity was shown to have an important impact, but infrared irradiation did not reduce these backgrounds.

47 OTHER INSTRUMENTATION↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A gamma-ray imaging telescope based on liquid xenon

A liquid-xenon time projection chamber (TPC) is discussed in terms of its utility as an imaging telescope for high energy astrophysics. The concept exploits the efficiency of xenon as an ionization and scintillation medium for imaging astrophysical gamma-ray sources. The design fundamentally follows the approach of an ionization calorimeter functioning as a TPC dedicated to 3D tracking. A schematic diagram of the instrument is presented, and the device measures the ionization signals - resulting from gamma-ray interactions with xenon - on collection electrodes. The liquid xenon instrument permits the identification of the direction of the Compton electron and thereby determines the location of the source. The energy region of 1-30 MeV is covered by the instrument, and source localization is possible for the entire range.

Aprile, Elena↗

Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX

Abstract Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗

Electron-ion recombination in composite interactions in liquid xenon

The response of liquid xenon to various types of ionizing radiation has been extensively studied theoretically and experimentally. Recent progress in direct detection dark matter experiments highlights the significance of composite events, where multiple particles interact with xenon simultaneously and generate overlapping ionization signatures. In these events, recombination of electrons and ions associated with different primary particles leads to additional suppression of the ionization signal, introducing a new source of uncertainty in dark matter searches and Migdal effect studies. We developed a model to estimate the recombination enhancement for overlapping low-energy particle interactions. This method, which has minimal dependence on xenon microphysics and is primarily driven by existing experimental data, yields predictions that are consistent with available measurements of composite interactions. Furthermore, we demonstrate that the model predictions are robust against xenon microphysics assumptions.

charge↗

HydroX, a light dark matter search with hydrogen-doped liquid xenon time projection chambers

Experimental efforts searching for dark matter particles over the last few decades have ruled out many candidates led by the new generation of tonne-scale liquid xenon. For light dark matter, hydrogen could be a better target than xenon as it would offer a better kinematic match to the low mass particles. This article describes the HydroX concept, an idea to expand the dark matter sensitivity reach of large liquid xenon detectors by adding hydrogen to the liquid xenon. We discuss the nature of signal generation in liquid xenon to argue that the signal produced at the interaction site by a dark matter–hydrogen interaction could be significantly enhanced over the same interaction on xenon, increasing the sensitivity to the lightest particles. We discuss the technical implications of adding hydrogen to a xenon detector, as well as some background considerations. Finally, we make projections as to the potential sensitivity of a HydroX implementation and discuss next steps.

Experimental particle physics↗

HydroX, a light dark matter search with hydrogen-doped liquid xenon time projection chambers

Experimental efforts searching for dark matter particles over the last few decades have ruled out many candidates led by the new generation of tonne-scale liquid xenon. For light dark matter, hydrogen could be a better target than xenon as it would offer a better kinematic match to the low mass particles. This article describes the HydroX concept, an idea to expand the dark matter sensitivity reach of large liquid xenon detectors by adding hydrogen to the liquid xenon. We discuss the nature of signal generation in liquid xenon to argue that the signal produced at the interaction site by a dark matter–hydrogen interaction could be significantly enhanced over the same interaction on xenon, increasing the sensitivity to the lightest particles. We discuss the technical implications of adding hydrogen to a xenon detector, as well as some background considerations. Finally, we make projections as to the potential sensitivity of a HydroX implementation and discuss next steps.

Lippincott, W. H. [UC, Santa Barbara] (ORCID:00000↗

Development of liquid xenon detectors for gamma ray astronomy

The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

Aprile, Elena↗

Measurement of the onset of nucleate boiling in liquid xenon

We report the first precision measurement of the superheat temperature required for bubble nucleation in liquid xenon of Δ T wall,ONB = (16.9±0.5) K and Δ T wall,ONB = (19.2 +0.4 -1.1 ) K at pressures of P = (0.98±0.02) bar and P = (1.32 +0.05 -0.01 ) bar, respectively. Both are measured at a subcooled bulk fluid temperature of ~ 162 K. A dedicated liquid xenon setup is used to measure the temperature at which bubble nucleation first appears on the flat surface of a resistor. The associated average heat flux at the surface of the resistor is determined using fluid dynamics simulations. Future experiments can use these experimental results to determine the likelihood of boiling in liquid xenon and to design effective thermal sinks that prevent bubble nucleation.

47 OTHER INSTRUMENTATION↗

Liquid xenon time projection chamber for gamma rays in the MeV region: Development status

The feasibility of a large volume Liquid Xenon Time Projection Chamber (LXe-TPC) for three dimensional imaging and spectroscopy of cosmic gamma ray sources, was tested with a 3.5 liter prototype. The observation of induction signals produced by MeV gamma rays in liquid xenon is reported, with a good signal-to-noise ratio. The results represent the first experimental demonstration with a liquid xenon ionization chamber of a nondestructive readout of the electron image produced by point-like charges, using a sense wire configuration of the type originally proposed in 1970 by Gatti et al. An energy resolution as good as that previously measured by the millimeter size chambers, was achieved with the large prototype of 4.4 cm drift gap.

Aprile, E.↗

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

First Measurement of Discrimination between Helium and Electron Recoils in Liquid Xenon for Low-Mass Dark Matter Searches

We report the first measurement of discrimination between low-energy helium recoils and electron recoils in liquid xenon. This result is relevant to proposed low-mass dark matter searches which seek to dissolve light target nuclei in the active volume of liquid-xenon time projection chambers. Low-energy helium recoils were produced by degrading α particles from Po 210 with a gold foil situated on the cathode of a liquid xenon time-projection chamber. The resulting population of helium recoil events is well separated from electron recoils and is also offset from the expected position of xenon nuclear recoil events. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron avalanche in liquid xenon

Measurements in liquid Xe are reported of the characteristic function that describes the avalanche, the first Townsend coefficient. An electron avalanche occurs when the drifting electrons attain sufficient kinetic energy from the electric field to cause additional ionization. Data on the avalanche were obtained by studying the pulses in a liquid-filled proportional chamber as a function of applied voltage and anode diameter. The results of the investigation show that the avalanche of free electrons in purified liquid Xe is adequately described by the same formalism used for the avalanche of electrons in gases.

Derenzo, S. E.↗

The XLZD Design Book: towards the next-generation liquid xenon observatory for dark matter and neutrino physics

This report describes the experimental strategy and technologies for XLZD, the next-generation xenon observatory sensitive to dark matter and neutrino physics. In the baseline design, the detector will have an active liquid xenon target of 60 tonnes, which could be increased to 80 tonnes if the market conditions for xenon are favorable. It is based on the mature liquid xenon time projection chamber technology used in current-generation experiments, LZ and XENONnT. The report discusses the baseline design and opportunities for further optimization of the individual detector components. The experiment envisaged here has the capability to explore parameter space for Weakly Interacting Massive Particle (WIMP) dark matter down to the neutrino fog, with a 3σ evidence potential for WIMP-nucleon cross sections as low as 3 x 10 –49 cm 2 (at 40 GeV/c 2 WIMP mass). The observatory will also have leading sensitivity to a wide range of alternative dark matter models. It is projected to have a 3σ observation potential of neutrinoless double beta decay of 136 Xe at a half-life of up to 5.7 x 10 27 years. Additionally, it is sensitive to astrophysical neutrinos from the sun and galactic supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗