Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Use of high pressure liquid chromatography in the study of liquid lubricant oxidation

The general principles of classical liquid chromatography and high-pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analysis of a C-ether liquid lubricant by each technique is illustrated. An analysis by size exclusion chromatography of an ester lubricant, which had been degraded using a micro-oxidation apparatus, is illustrated to show how HPLC can be used in the study of high-temperature lubricant degradation.

Morales, W.↗

Rapid estimation of concentration of aromatic classes in middistillate fuels by high-performance liquid chromatography

An high performance liquid chromatography (HPLC) method to estimate four aromatic classes in middistillate fuels is presented. Average refractive indices are used in a correlation to obtain the concentrations of each of the aromatic classes from HPLC data. The aromatic class concentrations can be obtained in about 15 min when the concentration of the aromatic group is known. Seven fuels with a wide range of compositions were used to test the method. Relative errors in the concentration of the two major aromatic classes were not over 10 percent. Absolute errors of the minor classes were all less than 0.3 percent. The data show that errors in group-type analyses using sulfuric acid derived standards are greater for fuels containing high concentrations of polycyclic aromatics. Corrections are based on the change in refractive index of the aromatic fraction which can occur when sulfuric acid and the fuel react. These corrections improved both the precision and the accuracy of the group-type results.

Otterson, D. A.↗

High-pressure liquid chromatography: A brief introduction and its application in analyzing the degradation of a C-ether (Thio-ether) liquid lubricant

The general principles of classical liquid chromatography and high pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analytical separation of a C-ether liquid lubricant by each technique is illustrated. A practical application of HPLC is then demonstrated by analyzing a degraded C-ether liquid lubricant from full scale, high temperature bearing tests.

Source record↗

Liquid Chromatography Mass Spectrometry Instrumentation and Methodology

This report reviews instrumentation and techniques utilized in liquid chromatography mass spectrometry (LC-MS). The analytical advantages and disadvantages of each major component of different LC-MS systems are discussed, along with a comparison between LC-MS, liquid chromatography tandem mass spectrometry (LC-MS/MS), and gas chromatography mass spectrometry (GC-MS). This report also details future work regarding the use of LC-MS/MS to analyze and identify degradation products from an extensive accelerated aging process of nitroplasticizer (NP). This report is the first of a series on the use of LC-MS to understand the degradation mechanisms of NP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas-liquid chromatography in lunar organic analysis.

Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

Gehrke, C. W.↗

A Unified Analytical Method Greenness Score ( uAMGS ) Quantifies How Microscopic Imaging Is Greener Than Conventional Liquid Chromatography

Green chemistry is a set of principles for assessing, developing, and implementing methods that are safer, more efficient, and less detrimental to the environment. The analytical method greenness score (AMGS) is one of many metrics that attempt to evaluate traditional liquid chromatography (LC) based on the energy consumption of the instrument and the safety, health risks, and environmental impact of the solvents employed. Unfortunately, in practice, the AMGS is primarily focused on traditional separation methods in the pharmaceutical industry and is not amenable to cutting-edge separation science, including miniaturization. To broaden this scope, the unified Analytical Method Greenness Score (uAMGS) is presented here, which clarifies and expands on the underlying mathematics and incorporates both dimensional and uncertainty analysis, enabling its application to a broader range of analytical techniques. The uAMGS is used to compare the greenness of two distinct methods: single-molecule microscopy (SMM) and high-performance liquid chromatography (HPLC), which were used to collect equivalent data. uAMGS determines that SMM is significantly greener than HPLC due primarily to decreased solvent consumption. Overall, the uAMGS should allow chemists ranging from undergraduates to industrial PhDs to assess the greenness of a wide range of separations.

chemical separations↗

High-performance liquid chromatography of oligoguanylates at high pH

Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

Non-NASA Center↗

Picoflow Liquid Chromatography–Mass Spectrometry for Ultrasensitive Bottom-Up Proteomics Using 2-μm-i.d. Open Tubular Columns

In many areas of applications key objectives of chemical separations and analysis are to minimize the sample quantity while maximizing the chemical information obtained. Increasing measurement sensitivity is especially critical for proteomics research, especially when processing trace samples and where multiple measurements are desired. A rich collection of technologies has been developed, but the resulting sensitivity remains insufficient for achieving in-depth coverage of proteomic samples as small as single cells. In this paper, we combine picoliter-scale liquid chromatography (picoLC) with mass spectrometry (MS) to address this issue. The picoLC employs 2-µm-i.d. open tubular column to reduce the sample input needed to greatly increase the sensitivity achieved using electrospray ionization (ESI) with MS. With this picoLC-MS system, we show that we can identify ~1000 proteins reliably using only 30 pg of tryptic peptides, representing a 10–100-fold sensitivity improvement compared with the state-of-the-art liquid chromatography (LC) or capillary electrophoresis (CE)-MS methods. PicoLC-MS extends the limit of separation science and is expected to be a powerful tool for single cell proteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid chromatography at critical conditions (LCCC): Capabilities and limitations for polymer analysis

This paper investigates liquid chromatography at critical condition (LCCC) for polymer analysis. Based on controversial claims on the separation of cyclic polymers from linear analogues in the literature, the efficiency of LCCC for separation and purity analysis is questioned. Polyisobutylene (PIB) and poly(3,6-dioxa-1,8-octanedithiols) (polyDODT) were used for the study. Here, the structure of low molecular weight cyclic and linear polyDODT was demonstrated by MALDI-ToF. NMR did not show the presence of thiol end groups in higher molecular weight PIB-disulfide and polyDODT samples, so they were considered cyclic polymers. When a low molecular weight polyDODT oligomer with only traces of cycles, as demonstrated by MALDI-ToF, was mixed with an M n = 27K g/mol cyclic sample, LCCC did not detect the presence of linear oligomers at 6 wt%. Based on the data presented here, it can be concluded that the LCCC method is not capable of measuring < 6 wt% linear contamination so earlier claims for cyclic polystyrene (PS) samples purified by LCCC having < 3 % linear contaminants are questioned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Seven Organic Impurities in FD&C Yellow No. 6 by Ultra-High-Performance Liquid Chromatography

The U.S. Food and Drug Administration (FDA) batch certifies FD&C Yellow No. 6 (Y6) to ensure that the color additive meets requirements published in the Code of Federal Regulations (CFR), including specifications for seven organic manufacturing impurities consisting of two intermediates, a reaction by-product, an impurity originating from an intermediate, and three subsidiary colors. An ultra-high-performance liquid chromatography (UHPLC) method was developed and validated for determining seven organic impurities in Y6. For comparison, the currently used high-performance liquid chromatography (HPLC) method was also validated. The new UHPLC method uses a 1.7 µm particle size biphenyl column with aqueous ammonium formate and methanol as eluants. Analytes are identified by comparing their retention times and UV-visible spectra to those of reference standards. Calibration is performed in the presence of the dye matrix and analyte levels are determined from their peak areas. UHPLC and HPLC validation studies obtained linear calibration curves and excellent values for limits of detection, limits of quantitation, recovery, repeatability, and intermediate precision for all analytes. Survey analyses of 30 samples using the UHPLC and HPLC methods yielded results that were consistent within experimental error; however, the UHPLC method provided more accurate results for two analytes that coelute using the HPLC method. The UHPLC method satisfies the accuracy and precision requisites for routine certification of Y6. The UHPLC method is faster and generates less waste than the HPLC method while delivering better sensitivity, separation, and accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗