Engineering PapersSearch

SEARCH · Engineering Papers

Results for “linear induction accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Free electron lasers driven by linear induction accelerators: High power radiation sources

The technology of Free Electron Lasers (FELs) and linear induction accelerators (LIAs) is addressed by outlining the following topics: fundamentals of FELs; basic concepts of linear induction accelerators; the Electron Laser Facility (a microwave FEL); PALADIN (an infrared FEL); magnetic switching; IMP; and future directions (relativistic klystrons). This presentation is represented by viewgraphs only.

Orzechowski, T. J.

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator

Applications of the Strategic Defense Initiative's compact accelerators

The Strategic Defense Initiative's (SDI) investment in particle accelerator technology for its directed energy weapons program has produced breakthroughs in the size and power of new accelerators. These accelerators, in turn, have produced spinoffs in several areas: the radio frequency quadrupole linear accelerator (RFQ linac) was recently incorporated into the design of a cancer therapy unit at the Loma Linda University Medical Center, an SDI-sponsored compact induction linear accelerator may replace Cobalt-60 radiation and hazardous ethylene-oxide as a method for sterilizing medical products, and other SDIO-funded accelerators may be used to produce the radioactive isotopes oxygen-15, nitrogen-13, carbon-11, and fluorine-18 for positron emission tomography (PET). Other applications of these accelerators include bomb detection, non-destructive inspection, decomposing toxic substances in contaminated ground water, and eliminating nuclear waste.

Montanarelli, Nick

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS

Knolle Magnetrans: A magnetically levitated train system

The Knolle Magnetrans is a continuous transportation system featuring small cars traveling in rapid succession, levitated by permanent magnets in repulsion, and propelled by stationary linear induction motors. The vehicles' headway, speed, acceleration, and deceleration are designed into the system and mechanically enforced. Passengers board dynamically and controls consist of a simple on-off relay. This paper summarizes the system design goals, describes the system components and discusses related environmental issues.

Knolle, Ernst G.

Effect of the amount of Na2SO4 on the high temperature corrosion of Udimet-700

The corrosion of Udimet-700, coated with different doses of Na2SO4, was studied in an isothermal thermogravimetric test in the temperature range 900 to 950 C. The weight gain curve is characterized by five distinct stages: an initial period of linear corrosion; an induction period; a period of accelerated corrosion; a period of decelerating corrosion; and a period of parabolic oxidation. The time required for the failure of the alloy increases with an increase in the amount of Na2SO4, reaches a peak and then decreases with further increase in the amount of Na2SO4. For low and intermediate doses (0.3 to 2.0 mg/sq cm), the catastrophic failure of the material occurs by the formation of Na2MoO4 and interaction of the liquid Na2MoO4 with the alloy. For heavy doses, the degradation of the material is due to the formation of large amounts of sulfides.

Misra, A. K.

Superconducting six-axis accelerometer

A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

Paik, H. J.

Recent developments in mass drivers

In the past eight months a new mass driver concept has been explored through calculation and inductance model verification. It retains the linear synchronous principle and freedom from arcs, plasmas or physical contact between the accelerated bucket and accelerator. However, it discards passive magnetic flight and obtains transverse focussing from strong off-axis restoring forces produced by drive coils operating in a pull-only mode. This paper gives the reasoning on which the new concept is based, and applies the concept to a lunar catapult design.

Oneill, G. K.

Radiation effects in Caenorhabditis elegans - Mutagenesis by high and low LET ionizing radiation

The nematode C. elegans was used to measure the effectiveness of high-energy ionized particles in the induction of three types of genetic lesions. Recessive lethal mutations in a 40-map unit autosomal region, sterility, and X-chromosome nondisjunction or damage were investigated. Induction rates were measured as a function of linear energy transfer, LET(infinity), for nine ions of atomic nunmber 1-57 accelerated at the BEVALAC accelerator. Linear kinetics were observed for all three types of lesions within the dose/fluence ranges tested and were found to vary strongly as a function of particle LET(infinity). Relative biological effectiveness (RBE) values of up to 4.2 were measured, and action cross sections were calculated and compared to mutagenic responses in other systems.

Nelson, Gregory A.

Cellular and molecular analysis of mutagenesis induced by charged particles of defined linear energy transfer

Mutation induction by charged particles of defined linear energy transfer (LET) and gamma rays was scored using human-hamster hybrid AL cells. The LET values for charged particles accelerated at the Radiological Research Accelerator Facility ranged from 10 keV/microm protons to 150 keV/microm 4He ions. The induced mutant fractions at both the S1 and HGPRT loci were dependent on the dose and LET. In addition, for each dose examined, the mutant yield at the S1 locus was 30-60 fold higher than at the corresponding HGPRT locus. To determine whether the mutation spectrum was comparably dependent on dose and LET, independent S1- and HGPRT- mutants induced by 150 keV/microm 4He ions and gamma rays were isolated, and their DNA was analyzed by both Southern blotting and multiplex PCR methods. While the majority of radiation-induced mutants showed deletions of varying sizes, the relative percentage of large deletions was found to be related to both the dose and LET of the radiation examined. Using a mutation system that can detect multilocus changes, results of the present study show that radiation-induced chromosomal loss can be in the millions of base pairs.

NASA Discipline Radiation Health

High Velocity Linear Induction Launcher with Exit-Edge Compensation for Testing of Aerospace Components

Advances in ultra high speed linear induction electromagnetic launchers over the past decade have focused on magnetic compensation of the exit and entry-edge transient flux wave to produce efficient and compact linear electric machinery. The paper discusses two approaches to edge compensation in long-stator induction catapults with typical end speeds of 150 to 1,500 m/s. In classical linear induction machines, the exit-edge effect is manifest as two auxiliary traveling waves that produce a magnetic drag on the projectile and a loss of magnetic flux over the main surface of the machine. In the new design for the Stator Compensated Induction Machine (SCIM) high velocity launcher, the exit-edge effect is nulled by a dual wavelength machine or alternately the airgap flux is peaked at a location prior to the exit edge. A four (4) stage LIM catapult is presently being constructed for 180 m/s end speed operation using double-sided longitudinal flux machines. Advanced exit and entry edge compensation is being used to maximize system efficiency, and minimize stray heating of the reaction armature. Each stage will output approximately 60 kN of force and produce over 500 G s of acceleration on the armature. The advantage of this design is there is no ablation to the projectile and no sliding contacts, allowing repeated firing of the launcher without maintenance of any sort. The paper shows results of a parametric study for 500 m/s and 1,500 m/s linear induction launchers incorporating two of the latest compensation techniques for an air-core stator primary and an iron-core primary winding. Typical thrust densities for these machines are in the range of 150 kN/sq.m. to 225 kN/sq.m. and these compete favorably with permanent magnet linear synchronous machines. The operational advantages of the high speed SCIM launcher are shown by eliminating the need for pole-angle position sensors as would be required by synchronous systems. The stator power factor is also improved.

Kuznetsov, Stephen

Comparative measurement of visual stability in Earth and cosmic space (L-4)

The frequency and the intensity of space motion sickness was reviewed and investigated. Unusual induced-gravity situations, such as rotation, linear acceleration, parallel swinging etc. were investigated as well. Visually-induced motion sensation or distorted perception were evaluated with respect to visual stability by many investigators. These studies are all concerned with the effect of gravity and the induction of motion sickness through human visual perception. Direct investigation under the microgravity situation, such as parabolic flight, Skylab, and Spacelab, was carried out. These studies focused on how human visual stability is established through various sensory afferents in specific gravity conditions. Results from these investigations indicate that sensory mismatch probably plays an important role in space motion sickness. The interaction of visual, vestibular, and somatosensory perception is smoothly coordinated under normal gravitational conditions on the Earth in our daily life. When the cooperation is destroyed or a mismatch occurs among them, motion sickness may develop not only on the Earth but also in microgravity. The latter case may be the cause of space motion sickness or space adaption syndrome. How human beings obtain visual stability even with posture changes on the ground was investigated. Visual stability can be categorized as static or dynamic. Static visual stability is concerned with orientation and dynamic stability is concerned with object motion perception. The perception of visual stability is modified by many other sensations, such as somatosensory, vestibular, and muscle tension. We will mainly focus on modifications by vestibular inputs to visual perception produced by eye movements in microgravity. The Vestibular-Oscular Reflex (VOR) is a well-known characteristic which results from the relationship between eye mobility and vestibular afferent inputs. Eye movements also modify dynamic visual perception, such as perceived object motion velocity. The VOR is constantly simulated under 1-g conditions on Earth. In fact, human beings have been habituated and 'programmed' for orientation (visual stability) in their everyday, 1-g environment. When humans are exposed to a different gravity situation, this programmed behavior must change; that is, it is reprogrammed. This is called habituation or familiarization. We hope to examine how object motion perception is perturbed and subsequently adapted in the microgravity environment. This experiment is focused on the cooperation of visual, vestibular, and somatosensory perception coordination and how it is changed or reduced in space compared to 1-g environment. We will obtain information on the coordination between eye movement and neck muscle activity by using EOG and EMG. We will also collect data from Payload Specialists using a self-diagnostic questionnaire concerned with perceptual abnormality. When each sensory input function and its integration in the higher nervous system are well-characterized, then more effective techniques to control SAS may be developed.

Koga, Kazugo